2017-11-03T00:12:52.690Z,1509667972.690 [Module Loader](CRITICAL): Could not find element LcmListener.loadAtStartup 2017-11-03T00:12:52.690Z,1509667972.690 [Module Loader](CRITICAL): Could not find element LcmPublisher.loadAtStartup 2017-11-03T00:15:32.432Z,1509668132.432 [CBIT](CRITICAL): WATER DETECTED IN PRESSURE HULL. BURNWIRE ACTIVATED 2017-11-03T00:12:52.579Z,1509667972.579 [Supervisor](IMPORTANT): Reading configuration overrides from Data/persisted.cfg 2017-11-03T00:12:55.383Z,1509667975.383 [SBIT](IMPORTANT): git: 2017-10-16-91-g1cda494 2017-11-03T00:12:55.384Z,1509667975.384 [SBIT](IMPORTANT): Kernel Release: 2.6.27.8 2017-11-03T00:12:56.554Z,1509667976.554 [CommandLine](FAULT): Scheduling is paused 2017-11-03T00:13:15.880Z,1509667995.880 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:13:39.880Z,1509668019.880 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:13:59.148Z,1509668039.148 [SBIT](IMPORTANT): Beginning Startup BIT 2017-11-03T00:13:59.184Z,1509668039.184 [CBIT](IMPORTANT): Beginning ground fault scan 2017-11-03T00:14:03.596Z,1509668043.596 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:14:10.051Z,1509668050.051 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): -0.008612 CHAN A1 (24V): 0.123316 CHAN A2 (12V): -0.005605 CHAN A3 (5V): -0.002710 CHAN B0 (3.3V): -0.001388 CHAN B1 (3.15aV): -0.000893 CHAN B2 (3.15bV): -0.001400 CHAN B3 (GND): 0.001059 OPEN: 0.005315 Full Scale Calc: 4.765 mA, -1.589 mA 2017-11-03T00:14:27.384Z,1509668067.384 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:14:51.099Z,1509668091.099 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:14:53.158Z,1509668093.158 [SBIT](IMPORTANT): SBIT PASSED 2017-11-03T00:14:53.557Z,1509668093.557 [MissionManager](IMPORTANT): Started mission Startup 2017-11-03T00:14:55.709Z,1509668095.709 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-11-03T00:15:15.099Z,1509668115.099 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:15:31.226Z,1509668131.226 [CBIT](FAULT): WATER ALARM STERN. 2017-11-03T00:15:31.679Z,1509668131.679 [CBIT](FAULT): WATER ALARM STERN. 2017-11-03T00:15:32.019Z,1509668132.019 [CBIT](FAULT): WATER ALARM STERN. 2017-11-03T00:15:32.406Z,1509668132.406 [CBIT](FAULT): WATER ALARM STERN. 2017-11-03T00:15:32.434Z,1509668132.434 [CBIT](IMPORTANT): Powered off ESP with command: ! echo 0 > /dev/loadA6 2017-11-03T00:15:32.517Z,1509668132.517 [CommandLine](IMPORTANT): got command ! echo 0 > /dev/loadA6 2017-11-03T00:15:39.099Z,1509668139.099 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:16:03.099Z,1509668163.099 [AcousticModem_Benthos_ATM900](FAULT): failed to initialize, no bytes available on serial interface 2017-11-03T00:16:03.217Z,1509668163.217 [CBIT](FAULT): Communications Fault in component: AcousticModem_Benthos_ATM900 2017-11-03T00:16:54.367Z,1509668214.367 [MissionManager](IMPORTANT): Started mission Default 2017-11-03T00:16:58.528Z,1509668218.528 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-11-03T00:16:58.963Z,1509668218.963 [CommandLine](IMPORTANT): got command restart application