2023-12-06T00:07:56.571Z,1701821276.571 [CommandExec](IMPORTANT): got command ubat on 2023-12-06T00:07:56.571Z,1701821276.571 [CommandExec](IMPORTANT): Enabling UBAT. 2023-12-06T00:07:56.571Z,1701821276.571 [CommandExec](IMPORTANT): got command restart logs 2023-12-06T00:08:07.255Z,1701821287.255 [WetLabsUBAT](FAULT): UBAT flow rate is below the specified threshold of 0.05 l/s. 2023-12-06T00:11:33.420Z,1701821493.420 [sci2:Lap:Wpt1:A.Waypoint](IMPORTANT): Navigating to waypoint: 36.750000,-122.022003 2023-12-06T01:02:34.246Z,1701824554.246 [CBIT](IMPORTANT): Beginning ground fault scan 2023-12-06T01:02:45.144Z,1701824565.144 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): 0.019936 CHAN A1 (24V): 0.060486 CHAN A2 (12V): 0.013509 CHAN A3 (5V): -0.003861 CHAN B0 (3.3V): -0.005368 CHAN B1 (3.15aV): -0.006191 CHAN B2 (3.15bV): -0.004792 CHAN B3 (GND): -0.011659 OPEN: 0.002293 Full Scale: +/- 1 mA 2023-12-06T01:13:50.577Z,1701825230.577 [NAL9602](IMPORTANT): SBD MO Status=0, MOMSN=33738, MT Status=1, MTMSN=1901 2023-12-06T01:13:51.604Z,1701825231.604 [CommandExec](IMPORTANT): got command configSet RDI_Pathfinder.loadAtStartup 1 bool persist 2023-12-06T01:13:51.605Z,1701825231.605 [CommandExec](IMPORTANT): configSet RDI_Pathfinder.loadAtStartup requires a restart to take effect. 2023-12-06T01:13:51.611Z,1701825231.611 [CommandExec](IMPORTANT): got command restart application 2023-12-06T01:13:53.012Z,1701825233.012 [MissionManager](IMPORTANT): Started mission Default