2023-08-24T16:28:06.398Z,1692894486.398 [Supervisor](DEBUG): Initializing supervisor.
2023-08-24T16:28:06.402Z,1692894486.402 [SyncHandler](DEBUG): Created PCaller Thread at 404514E0
2023-08-24T16:28:06.402Z,1692894486.402 [SyncHandler](INFO): Protected caller Thread ID is 5533
2023-08-24T16:28:06.403Z,1692894486.403 [ComponentRegistry](DEBUG): Component "controlThread" handled in its own thread.
2023-08-24T16:28:06.404Z,1692894486.404 [controlThread ThreadHandler](DEBUG): Created PCaller Thread at 404814E0
2023-08-24T16:28:06.404Z,1692894486.404 [controlThread ThreadHandler](INFO): Protected caller Thread ID is 5534
2023-08-24T16:28:06.408Z,1692894486.408 [ComponentRegistry](DEBUG): SyncComponent "CycleStarter" handled in the control thread.
2023-08-24T16:28:06.425Z,1692894486.425 [ComponentRegistry](DEBUG): Component "CommandExec" handled in its own thread.
2023-08-24T16:28:06.426Z,1692894486.426 [CommandExec ThreadHandler](DEBUG): Created PCaller Thread at 404B14E0
2023-08-24T16:28:06.426Z,1692894486.426 [CommandExec ThreadHandler](INFO): Protected caller Thread ID is 5535
2023-08-24T16:28:06.430Z,1692894486.430 [ComponentRegistry](DEBUG): Component "CommandLine" handled in its own thread.
2023-08-24T16:28:06.431Z,1692894486.431 [CommandLine ThreadHandler](DEBUG): Created PCaller Thread at 404E14E0
2023-08-24T16:28:06.431Z,1692894486.431 [CommandLine ThreadHandler](INFO): Protected caller Thread ID is 5536
2023-08-24T16:28:06.433Z,1692894486.433 [ComponentRegistry](DEBUG): Component "logger" handled in its own thread.
2023-08-24T16:28:06.434Z,1692894486.434 [logger ThreadHandler](DEBUG): Created PCaller Thread at 405114E0
2023-08-24T16:28:06.435Z,1692894486.435 [logger ThreadHandler](INFO): Protected caller Thread ID is 5537
2023-08-24T16:28:06.438Z,1692894486.438 [ComponentRegistry](DEBUG): SyncComponent "LogSplitter" handled in the control thread.
2023-08-24T16:28:06.439Z,1692894486.439 [Supervisor](INFO): Looking for Config files in directory: Config/
2023-08-24T16:28:06.440Z,1692894486.440 [Supervisor](INFO): Opening Config file at: Config/secure.cfg
2023-08-24T16:28:06.538Z,1692894486.538 [ComponentRegistry](DEBUG): Loaded Config Component "Config/secure
2023-08-24T16:28:06.539Z,1692894486.539 [Supervisor](INFO): Opening Config file at: Config/Sensor.cfg
2023-08-24T16:28:07.211Z,1692894487.211 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Sensor
2023-08-24T16:28:07.212Z,1692894487.212 [Supervisor](INFO): Opening Config file at: Config/Dock.cfg
2023-08-24T16:28:07.425Z,1692894487.425 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Dock
2023-08-24T16:28:07.426Z,1692894487.426 [Supervisor](INFO): Opening Config file at: Config/Sample.cfg
2023-08-24T16:28:07.506Z,1692894487.506 [Supervisor](INFO): Opening Config file at: Config/workSite.cfg
2023-08-24T16:28:07.635Z,1692894487.635 [ComponentRegistry](DEBUG): Loaded Config Component "Config/workSite
2023-08-24T16:28:07.635Z,1692894487.635 [Supervisor](INFO): Opening Config file at: Config/Guidance.cfg
2023-08-24T16:28:07.717Z,1692894487.717 [Supervisor](INFO): Opening Config file at: Config/Estimation.cfg
2023-08-24T16:28:07.826Z,1692894487.826 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Estimation
2023-08-24T16:28:07.826Z,1692894487.826 [Supervisor](INFO): Opening Config file at: Config/Servo.cfg
2023-08-24T16:28:08.198Z,1692894488.198 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Servo
2023-08-24T16:28:08.198Z,1692894488.198 [Supervisor](INFO): Opening Config file at: Config/Simulator.cfg
2023-08-24T16:28:08.670Z,1692894488.670 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Simulator
2023-08-24T16:28:08.671Z,1692894488.671 [Supervisor](INFO): Opening Config file at: Config/Derivation.cfg
2023-08-24T16:28:08.882Z,1692894488.882 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Derivation
2023-08-24T16:28:08.882Z,1692894488.882 [Supervisor](INFO): Opening Config file at: Config/logger.cfg
2023-08-24T16:28:09.067Z,1692894489.067 [ComponentRegistry](DEBUG): Loaded Config Component "Config/logger
2023-08-24T16:28:09.067Z,1692894489.067 [Supervisor](INFO): Opening Config file at: Config/vehicle.cfg
2023-08-24T16:28:09.564Z,1692894489.564 [ComponentRegistry](DEBUG): Loaded Config Component "Config/vehicle
2023-08-24T16:28:09.564Z,1692894489.564 [Supervisor](INFO): Opening Config file at: Config/Navigation.cfg
2023-08-24T16:28:09.851Z,1692894489.851 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Navigation
2023-08-24T16:28:09.852Z,1692894489.852 [Supervisor](INFO): Opening Config file at: Config/BIT.cfg
2023-08-24T16:28:10.069Z,1692894490.069 [ComponentRegistry](DEBUG): Loaded Config Component "Config/BIT
2023-08-24T16:28:10.070Z,1692894490.070 [Supervisor](INFO): Opening Config file at: Config/Science.cfg
2023-08-24T16:28:10.443Z,1692894490.443 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Science
2023-08-24T16:28:10.443Z,1692894490.443 [Supervisor](INFO): Opening Config file at: Config/Control.cfg
2023-08-24T16:28:10.767Z,1692894490.767 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Control
2023-08-24T16:28:10.769Z,1692894490.769 [Supervisor](INFO): Looking for Config files in directory: Config/lrauv-pontus/
2023-08-24T16:28:10.770Z,1692894490.770 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/secure.cfg
2023-08-24T16:28:10.856Z,1692894490.856 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Sensor.cfg
2023-08-24T16:28:11.020Z,1692894491.020 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Servo.cfg
2023-08-24T16:28:11.124Z,1692894491.124 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Simulator.cfg
2023-08-24T16:28:11.212Z,1692894491.212 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/logger.cfg
2023-08-24T16:28:11.309Z,1692894491.309 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/vehicle.cfg
2023-08-24T16:28:11.557Z,1692894491.557 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Battery.cfg
2023-08-24T16:28:12.190Z,1692894492.190 [ComponentRegistry](DEBUG): Loaded Config Component "Config/Battery
2023-08-24T16:28:12.191Z,1692894492.191 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Navigation.cfg
2023-08-24T16:28:12.369Z,1692894492.369 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/BIT.cfg
2023-08-24T16:28:12.806Z,1692894492.806 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Science.cfg
2023-08-24T16:28:13.049Z,1692894493.049 [Supervisor](INFO): Opening Config file at: Config/lrauv-pontus/Control.cfg
2023-08-24T16:28:13.196Z,1692894493.196 [Supervisor](FAULT): Ignoring configuration overrides from Data/persisted.cfg
2023-08-24T16:28:13.197Z,1692894493.197 [Module Loader](DEBUG): Loading Module at Modules/Dock.so
2023-08-24T16:28:13.334Z,1692894493.334 [Module Loader](DEBUG): Loaded Module: Dock (Contains behaviors and commands for docking)
2023-08-24T16:28:13.334Z,1692894493.334 [Module Loader](DEBUG): Loading Module at Modules/Control.so
2023-08-24T16:28:13.407Z,1692894493.407 [VerticalControl](DEBUG): Construct VerticalControl.
2023-08-24T16:28:13.499Z,1692894493.499 [VerticalControl] Loaded
2023-08-24T16:28:13.499Z,1692894493.499 [ComponentRegistry](DEBUG): SyncComponent "VerticalControl" handled in the control thread.
2023-08-24T16:28:13.502Z,1692894493.502 [HorizontalControl](DEBUG): Construct HorizontalControl.
2023-08-24T16:28:13.567Z,1692894493.567 [HorizontalControl] Loaded
2023-08-24T16:28:13.568Z,1692894493.568 [ComponentRegistry](DEBUG): SyncComponent "HorizontalControl" handled in the control thread.
2023-08-24T16:28:13.570Z,1692894493.570 [SpeedControl](DEBUG): Construct SpeedControl.
2023-08-24T16:28:13.573Z,1692894493.573 [SpeedControl] Loaded
2023-08-24T16:28:13.573Z,1692894493.573 [ComponentRegistry](DEBUG): SyncComponent "SpeedControl" handled in the control thread.
2023-08-24T16:28:13.576Z,1692894493.576 [LoopControl](DEBUG): Construct LoopControl.
2023-08-24T16:28:13.576Z,1692894493.576 [LoopControl] Loaded
2023-08-24T16:28:13.576Z,1692894493.576 [ComponentRegistry](DEBUG): SyncComponent "LoopControl" handled in the control thread.
2023-08-24T16:28:13.585Z,1692894493.585 [Module Loader](DEBUG): Loaded Module: Control (Contains the Control components, such as Depth, Heading, and Speed Control)
2023-08-24T16:28:13.586Z,1692894493.586 [Module Loader](DEBUG): Loading Module at Modules/Derivation.so
2023-08-24T16:28:13.657Z,1692894493.657 [DepthRateCalculator] Loaded
2023-08-24T16:28:13.658Z,1692894493.658 [ComponentRegistry](DEBUG): SyncComponent "DepthRateCalculator" handled in the control thread.
2023-08-24T16:28:13.662Z,1692894493.662 [PitchRateCalculator] Loaded
2023-08-24T16:28:13.663Z,1692894493.663 [ComponentRegistry](DEBUG): SyncComponent "PitchRateCalculator" handled in the control thread.
2023-08-24T16:28:13.672Z,1692894493.672 [SpeedCalculator] Loaded
2023-08-24T16:28:13.673Z,1692894493.673 [ComponentRegistry](DEBUG): SyncComponent "SpeedCalculator" handled in the control thread.
2023-08-24T16:28:13.685Z,1692894493.685 [YawRateCalculator] Loaded
2023-08-24T16:28:13.685Z,1692894493.685 [ComponentRegistry](DEBUG): SyncComponent "YawRateCalculator" handled in the control thread.
2023-08-24T16:28:13.712Z,1692894493.712 [ElevatorOffsetCalculator] Loaded
2023-08-24T16:28:13.712Z,1692894493.712 [ComponentRegistry](DEBUG): SyncComponent "ElevatorOffsetCalculator" handled in the control thread.
2023-08-24T16:28:13.712Z,1692894493.712 [Module Loader](DEBUG): Loaded Module: Derivation (Contains the base derivation components)
2023-08-24T16:28:13.713Z,1692894493.713 [Module Loader](DEBUG): Loading Module at Modules/Trigger.so
2023-08-24T16:28:13.755Z,1692894493.755 [Module Loader](DEBUG): Loaded Module: Trigger (Contains triggers for use in missions)
2023-08-24T16:28:13.756Z,1692894493.756 [Module Loader](DEBUG): Loading Module at Modules/Estimation.so
2023-08-24T16:28:13.833Z,1692894493.833 [Module Loader](DEBUG): Loaded Module: Estimation (Contains the base estimation components)
2023-08-24T16:28:13.834Z,1692894493.834 [Module Loader](DEBUG): Loading Module at Modules/Guidance.so
2023-08-24T16:28:14.281Z,1692894494.281 [Module Loader](DEBUG): Loaded Module: Guidance (Contains behaviors and commands)
2023-08-24T16:28:14.282Z,1692894494.282 [Module Loader](DEBUG): Loading Module at Modules/Simulator.so
2023-08-24T16:28:14.488Z,1692894494.488 [Module Loader](DEBUG): Loaded Module: Simulator (This is the module containing the Simulator)
2023-08-24T16:28:14.489Z,1692894494.489 [Module Loader](DEBUG): Loading Module at Modules/Sensor.so
2023-08-24T16:28:15.107Z,1692894495.107 [AHRS_M2] Loaded
2023-08-24T16:28:15.107Z,1692894495.107 [ComponentRegistry](DEBUG): SyncComponent "AHRS_M2" handled in the control thread.
2023-08-24T16:28:15.158Z,1692894495.158 [BackseatComponent] Loaded
2023-08-24T16:28:15.158Z,1692894495.158 [ComponentRegistry](DEBUG): Component "BackseatComponent" handled in its own thread.
2023-08-24T16:28:15.165Z,1692894495.165 [BackseatComponent ThreadHandler](DEBUG): Created PCaller Thread at 4098F4E0
2023-08-24T16:28:15.165Z,1692894495.165 [BackseatComponent ThreadHandler](INFO): Protected caller Thread ID is 5622
2023-08-24T16:28:15.168Z,1692894495.168 [LcmUniversalReporter] Loaded
2023-08-24T16:28:15.168Z,1692894495.168 [ComponentRegistry](DEBUG): SyncComponent "LcmUniversalReporter" handled in the control thread.
2023-08-24T16:28:16.401Z,1692894496.401 [BPC1] Loaded
2023-08-24T16:28:16.401Z,1692894496.401 [ComponentRegistry](DEBUG): SyncComponent "BPC1" handled in the control thread.
2023-08-24T16:28:16.516Z,1692894496.516 [DataOverHttps] Loaded
2023-08-24T16:28:16.516Z,1692894496.516 [ComponentRegistry](DEBUG): Component "DataOverHttps" handled in its own thread.
2023-08-24T16:28:16.517Z,1692894496.517 [DataOverHttps ThreadHandler](DEBUG): Created PCaller Thread at 409BF4E0
2023-08-24T16:28:16.517Z,1692894496.517 [DataOverHttps ThreadHandler](INFO): Protected caller Thread ID is 5623
2023-08-24T16:28:16.546Z,1692894496.546 [Depth_Keller] Loaded
2023-08-24T16:28:16.546Z,1692894496.546 [ComponentRegistry](DEBUG): SyncComponent "Depth_Keller" handled in the control thread.
2023-08-24T16:28:16.551Z,1692894496.551 [DropWeight] Loaded
2023-08-24T16:28:16.551Z,1692894496.551 [ComponentRegistry](DEBUG): SyncComponent "DropWeight" handled in the control thread.
2023-08-24T16:28:16.646Z,1692894496.646 [NAL9602] Loaded
2023-08-24T16:28:16.647Z,1692894496.647 [ComponentRegistry](DEBUG): SyncComponent "NAL9602" handled in the control thread.
2023-08-24T16:28:16.878Z,1692894496.878 [Onboard] Loaded
2023-08-24T16:28:16.878Z,1692894496.878 [ComponentRegistry](DEBUG): Component "Onboard" handled in its own thread.
2023-08-24T16:28:16.879Z,1692894496.879 [Onboard ThreadHandler](DEBUG): Created PCaller Thread at 409EF4E0
2023-08-24T16:28:16.880Z,1692894496.880 [Onboard ThreadHandler](INFO): Protected caller Thread ID is 5624
2023-08-24T16:28:16.922Z,1692894496.922 [PowerOnly](INFO): Adding load control power supply at /dev/loadB1
2023-08-24T16:28:16.941Z,1692894496.941 [PowerOnly] Loaded
2023-08-24T16:28:16.942Z,1692894496.942 [ComponentRegistry](DEBUG): SyncComponent "PowerOnly" handled in the control thread.
2023-08-24T16:28:16.953Z,1692894496.953 [Power24vConverter] Loaded
2023-08-24T16:28:16.954Z,1692894496.954 [ComponentRegistry](DEBUG): SyncComponent "Power24vConverter" handled in the control thread.
2023-08-24T16:28:16.974Z,1692894496.974 [Radio_Surface] Loaded
2023-08-24T16:28:16.993Z,1692894496.993 [ComponentRegistry](DEBUG): Component "Radio_Surface" handled in its own thread.
2023-08-24T16:28:16.994Z,1692894496.994 [Radio_Surface ThreadHandler](DEBUG): Created PCaller Thread at 40A1F4E0
2023-08-24T16:28:16.994Z,1692894496.994 [Radio_Surface ThreadHandler](INFO): Protected caller Thread ID is 5625
2023-08-24T16:28:17.257Z,1692894497.257 [RDI_Pathfinder] Loaded
2023-08-24T16:28:17.258Z,1692894497.258 [ComponentRegistry](DEBUG): SyncComponent "RDI_Pathfinder" handled in the control thread.
2023-08-24T16:28:17.400Z,1692894497.400 [DAT] Loaded
2023-08-24T16:28:17.400Z,1692894497.400 [ComponentRegistry](DEBUG): Component "DAT" handled in its own thread.
2023-08-24T16:28:17.401Z,1692894497.401 [DAT ThreadHandler](DEBUG): Created PCaller Thread at 40A4F4E0
2023-08-24T16:28:17.401Z,1692894497.401 [DAT ThreadHandler](INFO): Protected caller Thread ID is 5627
2023-08-24T16:28:17.402Z,1692894497.402 [Module Loader](DEBUG): Loaded Module: Sensor (Contains the sensor components)
2023-08-24T16:28:17.402Z,1692894497.402 [Module Loader](DEBUG): Loading Module at Modules/Navigation.so
2023-08-24T16:28:17.559Z,1692894497.559 [DeadReckonUsingMultipleVelocitySources] Loaded
2023-08-24T16:28:17.560Z,1692894497.560 [ComponentRegistry](DEBUG): SyncComponent "DeadReckonUsingMultipleVelocitySources" handled in the control thread.
2023-08-24T16:28:17.581Z,1692894497.581 [NavChart] Loaded
2023-08-24T16:28:17.582Z,1692894497.582 [ComponentRegistry](DEBUG): SyncComponent "NavChart" handled in the control thread.
2023-08-24T16:28:17.595Z,1692894497.595 [UniversalFixResidualReporter] Loaded
2023-08-24T16:28:17.596Z,1692894497.596 [ComponentRegistry](DEBUG): SyncComponent "UniversalFixResidualReporter" handled in the control thread.
2023-08-24T16:28:17.596Z,1692894497.596 [Module Loader](DEBUG): Loaded Module: Navigation (Contains the base navigation components)
2023-08-24T16:28:17.597Z,1692894497.597 [Module Loader](DEBUG): Loading Module at Modules/BIT.so
2023-08-24T16:28:17.798Z,1692894497.798 [SBIT](DEBUG): Construct Startup Built In Test.
2023-08-24T16:28:17.815Z,1692894497.815 [SBIT] Loaded
2023-08-24T16:28:17.815Z,1692894497.815 [ComponentRegistry](DEBUG): SyncComponent "SBIT" handled in the control thread.
2023-08-24T16:28:17.818Z,1692894497.818 [IBIT](DEBUG): Construct Initiated Built In Test.
2023-08-24T16:28:17.839Z,1692894497.839 [IBIT] Loaded
2023-08-24T16:28:17.839Z,1692894497.839 [ComponentRegistry](DEBUG): SyncComponent "IBIT" handled in the control thread.
2023-08-24T16:28:17.845Z,1692894497.845 [CBIT](DEBUG): Construct Continuous Built In Test.
2023-08-24T16:28:18.006Z,1692894498.006 [CBIT] Loaded
2023-08-24T16:28:18.006Z,1692894498.006 [ComponentRegistry](DEBUG): SyncComponent "CBIT" handled in the control thread.
2023-08-24T16:28:18.006Z,1692894498.006 [Module Loader](DEBUG): Loaded Module: BIT (Contains the BuiltInTest components, such as C Built In Test)
2023-08-24T16:28:18.007Z,1692894498.007 [Module Loader](DEBUG): Loading Module at Modules/Servo.so
2023-08-24T16:28:18.196Z,1692894498.196 [BuoyancyServo] Loaded
2023-08-24T16:28:18.196Z,1692894498.196 [ComponentRegistry](DEBUG): SyncComponent "BuoyancyServo" handled in the control thread.
2023-08-24T16:28:18.225Z,1692894498.225 [ElevatorServo] Loaded
2023-08-24T16:28:18.225Z,1692894498.225 [ComponentRegistry](DEBUG): SyncComponent "ElevatorServo" handled in the control thread.
2023-08-24T16:28:18.253Z,1692894498.253 [MassServo] Loaded
2023-08-24T16:28:18.253Z,1692894498.253 [ComponentRegistry](DEBUG): SyncComponent "MassServo" handled in the control thread.
2023-08-24T16:28:18.279Z,1692894498.279 [RudderServo] Loaded
2023-08-24T16:28:18.280Z,1692894498.280 [ComponentRegistry](DEBUG): SyncComponent "RudderServo" handled in the control thread.
2023-08-24T16:28:18.313Z,1692894498.313 [ThrusterServo] Loaded
2023-08-24T16:28:18.313Z,1692894498.313 [ComponentRegistry](DEBUG): SyncComponent "ThrusterServo" handled in the control thread.
2023-08-24T16:28:18.314Z,1692894498.314 [Module Loader](DEBUG): Loaded Module: Servo (This is the module containing motor controllers)
2023-08-24T16:28:18.314Z,1692894498.314 [Module Loader](DEBUG): Loading Module at Modules/Sample.so
2023-08-24T16:28:18.324Z,1692894498.324 [Module Loader](DEBUG): Loaded Module: Sample (This is a Sample Module of Sample Components)
2023-08-24T16:28:18.325Z,1692894498.325 [Module Loader](DEBUG): Loading Module at Modules/Science.so
2023-08-24T16:28:18.583Z,1692894498.583 [CTD_Seabird] Loaded
2023-08-24T16:28:18.583Z,1692894498.583 [ComponentRegistry](DEBUG): Component "CTD_Seabird" handled in its own thread.
2023-08-24T16:28:18.589Z,1692894498.589 [CTD_Seabird ThreadHandler](DEBUG): Created PCaller Thread at 40B9A4E0
2023-08-24T16:28:18.589Z,1692894498.589 [CTD_Seabird ThreadHandler](INFO): Protected caller Thread ID is 5628
2023-08-24T16:28:18.618Z,1692894498.618 [PAR_Licor] Loaded
2023-08-24T16:28:18.618Z,1692894498.618 [ComponentRegistry](DEBUG): SyncComponent "PAR_Licor" handled in the control thread.
2023-08-24T16:28:18.675Z,1692894498.675 [WetLabsBB2FL] Loaded
2023-08-24T16:28:18.675Z,1692894498.675 [ComponentRegistry](DEBUG): Component "WetLabsBB2FL" handled in its own thread.
2023-08-24T16:28:18.676Z,1692894498.676 [WetLabsBB2FL ThreadHandler](DEBUG): Created PCaller Thread at 40BCA4E0
2023-08-24T16:28:18.676Z,1692894498.676 [WetLabsBB2FL ThreadHandler](INFO): Protected caller Thread ID is 5629
2023-08-24T16:28:18.704Z,1692894498.704 [WetLabsUBAT] Loaded
2023-08-24T16:28:18.704Z,1692894498.704 [ComponentRegistry](DEBUG): Component "WetLabsUBAT" handled in its own thread.
2023-08-24T16:28:18.713Z,1692894498.713 [WetLabsUBAT ThreadHandler](DEBUG): Created PCaller Thread at 40BFA4E0
2023-08-24T16:28:18.713Z,1692894498.713 [WetLabsUBAT ThreadHandler](INFO): Protected caller Thread ID is 5630
2023-08-24T16:28:18.714Z,1692894498.714 [Module Loader](DEBUG): Loaded Module: Science (Contains the science components)
2023-08-24T16:28:18.720Z,1692894498.720 [ComponentRegistry](DEBUG): SyncComponent "MissionManager" handled in the control thread.
2023-08-24T16:28:18.723Z,1692894498.723 [ComponentRegistry](DEBUG): SyncComponent "Reporter" handled in the control thread.
2023-08-24T16:28:18.743Z,1692894498.743 [ComponentRegistry](DEBUG): Component "NavChartDb" handled in its own thread.
2023-08-24T16:28:18.744Z,1692894498.744 [NavChartDb ThreadHandler](DEBUG): Created PCaller Thread at 40C2A4E0
2023-08-24T16:28:18.744Z,1692894498.744 [NavChartDb ThreadHandler](INFO): Protected caller Thread ID is 5631
2023-08-24T16:28:18.749Z,1692894498.749 [Supervisor](INFO): Main Thread ID is 5532
2023-08-24T16:28:18.749Z,1692894498.749 [Supervisor](DEBUG): Running supervisor.
2023-08-24T16:28:18.757Z,1692894498.757 [CommandExec ThreadHandler](INFO): Handler Thread ID is 5632
2023-08-24T16:28:18.758Z,1692894498.758 [CommandExec](INFO): Initializing the command executive.
2023-08-24T16:28:18.759Z,1692894498.759 [CommandLine ThreadHandler](INFO): Handler Thread ID is 5633
2023-08-24T16:28:18.762Z,1692894498.762 [controlThread ThreadHandler](INFO): Handler Thread ID is 5634
2023-08-24T16:28:18.763Z,1692894498.763 [controlThread](DEBUG): Initializing ControlThread
2023-08-24T16:28:18.764Z,1692894498.764 [VerticalControl](DEBUG): Initialize VerticalControlComponent.
2023-08-24T16:28:18.765Z,1692894498.765 [HorizontalControl](DEBUG): Initialize HorizontalControlComponent.
2023-08-24T16:28:18.766Z,1692894498.766 [SpeedControl](DEBUG): Initialize SpeedControlComponent.
2023-08-24T16:28:18.767Z,1692894498.767 [LoopControl](DEBUG): Initialize LoopControlComponent.
2023-08-24T16:28:18.767Z,1692894498.767 [DepthRateCalculator](DEBUG): Initializing DepthRateCalculator.
2023-08-24T16:28:18.767Z,1692894498.767 [PitchRateCalculator](DEBUG): Initializing PitchRateCalculator.
2023-08-24T16:28:18.767Z,1692894498.767 [SpeedCalculator](DEBUG): Initializing SpeedCalculator.
2023-08-24T16:28:18.768Z,1692894498.768 [YawRateCalculator](DEBUG): Initializing YawRateCalculator.
2023-08-24T16:28:18.768Z,1692894498.768 [ElevatorOffsetCalculator](DEBUG): Initializing ElevatorOffsetCalculator.
2023-08-24T16:28:18.784Z,1692894498.784 [NavChart](DEBUG): Initialize NavChart Navigation.
2023-08-24T16:28:18.784Z,1692894498.784 [UniversalFixResidualReporter](DEBUG): Initializing UniversalFixResidualReporter component.
2023-08-24T16:28:18.785Z,1692894498.785 [SBIT](INFO): Initialize SBIT Component.
2023-08-24T16:28:18.785Z,1692894498.785 [SBIT](IMPORTANT): git: 2023-08-02-8-ga2b2183f7
2023-08-24T16:28:18.785Z,1692894498.785 [SBIT](INFO): git hash: a2b2183f71e07b707bfeaaf571c74c3561721119
2023-08-24T16:28:18.786Z,1692894498.786 [SBIT](IMPORTANT): Kernel Release: 2.6.27.8
2023-08-24T16:28:18.787Z,1692894498.787 [SBIT](INFO): Kernel Reporting Different Version From Configuration.
Kernel Expected: #1 PREEMPT Thu Feb 21 11:17:40 PST 2019
Kernel Reported: #1 PREEMPT Wed Mar 17 08:23:48 PDT 2021
2023-08-24T16:28:18.788Z,1692894498.788 [SBIT](INFO): Beginning SBIT in 49.000000 seconds.
2023-08-24T16:28:18.789Z,1692894498.789 [IBIT](INFO): Initialize IBIT Component.
2023-08-24T16:28:18.790Z,1692894498.790 [CBIT](DEBUG): Initialize CBIT Component.
2023-08-24T16:28:18.790Z,1692894498.790 [logger ThreadHandler](INFO): Handler Thread ID is 5635
2023-08-24T16:28:18.805Z,1692894498.805 [CBIT](DEBUG): Initialized mux pins.
2023-08-24T16:28:18.805Z,1692894498.805 [CBIT](FAULT): LAST RESTART WAS UNINTENTIONAL.
2023-08-24T16:28:18.805Z,1692894498.805 [CBIT](DEBUG): Initializing the watchdog timer.
2023-08-24T16:28:18.818Z,1692894498.818 [BackseatComponent ThreadHandler](INFO): Handler Thread ID is 5636
2023-08-24T16:28:18.829Z,1692894498.829 [CBIT](CRITICAL): Watchdog Timer failed to initialize.
2023-08-24T16:28:18.829Z,1692894498.829 [CBIT] Hardware Fault, FailCount= 1
2023-08-24T16:28:18.829Z,1692894498.829 [CBIT](ERROR): Hardware Fault
2023-08-24T16:28:18.830Z,1692894498.830 [CBIT](DEBUG): Initializing heartbeat.
2023-08-24T16:28:18.834Z,1692894498.834 [DataOverHttps ThreadHandler](INFO): Handler Thread ID is 5637
2023-08-24T16:28:18.834Z,1692894498.834 [DataOverHttps](DEBUG): dashIP=134.89.2.23 starts with a digit so assuming it is a numeric IP
2023-08-24T16:28:18.841Z,1692894498.841 [Onboard ThreadHandler](INFO): Handler Thread ID is 5638
2023-08-24T16:28:18.885Z,1692894498.885 [Radio_Surface ThreadHandler](INFO): Handler Thread ID is 5639
2023-08-24T16:28:18.890Z,1692894498.890 [DAT ThreadHandler](INFO): Handler Thread ID is 5640
2023-08-24T16:28:18.891Z,1692894498.891 [DAT](INFO): Powering up
2023-08-24T16:28:18.891Z,1692894498.891 [DAT](DEBUG): Initializing DAT.
2023-08-24T16:28:18.901Z,1692894498.901 [CBIT](DEBUG): Deactivating GF circuits.
2023-08-24T16:28:18.901Z,1692894498.901 [CBIT](DEBUG): Deactivating emergency mode.
2023-08-24T16:28:18.903Z,1692894498.903 [CTD_Seabird ThreadHandler](INFO): Handler Thread ID is 5642
2023-08-24T16:28:18.903Z,1692894498.903 [CTD_Seabird](DEBUG): Initializing CTD_Seabird.
2023-08-24T16:28:18.909Z,1692894498.909 [WetLabsBB2FL ThreadHandler](INFO): Handler Thread ID is 5644
2023-08-24T16:28:18.914Z,1692894498.914 [WetLabsUBAT ThreadHandler](INFO): Handler Thread ID is 5646
2023-08-24T16:28:18.915Z,1692894498.915 [WetLabsBB2FL](INFO): Powering up
2023-08-24T16:28:18.926Z,1692894498.926 [WetLabsUBAT](INFO): Powering up
2023-08-24T16:28:18.933Z,1692894498.933 [NavChartDb ThreadHandler](INFO): Handler Thread ID is 5648
2023-08-24T16:28:18.936Z,1692894498.936 [NavChartDb](INFO): Looking for Electronic Nav Chart file at: Resources/ElectronicNavigationCharts/US1WC07M.000
2023-08-24T16:28:18.936Z,1692894498.936 [NavChartDb](INFO): Already Loaded Electronic Nav Chart data from US1WC07M.000
2023-08-24T16:28:18.937Z,1692894498.937 [NavChartDb](INFO): Looking for Electronic Nav Chart file at: Resources/ElectronicNavigationCharts/US2WC11M.000
2023-08-24T16:28:18.937Z,1692894498.937 [NavChartDb](INFO): Already Loaded Electronic Nav Chart data from US2WC11M.000
2023-08-24T16:28:18.937Z,1692894498.937 [NavChartDb](INFO): Looking for Electronic Nav Chart file at: Resources/ElectronicNavigationCharts/US3CA52M.000
2023-08-24T16:28:18.937Z,1692894498.937 [NavChartDb](INFO): Already Loaded Electronic Nav Chart data from US3CA52M.000
2023-08-24T16:28:18.937Z,1692894498.937 [NavChartDb](INFO): Looking for Electronic Nav Chart file at: Resources/ElectronicNavigationCharts/US5CA50M.000
2023-08-24T16:28:18.938Z,1692894498.938 [NavChartDb](INFO): Already Loaded Electronic Nav Chart data from US5CA50M.000
2023-08-24T16:28:18.949Z,1692894498.949 [CBIT](DEBUG): Backplane powered.
2023-08-24T16:28:18.982Z,1692894498.982 [MissionManager](INFO): Loading Mission from file: Missions/Startup.xml
2023-08-24T16:28:19.034Z,1692894499.034 [Startup:A.GoToSurface](DEBUG): Construct GoToSurface.
2023-08-24T16:28:19.093Z,1692894499.093 [MissionManager](DEBUG):
2023-08-24T16:28:19.094Z,1692894499.094 [MissionManager](INFO): Loading Mission from file: Missions/Default.xml
2023-08-24T16:28:19.221Z,1692894499.221 [MissionManager](INFO): DefineArg Default.ElapsedSinceDefaultStarted = 0.000000 min
2023-08-24T16:28:19.226Z,1692894499.226 [Default:A.Wait](DEBUG): Construct Wait.
2023-08-24T16:28:19.228Z,1692894499.228 [Default:B.GoToSurface](DEBUG): Construct GoToSurface.
2023-08-24T16:28:19.255Z,1692894499.255 [Default:CheckIn:Read_Iridium:A_Timeout:A.Execute](DEBUG): Construct Execute.
2023-08-24T16:28:19.289Z,1692894499.289 [Radio_Surface](INFO): Powering up
2023-08-24T16:28:19.291Z,1692894499.291 [Default:CheckIn:C.Wait](DEBUG): Construct Wait.
2023-08-24T16:28:19.333Z,1692894499.333 [Default:E.Execute](DEBUG): Construct Execute.
2023-08-24T16:28:19.336Z,1692894499.336 [MissionManager](DEBUG):
0
Wait a moment to see if the scheduler starts a new mission before
starting to actually run Default.
13
Burn on
Dropped weight due to communications timeout.
5
Default mission has been running for
Restarting logs and Default mission.
restart logs
2023-08-24T16:28:19.357Z,1692894499.357 [controlThread](DEBUG): Component order: CycleStarter,AHRS_M2,BPC1,Depth_Keller,DropWeight,NAL9602,PowerOnly,Power24vConverter,RDI_Pathfinder,PAR_Licor,Depth_Keller,PAR_Licor,DepthRateCalculator,PitchRateCalculator,SpeedCalculator,YawRateCalculator,ElevatorOffsetCalculator,DeadReckonUsingMultipleVelocitySources,NavChart,UniversalFixResidualReporter,MissionManager,VerticalControl,HorizontalControl,SpeedControl,LoopControl,BuoyancyServo,ElevatorServo,MassServo,RudderServo,ThrusterServo,SBIT,IBIT,CBIT,LcmUniversalReporter,Reporter,LogSplitter,
2023-08-24T16:28:19.369Z,1692894499.369 [AHRS_M2](DEBUG): Initializing AHRS_M2.
2023-08-24T16:28:19.483Z,1692894499.483 [Depth_Keller](ERROR): Pressure or depth reading out of range: -1.000394 decibar, -0.993016 m
2023-08-24T16:28:19.484Z,1692894499.484 [PowerOnly](INFO): Powering up loadControl
2023-08-24T16:28:19.506Z,1692894499.506 [Power24vConverter](INFO): Powering up.
2023-08-24T16:28:19.506Z,1692894499.506 [RDI_Pathfinder](IMPORTANT): Expecting PD13 message format
2023-08-24T16:28:19.527Z,1692894499.527 [DepthRateCalculator](ERROR): Depth measurement is not active
2023-08-24T16:28:19.586Z,1692894499.586 [BuoyancyServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:19.598Z,1692894499.598 [BuoyancyServo](DEBUG): Initializing BuoyancyServo.
2023-08-24T16:28:19.599Z,1692894499.599 [ElevatorServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:19.622Z,1692894499.622 [ElevatorServo](DEBUG): Initializing ElevatorServo.
2023-08-24T16:28:19.623Z,1692894499.623 [MassServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:19.629Z,1692894499.629 [MassServo](DEBUG): Initializing MassServo.
2023-08-24T16:28:19.630Z,1692894499.630 [RudderServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:19.646Z,1692894499.646 [RudderServo](DEBUG): Initializing RudderServo.
2023-08-24T16:28:19.647Z,1692894499.647 [ThrusterServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:19.657Z,1692894499.657 [ThrusterServo](DEBUG): Initializing ThrusterServo.
2023-08-24T16:28:19.659Z,1692894499.659 [CBIT](DEBUG): Uninitialize CBIT Component.
2023-08-24T16:28:19.659Z,1692894499.659 [CBIT](DEBUG): Powering off loads.
2023-08-24T16:28:19.673Z,1692894499.673 [CBIT](DEBUG): Disabling WDT.
2023-08-24T16:28:19.693Z,1692894499.693 [CBIT](DEBUG): Opening all GF detection circuits.
2023-08-24T16:28:19.850Z,1692894499.850 [DropWeight](CRITICAL): DROP WEIGHT MISSING.
2023-08-24T16:28:19.850Z,1692894499.850 [DropWeight] Hardware Fault, FailCount= 1
2023-08-24T16:28:19.851Z,1692894499.851 [DropWeight](ERROR): Hardware Fault
2023-08-24T16:28:20.981Z,1692894500.981 [BuoyancyServo](ERROR): Buoyancy initialization uart error serial timeout
2023-08-24T16:28:20.981Z,1692894500.981 [BuoyancyServo](FAULT): Buoyancy failed to initialize
2023-08-24T16:28:20.981Z,1692894500.981 [BuoyancyServo] Communications Fault, FailCount= 1
2023-08-24T16:28:20.981Z,1692894500.981 [BuoyancyServo](ERROR): Communications Fault
2023-08-24T16:28:21.289Z,1692894501.289 [ElevatorServo](ERROR): Elevator initialization uart error I:serial timeout
2023-08-24T16:28:21.289Z,1692894501.289 [ElevatorServo](FAULT): Elevator failed to initialize
2023-08-24T16:28:21.289Z,1692894501.289 [ElevatorServo] Communications Fault, FailCount= 1
2023-08-24T16:28:21.290Z,1692894501.290 [ElevatorServo](ERROR): Communications Fault
2023-08-24T16:28:21.601Z,1692894501.601 [RudderServo](ERROR): Rudder initialization uart error serial timeout
2023-08-24T16:28:21.601Z,1692894501.601 [RudderServo](FAULT): Rudder failed to initialize
2023-08-24T16:28:21.601Z,1692894501.601 [RudderServo] Communications Fault, FailCount= 1
2023-08-24T16:28:21.601Z,1692894501.601 [RudderServo](ERROR): Communications Fault
2023-08-24T16:28:21.926Z,1692894501.926 [ThrusterServo](ERROR): Thruster halt for initialization uart error serial timeout
2023-08-24T16:28:22.249Z,1692894502.249 [ThrusterServo](ERROR): Thruster initialization uart error serial timeout
2023-08-24T16:28:22.249Z,1692894502.249 [ThrusterServo](FAULT): Thruster failed to initialize
2023-08-24T16:28:22.249Z,1692894502.249 [ThrusterServo] Communications Fault, FailCount= 1
2023-08-24T16:28:22.249Z,1692894502.249 [ThrusterServo](ERROR): Communications Fault
2023-08-24T16:28:22.316Z,1692894502.316 [ElevatorServo](DEBUG): Uninitialize Elevator Servo.
2023-08-24T16:28:22.333Z,1692894502.333 [ElevatorServo](INFO): Powering down
2023-08-24T16:28:22.645Z,1692894502.645 [MassServo](FAULT): Mass shifter EEPROM initialization uart error serial timeout
2023-08-24T16:28:22.645Z,1692894502.645 [MassServo] Communications Fault, FailCount= 1
2023-08-24T16:28:22.645Z,1692894502.645 [MassServo](ERROR): Communications Fault
2023-08-24T16:28:22.646Z,1692894502.646 [RudderServo](DEBUG): Uninitialize Rudder Servo.
2023-08-24T16:28:22.646Z,1692894502.646 [RudderServo](INFO): Powering down
2023-08-24T16:28:22.647Z,1692894502.647 [ThrusterServo](DEBUG): Uninitialize Thruster Servo.
2023-08-24T16:28:22.647Z,1692894502.647 [ThrusterServo](INFO): Powering down
2023-08-24T16:28:22.751Z,1692894502.751 [MassServo](DEBUG): Uninitialize Mass Servo.
2023-08-24T16:28:22.751Z,1692894502.751 [MassServo](INFO): Powering down
2023-08-24T16:28:22.752Z,1692894502.752 [RudderServo](FAULT): LCB fault: Current Limiter Activated.
2023-08-24T16:28:22.752Z,1692894502.752 [RudderServo] Hardware Fault, FailCount= 1
2023-08-24T16:28:22.752Z,1692894502.752 [RudderServo](ERROR): Hardware Fault
2023-08-24T16:28:23.185Z,1692894503.185 [ElevatorServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:23.319Z,1692894503.319 [ElevatorServo](DEBUG): Initializing ElevatorServo.
2023-08-24T16:28:23.319Z,1692894503.319 [MassServo](FAULT): LCB fault: Current Limiter Activated.
2023-08-24T16:28:23.319Z,1692894503.319 [MassServo] Hardware Fault, FailCount= 1
2023-08-24T16:28:23.320Z,1692894503.320 [MassServo](ERROR): Hardware Fault
2023-08-24T16:28:23.320Z,1692894503.320 [RudderServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:23.439Z,1692894503.439 [RudderServo](DEBUG): Initializing RudderServo.
2023-08-24T16:28:23.658Z,1692894503.658 [MassServo](DEBUG): Initializing EZServoServo.
2023-08-24T16:28:23.774Z,1692894503.774 [MassServo](DEBUG): Initializing MassServo.
2023-08-24T16:28:24.241Z,1692894504.241 [WetLabsBB2FL] Communications Fault, FailCount= 1
2023-08-24T16:28:24.241Z,1692894504.241 [WetLabsBB2FL](ERROR): Communications Fault
2023-08-24T16:28:24.753Z,1692894504.753 [WetLabsBB2FL](INFO): Powering down
2023-08-24T16:28:25.158Z,1692894505.158 [WetLabsBB2FL](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:28:25.158Z,1692894505.158 [WetLabsBB2FL] Hardware Fault, FailCount= 1
2023-08-24T16:28:25.158Z,1692894505.158 [WetLabsBB2FL](ERROR): Hardware Fault
2023-08-24T16:28:27.337Z,1692894507.337 [AHRS_M2](ERROR): Subscribe MagBufferActiveIndex UART error: serial timeout
2023-08-24T16:28:29.259Z,1692894509.259 [AHRS_M2](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:28:29.260Z,1692894509.260 [AHRS_M2] Hardware Fault, FailCount= 1
2023-08-24T16:28:29.260Z,1692894509.260 [AHRS_M2](ERROR): Hardware Fault
2023-08-24T16:28:29.662Z,1692894509.662 [AHRS_M2](INFO): Powering down
2023-08-24T16:28:30.066Z,1692894510.066 [AHRS_M2](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:28:31.981Z,1692894511.981 [CTD_Seabird](FAULT): Failed to initialize within timeout.
2023-08-24T16:28:31.981Z,1692894511.981 [CTD_Seabird] Communications Fault, FailCount= 1
2023-08-24T16:28:31.981Z,1692894511.981 [CTD_Seabird](ERROR): Communications Fault
2023-08-24T16:28:32.386Z,1692894512.386 [CTD_Seabird](INFO): Powering down
2023-08-24T16:28:32.921Z,1692894512.921 [CTD_Seabird](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:28:32.921Z,1692894512.921 [CTD_Seabird] Hardware Fault, FailCount= 1
2023-08-24T16:28:32.921Z,1692894512.921 [CTD_Seabird](ERROR): Hardware Fault
2023-08-24T16:28:40.575Z,1692894520.575 [PowerOnly](FAULT): loadControlLCB fault: Current Limiter Activated.
2023-08-24T16:28:40.575Z,1692894520.575 [PowerOnly] Hardware Fault, FailCount= 1
2023-08-24T16:28:40.575Z,1692894520.575 [PowerOnly](ERROR): Hardware Fault
2023-08-24T16:28:40.978Z,1692894520.978 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:41.383Z,1692894521.383 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:41.786Z,1692894521.786 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:41.788Z,1692894521.788 [RDI_Pathfinder](ERROR): No DVL communication! Re-initializing
2023-08-24T16:28:41.788Z,1692894521.788 [RDI_Pathfinder] Communications Fault, FailCount= 1
2023-08-24T16:28:41.788Z,1692894521.788 [RDI_Pathfinder](ERROR): Communications Fault
2023-08-24T16:28:42.199Z,1692894522.199 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:42.265Z,1692894522.265 [RDI_Pathfinder](INFO): Powering down
2023-08-24T16:28:42.591Z,1692894522.591 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:42.998Z,1692894522.998 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:43.402Z,1692894523.402 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:43.806Z,1692894523.806 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:44.207Z,1692894524.207 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:44.623Z,1692894524.623 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:45.020Z,1692894525.020 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:45.422Z,1692894525.422 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:45.826Z,1692894525.826 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:46.230Z,1692894526.230 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:46.633Z,1692894526.633 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:47.042Z,1692894527.042 [NAL9602](INFO): Powering up NAL9602
2023-08-24T16:28:47.044Z,1692894527.044 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:47.442Z,1692894527.442 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:47.846Z,1692894527.846 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:48.258Z,1692894528.258 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:48.652Z,1692894528.652 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:49.059Z,1692894529.059 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:49.161Z,1692894529.161 [WetLabsUBAT](FAULT): Failed to acquire valid data within specified timeout upon startup.
2023-08-24T16:28:49.161Z,1692894529.161 [WetLabsUBAT] Communications Fault, FailCount= 1
2023-08-24T16:28:49.161Z,1692894529.161 [WetLabsUBAT](ERROR): Communications Fault
2023-08-24T16:28:49.462Z,1692894529.462 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:49.661Z,1692894529.661 [WetLabsUBAT](INFO): Powering down
2023-08-24T16:28:49.866Z,1692894529.866 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:50.065Z,1692894530.065 [WetLabsUBAT](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:28:50.065Z,1692894530.065 [WetLabsUBAT] Hardware Fault, FailCount= 1
2023-08-24T16:28:50.065Z,1692894530.065 [WetLabsUBAT](ERROR): Hardware Fault
2023-08-24T16:28:50.272Z,1692894530.272 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:50.674Z,1692894530.674 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:51.078Z,1692894531.078 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:51.482Z,1692894531.482 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:51.894Z,1692894531.894 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:52.290Z,1692894532.290 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:52.695Z,1692894532.695 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:53.098Z,1692894533.098 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:53.502Z,1692894533.502 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:53.906Z,1692894533.906 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:54.310Z,1692894534.310 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:54.714Z,1692894534.714 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:55.119Z,1692894535.119 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:55.530Z,1692894535.530 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:55.926Z,1692894535.926 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:56.330Z,1692894536.330 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:56.735Z,1692894536.735 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:57.137Z,1692894537.137 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:57.554Z,1692894537.554 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:57.947Z,1692894537.947 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:58.351Z,1692894538.351 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:58.755Z,1692894538.755 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:59.159Z,1692894539.159 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:28:59.563Z,1692894539.563 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:28:59.967Z,1692894539.967 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:00.371Z,1692894540.371 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:00.776Z,1692894540.776 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:01.179Z,1692894541.179 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:01.583Z,1692894541.583 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:01.984Z,1692894541.984 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:02.390Z,1692894542.390 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:02.795Z,1692894542.795 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:03.199Z,1692894543.199 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:03.603Z,1692894543.603 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:04.007Z,1692894544.007 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:04.411Z,1692894544.411 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:04.815Z,1692894544.815 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:05.219Z,1692894545.219 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:05.623Z,1692894545.623 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:06.028Z,1692894546.028 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:06.431Z,1692894546.431 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:06.835Z,1692894546.835 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:07.237Z,1692894547.237 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:07.650Z,1692894547.650 [NAL9602](ERROR): NAL9602 initialization error.
2023-08-24T16:29:07.651Z,1692894547.651 [NAL9602] Communications Fault, FailCount= 1
2023-08-24T16:29:07.651Z,1692894547.651 [NAL9602](ERROR): Communications Fault
2023-08-24T16:29:07.651Z,1692894547.651 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:08.046Z,1692894548.046 [NAL9602](INFO): Powering down
2023-08-24T16:29:08.048Z,1692894548.048 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:08.450Z,1692894548.450 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:08.493Z,1692894548.493 [SBIT](IMPORTANT): Beginning Startup BIT
2023-08-24T16:29:08.855Z,1692894548.855 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:09.258Z,1692894549.258 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:09.662Z,1692894549.662 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:10.066Z,1692894550.066 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:10.468Z,1692894550.468 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:10.874Z,1692894550.874 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:11.280Z,1692894551.280 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:11.686Z,1692894551.686 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:12.086Z,1692894552.086 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:12.491Z,1692894552.491 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:12.900Z,1692894552.900 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:13.295Z,1692894553.295 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:13.702Z,1692894553.702 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:14.103Z,1692894554.103 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:14.512Z,1692894554.512 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:14.914Z,1692894554.914 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:15.316Z,1692894555.316 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:15.726Z,1692894555.726 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:16.128Z,1692894556.128 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:16.534Z,1692894556.534 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:16.938Z,1692894556.938 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:17.338Z,1692894557.338 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:17.746Z,1692894557.746 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:18.143Z,1692894558.143 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:18.550Z,1692894558.550 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:18.906Z,1692894558.906 [DAT](FAULT): failed to initialize, no bytes available on serial interface
2023-08-24T16:29:18.906Z,1692894558.906 [DAT] Communications Fault, FailCount= 1
2023-08-24T16:29:18.906Z,1692894558.906 [DAT](ERROR): Communications Fault
2023-08-24T16:29:18.952Z,1692894558.952 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:19.309Z,1692894559.309 [DAT](INFO): Powering down
2023-08-24T16:29:19.371Z,1692894559.371 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:19.762Z,1692894559.762 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:19.789Z,1692894559.789 [DAT](FAULT): LCB fault: Hardware Overcurrent Shutdown. Current Limiter Activated.
2023-08-24T16:29:19.789Z,1692894559.789 [DAT] Hardware Fault, FailCount= 1
2023-08-24T16:29:19.789Z,1692894559.789 [DAT](ERROR): Hardware Fault
2023-08-24T16:29:20.195Z,1692894560.195 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:20.599Z,1692894560.599 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:20.978Z,1692894560.978 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:21.383Z,1692894561.383 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:21.786Z,1692894561.786 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:21.816Z,1692894561.816 [SBIT](ERROR): Could not read elevatorAngleReader_.
2023-08-24T16:29:21.816Z,1692894561.816 [SBIT](ERROR): Could not read rudderAngleReader_.
2023-08-24T16:29:21.817Z,1692894561.817 [SBIT](ERROR): Could not read massPosReader_.
2023-08-24T16:29:22.187Z,1692894562.187 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:22.590Z,1692894562.590 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:22.996Z,1692894562.996 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:23.399Z,1692894563.399 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:23.806Z,1692894563.806 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:24.205Z,1692894564.205 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:24.612Z,1692894564.612 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:25.012Z,1692894565.012 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:25.418Z,1692894565.418 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:25.823Z,1692894565.823 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:26.226Z,1692894566.226 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:26.630Z,1692894566.630 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:27.038Z,1692894567.038 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:27.442Z,1692894567.442 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:27.846Z,1692894567.846 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:28.246Z,1692894568.246 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:28.654Z,1692894568.654 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:29.054Z,1692894569.054 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:29.462Z,1692894569.462 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:29.868Z,1692894569.868 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:30.266Z,1692894570.266 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:30.674Z,1692894570.674 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:31.078Z,1692894571.078 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:31.528Z,1692894571.528 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:31.881Z,1692894571.881 [BPC1](ERROR): BPC1A: No match for serial number 1717 in BPC1A's battery stick inventory (sticks 1-31 in onboard configuration file).
2023-08-24T16:29:31.888Z,1692894571.888 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:32.350Z,1692894572.350 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:32.714Z,1692894572.714 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:33.107Z,1692894573.107 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:33.515Z,1692894573.515 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:33.909Z,1692894573.909 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:34.310Z,1692894574.310 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:34.712Z,1692894574.712 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:35.114Z,1692894575.114 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:35.518Z,1692894575.518 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:35.920Z,1692894575.920 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:36.324Z,1692894576.324 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:36.731Z,1692894576.731 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:37.132Z,1692894577.132 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:37.536Z,1692894577.536 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:37.944Z,1692894577.944 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:38.344Z,1692894578.344 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:38.750Z,1692894578.750 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:39.155Z,1692894579.155 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:39.562Z,1692894579.562 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:39.962Z,1692894579.962 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:40.366Z,1692894580.366 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:40.770Z,1692894580.770 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:41.174Z,1692894581.174 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:41.578Z,1692894581.578 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:41.982Z,1692894581.982 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:42.390Z,1692894582.390 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:42.790Z,1692894582.790 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:43.196Z,1692894583.196 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:43.648Z,1692894583.648 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:44.014Z,1692894584.014 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:44.418Z,1692894584.418 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:44.830Z,1692894584.830 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:45.219Z,1692894585.219 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:45.675Z,1692894585.675 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:46.035Z,1692894586.035 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:46.443Z,1692894586.443 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:46.846Z,1692894586.846 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:47.238Z,1692894587.238 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:47.638Z,1692894587.638 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:48.046Z,1692894588.046 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:48.452Z,1692894588.452 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:48.462Z,1692894588.462 [SBIT](ERROR): Could not read elevatorAngleReader_.
2023-08-24T16:29:48.462Z,1692894588.462 [SBIT](ERROR): Could not read rudderAngleReader_.
2023-08-24T16:29:48.463Z,1692894588.463 [SBIT](ERROR): Could not read massPosReader_.
2023-08-24T16:29:48.463Z,1692894588.463 [SBIT](FAULT): Control surface position failure.
2023-08-24T16:29:48.850Z,1692894588.850 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:49.258Z,1692894589.258 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:49.662Z,1692894589.662 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:50.064Z,1692894590.064 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:50.464Z,1692894590.464 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:50.870Z,1692894590.870 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:51.274Z,1692894591.274 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:51.682Z,1692894591.682 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:52.082Z,1692894592.082 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:52.490Z,1692894592.490 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:52.894Z,1692894592.894 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:53.298Z,1692894593.298 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:53.698Z,1692894593.698 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:54.102Z,1692894594.102 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:54.510Z,1692894594.510 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:54.910Z,1692894594.910 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:55.315Z,1692894595.315 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:55.768Z,1692894595.768 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:56.127Z,1692894596.127 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:56.539Z,1692894596.539 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:56.950Z,1692894596.950 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:57.339Z,1692894597.339 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:57.738Z,1692894597.738 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:58.146Z,1692894598.146 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:58.546Z,1692894598.546 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:58.950Z,1692894598.950 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:29:59.411Z,1692894599.411 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:29:59.767Z,1692894599.767 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:00.178Z,1692894600.178 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:00.580Z,1692894600.580 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:00.970Z,1692894600.970 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:01.378Z,1692894601.378 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:01.782Z,1692894601.782 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:02.182Z,1692894602.182 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:02.209Z,1692894602.209 [SBIT](ERROR): Could not read elevatorAngleReader_.
2023-08-24T16:30:02.209Z,1692894602.209 [SBIT](ERROR): Could not read rudderAngleReader_.
2023-08-24T16:30:02.209Z,1692894602.209 [SBIT](ERROR): Could not read massPosReader_.
2023-08-24T16:30:02.209Z,1692894602.209 [SBIT](FAULT): Control surface position failure.
2023-08-24T16:30:02.586Z,1692894602.586 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:02.602Z,1692894602.602 [SBIT](CRITICAL): SBIT FAILED
2023-08-24T16:30:02.602Z,1692894602.602 [SBIT](FAULT): Ignoring configuration overrides from Data/persisted.cfg
2023-08-24T16:30:02.988Z,1692894602.988 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:02.995Z,1692894602.995 [MissionManager](IMPORTANT): Started mission Startup
2023-08-24T16:30:02.995Z,1692894602.995 [Startup] Running Loop=1
2023-08-24T16:30:02.996Z,1692894602.996 [Startup](DEBUG): Aggregate::initialize Startup
2023-08-24T16:30:02.996Z,1692894602.996 [Startup:A.GoToSurface] Running Loop=1
2023-08-24T16:30:02.996Z,1692894602.996 [Startup:A.GoToSurface](DEBUG): Initialize GoToSurfaceComponent.
2023-08-24T16:30:02.996Z,1692894602.996 [Startup:A.GoToSurface](DEBUG): No depth rate setting specified. Using default value of nan m/s.
2023-08-24T16:30:02.997Z,1692894602.997 [Startup:A.GoToSurface](DEBUG): No pitch setting specified. Using default value of nan degrees.
2023-08-24T16:30:02.997Z,1692894602.997 [Startup:A.GoToSurface](DEBUG): No speed setting specified. Using default value of 1.000000 m/s.
2023-08-24T16:30:02.998Z,1692894602.998 [Startup:A.GoToSurface](DEBUG): No surface timeout specified. Using default value of 1000.000000 seconds.
2023-08-24T16:30:02.998Z,1692894602.998 [Startup:A.GoToSurface](INFO): Received pitch timeout configuration 60.000000 seconds.
2023-08-24T16:30:02.999Z,1692894602.999 [Startup:StartupSatComms] Running Loop=1
2023-08-24T16:30:02.999Z,1692894602.999 [Startup:StartupSatComms](DEBUG): Aggregate::initialize Startup:StartupSatComms
2023-08-24T16:30:02.000Z,1692894603.000 [Startup:StartupSatComms:A] Running Loop=1
2023-08-24T16:30:03.394Z,1692894603.394 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:03.410Z,1692894603.410 [Startup:StartupSatComms:A](DEBUG): Initialize ReadDataComponent to sense latitude_fix
2023-08-24T16:30:03.804Z,1692894603.804 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:04.202Z,1692894604.202 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:04.610Z,1692894604.610 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:05.014Z,1692894605.014 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:05.420Z,1692894605.420 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:05.818Z,1692894605.818 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:06.226Z,1692894606.226 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:06.630Z,1692894606.630 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:07.032Z,1692894607.032 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:07.438Z,1692894607.438 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:07.888Z,1692894607.888 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:08.247Z,1692894608.247 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:08.663Z,1692894608.663 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:09.062Z,1692894609.062 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:09.454Z,1692894609.454 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:09.866Z,1692894609.866 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:10.266Z,1692894610.266 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:10.674Z,1692894610.674 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:11.074Z,1692894611.074 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:11.478Z,1692894611.478 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:11.878Z,1692894611.878 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:12.287Z,1692894612.287 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:12.743Z,1692894612.743 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:13.096Z,1692894613.096 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:13.510Z,1692894613.510 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:13.914Z,1692894613.914 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:14.310Z,1692894614.310 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:14.710Z,1692894614.710 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:15.114Z,1692894615.114 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:15.515Z,1692894615.515 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:15.922Z,1692894615.922 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:16.327Z,1692894616.327 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:16.727Z,1692894616.727 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:17.131Z,1692894617.131 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:17.534Z,1692894617.534 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:17.942Z,1692894617.942 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:18.346Z,1692894618.346 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:18.750Z,1692894618.750 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:19.150Z,1692894619.150 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:19.171Z,1692894619.171 [DeadReckonUsingMultipleVelocitySources](FAULT): Unable to read the rotation from vehicle frame to navigation frame for more than 120 seconds.
2023-08-24T16:30:19.172Z,1692894619.172 [DeadReckonUsingMultipleVelocitySources] Software Fault, FailCount= 1
2023-08-24T16:30:19.172Z,1692894619.172 [DeadReckonUsingMultipleVelocitySources](ERROR): Software Fault
2023-08-24T16:30:19.558Z,1692894619.558 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:19.962Z,1692894619.962 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:20.366Z,1692894620.366 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:20.820Z,1692894620.820 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:21.175Z,1692894621.175 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:21.587Z,1692894621.587 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:21.995Z,1692894621.995 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:22.388Z,1692894622.388 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:22.786Z,1692894622.786 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:23.194Z,1692894623.194 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:23.598Z,1692894623.598 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:24.002Z,1692894624.002 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:24.406Z,1692894624.406 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:24.810Z,1692894624.810 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:25.210Z,1692894625.210 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:25.618Z,1692894625.618 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:26.074Z,1692894626.074 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:26.428Z,1692894626.428 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:26.842Z,1692894626.842 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:27.247Z,1692894627.247 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:27.634Z,1692894627.634 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:28.036Z,1692894628.036 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:28.446Z,1692894628.446 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:28.846Z,1692894628.846 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:29.255Z,1692894629.255 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:29.654Z,1692894629.654 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:30.062Z,1692894630.062 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:30.466Z,1692894630.466 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:30.871Z,1692894630.871 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:31.270Z,1692894631.270 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:31.678Z,1692894631.678 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:32.078Z,1692894632.078 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:32.483Z,1692894632.483 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:32.886Z,1692894632.886 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:33.294Z,1692894633.294 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:33.695Z,1692894633.695 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:34.155Z,1692894634.155 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:34.528Z,1692894634.528 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:34.922Z,1692894634.922 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:35.326Z,1692894635.326 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:35.714Z,1692894635.714 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:36.118Z,1692894636.118 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:36.526Z,1692894636.526 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:36.930Z,1692894636.930 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:37.330Z,1692894637.330 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:37.736Z,1692894637.736 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:38.138Z,1692894638.138 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:38.546Z,1692894638.546 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:38.950Z,1692894638.950 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:39.408Z,1692894639.408 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:39.759Z,1692894639.759 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:40.167Z,1692894640.167 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:40.578Z,1692894640.578 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:40.970Z,1692894640.970 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:41.368Z,1692894641.368 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:41.774Z,1692894641.774 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:42.182Z,1692894642.182 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:42.586Z,1692894642.586 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:42.991Z,1692894642.991 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:43.390Z,1692894643.390 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:43.798Z,1692894643.798 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:44.198Z,1692894644.198 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:44.603Z,1692894644.603 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:45.010Z,1692894645.010 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:45.414Z,1692894645.414 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:45.814Z,1692894645.814 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:46.218Z,1692894646.218 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:46.622Z,1692894646.622 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:47.030Z,1692894647.030 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:47.489Z,1692894647.489 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:47.846Z,1692894647.846 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:48.254Z,1692894648.254 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:48.660Z,1692894648.660 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:49.050Z,1692894649.050 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:49.450Z,1692894649.450 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:49.860Z,1692894649.860 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:50.258Z,1692894650.258 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:50.667Z,1692894650.667 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:51.066Z,1692894651.066 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:51.472Z,1692894651.472 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:51.874Z,1692894651.874 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:52.335Z,1692894652.335 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:52.694Z,1692894652.694 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:53.102Z,1692894653.102 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:53.506Z,1692894653.506 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:53.898Z,1692894653.898 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:54.298Z,1692894654.298 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:54.706Z,1692894654.706 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:55.111Z,1692894655.111 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:55.514Z,1692894655.514 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:55.915Z,1692894655.915 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:56.318Z,1692894656.318 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:56.723Z,1692894656.723 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:57.130Z,1692894657.130 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:57.534Z,1692894657.534 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:57.938Z,1692894657.938 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:58.342Z,1692894658.342 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:58.742Z,1692894658.742 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:59.150Z,1692894659.150 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:30:59.554Z,1692894659.554 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:30:59.954Z,1692894659.954 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:00.415Z,1692894660.415 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:00.774Z,1692894660.774 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:01.178Z,1692894661.178 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:01.574Z,1692894661.574 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:01.990Z,1692894661.990 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:02.382Z,1692894662.382 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:02.786Z,1692894662.786 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:03.190Z,1692894663.190 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:03.196Z,1692894663.196 [Startup:StartupSatComms:A](INFO): Timed out from 2023-08-24T16:30:02.0Z
2023-08-24T16:31:03.196Z,1692894663.196 [Startup:StartupSatComms:A] Stopped
2023-08-24T16:31:03.197Z,1692894663.197 [Startup:StartupSatComms:B] Running Loop=1
2023-08-24T16:31:03.595Z,1692894663.595 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:03.601Z,1692894663.601 [Startup:StartupSatComms:B](DEBUG): Initialize ReadDataComponent to sense platform_communications
2023-08-24T16:31:04.003Z,1692894664.003 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:04.403Z,1692894664.403 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:04.806Z,1692894664.806 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:05.208Z,1692894665.208 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:05.667Z,1692894665.667 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:06.019Z,1692894666.019 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:06.434Z,1692894666.434 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:06.842Z,1692894666.842 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:07.230Z,1692894667.230 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:07.634Z,1692894667.634 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:08.038Z,1692894668.038 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:08.442Z,1692894668.442 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:08.842Z,1692894668.842 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:09.250Z,1692894669.250 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:09.654Z,1692894669.654 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:10.058Z,1692894670.058 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:10.463Z,1692894670.463 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:10.866Z,1692894670.866 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:11.270Z,1692894671.270 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:11.674Z,1692894671.674 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:12.076Z,1692894672.076 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:12.478Z,1692894672.478 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:12.886Z,1692894672.886 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:13.286Z,1692894673.286 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:13.691Z,1692894673.691 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:14.151Z,1692894674.151 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:14.510Z,1692894674.510 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:14.914Z,1692894674.914 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:15.326Z,1692894675.326 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:15.710Z,1692894675.710 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:16.118Z,1692894676.118 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:16.522Z,1692894676.522 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:16.922Z,1692894676.922 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:17.326Z,1692894677.326 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:17.730Z,1692894677.730 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:18.139Z,1692894678.139 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:18.538Z,1692894678.538 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:19.022Z,1692894679.022 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:19.351Z,1692894679.351 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:19.766Z,1692894679.766 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:20.170Z,1692894680.170 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:20.564Z,1692894680.564 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:20.962Z,1692894680.962 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:21.370Z,1692894681.370 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:21.774Z,1692894681.774 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:22.176Z,1692894682.176 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:22.582Z,1692894682.582 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:22.986Z,1692894682.986 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:23.386Z,1692894683.386 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:23.792Z,1692894683.792 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:24.194Z,1692894684.194 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:24.603Z,1692894684.603 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:25.006Z,1692894685.006 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:25.408Z,1692894685.408 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:25.810Z,1692894685.810 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:26.218Z,1692894686.218 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:26.622Z,1692894686.622 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:27.024Z,1692894687.024 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:27.483Z,1692894687.483 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:27.842Z,1692894687.842 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:28.250Z,1692894688.250 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:28.658Z,1692894688.658 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:29.042Z,1692894689.042 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:29.450Z,1692894689.450 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:29.854Z,1692894689.854 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:30.254Z,1692894690.254 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:30.658Z,1692894690.658 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:31.066Z,1692894691.066 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:31.466Z,1692894691.466 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:31.871Z,1692894691.871 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:32.332Z,1692894692.332 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:32.683Z,1692894692.683 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:33.098Z,1692894693.098 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:33.502Z,1692894693.502 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:33.888Z,1692894693.888 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:34.294Z,1692894694.294 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:34.702Z,1692894694.702 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:35.103Z,1692894695.103 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:35.508Z,1692894695.508 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:35.914Z,1692894695.914 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:36.318Z,1692894696.318 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:36.718Z,1692894696.718 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:37.123Z,1692894697.123 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:37.526Z,1692894697.526 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:37.934Z,1692894697.934 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:38.338Z,1692894698.338 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:38.739Z,1692894698.739 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:39.142Z,1692894699.142 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:39.550Z,1692894699.550 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:39.954Z,1692894699.954 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:40.355Z,1692894700.355 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:40.758Z,1692894700.758 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:41.218Z,1692894701.218 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:41.572Z,1692894701.572 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:41.986Z,1692894701.986 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:42.388Z,1692894702.388 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:42.778Z,1692894702.778 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:43.182Z,1692894703.182 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:43.587Z,1692894703.587 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:43.990Z,1692894703.990 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:44.394Z,1692894704.394 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:44.803Z,1692894704.803 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:45.203Z,1692894705.203 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:45.663Z,1692894705.663 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:46.015Z,1692894706.015 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:46.430Z,1692894706.430 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:46.838Z,1692894706.838 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:47.222Z,1692894707.222 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:47.630Z,1692894707.630 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:48.034Z,1692894708.034 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:48.438Z,1692894708.438 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:48.838Z,1692894708.838 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:49.246Z,1692894709.246 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:49.650Z,1692894709.650 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:50.050Z,1692894710.050 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:50.460Z,1692894710.460 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:50.858Z,1692894710.858 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:51.262Z,1692894711.262 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:51.670Z,1692894711.670 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:52.076Z,1692894712.076 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:52.474Z,1692894712.474 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:52.882Z,1692894712.882 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:53.282Z,1692894713.282 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:53.688Z,1692894713.688 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:54.094Z,1692894714.094 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:54.552Z,1692894714.552 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:54.904Z,1692894714.904 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:55.314Z,1692894715.314 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:55.722Z,1692894715.722 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:56.110Z,1692894716.110 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:56.518Z,1692894716.518 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:56.922Z,1692894716.922 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:57.322Z,1692894717.322 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:57.731Z,1692894717.731 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:58.134Z,1692894718.134 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:58.534Z,1692894718.534 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:58.939Z,1692894718.939 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:31:59.399Z,1692894719.399 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:31:59.752Z,1692894719.752 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:00.159Z,1692894720.159 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:00.570Z,1692894720.570 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:00.958Z,1692894720.958 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:01.360Z,1692894721.360 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:01.771Z,1692894721.771 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:02.170Z,1692894722.170 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:02.580Z,1692894722.580 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:02.978Z,1692894722.978 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:03.386Z,1692894723.386 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:03.391Z,1692894723.391 [Startup:StartupSatComms:B](INFO): Timed out from 2023-08-24T16:31:03.2Z
2023-08-24T16:32:03.391Z,1692894723.391 [Startup:StartupSatComms:B] Stopped
2023-08-24T16:32:03.392Z,1692894723.392 [Startup:StartupSatComms](INFO): Completed Startup:StartupSatComms
2023-08-24T16:32:03.392Z,1692894723.392 [Startup:StartupSatComms] Stopped
2023-08-24T16:32:03.392Z,1692894723.392 [Startup:StartupSatComms](DEBUG): Aggregate::uninitialize Startup:StartupSatComms
2023-08-24T16:32:03.392Z,1692894723.392 [Startup](INFO): Completed Startup
2023-08-24T16:32:03.393Z,1692894723.393 [MissionManager](INFO): Startup is completed.
2023-08-24T16:32:03.393Z,1692894723.393 [MissionManager](INFO): Uninitializing Mission Startup
2023-08-24T16:32:03.393Z,1692894723.393 [Startup] Stopped
2023-08-24T16:32:03.393Z,1692894723.393 [Startup](DEBUG): Aggregate::uninitialize Startup
2023-08-24T16:32:03.393Z,1692894723.393 [Startup:A.GoToSurface] Stopped
2023-08-24T16:32:03.393Z,1692894723.393 [Startup:A.GoToSurface](DEBUG): Uninitialize GoToSurfaceComponent.
2023-08-24T16:32:03.786Z,1692894723.786 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:03.797Z,1692894723.797 [MissionManager](IMPORTANT): Started mission Default
2023-08-24T16:32:03.797Z,1692894723.797 [Default] Running Loop=1
2023-08-24T16:32:03.797Z,1692894723.797 [Default](DEBUG): Aggregate::initialize Default
2023-08-24T16:32:03.797Z,1692894723.797 [Default:B.GoToSurface] Running Loop=1
2023-08-24T16:32:03.797Z,1692894723.797 [Default:B.GoToSurface](DEBUG): Initialize GoToSurfaceComponent.
2023-08-24T16:32:03.798Z,1692894723.798 [Default:B.GoToSurface](DEBUG): No depth rate setting specified. Using default value of nan m/s.
2023-08-24T16:32:03.798Z,1692894723.798 [Default:B.GoToSurface](DEBUG): No pitch setting specified. Using default value of nan degrees.
2023-08-24T16:32:03.798Z,1692894723.798 [Default:B.GoToSurface](DEBUG): No speed setting specified. Using default value of 1.000000 m/s.
2023-08-24T16:32:03.799Z,1692894723.799 [Default:B.GoToSurface](DEBUG): No surface timeout specified. Using default value of 1000.000000 seconds.
2023-08-24T16:32:03.799Z,1692894723.799 [Default:B.GoToSurface](INFO): Received pitch timeout configuration 60.000000 seconds.
2023-08-24T16:32:03.799Z,1692894723.799 [Default:A.Wait] Running Loop=1
2023-08-24T16:32:03.799Z,1692894723.799 [Default:A.Wait](DEBUG): Initialize Wait Component.
2023-08-24T16:32:04.196Z,1692894724.196 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:04.594Z,1692894724.594 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:05.002Z,1692894725.002 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:05.402Z,1692894725.402 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:05.808Z,1692894725.808 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:06.214Z,1692894726.214 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:06.618Z,1692894726.618 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:07.018Z,1692894727.018 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:07.426Z,1692894727.426 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:07.883Z,1692894727.883 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:08.236Z,1692894728.236 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:08.650Z,1692894728.650 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:09.063Z,1692894729.063 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:09.442Z,1692894729.442 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:09.850Z,1692894729.850 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:10.254Z,1692894730.254 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:10.654Z,1692894730.654 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:11.063Z,1692894731.063 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:11.466Z,1692894731.466 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:11.870Z,1692894731.870 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:12.275Z,1692894732.275 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:12.732Z,1692894732.732 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:13.109Z,1692894733.109 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:13.498Z,1692894733.498 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:13.902Z,1692894733.902 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:14.291Z,1692894734.291 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:14.698Z,1692894734.698 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:15.102Z,1692894735.102 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:15.503Z,1692894735.503 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:15.910Z,1692894735.910 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:16.314Z,1692894736.314 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:16.718Z,1692894736.718 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:17.122Z,1692894737.122 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:17.128Z,1692894737.128 [Default:A.Wait](INFO): Done Waiting.
2023-08-24T16:32:17.128Z,1692894737.128 [Default:A.Wait] Stopped
2023-08-24T16:32:17.128Z,1692894737.128 [Default:A.Wait](DEBUG): Uninitialize Wait Component.
2023-08-24T16:32:17.522Z,1692894737.522 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:17.533Z,1692894737.533 [Default:CheckIn] Running Loop=1
2023-08-24T16:32:17.534Z,1692894737.534 [Default:CheckIn](DEBUG): Aggregate::initialize Default:CheckIn
2023-08-24T16:32:17.534Z,1692894737.534 [Default:CheckIn:Read_GPS] Running Loop=1
2023-08-24T16:32:17.932Z,1692894737.932 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:17.941Z,1692894737.941 [Default:CheckIn:Read_GPS](DEBUG): Initialize ReadDataComponent to sense time_fix
2023-08-24T16:32:18.330Z,1692894738.330 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:18.738Z,1692894738.738 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:19.138Z,1692894739.138 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:19.544Z,1692894739.544 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:19.946Z,1692894739.946 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:20.354Z,1692894740.354 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:20.758Z,1692894740.758 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:21.160Z,1692894741.160 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:21.619Z,1692894741.619 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:21.971Z,1692894741.971 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:22.386Z,1692894742.386 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:22.791Z,1692894742.791 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:23.178Z,1692894743.178 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:23.586Z,1692894743.586 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:23.986Z,1692894743.986 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:24.392Z,1692894744.392 [PowerOnly](FAULT): loadControl LCB fault: Current Limiter Activated.
2023-08-24T16:32:24.794Z,1692894744.794 [PowerOnly](INFO): Powering down loadControl
2023-08-24T16:32:25.202Z