SV3 20150824 Short deployment ~4 days. Ran the 'BOG Line' (C1 to M2) twice and came home. A new Wx sensor was installed after this deployment. The thrudder assembly failed after this deployment and was replaced after this deployment. O2 data look good & compare well to nearby M1 o2, except for one brief negative spike which I've removed. pH data are 0.05 - 0.1 unit high compared to predicted from WG pCO2water. Also pH data are up to 0.2 units high compared to nearby M1...I am using the 4/20/2015 calibration, same as the last few deployments, but maybe this is wrong? pCO2 air+water data are reasonable compared to (nearby) M1 pCO2 air+water data, but not 'great.' This deployment corresponded with an underway ship line. pCO2 water compared well. Air temp was way off the whole time; air press was fine for a while then had a prolonged increase to >1030, then spiked back down to normal - I'm deleting the increase event. Lots of spikes in max wind speed too. Eco-Puck returned data over fetch. Also see data summary reports.