2017-11-01T20:26:07.232Z,1509567967.232 [DropWeight](CRITICAL): DROP WEIGHT MISSING. 2017-11-01T20:26:07.580Z,1509567967.580 [CBIT](CRITICAL): Hardware Fault in component: DropWeight 2017-11-01T20:26:00.416Z,1509567960.416 [Supervisor](FAULT): Ignoring configuration overrides from Data/persisted.cfg 2017-11-01T20:26:05.082Z,1509567965.082 [SBIT](IMPORTANT): git: 2017-10-16-13-g367f5fc 2017-11-01T20:26:05.087Z,1509567965.087 [CBIT](FAULT): LAST RESTART WAS UNINTENTIONAL. 2017-11-01T20:26:07.577Z,1509567967.577 [CommandLine](FAULT): Scheduling is paused 2017-11-01T20:27:16.889Z,1509568036.889 [SBIT](IMPORTANT): Beginning Startup BIT 2017-11-01T20:27:16.893Z,1509568036.893 [CBIT](IMPORTANT): Beginning ground fault scan 2017-11-01T20:27:27.841Z,1509568047.841 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): -0.005195 CHAN A1 (24V): 0.126538 CHAN A2 (12V): 0.000893 CHAN A3 (5V): 0.000594 CHAN B0 (3.3V): -0.000110 CHAN B1 (3.15aV): 0.000367 CHAN B2 (3.15bV): -0.000181 CHAN B3 (GND): -0.000842 OPEN: 0.004721 Full Scale Calc: 4.765 mA, -1.589 mA 2017-11-01T20:28:05.290Z,1509568085.290 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-11-01T20:28:06.740Z,1509568086.740 [Rowe_600LCM](FAULT): LCB fault: Software Overcurrent. 2017-11-01T20:28:10.753Z,1509568090.753 [SBIT](IMPORTANT): SBIT PASSED 2017-11-01T20:28:11.130Z,1509568091.130 [MissionManager](IMPORTANT): Started mission Startup 2017-11-01T20:30:38.787Z,1509568238.787 [CBIT](CRITICAL): Communications Fault in component: NAL9602 2017-11-01T20:30:10.613Z,1509568210.613 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-11-01T20:30:17.983Z,1509568217.983 [MissionManager](IMPORTANT): Started mission Default 2017-11-01T20:32:18.204Z,1509568338.204 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-11-01T20:34:22.586Z,1509568462.586 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time.