2017-09-24T16:22:27.395Z,1506270147.395 [Supervisor](FAULT): Ignoring configuration overrides from Data/persisted.cfg 2017-09-24T16:22:32.443Z,1506270152.443 [SBIT](IMPORTANT): git: 2017-04-25-53-gcaea116 2017-09-24T16:22:32.449Z,1506270152.449 [CBIT](FAULT): LAST RESTART WAS UNINTENTIONAL. 2017-09-24T16:22:35.516Z,1506270155.516 [DropWeight](CRITICAL): DROP WEIGHT MISSING. 2017-09-24T16:22:36.036Z,1506270156.036 [BuoyancyServo](FAULT): Buoyancy failed to initialize 2017-09-24T16:22:36.242Z,1506270156.242 [CommandLine](FAULT): Scheduling is paused 2017-09-24T16:22:36.245Z,1506270156.245 [CBIT](CRITICAL): Hardware Fault in component: DropWeight 2017-09-24T16:23:43.904Z,1506270223.904 [SBIT](IMPORTANT): Beginning Startup BIT 2017-09-24T16:23:43.909Z,1506270223.909 [CBIT](IMPORTANT): Beginning ground fault scan 2017-09-24T16:23:54.553Z,1506270234.553 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): -0.010368 CHAN A1 (24V): 0.121423 CHAN A2 (12V): 0.000410 CHAN A3 (5V): 0.000518 CHAN B0 (3.3V): 0.000258 CHAN B1 (3.15aV): 0.000155 CHAN B2 (3.15bV): -0.000514 CHAN B3 (GND): 0.000020 OPEN: 0.005345 Full Scale Calc: 4.765 mA, -1.589 mA 2017-09-24T16:24:33.443Z,1506270273.443 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T16:24:38.012Z,1506270278.012 [SBIT](IMPORTANT): SBIT PASSED 2017-09-24T16:24:38.296Z,1506270278.296 [MissionManager](IMPORTANT): Started mission Startup 2017-09-24T16:26:36.198Z,1506270396.198 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T16:26:38.808Z,1506270398.808 [MissionManager](IMPORTANT): Started mission Default 2017-09-24T16:27:49.700Z,1506270469.700 [NAL9602](FAULT): MT Queue status failed to be acquired within timeout. Will not retry this session. 2017-09-24T16:28:38.538Z,1506270518.538 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T16:28:41.197Z,1506270521.197 [Rowe_600LCM](FAULT): LCB fault: Software Overcurrent. 2017-09-24T16:30:42.740Z,1506270642.740 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time.