##-- file opened 2023-08-13T01:36:37.667Z @01:36:38.10 -> showStatus @01:36:39.72 -> Cmd.loadCartridge -1 @01:36:39.79 Gate.power :main,:ON,limit to 5000mA @01:36:39.81 Gate.power :analytic1,:ON,limit to 5000mA @01:36:39.83 Gate.power :analytic2,:ON,limit to 5000mA @01:36:39.86 Gate.power :analytic3,:ON,limit to 5000mA @01:36:39.90 Powering core bus @01:36:42.61 Archive.configure :default @01:36:43.03 Air.configure :default @01:36:43.12 Lysis1.configure :default @01:36:43.19 Lysis2.configure :default @01:36:43.28 Plunge.configure :default @01:36:43.37 SamplePump.configure :default @01:36:43.46 Toroid.configure :default @01:36:43.55 Carousel.configure :default @01:36:43.65 Pressure.configure :default @01:36:43.74 ExtraPump.configure :default @01:36:43.80 All elf controllers running firmware version 4.83 @01:36:43.83 Gate.power :motor,:ON,limit to 5000mA @01:36:43.97 Archive.home.jog 0 @01:36:44.49 Toroid.home.jog 0 @01:36:44.51 Plunge.home.jog 0 @01:36:44.53 Air.home.jog 0 @01:36:44.57 Carousel.home.jog 0 @01:36:44.59 Lysis2.home.jog 0 @01:36:44.64 Lysis1.home.jog 0 @01:36:45.11 Archive.in :homing @01:36:45.38 Archive.jog 1353 @01:36:45.43 Toroid.in :homing @01:36:45.46 Plunge.in :homing @01:36:45.49 Lysis2.in :homing @01:36:45.53 Air.in :homing @01:36:45.59 Lysis1.in :homing @01:36:45.76 Toroid.jog 596 @01:36:45.81 Plunge.jog 766 @01:36:45.87 Lysis1.jog 1352 @01:36:45.93 Lysis2.jog 1357 @01:36:45.97 Air.jog 156 @01:36:46.51 Air.setRawPosition! 50 @01:36:46.56 Air.seek :home @01:36:46.79 Archive.setRawPosition! 50 @01:36:46.85 Archive.seek :home @01:36:46.93 Plunge.setRawPosition! 50 @01:36:46.97 Air.in :default @01:36:47.07 Plunge.seek :home @01:36:47.17 Archive.in :default @01:36:47.25 Lysis2.setRawPosition! 50 @01:36:47.28 Lysis1.setRawPosition! 50 @01:36:47.38 Lysis1.seek :home @01:36:47.41 Lysis2.seek :home @01:36:47.55 Plunge.in :default @01:36:47.69 Lysis1.in :default @01:36:47.78 Lysis2.in :default @01:36:47.91 Toroid.setRawPosition! 0 @01:36:47.96 Toroid.seek :home @01:36:48.06 Toroid.in :default @01:36:48.15 Toroid.seek :clear @01:36:49.76 Carousel.in :default @01:36:49.90 Carousel.home.seek 16 @01:36:50.15 Selecting Cartridge 15 @01:36:50.38 Carousel.seek 15 @01:36:50.87 Lysis1.in :fast @01:36:50.94 Lysis1.seek :locked @01:36:53.18 Plunge.seek :locked @01:36:53.32 Air.in :fast @01:36:53.39 Air.seek :locked @01:36:54.93 Carousel.reconfigure :locked @01:36:55.59 Mounted archive Cartridge @01:37:11.64 -> Cmd.startFiltering @01:37:11.90 Preparing to filter cartridge 15 @01:37:12.19 Priming sample loop w/100ml, bypass w/10ml @01:37:12.20 SamplePump.setPosition! 0ml @01:37:12.26 Bypass.open @01:37:13.68 Intake.open @01:37:14.42 Sea 17.2m deep (40.1psia) @01:37:14.45 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @01:37:17.03 Vacuum tare is 50% of full scale @01:37:17.18 Intake.close @01:37:17.23 Bypass.close @01:37:17.93 Verifying toroid holds at least 0.6..0.85 of 40.1psia @01:37:17.96 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @01:37:22.53 Toroid pressure rose 1% to 40.4psia @01:37:22.54 Bypass.open @01:37:23.26 Intake.open @01:37:24.71 Pressure.in :default @01:37:24.77 Pressure.hold @01:37:24.96 SamplePump.in :prime @01:37:25.04 SamplePump.seek 10ml,59 seconds @01:37:35.88 Pressure.stop @01:37:35.94 SamplePump.setPosition! 0ml @01:37:35.99 Exhaust.open @01:37:37.42 Bypass.close @01:37:38.88 Pressure.in :default @01:37:38.95 Pressure.hold @01:37:39.07 Sea 17.2m deep (40.0psia) @01:37:39.27 SamplePump.in :prime @01:37:39.34 SamplePump.seek 100ml,5:16 @01:39:25.64 Pressure.stop @01:39:25.72 Bypass.open @01:39:26.39 Intake.close @01:39:27.13 Toroid.in :hold @01:39:27.20 Toroid.seek :crack @01:39:28.96 Toroid.seek :cartridge @01:39:29.94 Toroid.in :default @01:39:30.00 Toroid.seek :clear @01:39:32.06 Exhaust.close @01:39:32.12 Bypass.close @01:39:32.80 Verifying cartridge holds at least 0.65..0.85 of 39.8psia @01:39:32.82 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @01:39:37.40 Cartridge pressure rose 1% to 40.0psia @01:39:37.49 Sampling 2000.0ml @01:39:37.51 SamplePump.setPosition! 0ml @01:39:37.56 Exhaust.open @01:39:38.27 Intake.open @01:39:39.14 Pressure.in :default @01:39:39.21 Pressure.hold @01:39:39.33 Sea 17.2m deep (40.1psia) @01:39:39.35 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @01:39:39.50 SamplePump.in :sample @01:39:39.57 SamplePump.seek 2000ml,2:47:06 @01:39:42.18 Cartridge 15 filtering 1/2000ml at 0.60ml/s with 25.9psi vacuum 19.2m deep (43.1psia) @01:40:42.18 Cartridge 15 filtering 36/2000ml at 0.54ml/s with 19.1psi vacuum 17.1m deep (39.9psia) @01:41:42.19 Cartridge 15 filtering 69/2000ml at 0.53ml/s with 20.5psi vacuum 16.7m deep (39.4psia) @01:42:42.18 Cartridge 15 filtering 101/2000ml at 0.52ml/s with 27.5psi vacuum 14.4m deep (36.0psia) @01:43:42.19 Cartridge 15 filtering 132/2000ml at 0.52ml/s with 21.9psi vacuum 18.8m deep (42.5psia) @01:44:42.19 Cartridge 15 filtering 162/2000ml at 0.48ml/s with 21.9psi vacuum 19.9m deep (44.1psia) @01:45:42.19 Cartridge 15 filtering 190/2000ml at 0.45ml/s with 25.0psi vacuum 17.0m deep (39.9psia) @01:46:42.19 Cartridge 15 filtering 217/2000ml at 0.47ml/s with 23.6psi vacuum 18.9m deep (42.7psia) @01:47:42.19 Cartridge 15 filtering 244/2000ml at 0.42ml/s with 25.4psi vacuum 13.0m deep (33.8psia) @01:48:42.19 Cartridge 15 filtering 269/2000ml at 0.41ml/s with 25.8psi vacuum 16.4m deep (38.9psia) @01:49:42.19 Cartridge 15 filtering 294/2000ml at 0.40ml/s with 25.6psi vacuum 14.0m deep (35.4psia) @01:50:42.19 Cartridge 15 filtering 318/2000ml at 0.38ml/s with 26.2psi vacuum 16.0m deep (38.4psia) @01:51:42.19 Cartridge 15 filtering 342/2000ml at 0.38ml/s with 15.7psi vacuum 21.8m deep (46.9psia) @01:52:42.19 Cartridge 15 filtering 364/2000ml at 0.37ml/s with 26.1psi vacuum 16.4m deep (38.9psia) @01:53:42.19 Cartridge 15 filtering 387/2000ml at 0.35ml/s with 23.4psi vacuum 11.3m deep (31.4psia) @01:54:42.19 Cartridge 15 filtering 408/2000ml at 0.35ml/s with 25.3psi vacuum 16.7m deep (39.3psia) @01:55:42.18 Cartridge 15 filtering 429/2000ml at 0.35ml/s with 20.3psi vacuum 21.1m deep (45.8psia) @01:56:42.53 Cartridge 15 filtering 449/2000ml at 0.36ml/s with 24.0psi vacuum 18.4m deep (41.8psia) @01:57:42.19 Cartridge 15 filtering 469/2000ml at 0.33ml/s with 27.8psi vacuum 14.7m deep (36.5psia) @01:58:42.19 Cartridge 15 filtering 489/2000ml at 0.33ml/s with 17.8psi vacuum 20.6m deep (45.1psia) @01:59:42.19 Cartridge 15 filtering 508/2000ml at 0.34ml/s with 27.0psi vacuum 16.6m deep (39.2psia) @02:00:42.19 Cartridge 15 filtering 526/2000ml at 0.31ml/s with 16.9psi vacuum 19.7m deep (43.8psia) @02:01:42.19 Cartridge 15 filtering 544/2000ml at 0.29ml/s with 24.5psi vacuum 16.5m deep (39.1psia) @02:02:42.19 Cartridge 15 filtering 562/2000ml at 0.29ml/s with 23.0psi vacuum 18.0m deep (41.3psia) @02:03:42.19 Cartridge 15 filtering 579/2000ml at 0.28ml/s with 25.7psi vacuum 15.0m deep (36.9psia) @02:04:42.19 Cartridge 15 filtering 596/2000ml at 0.28ml/s with 23.9psi vacuum 17.5m deep (40.6psia) @02:05:42.19 Cartridge 15 filtering 613/2000ml at 0.26ml/s with 25.0psi vacuum 15.6m deep (37.7psia) @02:06:42.19 Cartridge 15 filtering 629/2000ml at 0.27ml/s with 27.4psi vacuum 14.4m deep (36.0psia) @02:07:42.19 Cartridge 15 filtering 645/2000ml at 0.26ml/s with 18.8psi vacuum 19.0m deep (42.8psia) @02:08:42.19 Cartridge 15 filtering 661/2000ml at 0.26ml/s with 26.6psi vacuum 11.3m deep (31.4psia) @02:09:42.19 Cartridge 15 filtering 676/2000ml at 0.26ml/s with 22.5psi vacuum 18.8m deep (42.5psia) @02:10:42.19 Cartridge 15 filtering 692/2000ml at 0.25ml/s with 21.5psi vacuum 17.0m deep (39.9psia) @02:11:42.18 Cartridge 15 filtering 707/2000ml at 0.27ml/s with 24.9psi vacuum 17.2m deep (40.1psia) @02:12:42.19 Cartridge 15 filtering 721/2000ml at 0.23ml/s with 24.3psi vacuum 14.9m deep (36.7psia) @02:13:42.19 Cartridge 15 filtering 736/2000ml at 0.23ml/s with 23.8psi vacuum 14.8m deep (36.6psia) @02:14:42.19 Cartridge 15 filtering 750/2000ml at 0.25ml/s with 25.8psi vacuum 16.6m deep (39.2psia) @02:15:42.19 Cartridge 15 filtering 764/2000ml at 0.23ml/s with 23.5psi vacuum 17.1m deep (40.0psia) @02:16:42.19 Cartridge 15 filtering 778/2000ml at 0.22ml/s with 24.0psi vacuum 15.0m deep (36.8psia) @02:17:42.19 Cartridge 15 filtering 792/2000ml at 0.21ml/s with 25.9psi vacuum 14.1m deep (35.5psia) @02:18:42.19 Cartridge 15 filtering 805/2000ml at 0.24ml/s with 25.2psi vacuum 17.0m deep (39.9psia) @02:19:42.19 Cartridge 15 filtering 819/2000ml at 0.21ml/s with 25.9psi vacuum 14.5m deep (36.1psia) @02:20:42.19 Cartridge 15 filtering 832/2000ml at 0.22ml/s with 23.5psi vacuum 11.4m deep (31.5psia) @02:21:42.19 Cartridge 15 filtering 845/2000ml at 0.21ml/s with 23.7psi vacuum 13.5m deep (34.7psia) @02:22:42.19 Cartridge 15 filtering 858/2000ml at 0.21ml/s with 27.8psi vacuum 14.2m deep (35.7psia) @02:23:42.19 Cartridge 15 filtering 870/2000ml at 0.20ml/s with 26.3psi vacuum 14.2m deep (35.7psia) @02:24:42.19 Cartridge 15 filtering 883/2000ml at 0.21ml/s with 26.8psi vacuum 15.3m deep (37.3psia) @02:25:42.19 Cartridge 15 filtering 896/2000ml at 0.20ml/s with 26.3psi vacuum 14.1m deep (35.5psia) @02:26:42.19 Cartridge 15 filtering 908/2000ml at 0.22ml/s with 25.2psi vacuum 15.6m deep (37.7psia) @02:27:42.19 Cartridge 15 filtering 920/2000ml at 0.21ml/s with 19.6psi vacuum 19.3m deep (43.2psia) @02:28:42.19 Cartridge 15 filtering 933/2000ml at 0.22ml/s with 24.9psi vacuum 17.5m deep (40.5psia) @02:29:42.19 Cartridge 15 filtering 945/2000ml at 0.20ml/s with 26.2psi vacuum 13.5m deep (34.6psia) @02:30:42.19 Cartridge 15 filtering 957/2000ml at 0.21ml/s with 27.5psi vacuum 14.3m deep (35.8psia) @02:31:03.96 Flow averaged 0.31ml/s over 51:25 @02:31:04.01 Waiting up to 11 seconds for vacuum to reduce from 27.2 to 18.0psi @02:31:04.80 Relieved excess vacuum in .8 seconds @02:31:04.83 SamplePump.seek 2000ml,1:26:58 @02:31:42.18 Cartridge 15 filtering 970/2000ml at 0.21ml/s with 27.5psi vacuum 14.2m deep (35.7psia) @02:32:42.18 Cartridge 15 filtering 982/2000ml at 0.20ml/s with 26.2psi vacuum 15.5m deep (37.6psia) @02:32:44.70 Flow averaged 0.20ml/s over 1:40 @02:32:44.74 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @02:32:45.33 Relieved excess vacuum in .6 seconds @02:32:45.36 SamplePump.seek 2000ml,1:25:16 @02:33:42.18 Cartridge 15 filtering 994/2000ml at 0.21ml/s with 20.4psi vacuum 14.9m deep (36.8psia) @02:33:56.90 Flow averaged 0.20ml/s over 1:12 @02:33:56.94 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @02:33:57.53 Relieved excess vacuum in .6 seconds @02:33:57.57 SamplePump.seek 2000ml,1:24:03 @02:34:42.18 Cartridge 15 filtering 1006/2000ml at 0.21ml/s with 24.7psi vacuum 16.6m deep (39.3psia) @02:34:58.38 Flow averaged 0.20ml/s over 1:01 @02:34:58.42 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @02:34:59.01 Relieved excess vacuum in .6 seconds @02:34:59.04 SamplePump.seek 2000ml,1:23:01 @02:35:42.19 Cartridge 15 filtering 1018/2000ml at 0.20ml/s with 26.3psi vacuum 14.9m deep (36.7psia) @02:35:59.57 Flow averaged 0.20ml/s over 1:01 @02:35:59.61 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @02:36:00.20 Relieved excess vacuum in .6 seconds @02:36:00.23 SamplePump.seek 2000ml,1:22:00 @02:36:30.43 Flow averaged 0.20ml/s over 31 seconds @02:36:30.47 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @02:36:31.08 Relieved excess vacuum in .7 seconds @02:36:31.11 SamplePump.seek 2000ml,1:21:29 @02:36:42.19 Cartridge 15 filtering 1030/2000ml at 0.20ml/s with 22.6psi vacuum 17.3m deep (40.3psia) @02:36:57.10 Flow averaged 0.20ml/s over 26 seconds @02:36:57.14 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @02:36:57.73 Relieved excess vacuum in .6 seconds @02:36:57.76 SamplePump.seek 2000ml,1:21:03 @02:37:36.21 Flow averaged 0.20ml/s over 39 seconds @02:37:36.26 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @02:37:36.84 Relieved excess vacuum in .6 seconds @02:37:36.87 SamplePump.seek 2000ml,1:20:24 @02:37:42.19 Cartridge 15 filtering 1042/2000ml at 0.22ml/s with 27.4psi vacuum 15.0m deep (36.9psia) @02:38:06.05 Flow averaged 0.20ml/s over 30 seconds @02:38:06.09 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @02:38:06.68 Relieved excess vacuum in .6 seconds @02:38:06.71 SamplePump.seek 2000ml,1:19:54 @02:38:24.66 Flow averaged 0.20ml/s over 18 seconds @02:38:24.71 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @02:38:25.29 Relieved excess vacuum in .6 seconds @02:38:25.32 SamplePump.seek 2000ml,1:19:36 @02:38:42.18 Cartridge 15 filtering 1054/2000ml at 0.20ml/s with 26.0psi vacuum 15.8m deep (38.1psia) @02:38:43.82 Flow averaged 0.20ml/s over 19 seconds @02:38:43.86 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @02:38:44.45 Relieved excess vacuum in .6 seconds @02:38:44.48 SamplePump.seek 2000ml,1:19:18 @02:39:04.92 Flow averaged 0.20ml/s over 21 seconds @02:39:04.97 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @02:39:05.56 Relieved excess vacuum in .6 seconds @02:39:05.59 SamplePump.seek 2000ml,1:18:57 @02:39:31.19 Flow averaged 0.20ml/s over 26 seconds @02:39:31.23 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @02:39:31.82 Relieved excess vacuum in .6 seconds @02:39:31.85 SamplePump.seek 2000ml,1:18:31 @02:39:42.18 Cartridge 15 filtering 1065/2000ml at 0.20ml/s with 25.4psi vacuum 16.2m deep (38.7psia) @02:39:44.73 Flow averaged 0.20ml/s over 13 seconds @02:39:44.75 Intake.close @02:39:44.80 Exhaust.close @02:39:45.03 Toroid.in :hold @02:39:45.11 Toroid.seek :bypass @02:39:46.76 Toroid.in :default @02:39:46.84 Toroid.seek :clear @02:39:48.47 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @02:39:48.49 Pressure.stop @02:39:48.69 Sampled 1066.0ml @02:39:50.63 -> Cmd.startProcessing @02:39:51.07 Plunge.seek :reagent @02:39:51.97 Sample loop closed. Ready to Deliver Reagents @02:39:51.99 Archive.seek :sealed @02:39:55.65 Archive.seek :evac @02:40:09.67 delay 1:00 @02:41:09.70 Archive.seek :clear @02:41:26.88 Sample preserved. Puck Full. @02:41:28.02 -> Cmd.stop @02:41:28.11 Carousel.in :default @02:41:28.23 Carousel.home.seek 15 @02:41:28.53 Plunge.seek :locked @02:41:29.56 Air.in :unlocking @02:41:29.69 Air.seek :clear @02:41:29.76 Lysis1.in :unlocking @02:41:29.91 Lysis1.seek :clear @02:41:31.16 Gate.power :motor,:OFF @02:41:31.18 Gate.power :core,:OFF @02:41:31.20 Gate.power :analytic1,:OFF @02:41:31.22 Gate.power :analytic2,:OFF @02:41:31.25 Gate.power :analytic3,:OFF @02:41:31.28 Gate.power :main,:OFF @02:41:31.30 Safely stopped and ready to power off ##-- file closed 2023-08-13T03:34:47.889Z ##-- file opened 2023-08-13T03:34:47.899Z @03:34:48.57 -> showStatus @03:34:50.59 -> Cmd.loadCartridge -1 @03:34:50.65 Gate.power :main,:ON,limit to 5000mA @03:34:50.67 Gate.power :analytic1,:ON,limit to 5000mA @03:34:50.70 Gate.power :analytic2,:ON,limit to 5000mA @03:34:50.72 Gate.power :analytic3,:ON,limit to 5000mA @03:34:50.77 Powering core bus @03:34:53.48 Archive.configure :default @03:34:53.96 Air.configure :default @03:34:54.03 Lysis1.configure :default @03:34:54.09 Lysis2.configure :default @03:34:54.19 Plunge.configure :default @03:34:54.28 SamplePump.configure :default @03:34:54.38 Toroid.configure :default @03:34:54.47 Carousel.configure :default @03:34:54.57 Pressure.configure :default @03:34:54.66 ExtraPump.configure :default @03:34:54.73 All elf controllers running firmware version 4.83 @03:34:54.76 Gate.power :motor,:ON,limit to 5000mA @03:34:54.97 Archive.home.jog 0 @03:34:55.42 Toroid.home.jog 0 @03:34:55.45 Plunge.home.jog 0 @03:34:55.47 Lysis2.home.jog 0 @03:34:55.49 Lysis1.home.jog 0 @03:34:55.53 Air.home.jog 0 @03:34:55.55 Carousel.home.jog 0 @03:34:56.11 Archive.in :homing @03:34:56.31 Archive.jog 1350 @03:34:56.35 Toroid.in :homing @03:34:56.39 Plunge.in :homing @03:34:56.42 Lysis2.in :homing @03:34:56.46 Air.in :homing @03:34:56.51 Lysis1.in :homing @03:34:56.69 Toroid.jog 600 @03:34:56.75 Lysis2.jog 1354 @03:34:56.77 Plunge.jog 758 @03:34:56.80 Lysis1.jog 1348 @03:34:56.88 Air.jog 158 @03:34:57.48 Air.setRawPosition! 50 @03:34:57.53 Air.seek :home @03:34:57.67 Archive.setRawPosition! 50 @03:34:57.71 Archive.seek :home @03:34:57.81 Air.in :default @03:34:57.89 Plunge.setRawPosition! 50 @03:34:57.95 Plunge.seek :home @03:34:58.02 Archive.in :default @03:34:58.12 Lysis2.setRawPosition! 50 @03:34:58.19 Lysis2.seek :home @03:34:58.29 Lysis1.setRawPosition! 50 @03:34:58.31 Plunge.in :default @03:34:58.37 Lysis1.seek :home @03:34:58.53 Lysis2.in :default @03:34:58.72 Lysis1.in :default @03:34:58.96 Toroid.setRawPosition! 0 @03:34:59.00 Toroid.seek :home @03:34:59.09 Toroid.in :default @03:34:59.17 Toroid.seek :clear @03:35:00.78 Carousel.in :default @03:35:00.90 Carousel.home.seek 15 @03:35:01.17 Selecting Cartridge 14 @03:35:01.38 Carousel.seek 14 @03:35:01.87 Lysis1.in :fast @03:35:01.94 Lysis1.seek :locked @03:35:04.23 Plunge.seek :locked @03:35:04.38 Air.in :fast @03:35:04.82 Air.seek :locked @03:35:06.36 Carousel.reconfigure :locked @03:35:07.01 Mounted archive Cartridge @03:35:22.50 -> Cmd.startFiltering @03:35:22.77 Preparing to filter cartridge 14 @03:35:23.11 Priming sample loop w/100ml, bypass w/10ml @03:35:23.12 SamplePump.setPosition! 0ml @03:35:23.18 Bypass.open @03:35:24.60 Intake.open @03:35:25.38 Sea 16.7m deep (39.4psia) @03:35:25.39 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @03:35:27.99 Vacuum tare is 50% of full scale @03:35:28.17 Intake.close @03:35:28.22 Bypass.close @03:35:28.93 Verifying toroid holds at least 0.6..0.85 of 39.3psia @03:35:28.96 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @03:35:33.53 Toroid pressure rose 1% to 39.6psia @03:35:33.54 Bypass.open @03:35:34.24 Intake.open @03:35:35.68 Pressure.in :default @03:35:35.75 Pressure.hold @03:35:35.94 SamplePump.in :prime @03:35:36.01 SamplePump.seek 10ml,59 seconds @03:35:46.86 Pressure.stop @03:35:46.92 SamplePump.setPosition! 0ml @03:35:46.98 Exhaust.open @03:35:48.38 Bypass.close @03:35:49.87 Pressure.in :default @03:35:49.94 Pressure.hold @03:35:50.06 Sea 16.3m deep (38.7psia) @03:35:50.21 SamplePump.in :prime @03:35:50.28 SamplePump.seek 100ml,5:16 @03:37:36.64 Pressure.stop @03:37:36.72 Bypass.open @03:37:37.41 Intake.close @03:37:38.13 Toroid.in :hold @03:37:38.56 Toroid.seek :crack @03:37:40.32 Toroid.seek :cartridge @03:37:41.29 Toroid.in :default @03:37:41.36 Toroid.seek :clear @03:37:43.40 Exhaust.close @03:37:43.43 Bypass.close @03:37:44.15 Verifying cartridge holds at least 0.65..0.85 of 38.5psia @03:37:44.17 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @03:37:48.79 Sampling 2000.0ml @03:37:48.81 SamplePump.setPosition! 0ml @03:37:48.87 Exhaust.open @03:37:49.55 Intake.open @03:37:50.39 Pressure.in :default @03:37:50.46 Pressure.hold @03:37:50.59 Sea 16.2m deep (38.7psia) @03:37:50.60 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @03:37:50.76 SamplePump.in :sample @03:37:50.83 SamplePump.seek 2000ml,2:47:06 @03:37:53.43 Cartridge 14 filtering 1/2000ml at 0.59ml/s with 21.8psi vacuum 17.3m deep (40.3psia) @03:38:53.43 Cartridge 14 filtering 35/2000ml at 0.55ml/s with 26.7psi vacuum 13.4m deep (34.5psia) @03:39:53.43 Cartridge 14 filtering 68/2000ml at 0.52ml/s with 26.1psi vacuum 11.3m deep (31.4psia) @03:40:53.43 Cartridge 14 filtering 100/2000ml at 0.51ml/s with 26.7psi vacuum 14.3m deep (35.9psia) @03:41:53.43 Cartridge 14 filtering 131/2000ml at 0.49ml/s with 25.8psi vacuum 15.6m deep (37.7psia) @03:42:53.43 Cartridge 14 filtering 160/2000ml at 0.49ml/s with 27.0psi vacuum 11.5m deep (31.7psia) @03:43:53.43 Cartridge 14 filtering 188/2000ml at 0.47ml/s with 19.2psi vacuum 21.1m deep (45.8psia) @03:44:53.43 Cartridge 14 filtering 215/2000ml at 0.46ml/s with 25.0psi vacuum 17.0m deep (39.9psia) @03:45:53.43 Cartridge 14 filtering 241/2000ml at 0.44ml/s with 17.7psi vacuum 19.6m deep (43.7psia) @03:46:53.43 Cartridge 14 filtering 267/2000ml at 0.43ml/s with 23.5psi vacuum 17.6m deep (40.7psia) @03:47:53.43 Cartridge 14 filtering 291/2000ml at 0.39ml/s with 25.1psi vacuum 15.2m deep (37.2psia) @03:48:53.43 Cartridge 14 filtering 315/2000ml at 0.40ml/s with 25.3psi vacuum 12.4m deep (33.1psia) @03:49:53.44 Cartridge 14 filtering 339/2000ml at 0.38ml/s with 28.5psi vacuum 13.6m deep (34.8psia) @03:50:53.43 Cartridge 14 filtering 361/2000ml at 0.37ml/s with 25.0psi vacuum 16.1m deep (38.5psia) @03:51:53.43 Cartridge 14 filtering 383/2000ml at 0.36ml/s with 25.8psi vacuum 15.5m deep (37.6psia) @03:52:53.43 Cartridge 14 filtering 405/2000ml at 0.34ml/s with 25.1psi vacuum 15.1m deep (37.0psia) @03:53:53.44 Cartridge 14 filtering 425/2000ml at 0.35ml/s with 26.7psi vacuum 10.6m deep (30.4psia) @03:54:53.82 Cartridge 14 filtering 446/2000ml at 0.32ml/s with 24.8psi vacuum 16.5m deep (39.1psia) @03:55:53.44 Cartridge 14 filtering 466/2000ml at 0.32ml/s with 19.0psi vacuum 16.7m deep (39.4psia) @03:56:53.44 Cartridge 14 filtering 485/2000ml at 0.31ml/s with 23.8psi vacuum 14.4m deep (35.9psia) @03:57:53.44 Cartridge 14 filtering 504/2000ml at 0.30ml/s with 21.6psi vacuum 11.5m deep (31.7psia) @03:58:53.44 Cartridge 14 filtering 522/2000ml at 0.29ml/s with 25.0psi vacuum 14.5m deep (36.1psia) @03:59:53.44 Cartridge 14 filtering 541/2000ml at 0.29ml/s with 25.0psi vacuum 14.4m deep (36.0psia) @04:00:53.43 Cartridge 14 filtering 558/2000ml at 0.32ml/s with 22.4psi vacuum 17.3m deep (40.2psia) @04:01:53.43 Cartridge 14 filtering 576/2000ml at 0.29ml/s with 24.1psi vacuum 16.5m deep (39.1psia) @04:02:53.44 Cartridge 14 filtering 593/2000ml at 0.27ml/s with 24.8psi vacuum 15.1m deep (37.0psia) @04:03:53.44 Cartridge 14 filtering 610/2000ml at 0.30ml/s with 24.6psi vacuum 15.6m deep (37.7psia) @04:04:53.44 Cartridge 14 filtering 626/2000ml at 0.26ml/s with 25.5psi vacuum 14.7m deep (36.5psia) @04:05:53.43 Cartridge 14 filtering 642/2000ml at 0.26ml/s with 25.7psi vacuum 13.9m deep (35.2psia) @04:06:53.44 Cartridge 14 filtering 658/2000ml at 0.26ml/s with 24.9psi vacuum 11.9m deep (32.3psia) @04:07:53.43 Cartridge 14 filtering 674/2000ml at 0.25ml/s with 23.6psi vacuum 13.8m deep (35.1psia) @04:08:53.44 Cartridge 14 filtering 689/2000ml at 0.25ml/s with 26.6psi vacuum 13.8m deep (35.1psia) @04:09:53.44 Cartridge 14 filtering 705/2000ml at 0.23ml/s with 24.7psi vacuum 14.3m deep (35.8psia) @04:10:53.44 Cartridge 14 filtering 720/2000ml at 0.27ml/s with 25.4psi vacuum 16.5m deep (39.1psia) @04:11:53.43 Cartridge 14 filtering 734/2000ml at 0.24ml/s with 26.3psi vacuum 14.8m deep (36.6psia) @04:12:53.44 Cartridge 14 filtering 749/2000ml at 0.24ml/s with 21.0psi vacuum 17.3m deep (40.3psia) @04:13:53.43 Cartridge 14 filtering 763/2000ml at 0.23ml/s with 23.6psi vacuum 14.6m deep (36.2psia) @04:14:53.44 Cartridge 14 filtering 777/2000ml at 0.23ml/s with 25.0psi vacuum 14.9m deep (36.6psia) @04:15:53.43 Cartridge 14 filtering 791/2000ml at 0.22ml/s with 25.2psi vacuum 14.2m deep (35.7psia) @04:16:53.43 Cartridge 14 filtering 805/2000ml at 0.22ml/s with 26.2psi vacuum 13.7m deep (35.0psia) @04:17:53.43 Cartridge 14 filtering 818/2000ml at 0.22ml/s with 23.9psi vacuum 16.0m deep (38.4psia) @04:18:53.44 Cartridge 14 filtering 832/2000ml at 0.21ml/s with 26.5psi vacuum 14.5m deep (36.2psia) @04:19:53.44 Cartridge 14 filtering 845/2000ml at 0.23ml/s with 27.0psi vacuum 15.5m deep (37.5psia) @04:20:53.43 Cartridge 14 filtering 858/2000ml at 0.20ml/s with 23.7psi vacuum 15.4m deep (37.4psia) @04:21:53.43 Cartridge 14 filtering 871/2000ml at 0.24ml/s with 20.4psi vacuum 19.0m deep (42.8psia) @04:22:53.43 Cartridge 14 filtering 883/2000ml at 0.23ml/s with 26.5psi vacuum 14.3m deep (35.9psia) @04:23:53.43 Cartridge 14 filtering 896/2000ml at 0.20ml/s with 23.4psi vacuum 12.5m deep (33.2psia) @04:24:53.43 Cartridge 14 filtering 909/2000ml at 0.20ml/s with 24.9psi vacuum 14.8m deep (36.6psia) @04:25:53.44 Cartridge 14 filtering 921/2000ml at 0.20ml/s with 23.6psi vacuum 11.6m deep (31.8psia) @04:26:53.43 Cartridge 14 filtering 934/2000ml at 0.21ml/s with 25.0psi vacuum 15.6m deep (37.8psia) @04:27:53.44 Cartridge 14 filtering 946/2000ml at 0.20ml/s with 26.3psi vacuum 15.3m deep (37.3psia) @04:28:53.44 Cartridge 14 filtering 958/2000ml at 0.22ml/s with 27.0psi vacuum 15.5m deep (37.7psia) @04:29:53.43 Cartridge 14 filtering 971/2000ml at 0.20ml/s with 25.1psi vacuum 15.9m deep (38.1psia) @04:30:53.83 Cartridge 14 filtering 983/2000ml at 0.20ml/s with 26.8psi vacuum 14.2m deep (35.7psia) @04:30:59.54 Flow averaged 0.31ml/s over 53:09 @04:30:59.58 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @04:31:00.16 Relieved excess vacuum in .6 seconds @04:31:00.19 SamplePump.seek 2000ml,1:25:07 @04:31:53.43 Cartridge 14 filtering 995/2000ml at 0.20ml/s with 25.6psi vacuum 12.9m deep (33.8psia) @04:32:24.03 Flow averaged 0.20ml/s over 1:24 @04:32:24.07 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @04:32:24.65 Relieved excess vacuum in .6 seconds @04:32:24.68 SamplePump.seek 2000ml,1:23:42 @04:32:53.43 Cartridge 14 filtering 1007/2000ml at 0.20ml/s with 26.8psi vacuum 15.1m deep (37.1psia) @04:33:43.30 Flow averaged 0.20ml/s over 1:19 @04:33:43.33 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @04:33:43.92 Relieved excess vacuum in .6 seconds @04:33:43.95 SamplePump.seek 2000ml,1:22:22 @04:33:53.43 Cartridge 14 filtering 1019/2000ml at 0.20ml/s with 25.4psi vacuum 15.7m deep (37.9psia) @04:34:47.43 Flow averaged 0.20ml/s over 1:04 @04:34:47.47 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @04:34:48.10 Relieved excess vacuum in .7 seconds @04:34:48.13 SamplePump.seek 2000ml,1:21:17 @04:34:53.42 Cartridge 14 filtering 1031/2000ml at 0.20ml/s with 25.9psi vacuum 15.6m deep (37.7psia) @04:35:50.81 Flow averaged 0.20ml/s over 1:03 @04:35:50.84 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @04:35:51.43 Relieved excess vacuum in .6 seconds @04:35:51.46 SamplePump.seek 2000ml,1:20:13 @04:35:53.42 Cartridge 14 filtering 1043/2000ml at 0.20ml/s with 25.2psi vacuum 14.1m deep (35.6psia) @04:36:32.36 Flow averaged 0.20ml/s over 41 seconds @04:36:32.40 Waiting up to 11 seconds for vacuum to reduce from 27.2 to 18.0psi @04:36:32.99 Relieved excess vacuum in .6 seconds @04:36:33.01 SamplePump.seek 2000ml,1:19:32 @04:36:53.43 Cartridge 14 filtering 1055/2000ml at 0.23ml/s with 23.7psi vacuum 17.9m deep (41.2psia) @04:37:03.29 Flow averaged 0.20ml/s over 31 seconds @04:37:03.33 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @04:37:03.92 Relieved excess vacuum in .6 seconds @04:37:03.94 SamplePump.seek 2000ml,1:19:01 @04:37:47.14 Flow averaged 0.20ml/s over 44 seconds @04:37:47.19 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @04:37:47.78 Relieved excess vacuum in .6 seconds @04:37:47.80 SamplePump.seek 2000ml,1:18:17 @04:37:53.42 Cartridge 14 filtering 1067/2000ml at 0.20ml/s with 27.5psi vacuum 15.5m deep (37.7psia) @04:38:20.97 Flow averaged 0.20ml/s over 34 seconds @04:38:21.02 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @04:38:21.60 Relieved excess vacuum in .6 seconds @04:38:21.63 SamplePump.seek 2000ml,1:17:44 @04:38:33.91 Flow averaged 0.20ml/s over 13 seconds @04:38:33.93 Intake.close @04:38:34.40 Exhaust.close @04:38:34.60 Toroid.in :hold @04:38:34.68 Toroid.seek :bypass @04:38:36.33 Toroid.in :default @04:38:36.41 Toroid.seek :clear @04:38:38.03 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @04:38:38.05 Pressure.stop @04:38:38.25 Sampled 1075.3ml @04:38:40.24 -> Cmd.startProcessing @04:38:40.69 Plunge.seek :reagent @04:38:41.59 Sample loop closed. Ready to Deliver Reagents @04:38:41.61 Archive.seek :sealed @04:38:45.27 Archive.seek :evac @04:38:59.29 delay 1:00 @04:39:59.32 Archive.seek :clear @04:40:16.50 Sample preserved. Puck Full. @04:40:17.61 -> Cmd.stop @04:40:17.70 Carousel.in :default @04:40:17.82 Carousel.home.seek 14 @04:40:18.13 Plunge.seek :locked @04:40:19.20 Air.in :unlocking @04:40:19.34 Air.seek :clear @04:40:19.39 Lysis1.in :unlocking @04:40:19.57 Lysis1.seek :clear @04:40:20.84 Gate.power :motor,:OFF @04:40:20.85 Gate.power :core,:OFF @04:40:20.87 Gate.power :analytic1,:OFF @04:40:20.90 Gate.power :analytic2,:OFF @04:40:20.92 Gate.power :analytic3,:OFF @04:40:20.94 Gate.power :main,:OFF @04:40:20.97 Safely stopped and ready to power off ##-- file closed 2023-08-13T04:48:28.994Z ##-- file opened 2023-08-13T04:48:28.996Z @04:48:28.98 -> showStatus @04:48:31.00 -> Cmd.loadCartridge -1 @04:48:31.07 Gate.power :main,:ON,limit to 5000mA @04:48:31.09 Gate.power :analytic1,:ON,limit to 5000mA @04:48:31.11 Gate.power :analytic2,:ON,limit to 5000mA @04:48:31.13 Gate.power :analytic3,:ON,limit to 5000mA @04:48:31.19 Powering core bus @04:48:34.24 Archive.configure :default @04:48:34.33 Air.configure :default @04:48:34.40 Lysis1.configure :default @04:48:34.47 Lysis2.configure :default @04:48:34.56 Plunge.configure :default @04:48:34.65 SamplePump.configure :default @04:48:34.75 Toroid.configure :default @04:48:34.84 Carousel.configure :default @04:48:34.94 Pressure.configure :default @04:48:35.03 ExtraPump.configure :default @04:48:35.10 All elf controllers running firmware version 4.83 @04:48:35.13 Gate.power :motor,:ON,limit to 5000mA @04:48:35.57 Lysis2.home.jog 0 @04:48:35.66 Archive.home.jog 0 @04:48:35.70 Lysis1.home.jog 0 @04:48:35.73 Air.home.jog 0 @04:48:36.05 Toroid.home.jog 0 @04:48:36.09 Plunge.home.jog 0 @04:48:36.27 Carousel.home.jog 0 @04:48:36.58 Lysis2.in :homing @04:48:36.62 Air.in :homing @04:48:36.65 Archive.in :homing @04:48:36.69 Lysis1.in :homing @04:48:36.81 Lysis2.jog 1359 @04:48:36.91 Lysis1.jog 1354 @04:48:36.94 Air.jog 161 @04:48:36.98 Archive.jog 1352 @04:48:37.17 Plunge.in :homing @04:48:37.20 Toroid.in :homing @04:48:37.30 Plunge.jog 758 @04:48:37.32 Toroid.jog 600 @04:48:37.47 Air.setRawPosition! 50 @04:48:37.52 Air.seek :home @04:48:37.80 Air.in :default @04:48:38.03 Lysis2.setRawPosition! 50 @04:48:38.08 Lysis2.seek :home @04:48:38.16 Lysis1.setRawPosition! 50 @04:48:38.23 Lysis1.seek :home @04:48:38.32 Plunge.setRawPosition! 50 @04:48:38.35 Archive.setRawPosition! 50 @04:48:38.43 Plunge.seek :home @04:48:38.47 Archive.seek :home @04:48:38.61 Lysis2.in :default @04:48:38.64 Lysis1.in :default @04:48:38.78 Plunge.in :default @04:48:38.88 Archive.in :default @04:48:39.40 Toroid.setRawPosition! 0 @04:48:39.46 Toroid.seek :home @04:48:39.54 Toroid.in :default @04:48:39.61 Toroid.seek :clear @04:48:41.23 Carousel.in :default @04:48:41.36 Carousel.home.seek 14 @04:48:41.62 Selecting Cartridge 13 @04:48:41.84 Carousel.seek 13 @04:48:42.33 Lysis1.in :fast @04:48:42.40 Lysis1.seek :locked @04:48:44.64 Plunge.seek :locked @04:48:44.78 Air.in :fast @04:48:45.21 Air.seek :locked @04:48:46.77 Carousel.reconfigure :locked @04:48:47.42 Mounted archive Cartridge @04:49:02.92 -> Cmd.startFiltering @04:49:03.18 Preparing to filter cartridge 13 @04:49:03.50 Priming sample loop w/100ml, bypass w/10ml @04:49:03.51 SamplePump.setPosition! 0ml @04:49:03.57 Bypass.open @04:49:05.05 Intake.open @04:49:05.80 Sea 16.3m deep (38.8psia) @04:49:05.82 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @04:49:08.40 Vacuum tare is 51% of full scale @04:49:08.54 Intake.close @04:49:08.58 Bypass.close @04:49:09.32 Verifying toroid holds at least 0.6..0.85 of 38.8psia @04:49:09.34 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @04:49:13.92 Bypass.open @04:49:14.64 Intake.open @04:49:16.10 Pressure.in :default @04:49:16.16 Pressure.hold @04:49:16.36 SamplePump.in :prime @04:49:16.43 SamplePump.seek 10ml,59 seconds @04:49:27.29 Pressure.stop @04:49:27.34 SamplePump.setPosition! 0ml @04:49:27.40 Exhaust.open @04:49:28.83 Bypass.close @04:49:30.33 Pressure.in :default @04:49:30.40 Pressure.hold @04:49:30.52 Sea 16.2m deep (38.7psia) @04:49:30.67 SamplePump.in :prime @04:49:30.74 SamplePump.seek 100ml,5:16 @04:51:18.50 Pressure.stop @04:51:18.58 Bypass.open @04:51:19.30 Intake.close @04:51:20.05 Toroid.in :hold @04:51:20.12 Toroid.seek :crack @04:51:22.23 Toroid.seek :cartridge @04:51:23.20 Toroid.in :default @04:51:23.27 Toroid.seek :clear @04:51:25.32 Exhaust.close @04:51:25.37 Bypass.close @04:51:26.11 Verifying cartridge holds at least 0.65..0.85 of 38.7psia @04:51:26.13 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @04:51:30.77 Sampling 2000.0ml @04:51:30.78 SamplePump.setPosition! 0ml @04:51:30.84 Exhaust.open @04:51:31.55 Intake.open @04:51:32.41 Pressure.in :default @04:51:32.48 Pressure.hold @04:51:32.60 Sea 16.2m deep (38.7psia) @04:51:32.61 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @04:51:32.78 SamplePump.in :sample @04:51:32.91 SamplePump.seek 2000ml,2:47:06 @04:51:35.45 Cartridge 13 filtering 1/2000ml at 0.59ml/s with 22.3psi vacuum 18.4m deep (41.8psia) @04:52:35.46 Cartridge 13 filtering 33/2000ml at 0.55ml/s with 21.0psi vacuum 19.6m deep (43.7psia) @04:53:35.46 Cartridge 13 filtering 65/2000ml at 0.51ml/s with 25.8psi vacuum 15.7m deep (37.8psia) @04:54:35.46 Cartridge 13 filtering 96/2000ml at 0.51ml/s with 24.7psi vacuum 17.0m deep (39.8psia) @04:55:35.46 Cartridge 13 filtering 125/2000ml at 0.49ml/s with 22.4psi vacuum 18.6m deep (42.2psia) @04:56:35.46 Cartridge 13 filtering 153/2000ml at 0.48ml/s with 21.9psi vacuum 17.2m deep (40.2psia) @04:57:35.46 Cartridge 13 filtering 181/2000ml at 0.47ml/s with 24.7psi vacuum 17.6m deep (40.6psia) @04:58:35.46 Cartridge 13 filtering 208/2000ml at 0.44ml/s with 21.3psi vacuum 19.7m deep (43.8psia) @04:59:35.46 Cartridge 13 filtering 234/2000ml at 0.43ml/s with 18.4psi vacuum 19.6m deep (43.6psia) @05:00:35.46 Cartridge 13 filtering 259/2000ml at 0.43ml/s with 26.8psi vacuum 15.6m deep (37.7psia) @05:01:35.46 Cartridge 13 filtering 284/2000ml at 0.42ml/s with 26.3psi vacuum 16.3m deep (38.7psia) @05:02:35.45 Cartridge 13 filtering 308/2000ml at 0.39ml/s with 20.7psi vacuum 19.1m deep (43.0psia) @05:03:35.46 Cartridge 13 filtering 332/2000ml at 0.37ml/s with 24.9psi vacuum 12.2m deep (32.7psia) @05:04:35.46 Cartridge 13 filtering 355/2000ml at 0.39ml/s with 28.0psi vacuum 15.1m deep (37.0psia) @05:05:35.46 Cartridge 13 filtering 377/2000ml at 0.37ml/s with 24.6psi vacuum 13.4m deep (34.4psia) @05:06:35.46 Cartridge 13 filtering 400/2000ml at 0.35ml/s with 25.1psi vacuum 13.0m deep (34.0psia) @05:07:35.46 Cartridge 13 filtering 421/2000ml at 0.35ml/s with 26.6psi vacuum 15.2m deep (37.2psia) @05:08:35.83 Cartridge 13 filtering 442/2000ml at 0.37ml/s with 24.7psi vacuum 16.6m deep (39.3psia) @05:09:35.46 Cartridge 13 filtering 463/2000ml at 0.36ml/s with 24.9psi vacuum 15.9m deep (38.2psia) @05:10:35.46 Cartridge 13 filtering 483/2000ml at 0.34ml/s with 23.7psi vacuum 18.5m deep (42.0psia) @05:11:35.46 Cartridge 13 filtering 503/2000ml at 0.35ml/s with 24.4psi vacuum 17.7m deep (40.8psia) @05:12:35.46 Cartridge 13 filtering 523/2000ml at 0.32ml/s with 27.5psi vacuum 14.5m deep (36.2psia) @05:13:35.46 Cartridge 13 filtering 542/2000ml at 0.32ml/s with 20.3psi vacuum 20.1m deep (44.4psia) @05:14:35.46 Cartridge 13 filtering 561/2000ml at 0.30ml/s with 23.3psi vacuum 11.4m deep (31.6psia) @05:15:35.46 Cartridge 13 filtering 580/2000ml at 0.32ml/s with 22.5psi vacuum 19.8m deep (43.9psia) @05:16:35.46 Cartridge 13 filtering 598/2000ml at 0.29ml/s with 23.8psi vacuum 17.5m deep (40.5psia) @05:17:35.46 Cartridge 13 filtering 616/2000ml at 0.30ml/s with 27.1psi vacuum 15.1m deep (37.1psia) @05:18:35.46 Cartridge 13 filtering 634/2000ml at 0.32ml/s with 26.0psi vacuum 15.9m deep (38.1psia) @05:19:35.46 Cartridge 13 filtering 652/2000ml at 0.28ml/s with 23.7psi vacuum 11.3m deep (31.4psia) @05:20:35.46 Cartridge 13 filtering 669/2000ml at 0.27ml/s with 23.5psi vacuum 13.2m deep (34.1psia) @05:21:35.46 Cartridge 13 filtering 686/2000ml at 0.30ml/s with 25.0psi vacuum 18.5m deep (42.0psia) @05:22:35.46 Cartridge 13 filtering 703/2000ml at 0.27ml/s with 22.6psi vacuum 15.6m deep (37.8psia) @05:23:35.46 Cartridge 13 filtering 719/2000ml at 0.27ml/s with 25.4psi vacuum 12.4m deep (33.0psia) @05:24:35.46 Cartridge 13 filtering 736/2000ml at 0.27ml/s with 27.7psi vacuum 14.9m deep (36.7psia) @05:25:35.46 Cartridge 13 filtering 752/2000ml at 0.26ml/s with 23.6psi vacuum 14.8m deep (36.5psia) @05:26:35.46 Cartridge 13 filtering 768/2000ml at 0.27ml/s with 27.3psi vacuum 15.9m deep (38.2psia) @05:27:35.46 Cartridge 13 filtering 784/2000ml at 0.25ml/s with 25.0psi vacuum 12.6m deep (33.3psia) @05:28:35.46 Cartridge 13 filtering 799/2000ml at 0.25ml/s with 26.6psi vacuum 16.0m deep (38.4psia) @05:29:35.46 Cartridge 13 filtering 815/2000ml at 0.25ml/s with 23.8psi vacuum 14.8m deep (36.5psia) @05:30:35.46 Cartridge 13 filtering 830/2000ml at 0.25ml/s with 17.4psi vacuum 17.7m deep (40.9psia) @05:31:35.46 Cartridge 13 filtering 845/2000ml at 0.26ml/s with 24.2psi vacuum 18.6m deep (42.2psia) @05:32:35.46 Cartridge 13 filtering 860/2000ml at 0.24ml/s with 23.8psi vacuum 16.6m deep (39.2psia) @05:33:35.46 Cartridge 13 filtering 875/2000ml at 0.23ml/s with 24.6psi vacuum 16.6m deep (39.2psia) @05:34:35.46 Cartridge 13 filtering 889/2000ml at 0.23ml/s with 23.7psi vacuum 17.6m deep (40.6psia) @05:35:35.46 Cartridge 13 filtering 904/2000ml at 0.23ml/s with 25.6psi vacuum 15.5m deep (37.6psia) @05:36:35.46 Cartridge 13 filtering 918/2000ml at 0.25ml/s with 25.2psi vacuum 17.4m deep (40.5psia) @05:37:35.46 Cartridge 13 filtering 932/2000ml at 0.24ml/s with 14.8psi vacuum 21.9m deep (47.0psia) @05:38:35.46 Cartridge 13 filtering 947/2000ml at 0.23ml/s with 24.4psi vacuum 16.1m deep (38.5psia) @05:39:35.46 Cartridge 13 filtering 960/2000ml at 0.24ml/s with 23.7psi vacuum 18.9m deep (42.7psia) @05:40:35.46 Cartridge 13 filtering 974/2000ml at 0.23ml/s with 27.4psi vacuum 15.5m deep (37.7psia) @05:41:35.46 Cartridge 13 filtering 988/2000ml at 0.23ml/s with 26.7psi vacuum 16.3m deep (38.7psia) @05:42:35.46 Cartridge 13 filtering 1002/2000ml at 0.24ml/s with 24.4psi vacuum 19.0m deep (42.8psia) @05:43:35.46 Cartridge 13 filtering 1015/2000ml at 0.22ml/s with 26.6psi vacuum 16.7m deep (39.4psia) @05:44:35.84 Cartridge 13 filtering 1028/2000ml at 0.24ml/s with 26.5psi vacuum 15.8m deep (38.1psia) @05:45:35.46 Cartridge 13 filtering 1042/2000ml at 0.21ml/s with 21.8psi vacuum 15.1m deep (37.0psia) @05:46:35.46 Cartridge 13 filtering 1055/2000ml at 0.21ml/s with 23.7psi vacuum 17.4m deep (40.4psia) @05:47:35.46 Cartridge 13 filtering 1068/2000ml at 0.20ml/s with 24.0psi vacuum 15.7m deep (37.9psia) @05:48:35.46 Cartridge 13 filtering 1081/2000ml at 0.21ml/s with 26.8psi vacuum 16.4m deep (38.9psia) @05:49:35.46 Cartridge 13 filtering 1094/2000ml at 0.23ml/s with 25.2psi vacuum 17.3m deep (40.3psia) @05:50:35.46 Cartridge 13 filtering 1106/2000ml at 0.21ml/s with 27.9psi vacuum 15.6m deep (37.7psia) @05:51:35.46 Cartridge 13 filtering 1119/2000ml at 0.20ml/s with 27.6psi vacuum 15.3m deep (37.4psia) @05:52:35.46 Cartridge 13 filtering 1132/2000ml at 0.20ml/s with 25.8psi vacuum 16.0m deep (38.3psia) @05:53:35.46 Cartridge 13 filtering 1144/2000ml at 0.21ml/s with 24.9psi vacuum 17.6m deep (40.7psia) @05:54:35.46 Cartridge 13 filtering 1157/2000ml at 0.20ml/s with 22.9psi vacuum 14.7m deep (36.5psia) @05:55:35.46 Cartridge 13 filtering 1169/2000ml at 0.20ml/s with 24.8psi vacuum 15.6m deep (37.8psia) @05:56:35.46 Cartridge 13 filtering 1182/2000ml at 0.20ml/s with 24.3psi vacuum 17.4m deep (40.5psia) @05:57:35.46 Cartridge 13 filtering 1194/2000ml at 0.20ml/s with 25.2psi vacuum 17.4m deep (40.4psia) @05:58:35.46 Cartridge 13 filtering 1206/2000ml at 0.20ml/s with 24.7psi vacuum 17.8m deep (41.0psia) @05:59:35.46 Cartridge 13 filtering 1219/2000ml at 0.20ml/s with 27.5psi vacuum 16.8m deep (39.5psia) @06:00:35.46 Cartridge 13 filtering 1231/2000ml at 0.21ml/s with 21.6psi vacuum 19.8m deep (44.0psia) @06:00:42.86 Flow averaged 0.30ml/s over 1:09:11 @06:00:42.90 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @06:00:43.48 Relieved excess vacuum in .6 seconds @06:00:43.51 SamplePump.seek 2000ml,1:04:26 @06:01:35.45 Cartridge 13 filtering 1243/2000ml at 0.20ml/s with 25.3psi vacuum 14.4m deep (35.9psia) @06:02:35.46 Cartridge 13 filtering 1256/2000ml at 0.20ml/s with 26.0psi vacuum 16.5m deep (39.1psia) @06:03:32.28 Flow averaged 0.21ml/s over 2:49 @06:03:32.32 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @06:03:32.91 Relieved excess vacuum in .6 seconds @06:03:32.94 SamplePump.seek 2000ml,1:01:32 @06:03:35.45 Cartridge 13 filtering 1268/2000ml at 0.21ml/s with 17.2psi vacuum 21.1m deep (45.9psia) @06:04:35.46 Cartridge 13 filtering 1280/2000ml at 0.20ml/s with 23.6psi vacuum 15.7m deep (37.9psia) @06:05:35.46 Cartridge 13 filtering 1293/2000ml at 0.20ml/s with 27.5psi vacuum 16.7m deep (39.4psia) @06:05:55.09 Flow averaged 0.21ml/s over 2:23 @06:05:55.13 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @06:05:55.72 Relieved excess vacuum in .6 seconds @06:05:55.75 SamplePump.seek 2000ml,59:05 @06:06:35.45 Cartridge 13 filtering 1305/2000ml at 0.20ml/s with 25.5psi vacuum 17.6m deep (40.7psia) @06:07:35.46 Cartridge 13 filtering 1317/2000ml at 0.20ml/s with 26.4psi vacuum 16.8m deep (39.6psia) @06:07:56.94 Flow averaged 0.21ml/s over 2:02 @06:07:56.97 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @06:07:57.56 Relieved excess vacuum in .6 seconds @06:07:57.59 SamplePump.seek 2000ml,57:01 @06:08:35.45 Cartridge 13 filtering 1329/2000ml at 0.20ml/s with 26.7psi vacuum 17.7m deep (40.9psia) @06:09:02.49 Flow averaged 0.21ml/s over 1:05 @06:09:02.53 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @06:09:03.12 Relieved excess vacuum in .6 seconds @06:09:03.15 SamplePump.seek 2000ml,55:54 @06:09:35.45 Cartridge 13 filtering 1342/2000ml at 0.21ml/s with 26.1psi vacuum 16.3m deep (38.8psia) @06:10:19.81 Flow averaged 0.21ml/s over 1:17 @06:10:19.85 Waiting up to 11 seconds for vacuum to reduce from 27.4 to 18.0psi @06:10:20.44 Relieved excess vacuum in .6 seconds @06:10:20.47 SamplePump.seek 2000ml,54:35 @06:10:35.45 Cartridge 13 filtering 1354/2000ml at 0.20ml/s with 26.6psi vacuum 16.7m deep (39.4psia) @06:11:06.39 Flow averaged 0.21ml/s over 46 seconds @06:11:06.43 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @06:11:07.02 Relieved excess vacuum in .6 seconds @06:11:07.05 SamplePump.seek 2000ml,53:48 @06:11:35.45 Cartridge 13 filtering 1366/2000ml at 0.22ml/s with 17.3psi vacuum 22.0m deep (47.3psia) @06:11:56.00 Flow averaged 0.21ml/s over 49 seconds @06:11:56.04 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @06:11:56.62 Relieved excess vacuum in .6 seconds @06:11:56.66 SamplePump.seek 2000ml,52:58 @06:12:19.37 Flow averaged 0.20ml/s over 23 seconds @06:12:19.42 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @06:12:20.05 Relieved excess vacuum in .7 seconds @06:12:20.08 SamplePump.seek 2000ml,52:34 @06:12:35.49 Cartridge 13 filtering 1378/2000ml at 0.20ml/s with 25.3psi vacuum 18.0m deep (41.2psia) @06:13:09.87 Flow averaged 0.21ml/s over 50 seconds @06:13:09.92 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @06:13:10.51 Relieved excess vacuum in .6 seconds @06:13:10.54 SamplePump.seek 2000ml,51:43 @06:13:35.45 Cartridge 13 filtering 1390/2000ml at 0.20ml/s with 22.0psi vacuum 15.1m deep (37.0psia) @06:14:02.76 Flow averaged 0.21ml/s over 53 seconds @06:14:02.81 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @06:14:03.39 Relieved excess vacuum in .6 seconds @06:14:03.42 SamplePump.seek 2000ml,50:50 @06:14:34.95 Flow averaged 0.20ml/s over 32 seconds @06:14:34.99 Waiting up to 12 seconds for vacuum to reduce from 27.5 to 18.0psi @06:14:35.45 Cartridge 13 filtering 1402/2000ml at 0.00ml/s with -0.1psi vacuum 16.7m deep (39.4psia) @06:14:35.58 Relieved excess vacuum in .6 seconds @06:14:35.61 SamplePump.seek 2000ml,50:17 @06:14:48.08 Flow averaged 0.20ml/s over 13 seconds @06:14:48.12 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @06:14:48.70 Relieved excess vacuum in .6 seconds @06:14:48.73 SamplePump.seek 2000ml,50:05 @06:15:14.94 Flow averaged 0.20ml/s over 27 seconds @06:15:14.98 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @06:15:15.80 Relieved excess vacuum in .9 seconds @06:15:15.83 SamplePump.seek 2000ml,49:38 @06:15:35.45 Cartridge 13 filtering 1414/2000ml at 0.20ml/s with 27.3psi vacuum 15.8m deep (38.1psia) @06:16:05.60 Flow averaged 0.21ml/s over 50 seconds @06:16:05.65 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @06:16:06.23 Relieved excess vacuum in .6 seconds @06:16:06.26 SamplePump.seek 2000ml,48:47 @06:16:35.01 Flow averaged 0.20ml/s over 29 seconds @06:16:35.05 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @06:16:35.50 Cartridge 13 filtering 1426/2000ml at 0.00ml/s with -0.1psi vacuum 16.8m deep (39.5psia) @06:16:35.64 Relieved excess vacuum in .6 seconds @06:16:35.67 SamplePump.seek 2000ml,48:18 @06:17:03.97 Flow averaged 0.20ml/s over 29 seconds @06:17:04.02 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @06:17:04.65 Relieved excess vacuum in .7 seconds @06:17:04.68 SamplePump.seek 2000ml,47:49 @06:17:26.00 Flow averaged 0.20ml/s over 22 seconds @06:17:26.05 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @06:17:26.63 Relieved excess vacuum in .6 seconds @06:17:26.66 SamplePump.seek 2000ml,47:27 @06:17:35.45 Cartridge 13 filtering 1438/2000ml at 0.20ml/s with 25.7psi vacuum 17.5m deep (40.5psia) @06:17:50.93 Flow averaged 0.20ml/s over 25 seconds @06:17:50.97 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @06:17:51.56 Relieved excess vacuum in .7 seconds @06:17:51.59 SamplePump.seek 2000ml,47:02 @06:18:09.00 Flow averaged 0.20ml/s over 18 seconds @06:18:09.04 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @06:18:09.63 Relieved excess vacuum in .6 seconds @06:18:09.66 SamplePump.seek 2000ml,46:45 @06:18:35.45 Cartridge 13 filtering 1450/2000ml at 0.20ml/s with 26.5psi vacuum 16.7m deep (39.3psia) @06:18:36.40 Flow averaged 0.20ml/s over 27 seconds @06:18:36.44 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @06:18:37.03 Relieved excess vacuum in .6 seconds @06:18:37.06 SamplePump.seek 2000ml,46:18 @06:18:55.69 Flow averaged 0.20ml/s over 19 seconds @06:18:55.74 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @06:18:56.32 Relieved excess vacuum in .6 seconds @06:18:56.35 SamplePump.seek 2000ml,45:59 @06:19:20.33 Flow averaged 0.20ml/s over 24 seconds @06:19:20.37 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @06:19:20.96 Relieved excess vacuum in .6 seconds @06:19:20.99 SamplePump.seek 2000ml,45:34 @06:19:35.44 Cartridge 13 filtering 1462/2000ml at 0.20ml/s with 22.5psi vacuum 13.2m deep (34.1psia) @06:19:41.30 Flow averaged 0.20ml/s over 21 seconds @06:19:41.34 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @06:19:42.29 Relieved excess vacuum in 1 second @06:19:42.32 SamplePump.seek 2000ml,45:14 @06:19:55.96 Flow averaged 0.20ml/s over 14 seconds @06:19:56.01 Waiting up to 11 seconds for vacuum to reduce from 27.4 to 18.0psi @06:19:56.59 Relieved excess vacuum in .6 seconds @06:19:56.62 SamplePump.seek 2000ml,45:00 @06:20:05.95 Flow averaged 0.20ml/s over 10 seconds @06:20:05.97 Intake.close @06:20:06.01 Exhaust.close @06:20:06.27 Toroid.in :hold @06:20:06.34 Toroid.seek :bypass @06:20:08.00 Toroid.in :default @06:20:08.08 Toroid.seek :clear @06:20:09.69 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @06:20:09.71 Pressure.stop @06:20:09.91 Sampled 1467.7ml @06:20:12.04 -> Cmd.startProcessing @06:20:12.49 Plunge.seek :reagent @06:20:13.40 Sample loop closed. Ready to Deliver Reagents @06:20:13.41 Archive.seek :sealed @06:20:17.08 Archive.seek :evac @06:20:31.11 delay 1:00 @06:21:31.14 Archive.seek :clear @06:21:48.31 Sample preserved. Puck Full. @06:21:49.40 -> Cmd.stop @06:21:49.49 Carousel.in :default @06:21:49.62 Carousel.home.seek 13 @06:21:49.93 Plunge.seek :locked @06:21:50.95 Air.in :unlocking @06:21:51.07 Air.seek :clear @06:21:51.12 Lysis1.in :unlocking @06:21:51.29 Lysis1.seek :clear @06:21:52.56 Gate.power :motor,:OFF @06:21:52.58 Gate.power :core,:OFF @06:21:52.60 Gate.power :analytic1,:OFF @06:21:52.63 Gate.power :analytic2,:OFF @06:21:52.65 Gate.power :analytic3,:OFF @06:21:52.68 Gate.power :main,:OFF @06:21:52.70 Safely stopped and ready to power off ##-- file closed 2023-08-13T06:30:05.534Z ##-- file opened 2023-08-13T06:30:05.536Z @06:30:06.02 -> showStatus @06:30:08.04 -> Cmd.loadCartridge -1 @06:30:08.10 Gate.power :main,:ON,limit to 5000mA @06:30:08.13 Gate.power :analytic1,:ON,limit to 5000mA @06:30:08.15 Gate.power :analytic2,:ON,limit to 5000mA @06:30:08.18 Gate.power :analytic3,:ON,limit to 5000mA @06:30:08.22 Powering core bus @06:30:11.29 Archive.configure :default @06:30:11.39 Air.configure :default @06:30:11.46 Lysis1.configure :default @06:30:11.53 Lysis2.configure :default @06:30:11.62 Plunge.configure :default @06:30:11.71 SamplePump.configure :default @06:30:11.80 Toroid.configure :default @06:30:11.90 Carousel.configure :default @06:30:11.99 Pressure.configure :default @06:30:12.08 ExtraPump.configure :default @06:30:12.15 All elf controllers running firmware version 4.83 @06:30:12.18 Gate.power :motor,:ON,limit to 5000mA @06:30:12.37 Archive.home.jog 0 @06:30:12.86 Toroid.home.jog 0 @06:30:12.88 Plunge.home.jog 0 @06:30:12.90 Lysis1.home.jog 0 @06:30:12.94 Carousel.home.jog 0 @06:30:12.99 Lysis2.home.jog 0 @06:30:13.03 Air.home.jog 0 @06:30:13.55 Archive.in :homing @06:30:13.77 Archive.jog 1361 @06:30:13.81 Plunge.in :homing @06:30:13.84 Lysis2.in :homing @06:30:13.89 Lysis1.in :homing @06:30:13.92 Air.in :homing @06:30:13.96 Toroid.in :homing @06:30:14.17 Plunge.jog 763 @06:30:14.21 Lysis2.jog 1362 @06:30:14.24 Toroid.jog 595 @06:30:14.28 Lysis1.jog 1361 @06:30:14.31 Air.jog 163 @06:30:14.87 Air.setRawPosition! 50 @06:30:14.92 Air.seek :home @06:30:15.13 Archive.setRawPosition! 50 @06:30:15.19 Archive.seek :home @06:30:15.29 Plunge.setRawPosition! 50 @06:30:15.31 Air.in :default @06:30:15.39 Plunge.seek :home @06:30:15.51 Lysis2.setRawPosition! 50 @06:30:15.54 Archive.in :default @06:30:15.62 Lysis2.seek :home @06:30:15.74 Plunge.in :default @06:30:15.76 Lysis1.setRawPosition! 50 @06:30:15.85 Lysis1.seek :home @06:30:15.98 Lysis2.in :default @06:30:16.16 Lysis1.in :default @06:30:16.41 Toroid.setRawPosition! 0 @06:30:16.47 Toroid.seek :home @06:30:16.56 Toroid.in :default @06:30:16.64 Toroid.seek :clear @06:30:18.26 Carousel.in :default @06:30:18.39 Carousel.home.seek 13 @06:30:18.71 Selecting Cartridge 12 @06:30:18.93 Carousel.seek 12 @06:30:19.42 Lysis1.in :fast @06:30:19.50 Lysis1.seek :locked @06:30:21.73 Plunge.seek :locked @06:30:22.22 Air.in :fast @06:30:22.29 Air.seek :locked @06:30:23.84 Carousel.reconfigure :locked @06:30:24.50 Mounted archive Cartridge @06:30:39.96 -> Cmd.startFiltering @06:30:40.22 Preparing to filter cartridge 12 @06:30:40.50 Priming sample loop w/100ml, bypass w/10ml @06:30:40.52 SamplePump.setPosition! 0ml @06:30:40.57 Bypass.open @06:30:42.04 Intake.open @06:30:42.80 Sea 16.4m deep (38.9psia) @06:30:42.82 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @06:30:45.40 Vacuum tare is 51% of full scale @06:30:45.55 Intake.close @06:30:45.63 Bypass.close @06:30:46.28 Verifying toroid holds at least 0.6..0.85 of 38.9psia @06:30:46.30 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @06:30:50.88 Bypass.open @06:30:51.57 Intake.open @06:30:53.04 Pressure.in :default @06:30:53.11 Pressure.hold @06:30:53.30 SamplePump.in :prime @06:30:53.38 SamplePump.seek 10ml,59 seconds @06:31:04.22 Pressure.stop @06:31:04.28 SamplePump.setPosition! 0ml @06:31:04.34 Exhaust.open @06:31:05.76 Bypass.close @06:31:07.23 Pressure.in :default @06:31:07.29 Pressure.hold @06:31:07.42 Sea 16.4m deep (39.0psia) @06:31:07.57 SamplePump.in :prime @06:31:07.64 SamplePump.seek 100ml,5:16 @06:32:55.18 Pressure.stop @06:32:55.25 Bypass.open @06:32:55.91 Intake.close @06:32:56.67 Toroid.in :hold @06:32:57.11 Toroid.seek :crack @06:32:58.84 Toroid.seek :cartridge @06:32:59.83 Toroid.in :default @06:32:59.90 Toroid.seek :clear @06:33:01.95 Exhaust.close @06:33:01.99 Bypass.close @06:33:02.71 Verifying cartridge holds at least 0.65..0.85 of 38.9psia @06:33:02.73 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @06:33:07.37 Sampling 2000.0ml @06:33:07.39 SamplePump.setPosition! 0ml @06:33:07.45 Exhaust.open @06:33:08.13 Intake.open @06:33:09.02 Pressure.in :default @06:33:09.09 Pressure.hold @06:33:09.22 Sea 16.3m deep (38.8psia) @06:33:09.23 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @06:33:09.41 SamplePump.in :sample @06:33:09.49 SamplePump.seek 2000ml,2:47:06 @06:33:12.05 Cartridge 12 filtering 1/2000ml at 0.59ml/s with 25.8psi vacuum 16.9m deep (39.7psia) @06:34:12.06 Cartridge 12 filtering 34/2000ml at 0.53ml/s with 19.1psi vacuum 17.8m deep (41.0psia) @06:35:12.06 Cartridge 12 filtering 66/2000ml at 0.54ml/s with 26.5psi vacuum 16.6m deep (39.2psia) @06:36:12.06 Cartridge 12 filtering 98/2000ml at 0.51ml/s with 21.2psi vacuum 16.1m deep (38.4psia) @06:37:12.06 Cartridge 12 filtering 129/2000ml at 0.52ml/s with 26.3psi vacuum 13.2m deep (34.2psia) @06:38:12.06 Cartridge 12 filtering 159/2000ml at 0.51ml/s with 27.1psi vacuum 16.3m deep (38.8psia) @06:39:12.06 Cartridge 12 filtering 188/2000ml at 0.47ml/s with 23.5psi vacuum 16.5m deep (39.1psia) @06:40:12.06 Cartridge 12 filtering 217/2000ml at 0.49ml/s with 24.6psi vacuum 18.1m deep (41.5psia) @06:41:12.06 Cartridge 12 filtering 245/2000ml at 0.45ml/s with 25.4psi vacuum 13.6m deep (34.8psia) @06:42:12.06 Cartridge 12 filtering 272/2000ml at 0.43ml/s with 24.4psi vacuum 11.8m deep (32.1psia) @06:43:12.06 Cartridge 12 filtering 299/2000ml at 0.42ml/s with 24.9psi vacuum 16.8m deep (39.6psia) @06:44:12.05 Cartridge 12 filtering 325/2000ml at 0.42ml/s with 26.2psi vacuum 16.1m deep (38.5psia) @06:45:12.06 Cartridge 12 filtering 350/2000ml at 0.42ml/s with 26.5psi vacuum 15.8m deep (38.0psia) @06:46:12.06 Cartridge 12 filtering 375/2000ml at 0.40ml/s with 25.2psi vacuum 15.2m deep (37.1psia) @06:47:12.06 Cartridge 12 filtering 399/2000ml at 0.40ml/s with 26.9psi vacuum 15.8m deep (38.0psia) @06:48:12.06 Cartridge 12 filtering 423/2000ml at 0.40ml/s with 22.2psi vacuum 18.8m deep (42.5psia) @06:49:12.07 Cartridge 12 filtering 446/2000ml at 0.38ml/s with 25.2psi vacuum 14.1m deep (35.5psia) @06:50:12.43 Cartridge 12 filtering 469/2000ml at 0.37ml/s with 26.5psi vacuum 15.3m deep (37.3psia) @06:51:12.06 Cartridge 12 filtering 491/2000ml at 0.36ml/s with 27.4psi vacuum 15.2m deep (37.2psia) @06:52:12.06 Cartridge 12 filtering 513/2000ml at 0.35ml/s with 23.8psi vacuum 11.4m deep (31.5psia) @06:53:12.06 Cartridge 12 filtering 535/2000ml at 0.37ml/s with 21.3psi vacuum 21.0m deep (45.8psia) @06:54:12.06 Cartridge 12 filtering 556/2000ml at 0.34ml/s with 26.6psi vacuum 15.5m deep (37.6psia) @06:55:12.06 Cartridge 12 filtering 576/2000ml at 0.36ml/s with 25.7psi vacuum 18.3m deep (41.8psia) @06:56:12.06 Cartridge 12 filtering 597/2000ml at 0.32ml/s with 25.1psi vacuum 16.2m deep (38.6psia) @06:57:12.06 Cartridge 12 filtering 617/2000ml at 0.35ml/s with 26.0psi vacuum 18.0m deep (41.2psia) @06:58:12.06 Cartridge 12 filtering 636/2000ml at 0.31ml/s with 24.9psi vacuum 16.6m deep (39.2psia) @06:59:12.06 Cartridge 12 filtering 655/2000ml at 0.32ml/s with 25.2psi vacuum 17.6m deep (40.7psia) @07:00:12.06 Cartridge 12 filtering 674/2000ml at 0.31ml/s with 24.3psi vacuum 17.6m deep (40.8psia) @07:01:12.06 Cartridge 12 filtering 693/2000ml at 0.29ml/s with 23.3psi vacuum 11.9m deep (32.3psia) @07:02:12.06 Cartridge 12 filtering 711/2000ml at 0.32ml/s with 27.3psi vacuum 16.7m deep (39.3psia) @07:03:12.06 Cartridge 12 filtering 729/2000ml at 0.29ml/s with 25.3psi vacuum 16.6m deep (39.2psia) @07:04:12.06 Cartridge 12 filtering 747/2000ml at 0.30ml/s with 15.1psi vacuum 22.8m deep (48.4psia) @07:05:12.06 Cartridge 12 filtering 765/2000ml at 0.28ml/s with 24.4psi vacuum 17.3m deep (40.2psia) @07:06:12.06 Cartridge 12 filtering 782/2000ml at 0.30ml/s with 26.9psi vacuum 17.3m deep (40.2psia) @07:07:12.06 Cartridge 12 filtering 799/2000ml at 0.31ml/s with 24.7psi vacuum 18.0m deep (41.2psia) @07:08:12.06 Cartridge 12 filtering 815/2000ml at 0.29ml/s with 24.9psi vacuum 18.3m deep (41.8psia) @07:09:12.07 Cartridge 12 filtering 832/2000ml at 0.26ml/s with 24.0psi vacuum 17.3m deep (40.3psia) @07:10:12.06 Cartridge 12 filtering 848/2000ml at 0.29ml/s with 25.8psi vacuum 16.3m deep (38.8psia) @07:11:12.06 Cartridge 12 filtering 864/2000ml at 0.26ml/s with 21.5psi vacuum 13.8m deep (35.2psia) @07:12:12.06 Cartridge 12 filtering 880/2000ml at 0.27ml/s with 25.1psi vacuum 17.9m deep (41.2psia) @07:13:12.06 Cartridge 12 filtering 896/2000ml at 0.26ml/s with 25.5psi vacuum 17.6m deep (40.7psia) @07:14:12.06 Cartridge 12 filtering 911/2000ml at 0.24ml/s with 24.1psi vacuum 17.4m deep (40.4psia) @07:15:12.06 Cartridge 12 filtering 926/2000ml at 0.25ml/s with 21.0psi vacuum 17.8m deep (41.0psia) @07:16:12.06 Cartridge 12 filtering 941/2000ml at 0.27ml/s with 24.9psi vacuum 18.1m deep (41.4psia) @07:17:12.07 Cartridge 12 filtering 956/2000ml at 0.27ml/s with 18.0psi vacuum 21.3m deep (46.2psia) @07:18:12.06 Cartridge 12 filtering 971/2000ml at 0.26ml/s with 25.3psi vacuum 18.6m deep (42.2psia) @07:19:12.06 Cartridge 12 filtering 985/2000ml at 0.24ml/s with 26.8psi vacuum 15.4m deep (37.5psia) @07:20:12.06 Cartridge 12 filtering 1000/2000ml at 0.23ml/s with 27.9psi vacuum 15.4m deep (37.5psia) @07:21:12.06 Cartridge 12 filtering 1014/2000ml at 0.25ml/s with 26.8psi vacuum 17.3m deep (40.3psia) @07:22:12.06 Cartridge 12 filtering 1028/2000ml at 0.24ml/s with 18.4psi vacuum 21.3m deep (46.1psia) @07:23:12.06 Cartridge 12 filtering 1041/2000ml at 0.22ml/s with 23.3psi vacuum 12.8m deep (33.6psia) @07:24:12.06 Cartridge 12 filtering 1055/2000ml at 0.25ml/s with 18.3psi vacuum 21.7m deep (46.8psia) @07:25:12.40 Cartridge 12 filtering 1069/2000ml at 0.23ml/s with 22.3psi vacuum 19.0m deep (42.7psia) @07:26:12.06 Cartridge 12 filtering 1082/2000ml at 0.21ml/s with 26.0psi vacuum 16.1m deep (38.4psia) @07:27:12.06 Cartridge 12 filtering 1095/2000ml at 0.21ml/s with 22.6psi vacuum 15.5m deep (37.6psia) @07:28:12.07 Cartridge 12 filtering 1108/2000ml at 0.22ml/s with 26.4psi vacuum 16.9m deep (39.6psia) @07:29:12.06 Cartridge 12 filtering 1121/2000ml at 0.20ml/s with 23.2psi vacuum 17.4m deep (40.4psia) @07:30:12.06 Cartridge 12 filtering 1134/2000ml at 0.22ml/s with 25.0psi vacuum 18.0m deep (41.2psia) @07:31:12.06 Cartridge 12 filtering 1146/2000ml at 0.21ml/s with 26.0psi vacuum 16.9m deep (39.7psia) @07:32:12.06 Cartridge 12 filtering 1159/2000ml at 0.22ml/s with 16.0psi vacuum 22.0m deep (47.2psia) @07:33:12.06 Cartridge 12 filtering 1172/2000ml at 0.20ml/s with 25.1psi vacuum 16.5m deep (39.1psia) @07:34:12.06 Cartridge 12 filtering 1184/2000ml at 0.20ml/s with 25.1psi vacuum 17.3m deep (40.2psia) @07:35:12.06 Cartridge 12 filtering 1196/2000ml at 0.21ml/s with 16.1psi vacuum 20.3m deep (44.7psia) @07:36:12.06 Cartridge 12 filtering 1209/2000ml at 0.20ml/s with 24.2psi vacuum 13.0m deep (33.9psia) @07:37:12.06 Cartridge 12 filtering 1221/2000ml at 0.20ml/s with 26.1psi vacuum 17.0m deep (39.8psia) @07:37:50.60 Flow averaged 0.32ml/s over 1:04:42 @07:37:50.64 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @07:37:51.24 Relieved excess vacuum in .6 seconds @07:37:51.27 SamplePump.seek 2000ml,1:04:43 @07:38:12.06 Cartridge 12 filtering 1233/2000ml at 0.21ml/s with 27.4psi vacuum 15.7m deep (38.0psia) @07:39:12.06 Cartridge 12 filtering 1246/2000ml at 0.20ml/s with 23.3psi vacuum 12.3m deep (32.8psia) @07:40:12.06 Cartridge 12 filtering 1258/2000ml at 0.20ml/s with 26.1psi vacuum 16.5m deep (39.0psia) @07:40:33.26 Flow averaged 0.20ml/s over 2:42 @07:40:33.30 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @07:40:33.93 Relieved excess vacuum in .7 seconds @07:40:33.96 SamplePump.seek 2000ml,1:01:57 @07:41:12.06 Cartridge 12 filtering 1270/2000ml at 0.21ml/s with 16.1psi vacuum 21.6m deep (46.7psia) @07:42:12.06 Cartridge 12 filtering 1282/2000ml at 0.20ml/s with 25.7psi vacuum 16.1m deep (38.5psia) @07:42:12.98 Flow averaged 0.21ml/s over 1:40 @07:42:13.02 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @07:42:13.62 Relieved excess vacuum in .7 seconds @07:42:13.65 SamplePump.seek 2000ml,1:00:16 @07:43:12.05 Cartridge 12 filtering 1295/2000ml at 0.20ml/s with 25.0psi vacuum 17.5m deep (40.5psia) @07:43:26.12 Flow averaged 0.20ml/s over 1:13 @07:43:26.16 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @07:43:26.74 Relieved excess vacuum in .6 seconds @07:43:26.77 SamplePump.seek 2000ml,59:02 @07:44:12.06 Cartridge 12 filtering 1307/2000ml at 0.20ml/s with 26.9psi vacuum 16.1m deep (38.5psia) @07:44:18.66 Flow averaged 0.20ml/s over 52 seconds @07:44:18.70 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @07:44:19.29 Relieved excess vacuum in .6 seconds @07:44:19.32 SamplePump.seek 2000ml,58:09 @07:45:12.06 Cartridge 12 filtering 1319/2000ml at 0.20ml/s with 26.4psi vacuum 17.3m deep (40.2psia) @07:45:27.34 Flow averaged 0.20ml/s over 1:09 @07:45:27.77 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @07:45:28.36 Relieved excess vacuum in 1 second @07:45:28.39 SamplePump.seek 2000ml,56:59 @07:46:12.05 Cartridge 12 filtering 1331/2000ml at 0.20ml/s with 23.0psi vacuum 17.8m deep (41.0psia) @07:46:16.43 Flow averaged 0.20ml/s over 49 seconds @07:46:16.47 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @07:46:17.07 Relieved excess vacuum in .6 seconds @07:46:17.10 SamplePump.seek 2000ml,56:10 @07:46:56.56 Flow averaged 0.20ml/s over 40 seconds @07:46:56.60 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @07:46:57.19 Relieved excess vacuum in .6 seconds @07:46:57.21 SamplePump.seek 2000ml,55:30 @07:47:12.05 Cartridge 12 filtering 1343/2000ml at 0.20ml/s with 25.0psi vacuum 17.6m deep (40.8psia) @07:47:26.70 Flow averaged 0.20ml/s over 30 seconds @07:47:26.74 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @07:47:27.33 Relieved excess vacuum in .6 seconds @07:47:27.36 SamplePump.seek 2000ml,55:00 @07:48:11.12 Flow averaged 0.20ml/s over 44 seconds @07:48:11.16 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @07:48:11.74 Relieved excess vacuum in .6 seconds @07:48:11.77 SamplePump.seek 2000ml,54:15 @07:48:12.05 Cartridge 12 filtering 1355/2000ml at 0.06ml/s with 0.4psi vacuum 19.9m deep (44.1psia) @07:48:38.85 Flow averaged 0.20ml/s over 28 seconds @07:48:38.89 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @07:48:39.48 Relieved excess vacuum in .6 seconds @07:48:39.50 SamplePump.seek 2000ml,53:48 @07:49:11.45 Flow averaged 0.20ml/s over 32 seconds @07:49:11.50 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @07:49:12.05 Cartridge 12 filtering 1367/2000ml at 0.00ml/s with 0.2psi vacuum 16.4m deep (39.0psia) @07:49:12.19 Relieved excess vacuum in .7 seconds @07:49:12.22 SamplePump.seek 2000ml,53:15 @07:49:32.20 Flow averaged 0.20ml/s over 20 seconds @07:49:32.24 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @07:49:32.83 Relieved excess vacuum in .6 seconds @07:49:32.86 SamplePump.seek 2000ml,52:55 @07:49:45.50 Flow averaged 0.20ml/s over 13 seconds @07:49:45.54 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @07:49:46.13 Relieved excess vacuum in .6 seconds @07:49:46.16 SamplePump.seek 2000ml,52:43 @07:50:08.77 Flow averaged 0.20ml/s over 23 seconds @07:50:08.81 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @07:50:09.40 Relieved excess vacuum in .6 seconds @07:50:09.43 SamplePump.seek 2000ml,52:20 @07:50:12.05 Cartridge 12 filtering 1378/2000ml at 0.20ml/s with 27.4psi vacuum 15.3m deep (37.3psia) @07:50:43.19 Flow averaged 0.20ml/s over 34 seconds @07:50:43.24 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @07:50:43.83 Relieved excess vacuum in .7 seconds @07:50:43.86 SamplePump.seek 2000ml,51:45 @07:50:53.41 Flow averaged 0.20ml/s over 10 seconds @07:50:53.44 Intake.close @07:50:53.52 Exhaust.close @07:50:53.74 Toroid.in :hold @07:50:53.82 Toroid.seek :bypass @07:50:55.47 Toroid.in :default @07:50:55.55 Toroid.seek :clear @07:50:57.17 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @07:50:57.19 Pressure.stop @07:50:57.39 Sampled 1386.6ml @07:50:59.44 -> Cmd.startProcessing @07:50:59.88 Plunge.seek :reagent @07:51:00.83 Sample loop closed. Ready to Deliver Reagents @07:51:00.86 Archive.seek :sealed @07:51:04.51 Archive.seek :evac @07:51:18.52 delay 1:00 @07:52:18.55 Archive.seek :clear @07:52:35.72 Sample preserved. Puck Full. @07:52:36.81 -> Cmd.stop @07:52:36.90 Carousel.in :default @07:52:37.03 Carousel.home.seek 12 @07:52:37.35 Plunge.seek :locked @07:52:38.38 Air.in :unlocking @07:52:38.53 Lysis1.in :unlocking @07:52:38.57 Air.seek :clear @07:52:38.74 Lysis1.seek :clear @07:52:40.03 Gate.power :motor,:OFF @07:52:40.04 Gate.power :core,:OFF @07:52:40.07 Gate.power :analytic1,:OFF @07:52:40.09 Gate.power :analytic2,:OFF @07:52:40.12 Gate.power :analytic3,:OFF @07:52:40.15 Gate.power :main,:OFF @07:52:40.17 Safely stopped and ready to power off ##-- file closed 2023-08-13T08:00:52.438Z ##-- file opened 2023-08-13T08:00:52.440Z @08:00:53.03 -> showStatus @08:00:55.04 -> Cmd.loadCartridge -1 @08:00:55.10 Gate.power :main,:ON,limit to 5000mA @08:00:55.12 Gate.power :analytic1,:ON,limit to 5000mA @08:00:55.15 Gate.power :analytic2,:ON,limit to 5000mA @08:00:55.22 Gate.power :analytic3,:ON,limit to 5000mA @08:00:55.27 Powering core bus @08:00:58.33 Archive.configure :default @08:00:58.42 Air.configure :default @08:00:58.49 Lysis1.configure :default @08:00:58.56 Lysis2.configure :default @08:00:58.65 Plunge.configure :default @08:00:58.75 SamplePump.configure :default @08:00:58.84 Toroid.configure :default @08:00:58.93 Carousel.configure :default @08:00:59.02 Pressure.configure :default @08:00:59.12 ExtraPump.configure :default @08:00:59.19 All elf controllers running firmware version 4.83 @08:00:59.21 Gate.power :motor,:ON,limit to 5000mA @08:00:59.40 Archive.home.jog 0 @08:00:59.88 Toroid.home.jog 0 @08:00:59.91 Plunge.home.jog 0 @08:00:59.93 Lysis2.home.jog 0 @08:00:59.96 Lysis1.home.jog 0 @08:01:00.00 Air.home.jog 0 @08:01:00.04 Carousel.home.jog 0 @08:01:00.57 Archive.in :homing @08:01:00.80 Archive.jog 1359 @08:01:00.85 Plunge.in :homing @08:01:00.88 Lysis2.in :homing @08:01:00.93 Lysis1.in :homing @08:01:00.96 Air.in :homing @08:01:01.00 Toroid.in :homing @08:01:01.20 Plunge.jog 769 @08:01:01.26 Lysis2.jog 1365 @08:01:01.29 Lysis1.jog 1361 @08:01:01.32 Toroid.jog 601 @08:01:01.35 Air.jog 165 @08:01:01.94 Air.setRawPosition! 50 @08:01:01.99 Air.seek :home @08:01:02.18 Archive.setRawPosition! 50 @08:01:02.24 Archive.seek :home @08:01:02.34 Plunge.setRawPosition! 50 @08:01:02.36 Air.in :default @08:01:02.46 Plunge.seek :home @08:01:02.57 Lysis1.setRawPosition! 50 @08:01:02.60 Archive.in :default @08:01:02.68 Lysis1.seek :home @08:01:02.79 Plunge.in :default @08:01:02.82 Lysis2.setRawPosition! 50 @08:01:02.94 Lysis2.seek :home @08:01:03.03 Lysis1.in :default @08:01:03.22 Lysis2.in :default @08:01:03.52 Toroid.setRawPosition! 0 @08:01:03.58 Toroid.seek :home @08:01:03.66 Toroid.in :default @08:01:03.74 Toroid.seek :clear @08:01:05.36 Carousel.in :default @08:01:05.48 Carousel.home.seek 12 @08:01:05.79 Selecting Cartridge 11 @08:01:06.01 Carousel.seek 11 @08:01:06.51 Lysis1.in :fast @08:01:06.57 Lysis1.seek :locked @08:01:08.81 Plunge.seek :locked @08:01:09.32 Air.in :fast @08:01:09.39 Air.seek :locked @08:01:10.94 Carousel.reconfigure :locked @08:01:11.61 Mounted archive Cartridge @08:01:26.95 -> Cmd.startFiltering @08:01:27.21 Preparing to filter cartridge 11 @08:01:27.50 Priming sample loop w/100ml, bypass w/10ml @08:01:27.52 SamplePump.setPosition! 0ml @08:01:27.57 Bypass.open @08:01:29.03 Intake.open @08:01:29.80 Sea 16.4m deep (38.9psia) @08:01:29.82 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @08:01:32.40 Vacuum tare is 51% of full scale @08:01:32.54 Intake.close @08:01:32.60 Bypass.close @08:01:33.30 Verifying toroid holds at least 0.6..0.85 of 38.9psia @08:01:33.33 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @08:01:37.91 Bypass.open @08:01:38.59 Intake.open @08:01:40.06 Pressure.in :default @08:01:40.12 Pressure.hold @08:01:40.33 SamplePump.in :prime @08:01:40.40 SamplePump.seek 10ml,59 seconds @08:01:51.25 Pressure.stop @08:01:51.30 SamplePump.setPosition! 0ml @08:01:51.36 Exhaust.open @08:01:52.77 Bypass.close @08:01:54.27 Pressure.in :default @08:01:54.33 Pressure.hold @08:01:54.46 Sea 16.2m deep (38.7psia) @08:01:54.60 SamplePump.in :prime @08:01:54.68 SamplePump.seek 100ml,5:16 @08:03:42.32 Pressure.stop @08:03:42.40 Bypass.open @08:03:43.11 Intake.close @08:03:44.22 Toroid.in :hold @08:03:44.29 Toroid.seek :crack @08:03:46.02 Toroid.seek :cartridge @08:03:47.00 Toroid.in :default @08:03:47.06 Toroid.seek :clear @08:03:49.10 Exhaust.close @08:03:49.15 Bypass.close @08:03:49.86 Verifying cartridge holds at least 0.65..0.85 of 38.7psia @08:03:49.88 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @08:03:54.51 Sampling 2000.0ml @08:03:54.52 SamplePump.setPosition! 0ml @08:03:54.58 Exhaust.open @08:03:55.27 Intake.open @08:03:56.13 Pressure.in :default @08:03:56.19 Pressure.hold @08:03:56.32 Sea 16.4m deep (38.9psia) @08:03:56.34 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @08:03:56.50 SamplePump.in :sample @08:03:56.57 SamplePump.seek 2000ml,2:47:06 @08:03:59.17 Cartridge 11 filtering 1/2000ml at 0.54ml/s with 24.6psi vacuum 16.6m deep (39.2psia) @08:04:59.17 Cartridge 11 filtering 32/2000ml at 0.52ml/s with 24.2psi vacuum 16.6m deep (39.3psia) @08:05:59.16 Cartridge 11 filtering 63/2000ml at 0.51ml/s with 25.0psi vacuum 16.7m deep (39.4psia) @08:06:59.18 Cartridge 11 filtering 94/2000ml at 0.51ml/s with 21.7psi vacuum 19.8m deep (44.0psia) @08:07:59.16 Cartridge 11 filtering 124/2000ml at 0.50ml/s with 23.1psi vacuum 19.0m deep (42.7psia) @08:08:59.18 Cartridge 11 filtering 152/2000ml at 0.48ml/s with 26.4psi vacuum 16.3m deep (38.7psia) @08:09:59.17 Cartridge 11 filtering 180/2000ml at 0.48ml/s with 20.9psi vacuum 18.5m deep (42.0psia) @08:10:59.18 Cartridge 11 filtering 208/2000ml at 0.46ml/s with 27.3psi vacuum 12.5m deep (33.1psia) @08:11:59.18 Cartridge 11 filtering 234/2000ml at 0.46ml/s with 25.8psi vacuum 16.2m deep (38.7psia) @08:12:59.17 Cartridge 11 filtering 260/2000ml at 0.44ml/s with 24.4psi vacuum 18.1m deep (41.4psia) @08:13:59.17 Cartridge 11 filtering 286/2000ml at 0.43ml/s with 22.8psi vacuum 18.3m deep (41.7psia) @08:14:59.17 Cartridge 11 filtering 310/2000ml at 0.41ml/s with 26.8psi vacuum 11.9m deep (32.3psia) @08:15:59.17 Cartridge 11 filtering 335/2000ml at 0.39ml/s with 26.0psi vacuum 15.7m deep (37.9psia) @08:16:59.17 Cartridge 11 filtering 358/2000ml at 0.41ml/s with 24.0psi vacuum 17.9m deep (41.1psia) @08:17:59.17 Cartridge 11 filtering 381/2000ml at 0.40ml/s with 22.0psi vacuum 18.1m deep (41.4psia) @08:18:59.17 Cartridge 11 filtering 404/2000ml at 0.37ml/s with 27.6psi vacuum 14.9m deep (36.8psia) @08:19:59.55 Cartridge 11 filtering 426/2000ml at 0.38ml/s with 23.6psi vacuum 19.5m deep (43.5psia) @08:20:59.17 Cartridge 11 filtering 448/2000ml at 0.35ml/s with 23.9psi vacuum 17.2m deep (40.1psia) @08:21:59.17 Cartridge 11 filtering 470/2000ml at 0.35ml/s with 16.1psi vacuum 20.3m deep (44.7psia) @08:22:59.17 Cartridge 11 filtering 491/2000ml at 0.34ml/s with 21.0psi vacuum 14.9m deep (36.7psia) @08:23:59.17 Cartridge 11 filtering 511/2000ml at 0.34ml/s with 23.1psi vacuum 19.1m deep (42.9psia) @08:24:59.16 Cartridge 11 filtering 531/2000ml at 0.34ml/s with 17.4psi vacuum 21.4m deep (46.3psia) @08:25:59.17 Cartridge 11 filtering 551/2000ml at 0.34ml/s with 25.8psi vacuum 17.8m deep (41.0psia) @08:26:59.17 Cartridge 11 filtering 571/2000ml at 0.35ml/s with 25.6psi vacuum 18.6m deep (42.2psia) @08:27:59.17 Cartridge 11 filtering 590/2000ml at 0.34ml/s with 24.5psi vacuum 16.6m deep (39.2psia) @08:28:59.17 Cartridge 11 filtering 609/2000ml at 0.30ml/s with 24.8psi vacuum 16.8m deep (39.5psia) @08:29:59.18 Cartridge 11 filtering 627/2000ml at 0.31ml/s with 25.6psi vacuum 17.5m deep (40.6psia) @08:30:59.17 Cartridge 11 filtering 645/2000ml at 0.29ml/s with 22.9psi vacuum 14.7m deep (36.5psia) @08:31:59.17 Cartridge 11 filtering 663/2000ml at 0.29ml/s with 25.1psi vacuum 14.8m deep (36.6psia) @08:32:59.17 Cartridge 11 filtering 681/2000ml at 0.29ml/s with 26.5psi vacuum 16.6m deep (39.2psia) @08:33:59.17 Cartridge 11 filtering 698/2000ml at 0.28ml/s with 23.9psi vacuum 11.4m deep (31.6psia) @08:34:59.17 Cartridge 11 filtering 716/2000ml at 0.28ml/s with 26.3psi vacuum 15.6m deep (37.7psia) @08:35:59.17 Cartridge 11 filtering 733/2000ml at 0.31ml/s with 25.9psi vacuum 16.6m deep (39.2psia) @08:36:59.17 Cartridge 11 filtering 749/2000ml at 0.28ml/s with 17.0psi vacuum 20.7m deep (45.2psia) @08:37:59.17 Cartridge 11 filtering 766/2000ml at 0.29ml/s with 25.4psi vacuum 16.2m deep (38.6psia) @08:38:59.17 Cartridge 11 filtering 782/2000ml at 0.27ml/s with 25.1psi vacuum 17.2m deep (40.1psia) @08:39:59.17 Cartridge 11 filtering 798/2000ml at 0.28ml/s with 26.1psi vacuum 16.1m deep (38.5psia) @08:40:59.17 Cartridge 11 filtering 814/2000ml at 0.28ml/s with 18.1psi vacuum 21.7m deep (46.8psia) @08:41:59.17 Cartridge 11 filtering 829/2000ml at 0.25ml/s with 25.5psi vacuum 13.0m deep (33.9psia) @08:42:59.17 Cartridge 11 filtering 844/2000ml at 0.24ml/s with 24.5psi vacuum 16.5m deep (39.1psia) @08:43:59.17 Cartridge 11 filtering 860/2000ml at 0.24ml/s with 22.5psi vacuum 12.3m deep (32.8psia) @08:44:59.17 Cartridge 11 filtering 875/2000ml at 0.24ml/s with 26.0psi vacuum 15.5m deep (37.7psia) @08:45:59.17 Cartridge 11 filtering 889/2000ml at 0.26ml/s with 26.6psi vacuum 17.4m deep (40.4psia) @08:46:59.17 Cartridge 11 filtering 904/2000ml at 0.23ml/s with 23.6psi vacuum 17.0m deep (39.8psia) @08:47:59.22 Cartridge 11 filtering 919/2000ml at 0.23ml/s with 25.8psi vacuum 15.7m deep (38.0psia) @08:48:59.17 Cartridge 11 filtering 933/2000ml at 0.26ml/s with 25.1psi vacuum 17.5m deep (40.5psia) @08:49:59.17 Cartridge 11 filtering 947/2000ml at 0.22ml/s with 24.2psi vacuum 15.5m deep (37.6psia) @08:50:59.17 Cartridge 11 filtering 961/2000ml at 0.25ml/s with 24.9psi vacuum 17.5m deep (40.5psia) @08:51:59.17 Cartridge 11 filtering 975/2000ml at 0.25ml/s with 18.4psi vacuum 21.1m deep (45.8psia) @08:52:59.17 Cartridge 11 filtering 989/2000ml at 0.25ml/s with 23.3psi vacuum 19.5m deep (43.5psia) @08:53:59.17 Cartridge 11 filtering 1002/2000ml at 0.25ml/s with 26.0psi vacuum 17.2m deep (40.1psia) @08:54:59.17 Cartridge 11 filtering 1016/2000ml at 0.24ml/s with 25.3psi vacuum 16.9m deep (39.6psia) @08:55:59.55 Cartridge 11 filtering 1029/2000ml at 0.22ml/s with 17.2psi vacuum 20.2m deep (44.5psia) @08:56:59.18 Cartridge 11 filtering 1042/2000ml at 0.20ml/s with 24.6psi vacuum 16.7m deep (39.4psia) @08:57:59.17 Cartridge 11 filtering 1055/2000ml at 0.20ml/s with 25.7psi vacuum 16.2m deep (38.6psia) @08:58:59.16 Cartridge 11 filtering 1068/2000ml at 0.23ml/s with 26.1psi vacuum 16.2m deep (38.7psia) @08:59:59.17 Cartridge 11 filtering 1081/2000ml at 0.21ml/s with 26.7psi vacuum 16.2m deep (38.7psia) @09:00:59.17 Cartridge 11 filtering 1093/2000ml at 0.21ml/s with 21.0psi vacuum 19.5m deep (43.4psia) @09:01:59.17 Cartridge 11 filtering 1106/2000ml at 0.20ml/s with 25.2psi vacuum 16.3m deep (38.8psia) @09:02:59.17 Cartridge 11 filtering 1119/2000ml at 0.20ml/s with 24.4psi vacuum 11.8m deep (32.2psia) @09:03:59.17 Cartridge 11 filtering 1131/2000ml at 0.20ml/s with 25.0psi vacuum 17.3m deep (40.2psia) @09:04:59.17 Cartridge 11 filtering 1144/2000ml at 0.20ml/s with 25.7psi vacuum 16.6m deep (39.3psia) @09:05:59.18 Cartridge 11 filtering 1156/2000ml at 0.20ml/s with 26.8psi vacuum 16.6m deep (39.2psia) @09:06:59.17 Cartridge 11 filtering 1168/2000ml at 0.20ml/s with 27.0psi vacuum 17.5m deep (40.5psia) @09:07:03.92 Flow averaged 0.31ml/s over 1:03:08 @09:07:03.96 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @09:07:04.55 Relieved excess vacuum in .6 seconds @09:07:04.58 SamplePump.seek 2000ml,1:09:41 @09:07:59.16 Cartridge 11 filtering 1181/2000ml at 0.20ml/s with 25.5psi vacuum 17.2m deep (40.0psia) @09:08:59.16 Cartridge 11 filtering 1193/2000ml at 0.20ml/s with 26.2psi vacuum 15.9m deep (38.1psia) @09:09:06.06 Flow averaged 0.21ml/s over 2:02 @09:09:06.10 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @09:09:06.69 Relieved excess vacuum in .6 seconds @09:09:06.72 SamplePump.seek 2000ml,1:07:36 @09:09:59.16 Cartridge 11 filtering 1205/2000ml at 0.20ml/s with 27.4psi vacuum 16.9m deep (39.7psia) @09:10:41.35 Flow averaged 0.21ml/s over 1:35 @09:10:41.40 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @09:10:41.98 Relieved excess vacuum in .6 seconds @09:10:42.01 SamplePump.seek 2000ml,1:05:59 @09:10:59.16 Cartridge 11 filtering 1217/2000ml at 0.22ml/s with 27.7psi vacuum 16.0m deep (38.3psia) @09:11:55.82 Flow averaged 0.21ml/s over 1:14 @09:11:55.86 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @09:11:56.45 Relieved excess vacuum in .6 seconds @09:11:56.48 SamplePump.seek 2000ml,1:04:43 @09:11:59.16 Cartridge 11 filtering 1230/2000ml at 0.20ml/s with 29.3psi vacuum 15.2m deep (37.1psia) @09:12:40.37 Flow averaged 0.20ml/s over 44 seconds @09:12:40.40 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @09:12:40.99 Relieved excess vacuum in .6 seconds @09:12:41.02 SamplePump.seek 2000ml,1:03:58 @09:12:59.16 Cartridge 11 filtering 1242/2000ml at 0.20ml/s with 27.2psi vacuum 15.6m deep (37.8psia) @09:13:37.85 Flow averaged 0.20ml/s over 57 seconds @09:13:37.89 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @09:13:38.48 Relieved excess vacuum in .6 seconds @09:13:38.51 SamplePump.seek 2000ml,1:03:00 @09:13:59.17 Cartridge 11 filtering 1254/2000ml at 0.21ml/s with 26.9psi vacuum 15.4m deep (37.5psia) @09:14:22.81 Flow averaged 0.20ml/s over 45 seconds @09:14:22.86 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @09:14:23.44 Relieved excess vacuum in .6 seconds @09:14:23.47 SamplePump.seek 2000ml,1:02:14 @09:14:59.16 Cartridge 11 filtering 1266/2000ml at 0.20ml/s with 29.1psi vacuum 16.4m deep (38.9psia) @09:15:09.81 Flow averaged 0.20ml/s over 47 seconds @09:15:09.84 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @09:15:10.44 Relieved excess vacuum in .6 seconds @09:15:10.47 SamplePump.seek 2000ml,1:01:27 @09:15:27.38 Flow averaged 0.20ml/s over 17 seconds @09:15:27.42 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @09:15:28.01 Relieved excess vacuum in .6 seconds @09:15:28.04 SamplePump.seek 2000ml,1:01:10 @09:15:59.16 Cartridge 11 filtering 1278/2000ml at 0.22ml/s with 27.7psi vacuum 16.8m deep (39.5psia) @09:16:07.89 Flow averaged 0.20ml/s over 40 seconds @09:16:07.94 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @09:16:08.52 Relieved excess vacuum in .6 seconds @09:16:08.55 SamplePump.seek 2000ml,1:00:29 @09:16:27.81 Flow averaged 0.20ml/s over 20 seconds @09:16:27.86 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @09:16:28.44 Relieved excess vacuum in .6 seconds @09:16:28.47 SamplePump.seek 2000ml,1:00:10 @09:16:39.38 Flow averaged 0.20ml/s over 11 seconds @09:16:39.42 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @09:16:40.02 Relieved excess vacuum in .6 seconds @09:16:40.05 SamplePump.seek 2000ml,59:59 @09:16:47.84 Flow estimate reduced to 0.16ml/s @09:16:47.86 Intake.close @09:16:47.90 Exhaust.close @09:16:48.15 Toroid.in :hold @09:16:48.23 Toroid.seek :bypass @09:16:49.88 Toroid.in :default @09:16:49.95 Toroid.seek :clear @09:16:51.57 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @09:16:51.59 Pressure.stop @09:16:51.80 Sampled 1287.5ml @09:16:53.92 -> Cmd.startProcessing @09:16:54.35 Plunge.seek :reagent @09:16:55.25 Sample loop closed. Ready to Deliver Reagents @09:16:55.27 Archive.seek :sealed @09:16:58.93 Archive.seek :evac @09:17:12.94 delay 1:00 @09:18:12.97 Archive.seek :clear @09:18:30.14 Sample preserved. Puck Full. @09:18:31.29 -> Cmd.stop @09:18:31.75 Carousel.in :default @09:18:31.87 Carousel.home.seek 11 @09:18:32.18 Plunge.seek :locked @09:18:33.21 Air.in :unlocking @09:18:33.33 Air.seek :clear @09:18:33.38 Lysis1.in :unlocking @09:18:33.55 Lysis1.seek :clear @09:18:34.82 Gate.power :motor,:OFF @09:18:34.84 Gate.power :core,:OFF @09:18:34.87 Gate.power :analytic1,:OFF @09:18:34.89 Gate.power :analytic2,:OFF @09:18:34.91 Gate.power :analytic3,:OFF @09:18:34.94 Gate.power :main,:OFF @09:18:34.96 Safely stopped and ready to power off ##-- file closed 2023-08-13T09:43:50.046Z ##-- file opened 2023-08-13T09:43:50.048Z @09:43:50.60 -> showStatus @09:43:52.62 -> Cmd.loadCartridge -1 @09:43:52.69 Gate.power :main,:ON,limit to 5000mA @09:43:52.71 Gate.power :analytic1,:ON,limit to 5000mA @09:43:52.74 Gate.power :analytic2,:ON,limit to 5000mA @09:43:52.76 Gate.power :analytic3,:ON,limit to 5000mA @09:43:52.81 Powering core bus @09:43:55.86 Archive.configure :default @09:43:55.96 Air.configure :default @09:43:56.02 Lysis1.configure :default @09:43:56.09 Lysis2.configure :default @09:43:56.19 Plunge.configure :default @09:43:56.28 SamplePump.configure :default @09:43:56.37 Toroid.configure :default @09:43:56.47 Carousel.configure :default @09:43:56.56 Pressure.configure :default @09:43:56.65 ExtraPump.configure :default @09:43:56.72 All elf controllers running firmware version 4.83 @09:43:56.75 Gate.power :motor,:ON,limit to 5000mA @09:43:56.96 Archive.home.jog 0 @09:43:57.40 Toroid.home.jog 0 @09:43:57.44 Plunge.home.jog 0 @09:43:57.47 Air.home.jog 0 @09:43:57.53 Lysis1.home.jog 0 @09:43:57.56 Carousel.home.jog 0 @09:43:57.58 Lysis2.home.jog 0 @09:43:58.07 Archive.in :homing @09:43:58.35 Archive.jog 1360 @09:43:58.39 Toroid.in :homing @09:43:58.41 Plunge.in :homing @09:43:58.46 Lysis2.in :homing @09:43:58.49 Air.in :homing @09:43:58.53 Lysis1.in :homing @09:43:58.72 Toroid.jog 599 @09:43:58.79 Plunge.jog 772 @09:43:58.82 Lysis2.jog 1365 @09:43:58.87 Lysis1.jog 1363 @09:43:58.91 Air.jog 163 @09:43:59.47 Air.setRawPosition! 50 @09:43:59.53 Air.seek :home @09:43:59.70 Archive.setRawPosition! 50 @09:43:59.75 Archive.seek :home @09:43:59.84 Plunge.setRawPosition! 50 @09:43:59.87 Air.in :default @09:43:59.96 Plunge.seek :home @09:44:00.07 Archive.in :default @09:44:00.16 Lysis2.setRawPosition! 50 @09:44:00.19 Lysis1.setRawPosition! 50 @09:44:00.28 Lysis2.seek :home @09:44:00.32 Lysis1.seek :home @09:44:00.44 Plunge.in :default @09:44:00.61 Lysis2.in :default @09:44:00.69 Lysis1.in :default @09:44:00.89 Toroid.setRawPosition! 0 @09:44:00.95 Toroid.seek :home @09:44:01.03 Toroid.in :default @09:44:01.11 Toroid.seek :clear @09:44:02.73 Carousel.in :default @09:44:02.86 Carousel.home.seek 11 @09:44:03.12 Selecting Cartridge 10 @09:44:03.34 Carousel.seek 10 @09:44:03.83 Lysis1.in :fast @09:44:03.90 Lysis1.seek :locked @09:44:06.14 Plunge.seek :locked @09:44:06.65 Air.in :fast @09:44:06.73 Air.seek :locked @09:44:08.27 Carousel.reconfigure :locked @09:44:08.92 Mounted archive Cartridge @09:44:24.54 -> Cmd.startFiltering @09:44:24.80 Preparing to filter cartridge 10 @09:44:25.15 Priming sample loop w/100ml, bypass w/10ml @09:44:25.17 SamplePump.setPosition! 0ml @09:44:25.22 Bypass.open @09:44:26.68 Intake.open @09:44:27.42 Sea 16.9m deep (39.7psia) @09:44:27.44 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @09:44:30.03 Vacuum tare is 50% of full scale @09:44:30.22 Intake.close @09:44:30.28 Bypass.close @09:44:30.96 Verifying toroid holds at least 0.6..0.85 of 39.8psia @09:44:30.98 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @09:44:35.61 Bypass.open @09:44:36.27 Intake.open @09:44:37.72 Pressure.in :default @09:44:37.79 Pressure.hold @09:44:37.99 SamplePump.in :prime @09:44:38.06 SamplePump.seek 10ml,59 seconds @09:44:48.92 Pressure.stop @09:44:48.97 SamplePump.setPosition! 0ml @09:44:49.04 Exhaust.open @09:44:50.46 Bypass.close @09:44:51.92 Pressure.in :default @09:44:51.98 Pressure.hold @09:44:52.11 Sea 16.6m deep (39.3psia) @09:44:52.27 SamplePump.in :prime @09:44:52.34 SamplePump.seek 100ml,5:16 @09:46:39.30 Pressure.stop @09:46:39.38 Bypass.open @09:46:40.08 Intake.close @09:46:41.17 Toroid.in :hold @09:46:41.24 Toroid.seek :crack @09:46:42.98 Toroid.seek :cartridge @09:46:43.96 Toroid.in :default @09:46:44.02 Toroid.seek :clear @09:46:46.07 Exhaust.close @09:46:46.12 Bypass.close @09:46:46.85 Verifying cartridge holds at least 0.65..0.85 of 39.1psia @09:46:46.87 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @09:46:51.50 Sampling 2000.0ml @09:46:51.52 SamplePump.setPosition! 0ml @09:46:51.59 Exhaust.open @09:46:52.28 Intake.open @09:46:53.12 Pressure.in :default @09:46:53.18 Pressure.hold @09:46:53.31 Sea 16.6m deep (39.2psia) @09:46:53.32 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @09:46:53.48 SamplePump.in :sample @09:46:53.56 SamplePump.seek 2000ml,2:47:06 @09:46:56.20 Cartridge 10 filtering 1/2000ml at 0.59ml/s with 24.8psi vacuum 16.0m deep (38.4psia) @09:47:56.16 Cartridge 10 filtering 34/2000ml at 0.54ml/s with 26.1psi vacuum 16.7m deep (39.4psia) @09:48:56.16 Cartridge 10 filtering 66/2000ml at 0.55ml/s with 21.2psi vacuum 19.3m deep (43.2psia) @09:49:56.16 Cartridge 10 filtering 98/2000ml at 0.51ml/s with 26.2psi vacuum 16.9m deep (39.7psia) @09:50:56.16 Cartridge 10 filtering 128/2000ml at 0.51ml/s with 24.9psi vacuum 15.7m deep (38.0psia) @09:51:56.16 Cartridge 10 filtering 158/2000ml at 0.47ml/s with 25.9psi vacuum 15.7m deep (37.9psia) @09:52:56.17 Cartridge 10 filtering 186/2000ml at 0.46ml/s with 26.1psi vacuum 16.2m deep (38.6psia) @09:53:56.16 Cartridge 10 filtering 214/2000ml at 0.46ml/s with 24.6psi vacuum 13.8m deep (35.0psia) @09:54:56.16 Cartridge 10 filtering 242/2000ml at 0.46ml/s with 27.5psi vacuum 15.8m deep (38.0psia) @09:55:56.15 Cartridge 10 filtering 268/2000ml at 0.45ml/s with 20.2psi vacuum 19.0m deep (42.8psia) @09:56:56.17 Cartridge 10 filtering 294/2000ml at 0.43ml/s with 17.8psi vacuum 19.9m deep (44.1psia) @09:57:56.16 Cartridge 10 filtering 319/2000ml at 0.41ml/s with 27.5psi vacuum 14.2m deep (35.7psia) @09:58:56.16 Cartridge 10 filtering 344/2000ml at 0.42ml/s with 26.6psi vacuum 13.5m deep (34.6psia) @09:59:56.16 Cartridge 10 filtering 368/2000ml at 0.38ml/s with 25.0psi vacuum 16.6m deep (39.2psia) @10:00:56.16 Cartridge 10 filtering 391/2000ml at 0.37ml/s with 22.2psi vacuum 17.9m deep (41.2psia) @10:01:56.17 Cartridge 10 filtering 414/2000ml at 0.37ml/s with 22.1psi vacuum 18.7m deep (42.4psia) @10:02:56.58 Cartridge 10 filtering 437/2000ml at 0.38ml/s with 21.6psi vacuum 16.7m deep (39.4psia) @10:03:56.17 Cartridge 10 filtering 459/2000ml at 0.34ml/s with 24.7psi vacuum 16.6m deep (39.3psia) @10:04:56.17 Cartridge 10 filtering 480/2000ml at 0.37ml/s with 27.3psi vacuum 16.3m deep (38.8psia) @10:05:56.16 Cartridge 10 filtering 501/2000ml at 0.35ml/s with 17.6psi vacuum 20.1m deep (44.5psia) @10:06:56.17 Cartridge 10 filtering 522/2000ml at 0.35ml/s with 27.3psi vacuum 15.8m deep (38.0psia) @10:07:56.16 Cartridge 10 filtering 542/2000ml at 0.32ml/s with 25.4psi vacuum 13.4m deep (34.5psia) @10:08:56.16 Cartridge 10 filtering 561/2000ml at 0.34ml/s with 26.7psi vacuum 16.3m deep (38.8psia) @10:09:56.17 Cartridge 10 filtering 581/2000ml at 0.34ml/s with 24.8psi vacuum 18.3m deep (41.8psia) @10:10:56.16 Cartridge 10 filtering 600/2000ml at 0.31ml/s with 22.2psi vacuum 18.7m deep (42.3psia) @10:11:56.16 Cartridge 10 filtering 618/2000ml at 0.33ml/s with 21.0psi vacuum 18.8m deep (42.5psia) @10:12:56.16 Cartridge 10 filtering 637/2000ml at 0.31ml/s with 27.9psi vacuum 13.7m deep (34.9psia) @10:13:56.17 Cartridge 10 filtering 655/2000ml at 0.30ml/s with 19.6psi vacuum 18.1m deep (41.5psia) @10:14:56.17 Cartridge 10 filtering 672/2000ml at 0.31ml/s with 25.9psi vacuum 17.3m deep (40.3psia) @10:15:56.16 Cartridge 10 filtering 690/2000ml at 0.28ml/s with 26.4psi vacuum 15.6m deep (37.7psia) @10:16:56.16 Cartridge 10 filtering 707/2000ml at 0.26ml/s with 21.6psi vacuum 16.4m deep (38.9psia) @10:17:56.21 Cartridge 10 filtering 724/2000ml at 0.26ml/s with 24.7psi vacuum 16.2m deep (38.6psia) @10:18:56.17 Cartridge 10 filtering 740/2000ml at 0.29ml/s with 24.8psi vacuum 16.5m deep (39.1psia) @10:19:56.16 Cartridge 10 filtering 756/2000ml at 0.26ml/s with 22.1psi vacuum 18.3m deep (41.7psia) @10:20:56.17 Cartridge 10 filtering 772/2000ml at 0.28ml/s with 23.2psi vacuum 19.1m deep (42.9psia) @10:21:56.16 Cartridge 10 filtering 788/2000ml at 0.27ml/s with 18.6psi vacuum 20.4m deep (44.8psia) @10:22:56.16 Cartridge 10 filtering 804/2000ml at 0.25ml/s with 26.0psi vacuum 16.0m deep (38.3psia) @10:23:56.17 Cartridge 10 filtering 819/2000ml at 0.24ml/s with 25.1psi vacuum 14.3m deep (35.8psia) @10:24:56.16 Cartridge 10 filtering 834/2000ml at 0.24ml/s with 20.5psi vacuum 18.2m deep (41.5psia) @10:25:56.16 Cartridge 10 filtering 849/2000ml at 0.24ml/s with 24.6psi vacuum 17.2m deep (40.2psia) @10:26:56.16 Cartridge 10 filtering 863/2000ml at 0.26ml/s with 25.2psi vacuum 17.5m deep (40.6psia) @10:27:56.16 Cartridge 10 filtering 878/2000ml at 0.22ml/s with 24.7psi vacuum 15.8m deep (38.0psia) @10:28:56.16 Cartridge 10 filtering 892/2000ml at 0.27ml/s with 25.7psi vacuum 16.4m deep (38.9psia) @10:29:56.16 Cartridge 10 filtering 906/2000ml at 0.24ml/s with 25.0psi vacuum 17.2m deep (40.1psia) @10:30:56.21 Cartridge 10 filtering 920/2000ml at 0.22ml/s with 20.7psi vacuum 18.4m deep (41.8psia) @10:31:56.16 Cartridge 10 filtering 934/2000ml at 0.23ml/s with 18.6psi vacuum 17.1m deep (40.0psia) @10:32:56.16 Cartridge 10 filtering 947/2000ml at 0.22ml/s with 26.6psi vacuum 15.5m deep (37.6psia) @10:33:56.16 Cartridge 10 filtering 961/2000ml at 0.21ml/s with 23.8psi vacuum 16.4m deep (39.0psia) @10:34:56.16 Cartridge 10 filtering 974/2000ml at 0.21ml/s with 25.3psi vacuum 16.0m deep (38.3psia) @10:35:56.16 Cartridge 10 filtering 987/2000ml at 0.21ml/s with 20.4psi vacuum 17.7m deep (40.8psia) @10:36:56.16 Cartridge 10 filtering 1000/2000ml at 0.23ml/s with 18.2psi vacuum 19.8m deep (44.0psia) @10:37:56.17 Cartridge 10 filtering 1013/2000ml at 0.21ml/s with 23.0psi vacuum 18.1m deep (41.5psia) @10:38:56.54 Cartridge 10 filtering 1025/2000ml at 0.24ml/s with 21.9psi vacuum 19.0m deep (42.7psia) @10:39:56.17 Cartridge 10 filtering 1038/2000ml at 0.20ml/s with 23.2psi vacuum 16.0m deep (38.3psia) @10:40:56.16 Cartridge 10 filtering 1051/2000ml at 0.20ml/s with 24.3psi vacuum 11.4m deep (31.6psia) @10:41:56.16 Cartridge 10 filtering 1063/2000ml at 0.20ml/s with 26.1psi vacuum 16.6m deep (39.3psia) @10:42:56.16 Cartridge 10 filtering 1076/2000ml at 0.23ml/s with 19.4psi vacuum 20.0m deep (44.3psia) @10:43:45.68 Flow averaged 0.32ml/s over 56:53 @10:43:45.72 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @10:43:46.30 Relieved excess vacuum in .6 seconds @10:43:46.34 SamplePump.seek 2000ml,1:16:39 @10:43:56.15 Cartridge 10 filtering 1088/2000ml at 0.20ml/s with 26.3psi vacuum 15.3m deep (37.3psia) @10:44:56.17 Cartridge 10 filtering 1100/2000ml at 0.20ml/s with 26.1psi vacuum 16.2m deep (38.7psia) @10:45:56.16 Cartridge 10 filtering 1113/2000ml at 0.23ml/s with 26.9psi vacuum 16.2m deep (38.7psia) @10:46:10.83 Flow averaged 0.21ml/s over 2:25 @10:46:10.88 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @10:46:11.46 Relieved excess vacuum in .6 seconds @10:46:11.49 SamplePump.seek 2000ml,1:14:10 @10:46:56.15 Cartridge 10 filtering 1125/2000ml at 0.20ml/s with 26.4psi vacuum 15.6m deep (37.8psia) @10:47:34.10 Flow averaged 0.21ml/s over 1:23 @10:47:34.14 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @10:47:34.73 Relieved excess vacuum in .6 seconds @10:47:34.76 SamplePump.seek 2000ml,1:12:45 @10:47:56.16 Cartridge 10 filtering 1137/2000ml at 0.20ml/s with 24.5psi vacuum 11.3m deep (31.4psia) @10:48:31.38 Flow averaged 0.21ml/s over 57 seconds @10:48:31.42 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @10:48:32.01 Relieved excess vacuum in .6 seconds @10:48:32.04 SamplePump.seek 2000ml,1:11:46 @10:48:56.15 Cartridge 10 filtering 1149/2000ml at 0.20ml/s with 28.4psi vacuum 15.1m deep (36.9psia) @10:49:56.16 Cartridge 10 filtering 1162/2000ml at 0.20ml/s with 28.6psi vacuum 14.7m deep (36.4psia) @10:49:56.82 Flow averaged 0.21ml/s over 1:25 @10:49:56.86 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @10:49:57.44 Relieved excess vacuum in .6 seconds @10:49:57.47 SamplePump.seek 2000ml,1:10:19 @10:50:27.35 Flow averaged 0.20ml/s over 30 seconds @10:50:27.39 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @10:50:27.98 Relieved excess vacuum in .6 seconds @10:50:28.01 SamplePump.seek 2000ml,1:09:49 @10:50:56.16 Cartridge 10 filtering 1174/2000ml at 0.20ml/s with 25.6psi vacuum 15.9m deep (38.3psia) @10:51:07.77 Flow averaged 0.20ml/s over 40 seconds @10:51:07.81 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @10:51:08.40 Relieved excess vacuum in .6 seconds @10:51:08.43 SamplePump.seek 2000ml,1:09:08 @10:51:35.52 Flow averaged 0.20ml/s over 28 seconds @10:51:35.57 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @10:51:36.33 Relieved excess vacuum in .8 seconds @10:51:36.36 SamplePump.seek 2000ml,1:08:41 @10:51:56.16 Cartridge 10 filtering 1186/2000ml at 0.20ml/s with 27.4psi vacuum 15.1m deep (36.9psia) @10:52:15.84 Flow averaged 0.20ml/s over 40 seconds @10:52:15.88 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @10:52:16.46 Relieved excess vacuum in .6 seconds @10:52:16.49 SamplePump.seek 2000ml,1:08:00 @10:52:37.25 Flow averaged 0.20ml/s over 21 seconds @10:52:37.29 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @10:52:37.88 Relieved excess vacuum in .6 seconds @10:52:37.91 SamplePump.seek 2000ml,1:07:39 @10:52:44.26 Flow estimate reduced to 0.16ml/s @10:52:44.29 Intake.close @10:52:44.36 Exhaust.close @10:52:44.58 Toroid.in :hold @10:52:44.65 Toroid.seek :bypass @10:52:46.30 Toroid.in :default @10:52:46.38 Toroid.seek :clear @10:52:48.01 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @10:52:48.03 Pressure.stop @10:52:48.22 Sampled 1195.1ml @10:52:50.15 -> Cmd.startProcessing @10:52:50.65 Plunge.seek :reagent @10:52:51.55 Sample loop closed. Ready to Deliver Reagents @10:52:51.57 Archive.seek :sealed @10:52:55.23 Archive.seek :evac @10:53:09.24 delay 1:00 @10:54:09.27 Archive.seek :clear @10:54:26.44 Sample preserved. Puck Full. @10:54:27.52 -> Cmd.stop @10:54:27.61 Carousel.in :default @10:54:27.73 Carousel.home.seek 10 @10:54:28.04 Plunge.seek :locked @10:54:29.07 Air.in :unlocking @10:54:29.22 Lysis1.in :unlocking @10:54:29.25 Air.seek :clear @10:54:29.43 Lysis1.seek :clear @10:54:30.70 Gate.power :motor,:OFF @10:54:30.71 Gate.power :core,:OFF @10:54:30.74 Gate.power :analytic1,:OFF @10:54:30.76 Gate.power :analytic2,:OFF @10:54:30.78 Gate.power :analytic3,:OFF @10:54:30.81 Gate.power :main,:OFF @10:54:30.83 Safely stopped and ready to power off ##-- file closed 2023-08-13T11:02:38.626Z ##-- file opened 2023-08-13T11:02:38.628Z @11:02:38.58 -> showStatus @11:02:40.60 -> Cmd.loadCartridge -1 @11:02:40.67 Gate.power :main,:ON,limit to 5000mA @11:02:40.69 Gate.power :analytic1,:ON,limit to 5000mA @11:02:40.71 Gate.power :analytic2,:ON,limit to 5000mA @11:02:40.74 Gate.power :analytic3,:ON,limit to 5000mA @11:02:40.79 Powering core bus @11:02:43.57 Archive.configure :default @11:02:43.66 Air.configure :default @11:02:43.73 Lysis1.configure :default @11:02:43.80 Lysis2.configure :default @11:02:43.89 Plunge.configure :default @11:02:43.98 SamplePump.configure :default @11:02:44.07 Toroid.configure :default @11:02:44.16 Carousel.configure :default @11:02:44.25 Pressure.configure :default @11:02:44.34 ExtraPump.configure :default @11:02:44.41 All elf controllers running firmware version 4.83 @11:02:44.44 Gate.power :motor,:ON,limit to 5000mA @11:02:44.59 Archive.home.jog 0 @11:02:45.09 Toroid.home.jog 0 @11:02:45.13 Plunge.home.jog 0 @11:02:45.15 Lysis2.home.jog 0 @11:02:45.23 Air.home.jog 0 @11:02:45.24 Carousel.home.jog 0 @11:02:45.28 Lysis1.home.jog 0 @11:02:45.76 Archive.in :homing @11:02:45.98 Archive.jog 1355 @11:02:46.02 Plunge.in :homing @11:02:46.05 Lysis2.in :homing @11:02:46.09 Lysis1.in :homing @11:02:46.13 Air.in :homing @11:02:46.17 Toroid.in :homing @11:02:46.36 Plunge.jog 765 @11:02:46.39 Lysis1.jog 1359 @11:02:46.46 Toroid.jog 600 @11:02:46.49 Lysis2.jog 1359 @11:02:46.54 Air.jog 167 @11:02:47.10 Air.setRawPosition! 50 @11:02:47.16 Air.seek :home @11:02:47.36 Archive.setRawPosition! 50 @11:02:47.43 Archive.seek :home @11:02:47.51 Air.in :default @11:02:47.54 Plunge.setRawPosition! 50 @11:02:47.64 Plunge.seek :home @11:02:47.73 Lysis1.setRawPosition! 50 @11:02:47.76 Archive.in :default @11:02:47.83 Lysis1.seek :home @11:02:47.97 Lysis2.setRawPosition! 50 @11:02:48.00 Plunge.in :default @11:02:48.06 Lysis2.seek :home @11:02:48.20 Lysis1.in :default @11:02:48.38 Lysis2.in :default @11:02:48.66 Toroid.setRawPosition! 0 @11:02:48.71 Toroid.seek :home @11:02:48.80 Toroid.in :default @11:02:48.87 Toroid.seek :clear @11:02:50.49 Carousel.in :default @11:02:50.61 Carousel.home.seek 10 @11:02:50.88 Selecting Cartridge 9 @11:02:51.10 Carousel.seek 9 @11:02:51.59 Lysis1.in :fast @11:02:51.66 Lysis1.seek :locked @11:02:53.90 Plunge.seek :locked @11:02:54.40 Air.in :fast @11:02:54.48 Air.seek :locked @11:02:56.02 Carousel.reconfigure :locked @11:02:56.67 Mounted archive Cartridge @11:03:12.52 -> Cmd.startFiltering @11:03:12.77 Preparing to filter cartridge 9 @11:03:13.07 Priming sample loop w/100ml, bypass w/10ml @11:03:13.09 SamplePump.setPosition! 0ml @11:03:13.14 Bypass.open @11:03:14.61 Intake.open @11:03:15.37 Sea 16.0m deep (38.3psia) @11:03:15.39 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @11:03:17.98 Vacuum tare is 51% of full scale @11:03:18.13 Intake.close @11:03:18.18 Bypass.close @11:03:18.86 Verifying toroid holds at least 0.6..0.85 of 38.3psia @11:03:18.88 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @11:03:23.46 Bypass.open @11:03:24.15 Intake.open @11:03:25.58 Pressure.in :default @11:03:25.65 Pressure.hold @11:03:25.84 SamplePump.in :prime @11:03:25.91 SamplePump.seek 10ml,59 seconds @11:03:36.76 Pressure.stop @11:03:36.81 SamplePump.setPosition! 0ml @11:03:36.87 Exhaust.open @11:03:38.37 Bypass.close @11:03:39.87 Pressure.in :default @11:03:39.93 Pressure.hold @11:03:40.06 Sea 16.0m deep (38.3psia) @11:03:40.21 SamplePump.in :prime @11:03:40.28 SamplePump.seek 100ml,5:16 @11:05:28.38 Pressure.stop @11:05:28.46 Bypass.open @11:05:29.15 Intake.close @11:05:29.89 Toroid.in :hold @11:05:29.96 Toroid.seek :crack @11:05:31.69 Toroid.seek :cartridge @11:05:32.67 Toroid.in :default @11:05:32.74 Toroid.seek :clear @11:05:34.79 Exhaust.close @11:05:34.87 Bypass.close @11:05:35.54 Verifying cartridge holds at least 0.65..0.85 of 38.2psia @11:05:35.56 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @11:05:40.19 Sampling 2000.0ml @11:05:40.21 SamplePump.setPosition! 0ml @11:05:40.27 Exhaust.open @11:05:40.95 Intake.open @11:05:41.77 Pressure.in :default @11:05:41.84 Pressure.hold @11:05:41.96 Sea 16.0m deep (38.4psia) @11:05:41.98 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @11:05:42.18 SamplePump.in :sample @11:05:42.25 SamplePump.seek 2000ml,2:47:06 @11:05:44.80 Cartridge 9 filtering 1/2000ml at 0.54ml/s with 20.3psi vacuum 18.3m deep (41.7psia) @11:06:44.81 Cartridge 9 filtering 32/2000ml at 0.53ml/s with 23.9psi vacuum 16.7m deep (39.4psia) @11:07:44.81 Cartridge 9 filtering 63/2000ml at 0.53ml/s with 25.8psi vacuum 17.0m deep (39.9psia) @11:08:44.81 Cartridge 9 filtering 94/2000ml at 0.48ml/s with 26.6psi vacuum 11.0m deep (31.0psia) @11:09:44.81 Cartridge 9 filtering 123/2000ml at 0.46ml/s with 25.3psi vacuum 10.6m deep (30.4psia) @11:10:44.81 Cartridge 9 filtering 152/2000ml at 0.49ml/s with 22.5psi vacuum 19.5m deep (43.5psia) @11:11:44.81 Cartridge 9 filtering 179/2000ml at 0.48ml/s with 26.4psi vacuum 16.5m deep (39.0psia) @11:12:44.81 Cartridge 9 filtering 207/2000ml at 0.47ml/s with 22.4psi vacuum 19.5m deep (43.6psia) @11:13:44.81 Cartridge 9 filtering 233/2000ml at 0.45ml/s with 25.4psi vacuum 16.8m deep (39.6psia) @11:14:44.81 Cartridge 9 filtering 259/2000ml at 0.44ml/s with 24.8psi vacuum 11.8m deep (32.1psia) @11:15:44.81 Cartridge 9 filtering 285/2000ml at 0.42ml/s with 21.4psi vacuum 17.8m deep (41.0psia) @11:16:44.81 Cartridge 9 filtering 310/2000ml at 0.42ml/s with 24.0psi vacuum 16.8m deep (39.5psia) @11:17:44.81 Cartridge 9 filtering 334/2000ml at 0.39ml/s with 19.6psi vacuum 14.8m deep (36.6psia) @11:18:44.81 Cartridge 9 filtering 358/2000ml at 0.40ml/s with 24.0psi vacuum 13.0m deep (33.9psia) @11:19:44.81 Cartridge 9 filtering 381/2000ml at 0.40ml/s with 21.1psi vacuum 17.9m deep (41.2psia) @11:20:44.82 Cartridge 9 filtering 404/2000ml at 0.36ml/s with 25.2psi vacuum 13.1m deep (34.1psia) @11:21:45.23 Cartridge 9 filtering 427/2000ml at 0.36ml/s with 24.1psi vacuum 19.1m deep (43.0psia) @11:22:44.81 Cartridge 9 filtering 449/2000ml at 0.36ml/s with 25.3psi vacuum 10.7m deep (30.4psia) @11:23:44.81 Cartridge 9 filtering 471/2000ml at 0.36ml/s with 22.7psi vacuum 19.2m deep (43.1psia) @11:24:44.81 Cartridge 9 filtering 493/2000ml at 0.37ml/s with 24.2psi vacuum 16.1m deep (38.5psia) @11:25:44.82 Cartridge 9 filtering 514/2000ml at 0.37ml/s with 27.4psi vacuum 15.9m deep (38.2psia) @11:26:44.81 Cartridge 9 filtering 535/2000ml at 0.35ml/s with 27.2psi vacuum 15.9m deep (38.2psia) @11:27:44.82 Cartridge 9 filtering 555/2000ml at 0.34ml/s with 27.1psi vacuum 16.2m deep (38.6psia) @11:28:44.81 Cartridge 9 filtering 575/2000ml at 0.34ml/s with 16.6psi vacuum 22.8m deep (48.4psia) @11:29:44.82 Cartridge 9 filtering 595/2000ml at 0.34ml/s with 18.5psi vacuum 20.8m deep (45.4psia) @11:30:44.81 Cartridge 9 filtering 614/2000ml at 0.31ml/s with 26.4psi vacuum 14.8m deep (36.6psia) @11:31:44.82 Cartridge 9 filtering 633/2000ml at 0.30ml/s with 24.3psi vacuum 13.7m deep (34.9psia) @11:32:44.81 Cartridge 9 filtering 652/2000ml at 0.31ml/s with 26.8psi vacuum 15.5m deep (37.6psia) @11:33:44.81 Cartridge 9 filtering 671/2000ml at 0.30ml/s with 25.6psi vacuum 16.4m deep (39.0psia) @11:34:44.82 Cartridge 9 filtering 689/2000ml at 0.29ml/s with 25.0psi vacuum 15.6m deep (37.7psia) @11:35:44.82 Cartridge 9 filtering 707/2000ml at 0.30ml/s with 27.7psi vacuum 11.7m deep (31.9psia) @11:36:44.81 Cartridge 9 filtering 725/2000ml at 0.28ml/s with 23.9psi vacuum 12.5m deep (33.2psia) @11:37:44.82 Cartridge 9 filtering 742/2000ml at 0.28ml/s with 23.9psi vacuum 17.3m deep (40.3psia) @11:38:44.81 Cartridge 9 filtering 760/2000ml at 0.29ml/s with 16.3psi vacuum 20.8m deep (45.4psia) @11:39:44.81 Cartridge 9 filtering 777/2000ml at 0.27ml/s with 26.2psi vacuum 15.8m deep (38.0psia) @11:40:44.81 Cartridge 9 filtering 794/2000ml at 0.29ml/s with 15.6psi vacuum 22.8m deep (48.4psia) @11:41:44.81 Cartridge 9 filtering 811/2000ml at 0.27ml/s with 25.4psi vacuum 16.5m deep (39.1psia) @11:42:44.81 Cartridge 9 filtering 827/2000ml at 0.30ml/s with 25.1psi vacuum 16.6m deep (39.2psia) @11:43:44.81 Cartridge 9 filtering 844/2000ml at 0.26ml/s with 25.0psi vacuum 16.1m deep (38.6psia) @11:44:44.82 Cartridge 9 filtering 860/2000ml at 0.27ml/s with 14.9psi vacuum 22.5m deep (48.0psia) @11:45:44.81 Cartridge 9 filtering 876/2000ml at 0.25ml/s with 24.2psi vacuum 13.9m deep (35.2psia) @11:46:44.81 Cartridge 9 filtering 891/2000ml at 0.25ml/s with 24.6psi vacuum 16.0m deep (38.3psia) @11:47:44.82 Cartridge 9 filtering 907/2000ml at 0.24ml/s with 23.7psi vacuum 13.3m deep (34.3psia) @11:48:44.81 Cartridge 9 filtering 922/2000ml at 0.24ml/s with 26.4psi vacuum 15.0m deep (36.9psia) @11:49:44.81 Cartridge 9 filtering 938/2000ml at 0.28ml/s with 21.7psi vacuum 19.9m deep (44.0psia) @11:50:44.81 Cartridge 9 filtering 953/2000ml at 0.24ml/s with 26.5psi vacuum 15.7m deep (37.9psia) @11:51:44.81 Cartridge 9 filtering 968/2000ml at 0.23ml/s with 23.0psi vacuum 14.2m deep (35.7psia) @11:52:44.81 Cartridge 9 filtering 982/2000ml at 0.25ml/s with 24.9psi vacuum 17.9m deep (41.1psia) @11:53:44.81 Cartridge 9 filtering 997/2000ml at 0.23ml/s with 24.7psi vacuum 16.5m deep (39.1psia) @11:54:44.82 Cartridge 9 filtering 1011/2000ml at 0.23ml/s with 26.1psi vacuum 16.2m deep (38.7psia) @11:55:44.81 Cartridge 9 filtering 1026/2000ml at 0.22ml/s with 24.2psi vacuum 15.5m deep (37.6psia) @11:56:44.81 Cartridge 9 filtering 1040/2000ml at 0.24ml/s with 24.8psi vacuum 17.5m deep (40.5psia) @11:57:45.19 Cartridge 9 filtering 1054/2000ml at 0.22ml/s with 23.3psi vacuum 16.1m deep (38.5psia) @11:58:44.81 Cartridge 9 filtering 1068/2000ml at 0.23ml/s with 26.5psi vacuum 15.9m deep (38.3psia) @11:59:44.82 Cartridge 9 filtering 1081/2000ml at 0.21ml/s with 24.1psi vacuum 15.2m deep (37.1psia) @12:00:44.82 Cartridge 9 filtering 1095/2000ml at 0.22ml/s with 27.0psi vacuum 15.3m deep (37.3psia) @12:01:44.81 Cartridge 9 filtering 1108/2000ml at 0.21ml/s with 23.3psi vacuum 17.2m deep (40.1psia) @12:02:44.82 Cartridge 9 filtering 1122/2000ml at 0.21ml/s with 23.1psi vacuum 17.3m deep (40.3psia) @12:03:44.82 Cartridge 9 filtering 1135/2000ml at 0.23ml/s with 27.4psi vacuum 17.2m deep (40.2psia) @12:04:44.82 Cartridge 9 filtering 1148/2000ml at 0.20ml/s with 25.0psi vacuum 16.1m deep (38.4psia) @12:05:44.81 Cartridge 9 filtering 1161/2000ml at 0.24ml/s with 25.0psi vacuum 19.1m deep (42.9psia) @12:06:44.81 Cartridge 9 filtering 1174/2000ml at 0.20ml/s with 23.1psi vacuum 17.2m deep (40.1psia) @12:07:44.81 Cartridge 9 filtering 1186/2000ml at 0.24ml/s with 25.2psi vacuum 18.1m deep (41.4psia) @12:08:44.82 Cartridge 9 filtering 1199/2000ml at 0.21ml/s with 25.4psi vacuum 16.4m deep (38.9psia) @12:09:44.81 Cartridge 9 filtering 1212/2000ml at 0.20ml/s with 24.7psi vacuum 16.1m deep (38.6psia) @12:10:44.81 Cartridge 9 filtering 1224/2000ml at 0.20ml/s with 25.0psi vacuum 16.9m deep (39.7psia) @12:11:44.81 Cartridge 9 filtering 1237/2000ml at 0.20ml/s with 24.8psi vacuum 16.3m deep (38.7psia) @12:12:44.81 Cartridge 9 filtering 1249/2000ml at 0.20ml/s with 25.7psi vacuum 16.3m deep (38.8psia) @12:13:44.81 Cartridge 9 filtering 1262/2000ml at 0.20ml/s with 25.7psi vacuum 16.7m deep (39.4psia) @12:14:44.82 Cartridge 9 filtering 1274/2000ml at 0.20ml/s with 22.8psi vacuum 17.0m deep (39.8psia) @12:15:44.82 Cartridge 9 filtering 1286/2000ml at 0.20ml/s with 26.9psi vacuum 15.5m deep (37.6psia) @12:16:04.01 Flow averaged 0.31ml/s over 1:10:22 @12:16:04.05 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @12:16:04.64 Relieved excess vacuum in .6 seconds @12:16:04.67 SamplePump.seek 2000ml,59:37 @12:16:44.81 Cartridge 9 filtering 1299/2000ml at 0.20ml/s with 25.8psi vacuum 16.8m deep (39.6psia) @12:17:44.81 Cartridge 9 filtering 1311/2000ml at 0.21ml/s with 29.9psi vacuum 15.3m deep (37.4psia) @12:18:44.81 Cartridge 9 filtering 1323/2000ml at 0.20ml/s with 26.2psi vacuum 16.8m deep (39.5psia) @12:19:12.37 Flow averaged 0.21ml/s over 3:08 @12:19:12.41 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @12:19:12.99 Relieved excess vacuum in .6 seconds @12:19:13.02 SamplePump.seek 2000ml,56:23 @12:19:44.81 Cartridge 9 filtering 1336/2000ml at 0.20ml/s with 26.3psi vacuum 16.2m deep (38.6psia) @12:20:44.81 Cartridge 9 filtering 1348/2000ml at 0.20ml/s with 20.2psi vacuum 16.2m deep (38.6psia) @12:20:49.13 Flow averaged 0.21ml/s over 1:37 @12:20:49.18 Waiting up to 11 seconds for vacuum to reduce from 27.2 to 18.0psi @12:20:49.77 Relieved excess vacuum in .6 seconds @12:20:49.80 SamplePump.seek 2000ml,54:44 @12:21:44.80 Cartridge 9 filtering 1360/2000ml at 0.23ml/s with 26.8psi vacuum 18.8m deep (42.5psia) @12:22:19.49 Flow averaged 0.21ml/s over 1:30 @12:22:19.53 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @12:22:20.49 Relieved excess vacuum in 1 second @12:22:20.52 SamplePump.seek 2000ml,53:12 @12:22:44.81 Cartridge 9 filtering 1372/2000ml at 0.20ml/s with 26.6psi vacuum 16.6m deep (39.3psia) @12:23:44.82 Cartridge 9 filtering 1385/2000ml at 0.20ml/s with 26.7psi vacuum 16.2m deep (38.7psia) @12:23:58.22 Flow averaged 0.21ml/s over 1:38 @12:23:58.26 Waiting up to 11 seconds for vacuum to reduce from 27.3 to 18.0psi @12:23:58.84 Relieved excess vacuum in .6 seconds @12:23:58.87 SamplePump.seek 2000ml,51:31 @12:24:44.81 Cartridge 9 filtering 1397/2000ml at 0.20ml/s with 26.1psi vacuum 15.9m deep (38.2psia) @12:25:02.26 Flow averaged 0.21ml/s over 1:04 @12:25:02.29 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @12:25:02.88 Relieved excess vacuum in .6 seconds @12:25:02.90 SamplePump.seek 2000ml,50:27 @12:25:44.81 Cartridge 9 filtering 1409/2000ml at 0.20ml/s with 26.3psi vacuum 16.4m deep (39.0psia) @12:25:54.85 Flow averaged 0.20ml/s over 52 seconds @12:25:54.90 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @12:25:55.48 Relieved excess vacuum in .6 seconds @12:25:55.51 SamplePump.seek 2000ml,49:33 @12:26:34.59 Flow averaged 0.20ml/s over 40 seconds @12:26:34.63 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @12:26:35.22 Relieved excess vacuum in .6 seconds @12:26:35.25 SamplePump.seek 2000ml,48:53 @12:26:44.81 Cartridge 9 filtering 1421/2000ml at 0.20ml/s with 26.3psi vacuum 16.1m deep (38.5psia) @12:27:11.61 Flow averaged 0.20ml/s over 37 seconds @12:27:11.66 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @12:27:12.24 Relieved excess vacuum in .6 seconds @12:27:12.27 SamplePump.seek 2000ml,48:16 @12:27:44.81 Cartridge 9 filtering 1433/2000ml at 0.20ml/s with 26.3psi vacuum 16.0m deep (38.4psia) @12:27:57.20 Flow averaged 0.20ml/s over 45 seconds @12:27:57.25 Waiting up to 11 seconds for vacuum to reduce from 27.3 to 18.0psi @12:27:57.83 Relieved excess vacuum in .6 seconds @12:27:57.86 SamplePump.seek 2000ml,47:30 @12:28:22.11 Flow averaged 0.20ml/s over 25 seconds @12:28:22.15 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @12:28:22.74 Relieved excess vacuum in .6 seconds @12:28:22.77 SamplePump.seek 2000ml,47:06 @12:28:42.72 Flow averaged 0.20ml/s over 20 seconds @12:28:42.76 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @12:28:43.34 Relieved excess vacuum in .6 seconds @12:28:43.37 SamplePump.seek 2000ml,46:45 @12:28:44.80 Cartridge 9 filtering 1445/2000ml at 0.20ml/s with 25.7psi vacuum 12.6m deep (33.4psia) @12:29:15.72 Flow averaged 0.20ml/s over 33 seconds @12:29:15.76 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @12:29:16.34 Relieved excess vacuum in .6 seconds @12:29:16.37 SamplePump.seek 2000ml,46:12 @12:29:34.55 Flow averaged 0.20ml/s over 19 seconds @12:29:34.57 Intake.close @12:29:34.65 Exhaust.close @12:29:34.85 Toroid.in :hold @12:29:34.92 Toroid.seek :bypass @12:29:36.58 Toroid.in :default @12:29:36.65 Toroid.seek :clear @12:29:38.28 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @12:29:38.30 Pressure.stop @12:29:38.49 Sampled 1455.0ml @12:29:40.53 -> Cmd.startProcessing @12:29:40.97 Plunge.seek :reagent @12:29:41.87 Sample loop closed. Ready to Deliver Reagents @12:29:41.89 Archive.seek :sealed @12:29:45.54 Archive.seek :evac @12:29:59.55 delay 1:00 @12:30:59.58 Archive.seek :clear @12:31:16.75 Sample preserved. Puck Full. @12:31:17.89 -> Cmd.stop @12:31:17.99 Carousel.in :default @12:31:18.11 Carousel.home.seek 9 @12:31:18.41 Plunge.seek :locked @12:31:19.44 Air.in :unlocking @12:31:19.56 Air.seek :clear @12:31:19.66 Lysis1.in :unlocking @12:31:19.80 Lysis1.seek :clear @12:31:21.04 Gate.power :motor,:OFF @12:31:21.06 Gate.power :core,:OFF @12:31:21.08 Gate.power :analytic1,:OFF @12:31:21.10 Gate.power :analytic2,:OFF @12:31:21.13 Gate.power :analytic3,:OFF @12:31:21.15 Gate.power :main,:OFF @12:31:21.17 Safely stopped and ready to power off ##-- file closed 2023-08-13T12:39:34.066Z ##-- file opened 2023-08-13T12:39:34.069Z @12:39:34.10 -> showStatus @12:39:36.12 -> Cmd.loadCartridge -1 @12:39:36.18 Gate.power :main,:ON,limit to 5000mA @12:39:36.21 Gate.power :analytic1,:ON,limit to 5000mA @12:39:36.57 Gate.power :analytic2,:ON,limit to 5000mA @12:39:36.61 Gate.power :analytic3,:ON,limit to 5000mA @12:39:36.66 Powering core bus @12:39:39.36 Archive.configure :default @12:39:39.45 Air.configure :default @12:39:39.52 Lysis1.configure :default @12:39:39.59 Lysis2.configure :default @12:39:39.68 Plunge.configure :default @12:39:39.76 SamplePump.configure :default @12:39:39.86 Toroid.configure :default @12:39:39.95 Carousel.configure :default @12:39:40.04 Pressure.configure :default @12:39:40.14 ExtraPump.configure :default @12:39:40.20 All elf controllers running firmware version 4.83 @12:39:40.23 Gate.power :motor,:ON,limit to 5000mA @12:39:40.44 Archive.home.jog 0 @12:39:40.88 Toroid.home.jog 0 @12:39:40.92 Plunge.home.jog 0 @12:39:40.95 Air.home.jog 0 @12:39:40.99 Carousel.home.jog 0 @12:39:41.02 Lysis1.home.jog 0 @12:39:41.08 Lysis2.home.jog 0 @12:39:41.49 Archive.in :homing @12:39:41.74 Archive.jog 1355 @12:39:41.78 Toroid.in :homing @12:39:41.82 Plunge.in :homing @12:39:41.87 Air.in :homing @12:39:42.04 Toroid.jog 599 @12:39:42.08 Plunge.jog 769 @12:39:42.17 Air.jog 169 @12:39:42.32 Lysis2.in :homing @12:39:42.34 Lysis1.in :homing @12:39:42.44 Lysis2.jog 1367 @12:39:42.50 Lysis1.jog 1363 @12:39:42.65 Air.setRawPosition! 50 @12:39:42.70 Air.seek :home @12:39:42.97 Air.in :default @12:39:43.06 Plunge.setRawPosition! 50 @12:39:43.12 Plunge.seek :home @12:39:43.19 Archive.setRawPosition! 50 @12:39:43.24 Archive.seek :home @12:39:43.39 Plunge.in :default @12:39:43.51 Archive.in :default @12:39:43.61 Lysis2.setRawPosition! 50 @12:39:43.68 Lysis1.setRawPosition! 50 @12:39:43.71 Lysis2.seek :home @12:39:43.81 Lysis1.seek :home @12:39:44.02 Lysis2.in :default @12:39:44.12 Lysis1.in :default @12:39:44.20 Toroid.setRawPosition! 0 @12:39:44.25 Toroid.seek :home @12:39:44.33 Toroid.in :default @12:39:44.46 Toroid.seek :clear @12:39:46.08 Carousel.in :default @12:39:46.21 Carousel.home.seek 9 @12:39:46.46 Selecting Cartridge 8 @12:39:46.69 Carousel.seek 8 @12:39:47.18 Lysis1.in :fast @12:39:47.25 Lysis1.seek :locked @12:39:49.84 Plunge.seek :locked @12:39:49.98 Air.in :fast @12:39:50.05 Air.seek :locked @12:39:51.60 Carousel.reconfigure :locked @12:39:52.25 Mounted archive Cartridge @12:40:08.04 -> Cmd.startFiltering @12:40:08.29 Preparing to filter cartridge 8 @12:40:08.58 Priming sample loop w/100ml, bypass w/10ml @12:40:08.60 SamplePump.setPosition! 0ml @12:40:08.65 Bypass.open @12:40:10.10 Intake.open @12:40:10.86 Sea 16.0m deep (38.4psia) @12:40:10.89 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @12:40:13.46 Vacuum tare is 51% of full scale @12:40:13.61 Intake.close @12:40:13.66 Bypass.close @12:40:14.38 Verifying toroid holds at least 0.6..0.85 of 38.4psia @12:40:14.40 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @12:40:18.98 Bypass.open @12:40:19.69 Intake.open @12:40:21.16 Pressure.in :default @12:40:21.22 Pressure.hold @12:40:21.42 SamplePump.in :prime @12:40:21.50 SamplePump.seek 10ml,59 seconds @12:40:32.35 Pressure.stop @12:40:32.40 SamplePump.setPosition! 0ml @12:40:32.46 Exhaust.open @12:40:33.96 Bypass.close @12:40:35.44 Pressure.in :default @12:40:35.51 Pressure.hold @12:40:35.63 Sea 16.1m deep (38.4psia) @12:40:35.78 SamplePump.in :prime @12:40:35.85 SamplePump.seek 100ml,5:16 @12:42:23.95 Pressure.stop @12:42:24.07 Bypass.open @12:42:24.78 Intake.close @12:42:25.56 Toroid.in :hold @12:42:25.63 Toroid.seek :crack @12:42:27.36 Toroid.seek :cartridge @12:42:28.34 Toroid.in :default @12:42:28.41 Toroid.seek :clear @12:42:30.45 Exhaust.close @12:42:30.48 Bypass.close @12:42:31.22 Verifying cartridge holds at least 0.65..0.85 of 38.3psia @12:42:31.24 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @12:42:35.88 Sampling 2000.0ml @12:42:35.90 SamplePump.setPosition! 0ml @12:42:35.95 Exhaust.open @12:42:36.65 Intake.open @12:42:37.51 Pressure.in :default @12:42:37.58 Pressure.hold @12:42:37.70 Sea 16.1m deep (38.4psia) @12:42:37.72 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @12:42:37.87 SamplePump.in :sample @12:42:37.95 SamplePump.seek 2000ml,2:47:06 @12:42:40.54 Cartridge 8 filtering 1/2000ml at 0.57ml/s with 24.9psi vacuum 15.0m deep (36.9psia) @12:43:40.55 Cartridge 8 filtering 33/2000ml at 0.55ml/s with 21.5psi vacuum 19.1m deep (42.9psia) @12:44:40.55 Cartridge 8 filtering 65/2000ml at 0.53ml/s with 25.9psi vacuum 16.6m deep (39.2psia) @12:45:40.55 Cartridge 8 filtering 96/2000ml at 0.51ml/s with 26.5psi vacuum 11.9m deep (32.3psia) @12:46:40.55 Cartridge 8 filtering 126/2000ml at 0.50ml/s with 26.8psi vacuum 15.7m deep (37.9psia) @12:47:40.55 Cartridge 8 filtering 155/2000ml at 0.49ml/s with 23.0psi vacuum 18.2m deep (41.6psia) @12:48:40.56 Cartridge 8 filtering 183/2000ml at 0.49ml/s with 19.2psi vacuum 22.1m deep (47.3psia) @12:49:40.55 Cartridge 8 filtering 211/2000ml at 0.46ml/s with 21.0psi vacuum 17.2m deep (40.2psia) @12:50:40.55 Cartridge 8 filtering 238/2000ml at 0.47ml/s with 20.9psi vacuum 21.4m deep (46.3psia) @12:51:40.55 Cartridge 8 filtering 265/2000ml at 0.44ml/s with 26.3psi vacuum 16.6m deep (39.2psia) @12:52:40.55 Cartridge 8 filtering 291/2000ml at 0.43ml/s with 24.1psi vacuum 17.6m deep (40.6psia) @12:53:40.55 Cartridge 8 filtering 317/2000ml at 0.43ml/s with 17.9psi vacuum 20.2m deep (44.6psia) @12:54:40.61 Cartridge 8 filtering 342/2000ml at 0.40ml/s with 25.5psi vacuum 10.4m deep (30.0psia) @12:55:40.55 Cartridge 8 filtering 366/2000ml at 0.42ml/s with 26.9psi vacuum 14.7m deep (36.3psia) @12:56:40.55 Cartridge 8 filtering 390/2000ml at 0.41ml/s with 18.2psi vacuum 20.5m deep (45.0psia) @12:57:40.92 Cartridge 8 filtering 414/2000ml at 0.40ml/s with 28.0psi vacuum 13.2m deep (34.3psia) @12:58:40.55 Cartridge 8 filtering 437/2000ml at 0.38ml/s with 25.9psi vacuum 16.9m deep (39.6psia) @12:59:40.55 Cartridge 8 filtering 460/2000ml at 0.38ml/s with 27.8psi vacuum 9.3m deep (28.5psia) @13:00:40.55 Cartridge 8 filtering 482/2000ml at 0.37ml/s with 21.6psi vacuum 20.3m deep (44.7psia) @13:01:40.55 Cartridge 8 filtering 504/2000ml at 0.35ml/s with 24.5psi vacuum 15.2m deep (37.1psia) @13:02:40.55 Cartridge 8 filtering 526/2000ml at 0.36ml/s with 15.4psi vacuum 21.8m deep (46.9psia) @13:03:40.55 Cartridge 8 filtering 547/2000ml at 0.34ml/s with 16.3psi vacuum 20.6m deep (45.2psia) @13:04:40.55 Cartridge 8 filtering 568/2000ml at 0.34ml/s with 25.5psi vacuum 15.7m deep (37.9psia) @13:05:40.55 Cartridge 8 filtering 589/2000ml at 0.33ml/s with 27.4psi vacuum 14.5m deep (36.1psia) @13:06:40.55 Cartridge 8 filtering 609/2000ml at 0.33ml/s with 25.8psi vacuum 13.1m deep (34.0psia) @13:07:40.55 Cartridge 8 filtering 629/2000ml at 0.35ml/s with 27.7psi vacuum 16.0m deep (38.4psia) @13:08:40.55 Cartridge 8 filtering 649/2000ml at 0.34ml/s with 27.7psi vacuum 16.5m deep (39.1psia) @13:09:40.55 Cartridge 8 filtering 669/2000ml at 0.35ml/s with 23.7psi vacuum 19.4m deep (43.4psia) @13:10:40.55 Cartridge 8 filtering 688/2000ml at 0.34ml/s with 23.8psi vacuum 16.2m deep (38.6psia) @13:11:40.54 Cartridge 8 filtering 707/2000ml at 0.32ml/s with 28.1psi vacuum 16.2m deep (38.6psia) @13:12:40.55 Cartridge 8 filtering 725/2000ml at 0.30ml/s with 26.2psi vacuum 15.9m deep (38.1psia) @13:13:40.55 Cartridge 8 filtering 744/2000ml at 0.29ml/s with 23.7psi vacuum 17.3m deep (40.2psia) @13:14:40.55 Cartridge 8 filtering 762/2000ml at 0.31ml/s with 26.8psi vacuum 16.3m deep (38.8psia) @13:15:40.54 Cartridge 8 filtering 780/2000ml at 0.32ml/s with 24.6psi vacuum 19.0m deep (42.7psia) @13:16:40.55 Cartridge 8 filtering 797/2000ml at 0.29ml/s with 22.9psi vacuum 13.5m deep (34.6psia) @13:17:40.55 Cartridge 8 filtering 815/2000ml at 0.28ml/s with 20.3psi vacuum 19.6m deep (43.7psia) @13:18:40.55 Cartridge 8 filtering 832/2000ml at 0.27ml/s with 25.2psi vacuum 10.5m deep (30.2psia) @13:19:40.55 Cartridge 8 filtering 849/2000ml at 0.30ml/s with 17.1psi vacuum 22.7m deep (48.2psia) @13:20:40.61 Cartridge 8 filtering 866/2000ml at 0.28ml/s with 23.0psi vacuum 18.4m deep (41.9psia) @13:21:40.55 Cartridge 8 filtering 882/2000ml at 0.30ml/s with 27.0psi vacuum 17.8m deep (40.9psia) @13:22:40.55 Cartridge 8 filtering 899/2000ml at 0.26ml/s with 25.0psi vacuum 16.4m deep (38.9psia) @13:23:40.55 Cartridge 8 filtering 915/2000ml at 0.25ml/s with 23.9psi vacuum 13.8m deep (35.1psia) @13:24:40.55 Cartridge 8 filtering 931/2000ml at 0.27ml/s with 25.3psi vacuum 17.7m deep (40.9psia) @13:25:40.55 Cartridge 8 filtering 947/2000ml at 0.28ml/s with 16.1psi vacuum 22.5m deep (48.0psia) @13:26:40.55 Cartridge 8 filtering 963/2000ml at 0.24ml/s with 24.2psi vacuum 16.5m deep (39.0psia) @13:27:40.55 Cartridge 8 filtering 978/2000ml at 0.27ml/s with 15.4psi vacuum 22.7m deep (48.2psia) @13:28:40.55 Cartridge 8 filtering 994/2000ml at 0.26ml/s with 26.2psi vacuum 17.3m deep (40.2psia) @13:29:40.55 Cartridge 8 filtering 1009/2000ml at 0.23ml/s with 23.1psi vacuum 17.3m deep (40.3psia) @13:30:40.55 Cartridge 8 filtering 1024/2000ml at 0.27ml/s with 26.1psi vacuum 18.3m deep (41.8psia) @13:31:40.55 Cartridge 8 filtering 1039/2000ml at 0.23ml/s with 25.0psi vacuum 16.3m deep (38.8psia) @13:32:40.55 Cartridge 8 filtering 1053/2000ml at 0.27ml/s with 25.7psi vacuum 16.2m deep (38.7psia) @13:33:40.92 Cartridge 8 filtering 1068/2000ml at 0.26ml/s with 25.0psi vacuum 16.7m deep (39.4psia) @13:34:40.55 Cartridge 8 filtering 1082/2000ml at 0.24ml/s with 26.9psi vacuum 16.3m deep (38.8psia) @13:35:40.55 Cartridge 8 filtering 1097/2000ml at 0.22ml/s with 23.1psi vacuum 17.0m deep (39.8psia) @13:36:40.55 Cartridge 8 filtering 1111/2000ml at 0.23ml/s with 28.0psi vacuum 15.0m deep (36.9psia) @13:37:40.55 Cartridge 8 filtering 1125/2000ml at 0.22ml/s with 22.9psi vacuum 14.9m deep (36.7psia) @13:38:40.55 Cartridge 8 filtering 1138/2000ml at 0.24ml/s with 18.3psi vacuum 21.3m deep (46.1psia) @13:39:40.55 Cartridge 8 filtering 1152/2000ml at 0.23ml/s with 22.7psi vacuum 19.1m deep (42.9psia) @13:40:40.55 Cartridge 8 filtering 1166/2000ml at 0.23ml/s with 23.8psi vacuum 18.7m deep (42.3psia) @13:41:40.55 Cartridge 8 filtering 1179/2000ml at 0.22ml/s with 26.6psi vacuum 15.1m deep (37.0psia) @13:42:40.55 Cartridge 8 filtering 1193/2000ml at 0.21ml/s with 24.8psi vacuum 16.4m deep (39.0psia) @13:43:40.55 Cartridge 8 filtering 1206/2000ml at 0.21ml/s with 24.0psi vacuum 11.9m deep (32.3psia) @13:44:40.55 Cartridge 8 filtering 1219/2000ml at 0.21ml/s with 26.7psi vacuum 16.1m deep (38.5psia) @13:45:40.55 Cartridge 8 filtering 1232/2000ml at 0.21ml/s with 23.9psi vacuum 17.2m deep (40.1psia) @13:46:40.55 Cartridge 8 filtering 1245/2000ml at 0.20ml/s with 24.5psi vacuum 15.9m deep (38.2psia) @13:47:40.54 Cartridge 8 filtering 1258/2000ml at 0.24ml/s with 25.1psi vacuum 17.8m deep (41.0psia) @13:48:40.55 Cartridge 8 filtering 1271/2000ml at 0.20ml/s with 22.1psi vacuum 12.7m deep (33.5psia) @13:49:40.55 Cartridge 8 filtering 1283/2000ml at 0.21ml/s with 17.4psi vacuum 19.7m deep (43.8psia) @13:50:40.55 Cartridge 8 filtering 1296/2000ml at 0.22ml/s with 25.2psi vacuum 16.9m deep (39.7psia) @13:51:40.55 Cartridge 8 filtering 1308/2000ml at 0.20ml/s with 26.0psi vacuum 15.6m deep (37.7psia) @13:52:40.55 Cartridge 8 filtering 1321/2000ml at 0.21ml/s with 19.1psi vacuum 16.8m deep (39.5psia) @13:53:40.55 Cartridge 8 filtering 1333/2000ml at 0.20ml/s with 26.9psi vacuum 16.3m deep (38.8psia) @13:54:40.55 Cartridge 8 filtering 1346/2000ml at 0.23ml/s with 26.9psi vacuum 16.9m deep (39.7psia) @13:55:40.55 Cartridge 8 filtering 1358/2000ml at 0.21ml/s with 15.5psi vacuum 20.7m deep (45.2psia) @13:56:40.55 Cartridge 8 filtering 1371/2000ml at 0.20ml/s with 26.2psi vacuum 16.8m deep (39.5psia) @13:57:40.55 Cartridge 8 filtering 1383/2000ml at 0.21ml/s with 23.6psi vacuum 18.8m deep (42.4psia) @13:57:49.81 Flow averaged 0.31ml/s over 1:15:12 @13:57:49.85 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @13:57:50.44 Relieved excess vacuum in .6 seconds @13:57:50.47 SamplePump.seek 2000ml,51:43 @13:58:40.54 Cartridge 8 filtering 1395/2000ml at 0.20ml/s with 25.7psi vacuum 17.0m deep (39.9psia) @13:59:40.55 Cartridge 8 filtering 1408/2000ml at 0.22ml/s with 28.9psi vacuum 17.4m deep (40.4psia) @14:00:40.55 Cartridge 8 filtering 1420/2000ml at 0.20ml/s with 26.3psi vacuum 16.5m deep (39.1psia) @14:00:48.32 Flow averaged 0.21ml/s over 2:58 @14:00:48.37 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @14:00:48.95 Relieved excess vacuum in .6 seconds @14:00:48.98 SamplePump.seek 2000ml,48:40 @14:01:40.55 Cartridge 8 filtering 1433/2000ml at 0.21ml/s with 26.5psi vacuum 15.7m deep (38.0psia) @14:02:40.55 Cartridge 8 filtering 1445/2000ml at 0.20ml/s with 26.1psi vacuum 17.1m deep (40.0psia) @14:03:06.89 Flow averaged 0.21ml/s over 2:18 @14:03:06.94 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @14:03:07.52 Relieved excess vacuum in .6 seconds @14:03:07.55 SamplePump.seek 2000ml,46:18 @14:03:40.55 Cartridge 8 filtering 1457/2000ml at 0.22ml/s with 27.7psi vacuum 18.1m deep (41.4psia) @14:04:35.16 Flow averaged 0.21ml/s over 1:28 @14:04:35.20 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @14:04:35.78 Relieved excess vacuum in .6 seconds @14:04:35.81 SamplePump.seek 2000ml,44:48 @14:04:40.54 Cartridge 8 filtering 1469/2000ml at 0.20ml/s with 24.8psi vacuum 17.5m deep (40.6psia) @14:05:40.55 Cartridge 8 filtering 1482/2000ml at 0.20ml/s with 21.8psi vacuum 13.9m deep (35.2psia) @14:06:02.82 Flow averaged 0.21ml/s over 1:28 @14:06:02.86 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:06:03.46 Relieved excess vacuum in .6 seconds @14:06:03.49 SamplePump.seek 2000ml,43:18 @14:06:40.54 Cartridge 8 filtering 1494/2000ml at 0.21ml/s with 29.6psi vacuum 15.8m deep (38.1psia) @14:07:09.13 Flow averaged 0.21ml/s over 1:06 @14:07:09.17 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @14:07:09.75 Relieved excess vacuum in .6 seconds @14:07:09.78 SamplePump.seek 2000ml,42:10 @14:07:40.55 Cartridge 8 filtering 1506/2000ml at 0.20ml/s with 26.3psi vacuum 16.8m deep (39.5psia) @14:08:09.96 Flow averaged 0.21ml/s over 1:01 @14:08:10.01 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @14:08:10.59 Relieved excess vacuum in .6 seconds @14:08:10.62 SamplePump.seek 2000ml,41:09 @14:08:39.89 Flow averaged 0.20ml/s over 30 seconds @14:08:39.93 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @14:08:40.58 Cartridge 8 filtering 1518/2000ml at 0.00ml/s with -0.2psi vacuum 16.4m deep (39.0psia) @14:08:40.63 Relieved excess vacuum in .7 seconds @14:08:40.66 SamplePump.seek 2000ml,40:39 @14:09:37.30 Flow averaged 0.21ml/s over 57 seconds @14:09:37.34 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @14:09:37.92 Relieved excess vacuum in .6 seconds @14:09:37.95 SamplePump.seek 2000ml,39:40 @14:09:40.54 Cartridge 8 filtering 1530/2000ml at 0.23ml/s with 21.8psi vacuum 20.5m deep (45.0psia) @14:10:23.74 Flow averaged 0.21ml/s over 46 seconds @14:10:23.78 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:10:24.37 Relieved excess vacuum in .6 seconds @14:10:24.40 SamplePump.seek 2000ml,38:54 @14:10:40.54 Cartridge 8 filtering 1542/2000ml at 0.20ml/s with 29.9psi vacuum 14.9m deep (36.7psia) @14:11:07.65 Flow averaged 0.20ml/s over 44 seconds @14:11:07.69 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @14:11:08.27 Relieved excess vacuum in .6 seconds @14:11:08.30 SamplePump.seek 2000ml,38:09 @14:11:29.93 Flow averaged 0.20ml/s over 22 seconds @14:11:29.98 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @14:11:30.94 Relieved excess vacuum in 1 second @14:11:30.97 SamplePump.seek 2000ml,37:47 @14:11:40.54 Cartridge 8 filtering 1554/2000ml at 0.20ml/s with 25.4psi vacuum 14.0m deep (35.4psia) @14:11:48.89 Flow averaged 0.20ml/s over 18 seconds @14:11:48.93 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @14:11:49.52 Relieved excess vacuum in .6 seconds @14:11:49.55 SamplePump.seek 2000ml,37:29 @14:12:40.54 Cartridge 8 filtering 1567/2000ml at 0.23ml/s with 24.4psi vacuum 20.2m deep (44.5psia) @14:12:42.32 Flow averaged 0.21ml/s over 53 seconds @14:12:42.37 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @14:12:42.95 Relieved excess vacuum in .6 seconds @14:12:42.98 SamplePump.seek 2000ml,36:35 @14:13:04.22 Flow averaged 0.20ml/s over 22 seconds @14:13:04.26 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @14:13:04.85 Relieved excess vacuum in .6 seconds @14:13:04.88 SamplePump.seek 2000ml,36:13 @14:13:26.24 Flow averaged 0.20ml/s over 22 seconds @14:13:26.28 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @14:13:26.87 Relieved excess vacuum in .6 seconds @14:13:26.90 SamplePump.seek 2000ml,35:52 @14:13:40.54 Cartridge 8 filtering 1578/2000ml at 0.20ml/s with 29.8psi vacuum 14.8m deep (36.5psia) @14:13:51.21 Flow averaged 0.20ml/s over 25 seconds @14:13:51.26 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:13:51.84 Relieved excess vacuum in .6 seconds @14:13:51.87 SamplePump.seek 2000ml,35:27 @14:14:13.13 Flow averaged 0.20ml/s over 22 seconds @14:14:13.17 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @14:14:13.76 Relieved excess vacuum in .6 seconds @14:14:13.79 SamplePump.seek 2000ml,35:05 @14:14:29.41 Flow averaged 0.20ml/s over 16 seconds @14:14:29.45 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @14:14:30.03 Relieved excess vacuum in .6 seconds @14:14:30.06 SamplePump.seek 2000ml,34:50 @14:14:40.58 Flow averaged 0.20ml/s over 11 seconds @14:14:40.62 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @14:14:40.74 Cartridge 8 filtering 1590/2000ml at 0.20ml/s with 26.3psi vacuum 6.9m deep (24.9psia) @14:14:41.20 Relieved excess vacuum in .7 seconds @14:14:41.23 SamplePump.seek 2000ml,34:39 @14:14:55.04 Flow averaged 0.20ml/s over 14 seconds @14:14:55.08 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:14:55.66 Relieved excess vacuum in .6 seconds @14:14:55.69 SamplePump.seek 2000ml,34:25 @14:15:12.37 Flow averaged 0.20ml/s over 17 seconds @14:15:12.41 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @14:15:13.38 Relieved excess vacuum in 1 second @14:15:13.41 SamplePump.seek 2000ml,34:08 @14:15:39.25 Flow averaged 0.20ml/s over 26 seconds @14:15:39.29 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @14:15:39.87 Relieved excess vacuum in .6 seconds @14:15:39.90 SamplePump.seek 2000ml,33:42 @14:15:40.60 Cartridge 8 filtering 1602/2000ml at 0.20ml/s with 25.0psi vacuum 17.1m deep (40.0psia) @14:15:57.12 Flow averaged 0.20ml/s over 18 seconds @14:15:57.17 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @14:15:57.75 Relieved excess vacuum in .6 seconds @14:15:57.78 SamplePump.seek 2000ml,33:24 @14:16:14.14 Flow averaged 0.20ml/s over 17 seconds @14:16:14.18 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @14:16:14.77 Relieved excess vacuum in .6 seconds @14:16:14.80 SamplePump.seek 2000ml,33:08 @14:16:31.55 Flow averaged 0.20ml/s over 17 seconds @14:16:31.59 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @14:16:32.17 Relieved excess vacuum in .6 seconds @14:16:32.20 SamplePump.seek 2000ml,32:51 @14:16:40.54 Cartridge 8 filtering 1613/2000ml at 0.20ml/s with 26.1psi vacuum 16.1m deep (38.5psia) @14:16:46.47 Flow averaged 0.20ml/s over 15 seconds @14:16:46.51 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:16:47.09 Relieved excess vacuum in .6 seconds @14:16:47.12 SamplePump.seek 2000ml,32:36 @14:17:06.47 Flow averaged 0.20ml/s over 20 seconds @14:17:06.52 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:17:07.10 Relieved excess vacuum in .6 seconds @14:17:07.13 SamplePump.seek 2000ml,32:17 @14:17:19.89 Flow averaged 0.20ml/s over 13 seconds @14:17:19.93 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @14:17:20.51 Relieved excess vacuum in .6 seconds @14:17:20.54 SamplePump.seek 2000ml,32:04 @14:17:37.41 Flow averaged 0.20ml/s over 17 seconds @14:17:37.45 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @14:17:38.03 Relieved excess vacuum in .6 seconds @14:17:38.06 SamplePump.seek 2000ml,31:47 @14:17:40.54 Cartridge 8 filtering 1625/2000ml at 0.21ml/s with 16.7psi vacuum 19.4m deep (43.3psia) @14:17:52.86 Flow averaged 0.20ml/s over 15 seconds @14:17:52.91 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @14:17:53.49 Relieved excess vacuum in .6 seconds @14:17:53.52 SamplePump.seek 2000ml,31:32 @14:18:02.74 Flow averaged 0.20ml/s over 10 seconds @14:18:02.76 Intake.close @14:18:02.83 Exhaust.close @14:18:03.04 Toroid.in :hold @14:18:03.11 Toroid.seek :bypass @14:18:04.77 Toroid.in :default @14:18:04.85 Toroid.seek :clear @14:18:06.84 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @14:18:06.86 Pressure.stop @14:18:07.07 Sampled 1629.4ml @14:18:09.33 -> Cmd.startProcessing @14:18:09.77 Plunge.seek :reagent @14:18:10.67 Sample loop closed. Ready to Deliver Reagents @14:18:10.69 Archive.seek :sealed @14:18:14.35 Archive.seek :evac @14:18:28.36 delay 1:00 @14:19:28.38 Archive.seek :clear @14:19:45.55 Sample preserved. Puck Full. @14:19:46.69 -> Cmd.stop @14:19:46.79 Carousel.in :default @14:19:46.91 Carousel.home.seek 8 @14:19:47.21 Plunge.seek :locked @14:19:48.24 Air.in :unlocking @14:19:48.37 Air.seek :clear @14:19:48.42 Lysis1.in :unlocking @14:19:48.57 Lysis1.seek :clear @14:19:49.90 Gate.power :motor,:OFF @14:19:49.92 Gate.power :core,:OFF @14:19:49.94 Gate.power :analytic1,:OFF @14:19:49.96 Gate.power :analytic2,:OFF @14:19:49.99 Gate.power :analytic3,:OFF @14:19:50.00 Gate.power :main,:OFF @14:19:50.03 Safely stopped and ready to power off ##-- file closed 2023-08-13T14:28:02.804Z ##-- file opened 2023-08-13T14:28:02.807Z @14:28:03.01 -> showStatus @14:28:05.03 -> Cmd.loadCartridge -1 @14:28:05.11 Gate.power :main,:ON,limit to 5000mA @14:28:05.12 Gate.power :analytic1,:ON,limit to 5000mA @14:28:05.15 Gate.power :analytic2,:ON,limit to 5000mA @14:28:05.17 Gate.power :analytic3,:ON,limit to 5000mA @14:28:05.21 Powering core bus @14:28:07.92 Archive.configure :default @14:28:08.01 Air.configure :default @14:28:08.09 Lysis1.configure :default @14:28:08.15 Lysis2.configure :default @14:28:08.25 Plunge.configure :default @14:28:08.34 SamplePump.configure :default @14:28:08.43 Toroid.configure :default @14:28:08.52 Carousel.configure :default @14:28:08.62 Pressure.configure :default @14:28:08.71 ExtraPump.configure :default @14:28:08.77 All elf controllers running firmware version 4.83 @14:28:08.80 Gate.power :motor,:ON,limit to 5000mA @14:28:08.93 Archive.home.jog 0 @14:28:09.40 Carousel.home.jog 0 @14:28:09.48 Toroid.home.jog 0 @14:28:09.52 Lysis1.home.jog 0 @14:28:09.54 Air.home.jog 0 @14:28:09.58 Plunge.home.jog 0 @14:28:09.61 Lysis2.home.jog 0 @14:28:10.12 Archive.in :homing @14:28:10.40 Archive.jog 1341 @14:28:10.44 Plunge.in :homing @14:28:10.47 Lysis2.in :homing @14:28:10.52 Lysis1.in :homing @14:28:10.55 Air.in :homing @14:28:10.59 Toroid.in :homing @14:28:10.82 Plunge.jog 771 @14:28:10.86 Lysis2.jog 1366 @14:28:10.89 Lysis1.jog 1353 @14:28:10.93 Toroid.jog 592 @14:28:10.98 Air.jog 170 @14:28:11.55 Air.setRawPosition! 50 @14:28:11.61 Air.seek :home @14:28:11.78 Archive.setRawPosition! 50 @14:28:11.85 Plunge.setRawPosition! 50 @14:28:11.87 Archive.seek :home @14:28:11.99 Plunge.seek :home @14:28:12.07 Air.in :default @14:28:12.17 Lysis1.setRawPosition! 50 @14:28:12.26 Lysis2.setRawPosition! 50 @14:28:12.28 Lysis1.seek :home @14:28:12.32 Archive.in :default @14:28:12.42 Lysis2.seek :home @14:28:12.56 Plunge.in :default @14:28:12.67 Lysis1.in :default @14:28:12.75 Lysis2.in :default @14:28:13.12 Toroid.setRawPosition! 0 @14:28:13.17 Toroid.seek :home @14:28:13.25 Toroid.in :default @14:28:13.33 Toroid.seek :clear @14:28:14.96 Carousel.in :default @14:28:15.08 Carousel.home.seek 8 @14:28:15.34 Selecting Cartridge 7 @14:28:15.56 Carousel.seek 7 @14:28:16.05 Lysis1.in :fast @14:28:16.12 Lysis1.seek :locked @14:28:18.71 Plunge.seek :locked @14:28:18.85 Air.in :fast @14:28:18.92 Air.seek :locked @14:28:20.47 Carousel.reconfigure :locked @14:28:21.13 Mounted archive Cartridge @14:28:36.95 -> Cmd.startFiltering @14:28:37.22 Preparing to filter cartridge 7 @14:28:37.56 Priming sample loop w/100ml, bypass w/10ml @14:28:37.58 SamplePump.setPosition! 0ml @14:28:37.63 Bypass.open @14:28:39.11 Intake.open @14:28:39.85 Sea 16.1m deep (38.5psia) @14:28:39.87 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @14:28:42.45 Vacuum tare is 51% of full scale @14:28:42.60 Intake.close @14:28:42.72 Bypass.close @14:28:43.41 Verifying toroid holds at least 0.6..0.85 of 38.5psia @14:28:43.43 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @14:28:48.03 Bypass.open @14:28:48.74 Intake.open @14:28:50.19 Pressure.in :default @14:28:50.26 Pressure.hold @14:28:50.45 SamplePump.in :prime @14:28:50.53 SamplePump.seek 10ml,59 seconds @14:29:01.39 Pressure.stop @14:29:01.45 SamplePump.setPosition! 0ml @14:29:01.49 Exhaust.open @14:29:02.96 Bypass.close @14:29:04.44 Pressure.in :default @14:29:04.51 Pressure.hold @14:29:04.63 Sea 16.1m deep (38.4psia) @14:29:04.78 SamplePump.in :prime @14:29:04.86 SamplePump.seek 100ml,5:16 @14:30:53.37 Pressure.stop @14:30:53.47 Bypass.open @14:30:54.15 Intake.close @14:30:54.89 Toroid.in :hold @14:30:54.96 Toroid.seek :crack @14:30:56.69 Toroid.seek :cartridge @14:30:57.67 Toroid.in :default @14:30:57.79 Toroid.seek :clear @14:30:59.85 Exhaust.close @14:30:59.90 Bypass.close @14:31:00.60 Verifying cartridge holds at least 0.65..0.85 of 38.4psia @14:31:00.62 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @14:31:05.25 Sampling 2000.0ml @14:31:05.27 SamplePump.setPosition! 0ml @14:31:05.34 Exhaust.open @14:31:06.00 Intake.open @14:31:06.83 Pressure.in :default @14:31:06.90 Pressure.hold @14:31:07.02 Sea 16.1m deep (38.4psia) @14:31:07.04 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @14:31:07.20 SamplePump.in :sample @14:31:07.28 SamplePump.seek 2000ml,2:47:06 @14:31:09.87 Cartridge 7 filtering 1/2000ml at 0.57ml/s with 23.8psi vacuum 16.7m deep (39.4psia) @14:32:09.88 Cartridge 7 filtering 33/2000ml at 0.53ml/s with 23.4psi vacuum 17.7m deep (40.8psia) @14:33:09.88 Cartridge 7 filtering 65/2000ml at 0.55ml/s with 25.2psi vacuum 17.4m deep (40.4psia) @14:34:09.88 Cartridge 7 filtering 96/2000ml at 0.50ml/s with 25.9psi vacuum 15.8m deep (38.0psia) @14:35:09.88 Cartridge 7 filtering 126/2000ml at 0.49ml/s with 26.2psi vacuum 15.9m deep (38.2psia) @14:36:09.88 Cartridge 7 filtering 156/2000ml at 0.51ml/s with 20.5psi vacuum 20.4m deep (44.9psia) @14:37:09.88 Cartridge 7 filtering 185/2000ml at 0.48ml/s with 19.7psi vacuum 18.3m deep (41.7psia) @14:38:09.88 Cartridge 7 filtering 213/2000ml at 0.46ml/s with 26.2psi vacuum 15.5m deep (37.6psia) @14:39:09.87 Cartridge 7 filtering 241/2000ml at 0.46ml/s with 18.9psi vacuum 18.8m deep (42.5psia) @14:40:09.88 Cartridge 7 filtering 268/2000ml at 0.43ml/s with 24.6psi vacuum 16.5m deep (39.1psia) @14:41:09.88 Cartridge 7 filtering 295/2000ml at 0.44ml/s with 27.5psi vacuum 15.3m deep (37.4psia) @14:42:09.88 Cartridge 7 filtering 321/2000ml at 0.44ml/s with 27.7psi vacuum 16.0m deep (38.3psia) @14:43:09.88 Cartridge 7 filtering 346/2000ml at 0.41ml/s with 25.0psi vacuum 16.3m deep (38.8psia) @14:44:09.88 Cartridge 7 filtering 371/2000ml at 0.40ml/s with 25.9psi vacuum 16.1m deep (38.4psia) @14:45:10.22 Cartridge 7 filtering 396/2000ml at 0.41ml/s with 17.9psi vacuum 20.2m deep (44.5psia) @14:46:09.88 Cartridge 7 filtering 420/2000ml at 0.38ml/s with 23.9psi vacuum 11.0m deep (31.0psia) @14:47:09.88 Cartridge 7 filtering 443/2000ml at 0.39ml/s with 27.0psi vacuum 15.3m deep (37.4psia) @14:48:09.88 Cartridge 7 filtering 467/2000ml at 0.37ml/s with 24.6psi vacuum 14.4m deep (35.9psia) @14:49:09.88 Cartridge 7 filtering 490/2000ml at 0.39ml/s with 22.9psi vacuum 17.0m deep (39.8psia) @14:50:09.88 Cartridge 7 filtering 512/2000ml at 0.35ml/s with 24.1psi vacuum 11.1m deep (31.1psia) @14:51:09.88 Cartridge 7 filtering 534/2000ml at 0.36ml/s with 21.0psi vacuum 19.3m deep (43.3psia) @14:52:09.88 Cartridge 7 filtering 556/2000ml at 0.38ml/s with 23.7psi vacuum 18.5m deep (42.0psia) @14:53:09.88 Cartridge 7 filtering 578/2000ml at 0.34ml/s with 25.8psi vacuum 15.4m deep (37.4psia) @14:54:09.88 Cartridge 7 filtering 599/2000ml at 0.33ml/s with 26.2psi vacuum 14.6m deep (36.3psia) @14:55:09.88 Cartridge 7 filtering 619/2000ml at 0.33ml/s with 23.1psi vacuum 11.3m deep (31.4psia) @14:56:09.88 Cartridge 7 filtering 640/2000ml at 0.36ml/s with 22.4psi vacuum 17.9m deep (41.1psia) @14:57:09.88 Cartridge 7 filtering 660/2000ml at 0.34ml/s with 26.8psi vacuum 16.7m deep (39.3psia) @14:58:09.88 Cartridge 7 filtering 680/2000ml at 0.34ml/s with 28.6psi vacuum 14.7m deep (36.5psia) @14:59:09.88 Cartridge 7 filtering 699/2000ml at 0.31ml/s with 26.0psi vacuum 15.1m deep (37.0psia) @15:00:09.88 Cartridge 7 filtering 719/2000ml at 0.33ml/s with 27.8psi vacuum 15.0m deep (36.9psia) @15:01:09.88 Cartridge 7 filtering 738/2000ml at 0.30ml/s with 23.2psi vacuum 17.5m deep (40.6psia) @15:02:09.88 Cartridge 7 filtering 757/2000ml at 0.30ml/s with 26.0psi vacuum 15.7m deep (37.8psia) @15:03:09.88 Cartridge 7 filtering 775/2000ml at 0.30ml/s with 25.9psi vacuum 16.2m deep (38.6psia) @15:04:09.88 Cartridge 7 filtering 793/2000ml at 0.30ml/s with 26.4psi vacuum 16.2m deep (38.6psia) @15:05:09.88 Cartridge 7 filtering 812/2000ml at 0.31ml/s with 27.6psi vacuum 15.7m deep (37.9psia) @15:06:09.88 Cartridge 7 filtering 829/2000ml at 0.29ml/s with 22.2psi vacuum 13.2m deep (34.2psia) @15:07:09.88 Cartridge 7 filtering 847/2000ml at 0.29ml/s with 16.7psi vacuum 20.1m deep (44.5psia) @15:08:09.88 Cartridge 7 filtering 865/2000ml at 0.31ml/s with 25.6psi vacuum 18.2m deep (41.6psia) @15:09:09.88 Cartridge 7 filtering 882/2000ml at 0.30ml/s with 18.1psi vacuum 21.3m deep (46.2psia) @15:10:09.88 Cartridge 7 filtering 899/2000ml at 0.30ml/s with 25.3psi vacuum 16.8m deep (39.5psia) @15:11:09.88 Cartridge 7 filtering 916/2000ml at 0.27ml/s with 25.5psi vacuum 16.5m deep (39.1psia) @15:12:09.88 Cartridge 7 filtering 932/2000ml at 0.27ml/s with 26.0psi vacuum 10.1m deep (29.6psia) @15:13:09.88 Cartridge 7 filtering 949/2000ml at 0.28ml/s with 28.2psi vacuum 15.5m deep (37.5psia) @15:14:09.88 Cartridge 7 filtering 965/2000ml at 0.26ml/s with 21.3psi vacuum 13.2m deep (34.2psia) @15:15:09.88 Cartridge 7 filtering 981/2000ml at 0.26ml/s with 24.4psi vacuum 16.8m deep (39.5psia) @15:16:09.88 Cartridge 7 filtering 997/2000ml at 0.26ml/s with 26.7psi vacuum 16.0m deep (38.3psia) @15:17:09.94 Cartridge 7 filtering 1013/2000ml at 0.26ml/s with 17.2psi vacuum 19.8m deep (43.9psia) @15:18:09.88 Cartridge 7 filtering 1028/2000ml at 0.27ml/s with 24.4psi vacuum 17.8m deep (41.0psia) @15:19:09.88 Cartridge 7 filtering 1043/2000ml at 0.24ml/s with 25.4psi vacuum 15.2m deep (37.2psia) @15:20:09.88 Cartridge 7 filtering 1059/2000ml at 0.24ml/s with 24.4psi vacuum 15.9m deep (38.2psia) @15:21:10.25 Cartridge 7 filtering 1074/2000ml at 0.24ml/s with 24.6psi vacuum 17.6m deep (40.8psia) @15:22:09.88 Cartridge 7 filtering 1088/2000ml at 0.23ml/s with 24.7psi vacuum 15.9m deep (38.2psia) @15:23:09.88 Cartridge 7 filtering 1103/2000ml at 0.25ml/s with 15.8psi vacuum 21.6m deep (46.6psia) @15:24:09.88 Cartridge 7 filtering 1118/2000ml at 0.25ml/s with 16.4psi vacuum 21.2m deep (46.0psia) @15:25:09.88 Cartridge 7 filtering 1132/2000ml at 0.23ml/s with 24.4psi vacuum 16.5m deep (39.1psia) @15:26:09.88 Cartridge 7 filtering 1146/2000ml at 0.23ml/s with 25.3psi vacuum 15.9m deep (38.1psia) @15:27:09.88 Cartridge 7 filtering 1160/2000ml at 0.26ml/s with 26.6psi vacuum 15.7m deep (37.9psia) @15:28:09.88 Cartridge 7 filtering 1174/2000ml at 0.25ml/s with 24.9psi vacuum 17.0m deep (39.8psia) @15:29:09.88 Cartridge 7 filtering 1188/2000ml at 0.23ml/s with 24.1psi vacuum 18.3m deep (41.7psia) @15:30:09.88 Cartridge 7 filtering 1202/2000ml at 0.21ml/s with 23.6psi vacuum 16.8m deep (39.5psia) @15:31:09.88 Cartridge 7 filtering 1215/2000ml at 0.22ml/s with 20.2psi vacuum 19.7m deep (43.7psia) @15:32:09.88 Cartridge 7 filtering 1229/2000ml at 0.21ml/s with 23.5psi vacuum 16.2m deep (38.6psia) @15:33:09.88 Cartridge 7 filtering 1242/2000ml at 0.20ml/s with 22.7psi vacuum 16.9m deep (39.7psia) @15:34:09.88 Cartridge 7 filtering 1255/2000ml at 0.24ml/s with 20.9psi vacuum 20.6m deep (45.2psia) @15:35:09.88 Cartridge 7 filtering 1268/2000ml at 0.21ml/s with 23.8psi vacuum 15.0m deep (36.8psia) @15:36:09.88 Cartridge 7 filtering 1281/2000ml at 0.20ml/s with 26.3psi vacuum 15.4m deep (37.5psia) @15:37:09.88 Cartridge 7 filtering 1294/2000ml at 0.20ml/s with 24.5psi vacuum 15.4m deep (37.5psia) @15:38:09.88 Cartridge 7 filtering 1307/2000ml at 0.24ml/s with 26.4psi vacuum 16.3m deep (38.8psia) @15:39:09.88 Cartridge 7 filtering 1319/2000ml at 0.24ml/s with 25.6psi vacuum 17.4m deep (40.5psia) @15:40:09.88 Cartridge 7 filtering 1332/2000ml at 0.21ml/s with 24.7psi vacuum 17.0m deep (39.8psia) @15:41:09.88 Cartridge 7 filtering 1345/2000ml at 0.20ml/s with 25.5psi vacuum 16.3m deep (38.8psia) @15:42:09.88 Cartridge 7 filtering 1357/2000ml at 0.20ml/s with 25.0psi vacuum 15.9m deep (38.2psia) @15:43:09.88 Cartridge 7 filtering 1370/2000ml at 0.20ml/s with 26.2psi vacuum 16.1m deep (38.5psia) @15:44:09.88 Cartridge 7 filtering 1382/2000ml at 0.20ml/s with 27.3psi vacuum 15.3m deep (37.3psia) @15:45:09.93 Cartridge 7 filtering 1394/2000ml at 0.20ml/s with 25.6psi vacuum 14.2m deep (35.6psia) @15:46:07.09 Flow averaged 0.31ml/s over 1:15:00 @15:46:07.13 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @15:46:07.71 Relieved excess vacuum in .6 seconds @15:46:07.74 SamplePump.seek 2000ml,49:58 @15:46:09.87 Cartridge 7 filtering 1407/2000ml at 0.20ml/s with 25.0psi vacuum 12.1m deep (32.6psia) @15:47:09.88 Cartridge 7 filtering 1419/2000ml at 0.20ml/s with 24.9psi vacuum 16.4m deep (39.0psia) @15:48:09.88 Cartridge 7 filtering 1431/2000ml at 0.20ml/s with 26.4psi vacuum 16.1m deep (38.4psia) @15:48:47.69 Flow averaged 0.21ml/s over 2:40 @15:48:47.73 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @15:48:48.31 Relieved excess vacuum in .6 seconds @15:48:48.34 SamplePump.seek 2000ml,47:13 @15:49:09.87 Cartridge 7 filtering 1444/2000ml at 0.20ml/s with 27.5psi vacuum 16.3m deep (38.7psia) @15:50:09.87 Cartridge 7 filtering 1456/2000ml at 0.20ml/s with 25.8psi vacuum 16.8m deep (39.6psia) @15:50:40.20 Flow averaged 0.21ml/s over 1:52 @15:50:40.24 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @15:50:40.83 Relieved excess vacuum in .6 seconds @15:50:40.86 SamplePump.seek 2000ml,45:18 @15:51:09.88 Cartridge 7 filtering 1468/2000ml at 0.23ml/s with 23.2psi vacuum 19.5m deep (43.5psia) @15:52:09.88 Cartridge 7 filtering 1481/2000ml at 0.20ml/s with 25.1psi vacuum 17.3m deep (40.2psia) @15:52:15.44 Flow averaged 0.21ml/s over 1:35 @15:52:15.48 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @15:52:16.07 Relieved excess vacuum in .6 seconds @15:52:16.10 SamplePump.seek 2000ml,43:41 @15:53:09.92 Cartridge 7 filtering 1493/2000ml at 0.20ml/s with 24.1psi vacuum 15.7m deep (37.9psia) @15:53:25.02 Flow averaged 0.21ml/s over 1:09 @15:53:25.07 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @15:53:25.67 Relieved excess vacuum in .7 seconds @15:53:25.70 SamplePump.seek 2000ml,42:30 @15:54:09.87 Cartridge 7 filtering 1505/2000ml at 0.23ml/s with 22.1psi vacuum 19.6m deep (43.7psia) @15:54:16.95 Flow averaged 0.21ml/s over 52 seconds @15:54:16.99 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @15:54:17.62 Relieved excess vacuum in .7 seconds @15:54:17.65 SamplePump.seek 2000ml,41:37 @15:55:07.39 Flow averaged 0.21ml/s over 50 seconds @15:55:07.43 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @15:55:08.03 Relieved excess vacuum in .6 seconds @15:55:08.06 SamplePump.seek 2000ml,40:46 @15:55:09.87 Cartridge 7 filtering 1517/2000ml at 0.20ml/s with 27.2psi vacuum 16.1m deep (38.5psia) @15:55:23.34 Flow averaged 0.20ml/s over 16 seconds @15:55:23.38 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @15:55:23.97 Relieved excess vacuum in .6 seconds @15:55:24.00 SamplePump.seek 2000ml,40:31 @15:56:09.87 Cartridge 7 filtering 1529/2000ml at 0.20ml/s with 26.4psi vacuum 16.4m deep (38.9psia) @15:57:09.88 Cartridge 7 filtering 1541/2000ml at 0.22ml/s with 16.2psi vacuum 21.5m deep (46.4psia) @15:57:13.73 Flow averaged 0.21ml/s over 1:50 @15:57:13.77 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @15:57:14.36 Relieved excess vacuum in .6 seconds @15:57:14.39 SamplePump.seek 2000ml,38:38 @15:58:08.65 Flow averaged 0.21ml/s over 55 seconds @15:58:08.69 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @15:58:09.28 Relieved excess vacuum in .6 seconds @15:58:09.31 SamplePump.seek 2000ml,37:42 @15:58:09.92 Cartridge 7 filtering 1553/2000ml at 0.18ml/s with 17.1psi vacuum 21.0m deep (45.8psia) @15:58:30.37 Flow averaged 0.20ml/s over 22 seconds @15:58:30.41 Waiting up to 11 seconds for vacuum to reduce from 27.4 to 18.0psi @15:58:31.00 Relieved excess vacuum in .6 seconds @15:58:31.03 SamplePump.seek 2000ml,37:21 @15:59:10.24 Cartridge 7 filtering 1566/2000ml at 0.20ml/s with 26.4psi vacuum 16.5m deep (39.1psia) @15:59:12.00 Flow averaged 0.20ml/s over 41 seconds @15:59:12.05 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @15:59:12.64 Relieved excess vacuum in .6 seconds @15:59:12.67 SamplePump.seek 2000ml,36:39 @15:59:38.47 Flow averaged 0.20ml/s over 26 seconds @15:59:38.51 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @15:59:39.10 Relieved excess vacuum in .6 seconds @15:59:39.13 SamplePump.seek 2000ml,36:13 @16:00:05.85 Flow averaged 0.20ml/s over 27 seconds @16:00:05.90 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @16:00:06.49 Relieved excess vacuum in .6 seconds @16:00:06.52 SamplePump.seek 2000ml,35:45 @16:00:09.87 Cartridge 7 filtering 1577/2000ml at 0.20ml/s with 26.2psi vacuum 16.7m deep (39.3psia) @16:00:34.37 Flow averaged 0.20ml/s over 28 seconds @16:00:34.41 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @16:00:35.00 Relieved excess vacuum in .6 seconds @16:00:35.03 SamplePump.seek 2000ml,35:17 @16:00:54.84 Flow averaged 0.20ml/s over 20 seconds @16:00:54.88 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @16:00:55.47 Relieved excess vacuum in .6 seconds @16:00:55.50 SamplePump.seek 2000ml,34:57 @16:01:09.87 Cartridge 7 filtering 1589/2000ml at 0.20ml/s with 26.4psi vacuum 16.5m deep (39.0psia) @16:01:22.64 Flow averaged 0.20ml/s over 28 seconds @16:01:22.68 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @16:01:23.27 Relieved excess vacuum in .6 seconds @16:01:23.30 SamplePump.seek 2000ml,34:29 @16:01:44.32 Flow averaged 0.20ml/s over 22 seconds @16:01:44.36 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @16:01:44.95 Relieved excess vacuum in .6 seconds @16:01:44.98 SamplePump.seek 2000ml,34:08 @16:01:57.28 Flow averaged 0.20ml/s over 13 seconds @16:01:57.32 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @16:01:57.91 Relieved excess vacuum in .6 seconds @16:01:57.94 SamplePump.seek 2000ml,33:56 @16:02:09.87 Cartridge 7 filtering 1601/2000ml at 0.20ml/s with 23.0psi vacuum 12.5m deep (33.2psia) @16:02:19.26 Flow averaged 0.20ml/s over 22 seconds @16:02:19.30 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @16:02:19.88 Relieved excess vacuum in .6 seconds @16:02:19.91 SamplePump.seek 2000ml,33:34 @16:02:37.21 Flow averaged 0.20ml/s over 18 seconds @16:02:37.26 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @16:02:37.84 Relieved excess vacuum in .6 seconds @16:02:37.87 SamplePump.seek 2000ml,33:16 @16:03:00.70 Flow averaged 0.20ml/s over 23 seconds @16:03:00.75 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @16:03:01.70 Relieved excess vacuum in 1 second @16:03:01.73 SamplePump.seek 2000ml,32:53 @16:03:09.88 Cartridge 7 filtering 1613/2000ml at 0.23ml/s with 27.0psi vacuum 17.1m deep (40.0psia) @16:03:24.11 Flow averaged 0.20ml/s over 23 seconds @16:03:24.16 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @16:03:24.75 Relieved excess vacuum in .6 seconds @16:03:24.78 SamplePump.seek 2000ml,32:31 @16:03:37.13 Flow averaged 0.20ml/s over 13 seconds @16:03:37.17 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @16:03:37.76 Relieved excess vacuum in .6 seconds @16:03:37.79 SamplePump.seek 2000ml,32:18 @16:03:51.63 Flow averaged 0.20ml/s over 14 seconds @16:03:51.67 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @16:03:52.27 Relieved excess vacuum in .6 seconds @16:03:52.30 SamplePump.seek 2000ml,32:04 @16:04:09.88 Cartridge 7 filtering 1625/2000ml at 0.23ml/s with 20.0psi vacuum 21.3m deep (46.2psia) @16:04:17.24 Flow averaged 0.20ml/s over 25 seconds @16:04:17.29 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @16:04:17.88 Relieved excess vacuum in .7 seconds @16:04:17.91 SamplePump.seek 2000ml,31:39 @16:04:23.72 Flow estimate reduced to 0.16ml/s @16:04:23.73 Intake.close @16:04:23.79 Exhaust.close @16:04:24.02 Toroid.in :hold @16:04:24.10 Toroid.seek :bypass @16:04:25.75 Toroid.in :default @16:04:25.83 Toroid.seek :clear @16:04:27.47 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @16:04:27.50 Pressure.stop @16:04:27.69 Sampled 1627.2ml @16:04:29.70 -> Cmd.startProcessing @16:04:30.14 Plunge.seek :reagent @16:04:31.03 Sample loop closed. Ready to Deliver Reagents @16:04:31.05 Archive.seek :sealed @16:04:34.71 Archive.seek :evac @16:04:48.73 delay 1:00 @16:05:48.75 Archive.seek :clear @16:06:05.94 Sample preserved. Puck Full. @16:06:07.07 -> Cmd.stop @16:06:07.17 Carousel.in :default @16:06:07.28 Carousel.home.seek 7 @16:06:07.58 Plunge.seek :locked @16:06:08.62 Air.in :unlocking @16:06:08.76 Air.seek :clear @16:06:08.81 Lysis1.in :unlocking @16:06:09.34 Lysis1.seek :clear @16:06:10.62 Gate.power :motor,:OFF @16:06:10.64 Gate.power :core,:OFF @16:06:10.66 Gate.power :analytic1,:OFF @16:06:10.68 Gate.power :analytic2,:OFF @16:06:10.70 Gate.power :analytic3,:OFF @16:06:10.78 Gate.power :main,:OFF @16:06:10.80 Safely stopped and ready to power off ##-- file closed 2023-08-13T16:35:40.942Z ##-- file opened 2023-08-13T16:35:40.944Z @16:35:41.27 -> showStatus @16:35:43.29 -> Cmd.loadCartridge -1 @16:35:43.36 Gate.power :main,:ON,limit to 5000mA @16:35:43.37 Gate.power :analytic1,:ON,limit to 5000mA @16:35:43.39 Gate.power :analytic2,:ON,limit to 5000mA @16:35:43.41 Gate.power :analytic3,:ON,limit to 5000mA @16:35:43.47 Powering core bus @16:35:46.17 Archive.configure :default @16:35:46.26 Air.configure :default @16:35:46.33 Lysis1.configure :default @16:35:46.40 Lysis2.configure :default @16:35:46.49 Plunge.configure :default @16:35:46.58 SamplePump.configure :default @16:35:46.67 Toroid.configure :default @16:35:46.76 Carousel.configure :default @16:35:46.86 Pressure.configure :default @16:35:46.95 ExtraPump.configure :default @16:35:47.01 All elf controllers running firmware version 4.83 @16:35:47.04 Gate.power :motor,:ON,limit to 5000mA @16:35:47.23 Archive.home.jog 0 @16:35:47.68 Toroid.home.jog 0 @16:35:47.71 Plunge.home.jog 0 @16:35:47.73 Lysis1.home.jog 0 @16:35:47.76 Air.home.jog 0 @16:35:47.79 Carousel.home.jog 0 @16:35:47.82 Lysis2.home.jog 0 @16:35:48.37 Archive.in :homing @16:35:48.60 Archive.jog 1351 @16:35:48.64 Plunge.in :homing @16:35:48.67 Lysis2.in :homing @16:35:48.72 Lysis1.in :homing @16:35:48.76 Air.in :homing @16:35:48.80 Toroid.in :homing @16:35:49.00 Plunge.jog 772 @16:35:49.05 Lysis2.jog 1365 @16:35:49.08 Lysis1.jog 1363 @16:35:49.14 Toroid.jog 595 @16:35:49.17 Air.jog 165 @16:35:49.71 Air.setRawPosition! 50 @16:35:49.77 Air.seek :home @16:35:49.97 Plunge.setRawPosition! 50 @16:35:49.99 Archive.setRawPosition! 50 @16:35:50.09 Plunge.seek :home @16:35:50.11 Archive.seek :home @16:35:50.27 Air.in :default @16:35:50.36 Lysis2.setRawPosition! 50 @16:35:50.42 Lysis2.seek :home @16:35:50.52 Plunge.in :default @16:35:50.55 Archive.in :default @16:35:50.58 Lysis1.setRawPosition! 50 @16:35:50.74 Lysis1.seek :home @16:35:50.78 Lysis2.in :default @16:35:51.06 Lysis1.in :default @16:35:51.27 Toroid.setRawPosition! 0 @16:35:51.33 Toroid.seek :home @16:35:51.41 Toroid.in :default @16:35:51.49 Toroid.seek :clear @16:35:53.10 Carousel.in :default @16:35:53.23 Carousel.home.seek 7 @16:35:53.51 Selecting Cartridge 6 @16:35:53.73 Carousel.seek 6 @16:35:54.23 Lysis1.in :fast @16:35:54.29 Lysis1.seek :locked @16:35:56.94 Plunge.seek :locked @16:35:57.09 Air.in :fast @16:35:57.16 Air.seek :locked @16:35:58.70 Carousel.reconfigure :locked @16:35:59.37 Mounted archive Cartridge @16:36:15.20 -> Cmd.startFiltering @16:36:15.46 Preparing to filter cartridge 6 @16:36:15.80 Priming sample loop w/100ml, bypass w/10ml @16:36:15.82 SamplePump.setPosition! 0ml @16:36:15.87 Bypass.open @16:36:17.32 Intake.open @16:36:18.07 Sea 17.2m deep (40.1psia) @16:36:18.09 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @16:36:20.68 Vacuum tare is 51% of full scale @16:36:20.87 Intake.close @16:36:20.92 Bypass.close @16:36:21.63 Verifying toroid holds at least 0.6..0.85 of 40.1psia @16:36:21.65 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @16:36:26.23 Bypass.open @16:36:26.93 Intake.open @16:36:28.35 Pressure.in :default @16:36:28.42 Pressure.hold @16:36:28.63 SamplePump.in :prime @16:36:28.71 SamplePump.seek 10ml,59 seconds @16:36:39.56 Pressure.stop @16:36:39.62 SamplePump.setPosition! 0ml @16:36:39.68 Exhaust.open @16:36:41.17 Bypass.close @16:36:42.65 Pressure.in :default @16:36:42.72 Pressure.hold @16:36:42.84 Sea 16.8m deep (39.5psia) @16:36:42.99 SamplePump.in :prime @16:36:43.08 SamplePump.seek 100ml,5:16 @16:38:29.86 Pressure.stop @16:38:30.31 Bypass.open @16:38:31.00 Intake.close @16:38:31.72 Toroid.in :hold @16:38:31.79 Toroid.seek :crack @16:38:33.53 Toroid.seek :cartridge @16:38:34.50 Toroid.in :default @16:38:34.57 Toroid.seek :clear @16:38:36.67 Exhaust.close @16:38:36.71 Bypass.close @16:38:37.43 Verifying cartridge holds at least 0.65..0.85 of 39.4psia @16:38:37.45 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @16:38:42.09 Sampling 2000.0ml @16:38:42.11 SamplePump.setPosition! 0ml @16:38:42.18 Exhaust.open @16:38:42.84 Intake.open @16:38:43.69 Pressure.in :default @16:38:43.76 Pressure.hold @16:38:43.89 Sea 16.8m deep (39.6psia) @16:38:43.90 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @16:38:44.07 SamplePump.in :sample @16:38:44.14 SamplePump.seek 2000ml,2:47:06 @16:38:46.73 Cartridge 6 filtering 1/2000ml at 0.59ml/s with 25.1psi vacuum 15.7m deep (37.8psia) @16:39:46.74 Cartridge 6 filtering 35/2000ml at 0.56ml/s with 27.2psi vacuum 14.8m deep (36.6psia) @16:40:46.74 Cartridge 6 filtering 68/2000ml at 0.55ml/s with 23.8psi vacuum 16.8m deep (39.5psia) @16:41:46.74 Cartridge 6 filtering 100/2000ml at 0.54ml/s with 27.0psi vacuum 16.9m deep (39.7psia) @16:42:46.74 Cartridge 6 filtering 131/2000ml at 0.50ml/s with 24.5psi vacuum 18.2m deep (41.6psia) @16:43:46.74 Cartridge 6 filtering 161/2000ml at 0.50ml/s with 22.4psi vacuum 18.5m deep (42.0psia) @16:44:46.74 Cartridge 6 filtering 190/2000ml at 0.46ml/s with 25.6psi vacuum 11.0m deep (31.0psia) @16:45:46.73 Cartridge 6 filtering 219/2000ml at 0.47ml/s with 18.6psi vacuum 19.4m deep (43.4psia) @16:46:46.73 Cartridge 6 filtering 246/2000ml at 0.45ml/s with 14.9psi vacuum 21.9m deep (47.0psia) @16:47:46.73 Cartridge 6 filtering 274/2000ml at 0.45ml/s with 26.5psi vacuum 16.6m deep (39.2psia) @16:48:46.74 Cartridge 6 filtering 300/2000ml at 0.42ml/s with 24.7psi vacuum 10.9m deep (30.8psia) @16:49:46.74 Cartridge 6 filtering 326/2000ml at 0.43ml/s with 17.3psi vacuum 20.4m deep (44.8psia) @16:50:46.74 Cartridge 6 filtering 351/2000ml at 0.42ml/s with 27.5psi vacuum 12.1m deep (32.6psia) @16:51:46.74 Cartridge 6 filtering 375/2000ml at 0.40ml/s with 20.1psi vacuum 20.9m deep (45.5psia) @16:52:46.73 Cartridge 6 filtering 399/2000ml at 0.39ml/s with 25.9psi vacuum 9.9m deep (29.3psia) @16:53:46.73 Cartridge 6 filtering 423/2000ml at 0.40ml/s with 27.6psi vacuum 15.6m deep (37.8psia) @16:54:46.74 Cartridge 6 filtering 446/2000ml at 0.39ml/s with 18.7psi vacuum 19.7m deep (43.8psia) @16:55:46.74 Cartridge 6 filtering 469/2000ml at 0.39ml/s with 22.6psi vacuum 18.7m deep (42.3psia) @16:56:46.74 Cartridge 6 filtering 491/2000ml at 0.36ml/s with 25.7psi vacuum 17.3m deep (40.3psia) @16:57:46.73 Cartridge 6 filtering 512/2000ml at 0.34ml/s with 22.7psi vacuum 11.1m deep (31.0psia) @16:58:46.74 Cartridge 6 filtering 534/2000ml at 0.34ml/s with 25.0psi vacuum 11.8m deep (32.1psia) @16:59:46.74 Cartridge 6 filtering 555/2000ml at 0.34ml/s with 25.8psi vacuum 15.5m deep (37.5psia) @17:00:46.74 Cartridge 6 filtering 575/2000ml at 0.34ml/s with 25.7psi vacuum 14.8m deep (36.5psia) @17:01:46.73 Cartridge 6 filtering 596/2000ml at 0.35ml/s with 23.8psi vacuum 18.9m deep (42.6psia) @17:02:46.73 Cartridge 6 filtering 616/2000ml at 0.32ml/s with 26.6psi vacuum 16.4m deep (38.9psia) @17:03:46.73 Cartridge 6 filtering 635/2000ml at 0.34ml/s with 26.9psi vacuum 16.9m deep (39.6psia) @17:04:46.74 Cartridge 6 filtering 655/2000ml at 0.31ml/s with 21.5psi vacuum 18.2m deep (41.6psia) @17:05:46.74 Cartridge 6 filtering 674/2000ml at 0.31ml/s with 19.2psi vacuum 18.2m deep (41.5psia) @17:06:46.74 Cartridge 6 filtering 692/2000ml at 0.29ml/s with 26.0psi vacuum 14.7m deep (36.4psia) @17:07:46.74 Cartridge 6 filtering 711/2000ml at 0.31ml/s with 18.4psi vacuum 22.3m deep (47.6psia) @17:08:46.73 Cartridge 6 filtering 729/2000ml at 0.32ml/s with 21.9psi vacuum 18.3m deep (41.8psia) @17:09:46.78 Cartridge 6 filtering 747/2000ml at 0.28ml/s with 24.4psi vacuum 16.6m deep (39.3psia) @17:10:46.73 Cartridge 6 filtering 764/2000ml at 0.28ml/s with 25.0psi vacuum 15.5m deep (37.6psia) @17:11:46.73 Cartridge 6 filtering 782/2000ml at 0.28ml/s with 25.3psi vacuum 15.7m deep (37.8psia) @17:12:46.74 Cartridge 6 filtering 799/2000ml at 0.28ml/s with 24.7psi vacuum 17.5m deep (40.6psia) @17:13:46.74 Cartridge 6 filtering 816/2000ml at 0.29ml/s with 26.1psi vacuum 16.7m deep (39.4psia) @17:14:46.73 Cartridge 6 filtering 832/2000ml at 0.26ml/s with 24.5psi vacuum 16.4m deep (38.9psia) @17:15:46.74 Cartridge 6 filtering 849/2000ml at 0.26ml/s with 26.5psi vacuum 14.1m deep (35.5psia) @17:16:46.73 Cartridge 6 filtering 865/2000ml at 0.26ml/s with 16.1psi vacuum 18.5m deep (42.1psia) @17:17:46.74 Cartridge 6 filtering 881/2000ml at 0.26ml/s with 25.9psi vacuum 15.2m deep (37.1psia) @17:18:46.73 Cartridge 6 filtering 896/2000ml at 0.25ml/s with 21.9psi vacuum 13.3m deep (34.4psia) @17:19:46.73 Cartridge 6 filtering 912/2000ml at 0.25ml/s with 26.6psi vacuum 14.8m deep (36.5psia) @17:20:46.74 Cartridge 6 filtering 927/2000ml at 0.28ml/s with 26.3psi vacuum 17.2m deep (40.1psia) @17:21:46.74 Cartridge 6 filtering 942/2000ml at 0.24ml/s with 16.4psi vacuum 20.0m deep (44.3psia) @17:22:46.74 Cartridge 6 filtering 957/2000ml at 0.23ml/s with 22.9psi vacuum 16.6m deep (39.3psia) @17:23:46.73 Cartridge 6 filtering 972/2000ml at 0.23ml/s with 24.3psi vacuum 15.9m deep (38.2psia) @17:24:46.73 Cartridge 6 filtering 987/2000ml at 0.23ml/s with 26.1psi vacuum 15.0m deep (36.9psia) @17:25:46.73 Cartridge 6 filtering 1001/2000ml at 0.26ml/s with 26.8psi vacuum 16.4m deep (39.0psia) @17:26:46.74 Cartridge 6 filtering 1016/2000ml at 0.23ml/s with 24.6psi vacuum 16.0m deep (38.3psia) @17:27:46.73 Cartridge 6 filtering 1030/2000ml at 0.25ml/s with 27.3psi vacuum 15.8m deep (38.0psia) @17:28:47.03 Cartridge 6 filtering 1044/2000ml at 0.23ml/s with 26.9psi vacuum 15.2m deep (37.2psia) @17:29:46.74 Cartridge 6 filtering 1058/2000ml at 0.22ml/s with 24.6psi vacuum 16.2m deep (38.7psia) @17:30:46.74 Cartridge 6 filtering 1072/2000ml at 0.21ml/s with 23.1psi vacuum 16.4m deep (38.9psia) @17:31:46.75 Cartridge 6 filtering 1085/2000ml at 0.22ml/s with 26.1psi vacuum 16.1m deep (38.5psia) @17:32:46.73 Cartridge 6 filtering 1099/2000ml at 0.24ml/s with 25.1psi vacuum 17.3m deep (40.2psia) @17:33:46.74 Cartridge 6 filtering 1112/2000ml at 0.25ml/s with 25.8psi vacuum 16.1m deep (38.4psia) @17:34:46.73 Cartridge 6 filtering 1125/2000ml at 0.21ml/s with 24.2psi vacuum 13.9m deep (35.2psia) @17:35:46.74 Cartridge 6 filtering 1138/2000ml at 0.21ml/s with 24.2psi vacuum 16.3m deep (38.7psia) @17:36:46.78 Cartridge 6 filtering 1151/2000ml at 0.21ml/s with 26.9psi vacuum 15.3m deep (37.4psia) @17:37:46.73 Cartridge 6 filtering 1164/2000ml at 0.21ml/s with 26.6psi vacuum 15.5m deep (37.6psia) @17:38:46.74 Cartridge 6 filtering 1177/2000ml at 0.23ml/s with 25.0psi vacuum 18.1m deep (41.4psia) @17:39:46.74 Cartridge 6 filtering 1189/2000ml at 0.23ml/s with 18.1psi vacuum 21.7m deep (46.7psia) @17:40:46.73 Cartridge 6 filtering 1202/2000ml at 0.22ml/s with 25.9psi vacuum 16.8m deep (39.5psia) @17:41:46.73 Cartridge 6 filtering 1214/2000ml at 0.20ml/s with 25.1psi vacuum 16.1m deep (38.4psia) @17:42:46.73 Cartridge 6 filtering 1227/2000ml at 0.22ml/s with 29.0psi vacuum 16.0m deep (38.4psia) @17:43:46.74 Cartridge 6 filtering 1239/2000ml at 0.20ml/s with 25.3psi vacuum 16.1m deep (38.4psia) @17:44:46.74 Cartridge 6 filtering 1252/2000ml at 0.20ml/s with 26.0psi vacuum 16.3m deep (38.7psia) @17:45:46.74 Cartridge 6 filtering 1264/2000ml at 0.20ml/s with 26.5psi vacuum 15.2m deep (37.2psia) @17:46:46.73 Cartridge 6 filtering 1277/2000ml at 0.20ml/s with 25.1psi vacuum 13.9m deep (35.2psia) @17:47:03.12 Flow averaged 0.31ml/s over 1:08:20 @17:47:03.16 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @17:47:03.75 Relieved excess vacuum in .6 seconds @17:47:03.78 SamplePump.seek 2000ml,1:00:28 @17:47:46.73 Cartridge 6 filtering 1289/2000ml at 0.23ml/s with 24.9psi vacuum 17.5m deep (40.6psia) @17:48:46.74 Cartridge 6 filtering 1301/2000ml at 0.20ml/s with 24.3psi vacuum 16.8m deep (39.5psia) @17:49:41.61 Flow averaged 0.21ml/s over 2:38 @17:49:41.65 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @17:49:42.24 Relieved excess vacuum in .6 seconds @17:49:42.27 SamplePump.seek 2000ml,57:45 @17:49:46.74 Cartridge 6 filtering 1314/2000ml at 0.20ml/s with 26.1psi vacuum 16.3m deep (38.9psia) @17:50:46.74 Cartridge 6 filtering 1326/2000ml at 0.20ml/s with 25.2psi vacuum 13.6m deep (34.9psia) @17:51:37.65 Flow averaged 0.21ml/s over 1:56 @17:51:37.69 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @17:51:38.29 Relieved excess vacuum in .6 seconds @17:51:38.31 SamplePump.seek 2000ml,55:46 @17:51:46.73 Cartridge 6 filtering 1338/2000ml at 0.20ml/s with 25.5psi vacuum 12.6m deep (33.3psia) @17:52:46.74 Cartridge 6 filtering 1351/2000ml at 0.20ml/s with 18.4psi vacuum 17.0m deep (39.8psia) @17:52:58.56 Flow averaged 0.21ml/s over 1:21 @17:52:58.60 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @17:52:59.19 Relieved excess vacuum in .6 seconds @17:52:59.59 SamplePump.seek 2000ml,54:24 @17:53:46.73 Cartridge 6 filtering 1363/2000ml at 0.20ml/s with 25.8psi vacuum 15.5m deep (37.6psia) @17:54:10.34 Flow averaged 0.20ml/s over 1:12 @17:54:10.38 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @17:54:10.97 Relieved excess vacuum in .6 seconds @17:54:11.00 SamplePump.seek 2000ml,53:11 @17:54:46.72 Cartridge 6 filtering 1375/2000ml at 0.20ml/s with 26.4psi vacuum 15.8m deep (38.0psia) @17:55:27.70 Flow averaged 0.21ml/s over 1:17 @17:55:27.74 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @17:55:28.33 Relieved excess vacuum in .6 seconds @17:55:28.36 SamplePump.seek 2000ml,51:53 @17:55:46.73 Cartridge 6 filtering 1387/2000ml at 0.20ml/s with 26.1psi vacuum 16.0m deep (38.3psia) @17:56:13.70 Flow averaged 0.20ml/s over 46 seconds @17:56:13.74 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @17:56:14.33 Relieved excess vacuum in .6 seconds @17:56:14.36 SamplePump.seek 2000ml,51:06 @17:56:46.73 Cartridge 6 filtering 1399/2000ml at 0.20ml/s with 25.6psi vacuum 16.5m deep (39.1psia) @17:57:04.31 Flow averaged 0.20ml/s over 50 seconds @17:57:04.35 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @17:57:04.98 Relieved excess vacuum in .7 seconds @17:57:05.01 SamplePump.seek 2000ml,50:15 @17:57:44.39 Flow averaged 0.20ml/s over 40 seconds @17:57:44.43 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @17:57:45.02 Relieved excess vacuum in .6 seconds @17:57:45.05 SamplePump.seek 2000ml,49:35 @17:57:46.73 Cartridge 6 filtering 1411/2000ml at 0.20ml/s with 26.7psi vacuum 15.1m deep (37.0psia) @17:57:59.81 Flow averaged 0.20ml/s over 15 seconds @17:57:59.86 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @17:58:00.45 Relieved excess vacuum in .6 seconds @17:58:00.47 SamplePump.seek 2000ml,49:20 @17:58:41.33 Flow averaged 0.20ml/s over 41 seconds @17:58:41.38 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @17:58:41.97 Relieved excess vacuum in .6 seconds @17:58:41.99 SamplePump.seek 2000ml,48:38 @17:58:46.73 Cartridge 6 filtering 1423/2000ml at 0.20ml/s with 26.2psi vacuum 16.3m deep (38.7psia) @17:59:07.81 Flow averaged 0.20ml/s over 26 seconds @17:59:07.85 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @17:59:08.44 Relieved excess vacuum in .6 seconds @17:59:08.47 SamplePump.seek 2000ml,48:12 @17:59:32.76 Flow averaged 0.20ml/s over 25 seconds @17:59:32.81 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @17:59:33.40 Relieved excess vacuum in .6 seconds @17:59:33.42 SamplePump.seek 2000ml,47:47 @17:59:46.72 Cartridge 6 filtering 1435/2000ml at 0.20ml/s with 26.1psi vacuum 16.2m deep (38.7psia) @17:59:50.78 Flow averaged 0.20ml/s over 18 seconds @17:59:50.82 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @17:59:51.43 Relieved excess vacuum in .7 seconds @17:59:51.46 SamplePump.seek 2000ml,47:30 @18:00:20.26 Flow averaged 0.20ml/s over 29 seconds @18:00:20.30 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @18:00:20.89 Relieved excess vacuum in .6 seconds @18:00:20.92 SamplePump.seek 2000ml,47:00 @18:00:46.77 Cartridge 6 filtering 1447/2000ml at 0.20ml/s with 26.3psi vacuum 16.1m deep (38.5psia) @18:00:47.73 Flow averaged 0.20ml/s over 27 seconds @18:00:47.76 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @18:00:48.36 Relieved excess vacuum in .6 seconds @18:00:48.39 SamplePump.seek 2000ml,46:33 @18:01:08.80 Flow averaged 0.20ml/s over 21 seconds @18:01:08.83 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @18:01:09.43 Relieved excess vacuum in .6 seconds @18:01:09.46 SamplePump.seek 2000ml,46:12 @18:01:28.82 Flow averaged 0.20ml/s over 20 seconds @18:01:28.86 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @18:01:29.45 Relieved excess vacuum in .6 seconds @18:01:29.47 SamplePump.seek 2000ml,45:53 @18:01:43.24 Flow averaged 0.20ml/s over 14 seconds @18:01:43.28 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @18:01:43.87 Relieved excess vacuum in .6 seconds @18:01:43.90 SamplePump.seek 2000ml,45:39 @18:01:46.72 Cartridge 6 filtering 1459/2000ml at 0.20ml/s with 26.3psi vacuum 16.1m deep (38.5psia) @18:01:57.75 Flow averaged 0.20ml/s over 14 seconds @18:01:57.79 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @18:01:58.39 Relieved excess vacuum in .6 seconds @18:01:58.42 SamplePump.seek 2000ml,45:25 @18:02:14.23 Flow averaged 0.20ml/s over 16 seconds @18:02:14.27 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @18:02:14.86 Relieved excess vacuum in .6 seconds @18:02:14.88 SamplePump.seek 2000ml,45:09 @18:02:25.23 Flow averaged 0.20ml/s over 11 seconds @18:02:25.25 Intake.close @18:02:25.31 Exhaust.close @18:02:25.53 Toroid.in :hold @18:02:25.61 Toroid.seek :bypass @18:02:27.26 Toroid.in :default @18:02:27.34 Toroid.seek :clear @18:02:28.96 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @18:02:28.98 Pressure.stop @18:02:29.19 Sampled 1466.1ml @18:02:31.05 -> Cmd.startProcessing @18:02:31.49 Plunge.seek :reagent @18:02:32.75 Sample loop closed. Ready to Deliver Reagents @18:02:32.77 Archive.seek :sealed @18:02:36.43 Archive.seek :evac @18:02:50.45 delay 1:00 @18:03:50.48 Archive.seek :clear @18:04:07.65 Sample preserved. Puck Full. @18:04:08.83 -> Cmd.stop @18:04:08.93 Carousel.in :default @18:04:09.05 Carousel.home.seek 6 @18:04:09.36 Plunge.seek :locked @18:04:10.39 Air.in :unlocking @18:04:10.52 Air.seek :clear @18:04:10.58 Lysis1.in :unlocking @18:04:10.74 Lysis1.seek :clear @18:04:12.00 Gate.power :motor,:OFF @18:04:12.02 Gate.power :core,:OFF @18:04:12.04 Gate.power :analytic1,:OFF @18:04:12.06 Gate.power :analytic2,:OFF @18:04:12.08 Gate.power :analytic3,:OFF @18:04:12.11 Gate.power :main,:OFF @18:04:12.14 Safely stopped and ready to power off ##-- file closed 2023-08-13T18:12:24.614Z ##-- file opened 2023-08-13T18:12:24.618Z @18:12:25.02 -> showStatus @18:12:27.04 -> Cmd.loadCartridge -1 @18:12:27.11 Gate.power :main,:ON,limit to 5000mA @18:12:27.13 Gate.power :analytic1,:ON,limit to 5000mA @18:12:27.16 Gate.power :analytic2,:ON,limit to 5000mA @18:12:27.19 Gate.power :analytic3,:ON,limit to 5000mA @18:12:27.23 Powering core bus @18:12:29.94 Archive.configure :default @18:12:30.04 Air.configure :default @18:12:30.11 Lysis1.configure :default @18:12:30.18 Lysis2.configure :default @18:12:30.27 Plunge.configure :default @18:12:30.36 SamplePump.configure :default @18:12:30.45 Toroid.configure :default @18:12:30.55 Carousel.configure :default @18:12:30.64 Pressure.configure :default @18:12:30.74 ExtraPump.configure :default @18:12:30.80 All elf controllers running firmware version 4.83 @18:12:30.83 Gate.power :motor,:ON,limit to 5000mA @18:12:31.10 Archive.home.jog 0 @18:12:31.48 Toroid.home.jog 0 @18:12:31.53 Plunge.home.jog 0 @18:12:31.56 Lysis2.home.jog 0 @18:12:31.60 Air.home.jog 0 @18:12:31.63 Carousel.home.jog 0 @18:12:31.71 Lysis1.home.jog 0 @18:12:32.23 Archive.in :homing @18:12:32.46 Archive.jog 1329 @18:12:32.50 Toroid.in :homing @18:12:32.52 Plunge.in :homing @18:12:32.55 Lysis2.in :homing @18:12:32.60 Air.in :homing @18:12:32.66 Lysis1.in :homing @18:12:32.87 Plunge.jog 765 @18:12:32.91 Toroid.jog 596 @18:12:32.94 Lysis2.jog 1360 @18:12:32.97 Lysis1.jog 1358 @18:12:33.00 Air.jog 170 @18:12:33.59 Air.setRawPosition! 50 @18:12:33.65 Air.seek :home @18:12:33.81 Archive.setRawPosition! 50 @18:12:33.87 Archive.seek :home @18:12:33.92 Plunge.setRawPosition! 50 @18:12:33.96 Air.in :default @18:12:34.10 Plunge.seek :home @18:12:34.25 Lysis2.setRawPosition! 50 @18:12:34.28 Archive.in :default @18:12:34.36 Lysis2.seek :home @18:12:34.49 Plunge.in :default @18:12:34.51 Lysis1.setRawPosition! 50 @18:12:34.61 Lysis1.seek :home @18:12:34.72 Lysis2.in :default @18:12:34.92 Lysis1.in :default @18:12:35.08 Toroid.setRawPosition! 0 @18:12:35.13 Toroid.seek :home @18:12:35.22 Toroid.in :default @18:12:35.30 Toroid.seek :clear @18:12:36.92 Carousel.in :default @18:12:37.10 Carousel.home.seek 6 @18:12:37.37 Selecting Cartridge 5 @18:12:37.59 Carousel.seek 5 @18:12:38.08 Lysis1.in :fast @18:12:38.52 Lysis1.seek :locked @18:12:40.76 Plunge.seek :locked @18:12:40.90 Air.in :fast @18:12:40.98 Air.seek :locked @18:12:42.52 Carousel.reconfigure :locked @18:12:43.18 Mounted archive Cartridge @18:12:58.96 -> Cmd.startFiltering @18:12:59.21 Preparing to filter cartridge 5 @18:12:59.51 Priming sample loop w/100ml, bypass w/10ml @18:12:59.53 SamplePump.setPosition! 0ml @18:12:59.59 Bypass.open @18:13:01.05 Intake.open @18:13:01.83 Sea 16.1m deep (38.5psia) @18:13:01.85 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @18:13:04.43 Vacuum tare is 51% of full scale @18:13:04.58 Intake.close @18:13:04.63 Bypass.close @18:13:05.37 Verifying toroid holds at least 0.6..0.85 of 38.5psia @18:13:05.39 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @18:13:09.97 Bypass.open @18:13:10.69 Intake.open @18:13:12.18 Pressure.in :default @18:13:12.25 Pressure.hold @18:13:12.44 SamplePump.in :prime @18:13:12.52 SamplePump.seek 10ml,59 seconds @18:13:23.38 Pressure.stop @18:13:23.44 SamplePump.setPosition! 0ml @18:13:23.49 Exhaust.open @18:13:24.97 Bypass.close @18:13:26.44 Pressure.in :default @18:13:26.52 Pressure.hold @18:13:26.64 Sea 16.0m deep (38.4psia) @18:13:26.79 SamplePump.in :prime @18:13:26.87 SamplePump.seek 100ml,5:16 @18:15:15.22 Pressure.stop @18:15:15.30 Bypass.open @18:15:15.98 Intake.close @18:15:16.78 Toroid.in :hold @18:15:16.85 Toroid.seek :crack @18:15:18.58 Toroid.seek :cartridge @18:15:19.56 Toroid.in :default @18:15:19.63 Toroid.seek :clear @18:15:21.68 Exhaust.close @18:15:21.73 Bypass.close @18:15:22.45 Verifying cartridge holds at least 0.65..0.85 of 38.3psia @18:15:22.47 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @18:15:27.11 Sampling 2000.0ml @18:15:27.12 SamplePump.setPosition! 0ml @18:15:27.18 Exhaust.open @18:15:27.88 Intake.open @18:15:28.77 Pressure.in :default @18:15:28.84 Pressure.hold @18:15:28.97 Sea 16.1m deep (38.5psia) @18:15:28.98 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @18:15:29.14 SamplePump.in :sample @18:15:29.22 SamplePump.seek 2000ml,2:47:06 @18:15:31.80 Cartridge 5 filtering 1/2000ml at 0.54ml/s with 23.9psi vacuum 16.4m deep (38.9psia) @18:16:31.81 Cartridge 5 filtering 32/2000ml at 0.53ml/s with 20.8psi vacuum 17.0m deep (39.7psia) @18:17:31.81 Cartridge 5 filtering 64/2000ml at 0.52ml/s with 20.3psi vacuum 17.4m deep (40.3psia) @18:18:31.81 Cartridge 5 filtering 94/2000ml at 0.50ml/s with 27.0psi vacuum 13.6m deep (34.8psia) @18:19:31.82 Cartridge 5 filtering 124/2000ml at 0.49ml/s with 26.5psi vacuum 16.1m deep (38.4psia) @18:20:31.81 Cartridge 5 filtering 153/2000ml at 0.47ml/s with 19.6psi vacuum 17.1m deep (39.9psia) @18:21:31.81 Cartridge 5 filtering 181/2000ml at 0.45ml/s with 20.0psi vacuum 15.5m deep (37.6psia) @18:22:31.81 Cartridge 5 filtering 209/2000ml at 0.45ml/s with 26.0psi vacuum 15.7m deep (38.0psia) @18:23:31.81 Cartridge 5 filtering 236/2000ml at 0.47ml/s with 22.2psi vacuum 20.0m deep (44.2psia) @18:24:31.81 Cartridge 5 filtering 263/2000ml at 0.44ml/s with 25.4psi vacuum 12.2m deep (32.7psia) @18:25:31.81 Cartridge 5 filtering 289/2000ml at 0.45ml/s with 27.5psi vacuum 15.8m deep (38.0psia) @18:26:31.81 Cartridge 5 filtering 314/2000ml at 0.40ml/s with 26.2psi vacuum 15.3m deep (37.2psia) @18:27:31.81 Cartridge 5 filtering 339/2000ml at 0.41ml/s with 26.3psi vacuum 15.8m deep (38.0psia) @18:28:31.81 Cartridge 5 filtering 364/2000ml at 0.40ml/s with 25.7psi vacuum 16.1m deep (38.5psia) @18:29:32.18 Cartridge 5 filtering 388/2000ml at 0.40ml/s with 27.3psi vacuum 9.0m deep (28.0psia) @18:30:31.85 Cartridge 5 filtering 412/2000ml at 0.37ml/s with 21.0psi vacuum 13.9m deep (35.3psia) @18:31:31.82 Cartridge 5 filtering 435/2000ml at 0.37ml/s with 25.0psi vacuum 11.4m deep (31.6psia) @18:32:31.82 Cartridge 5 filtering 458/2000ml at 0.37ml/s with 26.6psi vacuum 14.8m deep (36.6psia) @18:33:31.82 Cartridge 5 filtering 480/2000ml at 0.38ml/s with 28.1psi vacuum 15.0m deep (36.9psia) @18:34:31.81 Cartridge 5 filtering 502/2000ml at 0.37ml/s with 15.6psi vacuum 22.2m deep (47.5psia) @18:35:31.81 Cartridge 5 filtering 524/2000ml at 0.37ml/s with 27.8psi vacuum 15.0m deep (36.9psia) @18:36:31.81 Cartridge 5 filtering 545/2000ml at 0.34ml/s with 26.2psi vacuum 15.2m deep (37.1psia) @18:37:31.81 Cartridge 5 filtering 567/2000ml at 0.34ml/s with 18.6psi vacuum 16.7m deep (39.3psia) @18:38:31.81 Cartridge 5 filtering 587/2000ml at 0.36ml/s with 24.7psi vacuum 18.3m deep (41.7psia) @18:39:31.82 Cartridge 5 filtering 608/2000ml at 0.35ml/s with 27.0psi vacuum 16.6m deep (39.2psia) @18:40:31.81 Cartridge 5 filtering 628/2000ml at 0.33ml/s with 21.0psi vacuum 19.2m deep (43.1psia) @18:41:31.81 Cartridge 5 filtering 648/2000ml at 0.32ml/s with 23.8psi vacuum 17.5m deep (40.5psia) @18:42:31.81 Cartridge 5 filtering 667/2000ml at 0.32ml/s with 25.1psi vacuum 11.6m deep (31.8psia) @18:43:31.81 Cartridge 5 filtering 687/2000ml at 0.31ml/s with 23.9psi vacuum 15.0m deep (36.9psia) @18:44:31.81 Cartridge 5 filtering 706/2000ml at 0.32ml/s with 17.6psi vacuum 21.4m deep (46.4psia) @18:45:31.81 Cartridge 5 filtering 725/2000ml at 0.30ml/s with 23.9psi vacuum 17.3m deep (40.3psia) @18:46:31.81 Cartridge 5 filtering 743/2000ml at 0.30ml/s with 26.1psi vacuum 16.9m deep (39.7psia) @18:47:31.81 Cartridge 5 filtering 761/2000ml at 0.29ml/s with 26.8psi vacuum 14.3m deep (35.9psia) @18:48:31.81 Cartridge 5 filtering 779/2000ml at 0.29ml/s with 25.3psi vacuum 15.4m deep (37.5psia) @18:49:31.81 Cartridge 5 filtering 797/2000ml at 0.28ml/s with 24.6psi vacuum 14.8m deep (36.6psia) @18:50:31.81 Cartridge 5 filtering 815/2000ml at 0.28ml/s with 25.5psi vacuum 16.4m deep (38.9psia) @18:51:31.82 Cartridge 5 filtering 832/2000ml at 0.27ml/s with 22.2psi vacuum 15.6m deep (37.7psia) @18:52:31.81 Cartridge 5 filtering 849/2000ml at 0.30ml/s with 24.9psi vacuum 16.5m deep (39.0psia) @18:53:31.81 Cartridge 5 filtering 866/2000ml at 0.27ml/s with 24.6psi vacuum 16.9m deep (39.6psia) @18:54:31.81 Cartridge 5 filtering 883/2000ml at 0.27ml/s with 19.7psi vacuum 15.5m deep (37.7psia) @18:55:31.81 Cartridge 5 filtering 899/2000ml at 0.27ml/s with 23.4psi vacuum 15.1m deep (37.0psia) @18:56:31.81 Cartridge 5 filtering 916/2000ml at 0.26ml/s with 24.9psi vacuum 15.8m deep (38.0psia) @18:57:31.81 Cartridge 5 filtering 932/2000ml at 0.25ml/s with 24.4psi vacuum 15.0m deep (36.8psia) @18:58:31.81 Cartridge 5 filtering 948/2000ml at 0.27ml/s with 17.1psi vacuum 21.5m deep (46.5psia) @18:59:31.81 Cartridge 5 filtering 963/2000ml at 0.25ml/s with 25.5psi vacuum 12.3m deep (32.8psia) @19:00:31.81 Cartridge 5 filtering 979/2000ml at 0.25ml/s with 24.7psi vacuum 15.6m deep (37.7psia) @19:01:31.82 Cartridge 5 filtering 994/2000ml at 0.25ml/s with 24.9psi vacuum 16.8m deep (39.6psia) @19:02:31.81 Cartridge 5 filtering 1010/2000ml at 0.24ml/s with 24.9psi vacuum 16.3m deep (38.7psia) @19:03:31.81 Cartridge 5 filtering 1025/2000ml at 0.23ml/s with 23.8psi vacuum 16.5m deep (39.1psia) @19:04:31.81 Cartridge 5 filtering 1040/2000ml at 0.24ml/s with 27.6psi vacuum 15.5m deep (37.6psia) @19:05:32.19 Cartridge 5 filtering 1055/2000ml at 0.24ml/s with 27.4psi vacuum 14.6m deep (36.2psia) @19:06:31.81 Cartridge 5 filtering 1069/2000ml at 0.23ml/s with 24.9psi vacuum 15.7m deep (38.0psia) @19:07:31.81 Cartridge 5 filtering 1084/2000ml at 0.23ml/s with 24.0psi vacuum 17.3m deep (40.3psia) @19:08:31.81 Cartridge 5 filtering 1098/2000ml at 0.23ml/s with 24.1psi vacuum 17.0m deep (39.9psia) @19:09:31.82 Cartridge 5 filtering 1113/2000ml at 0.23ml/s with 26.9psi vacuum 16.0m deep (38.4psia) @19:10:31.81 Cartridge 5 filtering 1127/2000ml at 0.22ml/s with 25.0psi vacuum 15.8m deep (38.0psia) @19:11:31.82 Cartridge 5 filtering 1141/2000ml at 0.22ml/s with 27.7psi vacuum 15.4m deep (37.4psia) @19:12:31.82 Cartridge 5 filtering 1155/2000ml at 0.24ml/s with 20.1psi vacuum 20.5m deep (45.0psia) @19:13:31.82 Cartridge 5 filtering 1168/2000ml at 0.23ml/s with 27.3psi vacuum 16.5m deep (39.1psia) @19:14:31.80 Cartridge 5 filtering 1182/2000ml at 0.22ml/s with 21.5psi vacuum 14.9m deep (36.8psia) @19:15:31.82 Cartridge 5 filtering 1196/2000ml at 0.24ml/s with 15.5psi vacuum 22.0m deep (47.2psia) @19:16:31.81 Cartridge 5 filtering 1209/2000ml at 0.21ml/s with 23.6psi vacuum 12.4m deep (33.1psia) @19:17:31.81 Cartridge 5 filtering 1222/2000ml at 0.23ml/s with 26.6psi vacuum 16.9m deep (39.7psia) @19:18:31.82 Cartridge 5 filtering 1235/2000ml at 0.22ml/s with 19.5psi vacuum 20.7m deep (45.3psia) @19:19:31.81 Cartridge 5 filtering 1248/2000ml at 0.20ml/s with 22.9psi vacuum 17.5m deep (40.5psia) @19:20:31.81 Cartridge 5 filtering 1261/2000ml at 0.20ml/s with 23.9psi vacuum 16.0m deep (38.3psia) @19:21:31.81 Cartridge 5 filtering 1274/2000ml at 0.22ml/s with 16.3psi vacuum 20.0m deep (44.2psia) @19:22:31.81 Cartridge 5 filtering 1287/2000ml at 0.21ml/s with 26.2psi vacuum 16.4m deep (38.9psia) @19:23:31.81 Cartridge 5 filtering 1300/2000ml at 0.20ml/s with 25.5psi vacuum 15.8m deep (38.1psia) @19:24:31.81 Cartridge 5 filtering 1312/2000ml at 0.24ml/s with 26.3psi vacuum 17.3m deep (40.3psia) @19:25:31.81 Cartridge 5 filtering 1325/2000ml at 0.22ml/s with 22.5psi vacuum 19.5m deep (43.5psia) @19:26:31.81 Cartridge 5 filtering 1337/2000ml at 0.21ml/s with 25.5psi vacuum 16.7m deep (39.3psia) @19:27:31.81 Cartridge 5 filtering 1350/2000ml at 0.20ml/s with 27.2psi vacuum 15.0m deep (36.9psia) @19:28:31.81 Cartridge 5 filtering 1362/2000ml at 0.21ml/s with 20.1psi vacuum 20.1m deep (44.4psia) @19:29:31.82 Cartridge 5 filtering 1375/2000ml at 0.20ml/s with 26.6psi vacuum 15.4m deep (37.5psia) @19:30:31.81 Cartridge 5 filtering 1387/2000ml at 0.20ml/s with 25.2psi vacuum 16.9m deep (39.7psia) @19:31:31.81 Cartridge 5 filtering 1399/2000ml at 0.20ml/s with 27.3psi vacuum 15.6m deep (37.7psia) @19:32:06.53 Flow averaged 0.31ml/s over 1:16:38 @19:32:06.57 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @19:32:07.16 Relieved excess vacuum in .6 seconds @19:32:07.18 SamplePump.seek 2000ml,49:57 @19:32:31.80 Cartridge 5 filtering 1411/2000ml at 0.23ml/s with 25.2psi vacuum 18.6m deep (42.2psia) @19:33:31.81 Cartridge 5 filtering 1424/2000ml at 0.21ml/s with 28.0psi vacuum 15.6m deep (37.8psia) @19:34:31.81 Cartridge 5 filtering 1436/2000ml at 0.23ml/s with 27.8psi vacuum 16.6m deep (39.3psia) @19:34:49.55 Flow averaged 0.21ml/s over 2:43 @19:34:49.59 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @19:34:50.18 Relieved excess vacuum in .6 seconds @19:34:50.21 SamplePump.seek 2000ml,47:10 @19:35:31.82 Cartridge 5 filtering 1448/2000ml at 0.20ml/s with 28.8psi vacuum 16.2m deep (38.7psia) @19:36:31.81 Cartridge 5 filtering 1461/2000ml at 0.20ml/s with 28.5psi vacuum 15.5m deep (37.5psia) @19:36:33.54 Flow averaged 0.21ml/s over 1:44 @19:36:33.58 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @19:36:34.17 Relieved excess vacuum in .6 seconds @19:36:34.20 SamplePump.seek 2000ml,45:24 @19:37:31.81 Cartridge 5 filtering 1473/2000ml at 0.20ml/s with 27.4psi vacuum 15.4m deep (37.5psia) @19:38:31.81 Cartridge 5 filtering 1485/2000ml at 0.20ml/s with 28.2psi vacuum 16.1m deep (38.4psia) @19:38:43.53 Flow averaged 0.21ml/s over 2:10 @19:38:43.57 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @19:38:44.16 Relieved excess vacuum in .6 seconds @19:38:44.19 SamplePump.seek 2000ml,43:11 @19:39:31.80 Cartridge 5 filtering 1497/2000ml at 0.21ml/s with 16.4psi vacuum 20.7m deep (45.3psia) @19:39:48.68 Flow averaged 0.20ml/s over 1:05 @19:39:48.72 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @19:39:49.32 Relieved excess vacuum in .6 seconds @19:39:49.35 SamplePump.seek 2000ml,42:05 @19:40:31.81 Cartridge 5 filtering 1510/2000ml at 0.20ml/s with 22.5psi vacuum 14.9m deep (36.8psia) @19:40:56.65 Flow averaged 0.20ml/s over 1:08 @19:40:56.69 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @19:40:57.28 Relieved excess vacuum in .6 seconds @19:40:57.31 SamplePump.seek 2000ml,40:56 @19:41:31.80 Cartridge 5 filtering 1522/2000ml at 0.20ml/s with 26.5psi vacuum 15.8m deep (38.1psia) @19:42:02.28 Flow averaged 0.20ml/s over 1:05 @19:42:02.32 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @19:42:02.96 Relieved excess vacuum in .7 seconds @19:42:02.99 SamplePump.seek 2000ml,39:49 @19:42:30.37 Flow averaged 0.20ml/s over 28 seconds @19:42:30.42 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @19:42:31.01 Relieved excess vacuum in .6 seconds @19:42:31.04 SamplePump.seek 2000ml,39:21 @19:42:31.80 Cartridge 5 filtering 1534/2000ml at 0.21ml/s with 25.5psi vacuum 17.7m deep (40.9psia) @19:43:31.81 Cartridge 5 filtering 1546/2000ml at 0.20ml/s with 25.6psi vacuum 16.4m deep (38.9psia) @19:43:32.91 Flow averaged 0.20ml/s over 1:02 @19:43:32.95 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @19:43:33.55 Relieved excess vacuum in .6 seconds @19:43:33.58 SamplePump.seek 2000ml,38:18 @19:44:09.02 Flow averaged 0.20ml/s over 36 seconds @19:44:09.07 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @19:44:09.66 Relieved excess vacuum in .6 seconds @19:44:09.69 SamplePump.seek 2000ml,37:42 @19:44:31.81 Cartridge 5 filtering 1558/2000ml at 0.20ml/s with 28.1psi vacuum 16.3m deep (38.8psia) @19:44:55.86 Flow averaged 0.20ml/s over 47 seconds @19:44:55.91 Waiting up to 12 seconds for vacuum to reduce from 27.4 to 18.0psi @19:44:56.69 Relieved excess vacuum in .8 seconds @19:44:56.72 SamplePump.seek 2000ml,36:55 @19:45:18.26 Flow averaged 0.20ml/s over 22 seconds @19:45:18.31 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @19:45:18.90 Relieved excess vacuum in .6 seconds @19:45:18.93 SamplePump.seek 2000ml,36:33 @19:45:31.81 Cartridge 5 filtering 1570/2000ml at 0.20ml/s with 26.6psi vacuum 16.5m deep (39.0psia) @19:45:46.31 Flow averaged 0.20ml/s over 28 seconds @19:45:46.35 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @19:45:46.94 Relieved excess vacuum in .6 seconds @19:45:46.97 SamplePump.seek 2000ml,36:05 @19:46:06.72 Flow averaged 0.20ml/s over 20 seconds @19:46:06.76 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @19:46:07.35 Relieved excess vacuum in .6 seconds @19:46:07.38 SamplePump.seek 2000ml,35:45 @19:46:31.80 Cartridge 5 filtering 1582/2000ml at 0.20ml/s with 26.2psi vacuum 15.8m deep (38.1psia) @19:46:34.05 Flow averaged 0.20ml/s over 27 seconds @19:46:34.09 Waiting up to 12 seconds for vacuum to reduce from 27.6 to 18.0psi @19:46:34.68 Relieved excess vacuum in .6 seconds @19:46:34.71 SamplePump.seek 2000ml,35:18 @19:47:04.21 Flow averaged 0.20ml/s over 30 seconds @19:47:04.25 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @19:47:04.84 Relieved excess vacuum in .6 seconds @19:47:04.87 SamplePump.seek 2000ml,34:48 @19:47:31.81 Cartridge 5 filtering 1594/2000ml at 0.20ml/s with 26.8psi vacuum 15.7m deep (37.8psia) @19:47:42.57 Flow averaged 0.20ml/s over 38 seconds @19:47:42.61 Waiting up to 11 seconds for vacuum to reduce from 27.3 to 18.0psi @19:47:43.20 Relieved excess vacuum in .6 seconds @19:47:43.22 SamplePump.seek 2000ml,34:09 @19:47:51.25 Flow estimate reduced to 0.16ml/s @19:47:51.28 Intake.close @19:47:51.36 Exhaust.close @19:47:51.58 Toroid.in :hold @19:47:51.66 Toroid.seek :bypass @19:47:53.31 Toroid.in :default @19:47:53.43 Toroid.seek :clear @19:47:55.05 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @19:47:55.08 Pressure.stop @19:47:55.27 Sampled 1597.6ml @19:47:57.15 -> Cmd.startProcessing @19:47:57.58 Plunge.seek :reagent @19:47:58.49 Sample loop closed. Ready to Deliver Reagents @19:47:58.51 Archive.seek :sealed @19:48:02.17 Archive.seek :evac @19:48:16.18 delay 1:00 @19:49:16.56 Archive.seek :clear @19:49:33.75 Sample preserved. Puck Full. @19:49:34.92 -> Cmd.stop @19:49:35.01 Carousel.in :default @19:49:35.14 Carousel.home.seek 5 @19:49:35.44 Plunge.seek :locked @19:49:36.47 Air.in :unlocking @19:49:36.61 Air.seek :clear @19:49:36.71 Lysis1.in :unlocking @19:49:36.83 Lysis1.seek :clear @19:49:38.08 Gate.power :motor,:OFF @19:49:38.10 Gate.power :core,:OFF @19:49:38.12 Gate.power :analytic1,:OFF @19:49:38.14 Gate.power :analytic2,:OFF @19:49:38.16 Gate.power :analytic3,:OFF @19:49:38.19 Gate.power :main,:OFF @19:49:38.21 Safely stopped and ready to power off ##-- file closed 2023-08-13T19:57:51.842Z ##-- file opened 2023-08-13T19:57:51.844Z @19:57:52.27 -> showStatus @19:57:54.30 -> Cmd.loadCartridge -1 @19:57:54.36 Gate.power :main,:ON,limit to 5000mA @19:57:54.38 Gate.power :analytic1,:ON,limit to 5000mA @19:57:54.40 Gate.power :analytic2,:ON,limit to 5000mA @19:57:54.43 Gate.power :analytic3,:ON,limit to 5000mA @19:57:54.47 Powering core bus @19:57:57.18 Archive.configure :default @19:57:57.28 Air.configure :default @19:57:57.35 Lysis1.configure :default @19:57:57.41 Lysis2.configure :default @19:57:57.50 Plunge.configure :default @19:57:57.59 SamplePump.configure :default @19:57:57.68 Toroid.configure :default @19:57:57.77 Carousel.configure :default @19:57:57.87 Pressure.configure :default @19:57:57.96 ExtraPump.configure :default @19:57:58.03 All elf controllers running firmware version 4.83 @19:57:58.05 Gate.power :motor,:ON,limit to 5000mA @19:57:58.24 Archive.home.jog 0 @19:57:58.71 Toroid.home.jog 0 @19:57:58.73 Plunge.home.jog 0 @19:57:58.76 Lysis2.home.jog 0 @19:57:58.82 Carousel.home.jog 0 @19:57:58.86 Air.home.jog 0 @19:57:58.88 Lysis1.home.jog 0 @19:57:59.29 Archive.in :homing @19:57:59.54 Toroid.in :homing @19:57:59.59 Lysis2.in :homing @19:57:59.62 Archive.jog 1356 @19:57:59.65 Plunge.in :homing @19:57:59.81 Toroid.jog 590 @19:57:59.85 Lysis2.jog 1365 @19:57:59.92 Plunge.jog 767 @19:58:00.07 Air.in :homing @19:58:00.09 Lysis1.in :homing @19:58:00.19 Air.jog 172 @19:58:00.30 Lysis1.jog 1363 @19:58:00.74 Air.setRawPosition! 50 @19:58:00.79 Air.seek :home @19:58:00.87 Plunge.setRawPosition! 50 @19:58:00.93 Plunge.seek :home @19:58:01.01 Archive.setRawPosition! 50 @19:58:01.07 Archive.seek :home @19:58:01.17 Air.in :default @19:58:01.19 Lysis2.setRawPosition! 50 @19:58:01.29 Lysis2.seek :home @19:58:01.39 Plunge.in :default @19:58:01.42 Archive.in :default @19:58:01.55 Lysis1.setRawPosition! 50 @19:58:01.61 Lysis1.seek :home @19:58:01.70 Lysis2.in :default @19:58:01.89 Toroid.setRawPosition! 0 @19:58:01.94 Toroid.seek :home @19:58:02.02 Lysis1.in :default @19:58:02.12 Toroid.in :default @19:58:02.39 Toroid.seek :clear @19:58:04.01 Carousel.in :default @19:58:04.13 Carousel.home.seek 5 @19:58:04.39 Selecting Cartridge 4 @19:58:04.60 Carousel.seek 4 @19:58:05.50 Lysis1.in :fast @19:58:05.57 Lysis1.seek :locked @19:58:07.81 Plunge.seek :locked @19:58:07.95 Air.in :fast @19:58:08.02 Air.seek :locked @19:58:09.56 Carousel.reconfigure :locked @19:58:10.22 Mounted archive Cartridge @19:58:26.21 -> Cmd.startFiltering @19:58:26.52 Preparing to filter cartridge 4 @19:58:26.81 Priming sample loop w/100ml, bypass w/10ml @19:58:26.83 SamplePump.setPosition! 0ml @19:58:26.88 Bypass.open @19:58:28.31 Intake.open @19:58:29.08 Sea 16.1m deep (38.5psia) @19:58:29.10 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @19:58:31.68 Vacuum tare is 51% of full scale @19:58:31.87 Intake.close @19:58:31.92 Bypass.close @19:58:32.64 Verifying toroid holds at least 0.6..0.85 of 38.4psia @19:58:32.66 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @19:58:37.24 Bypass.open @19:58:37.92 Intake.open @19:58:39.38 Pressure.in :default @19:58:39.45 Pressure.hold @19:58:39.65 SamplePump.in :prime @19:58:39.73 SamplePump.seek 10ml,59 seconds @19:58:50.58 Pressure.stop @19:58:50.64 SamplePump.setPosition! 0ml @19:58:50.70 Exhaust.open @19:58:52.14 Bypass.close @19:58:53.60 Pressure.in :default @19:58:53.67 Pressure.hold @19:58:53.79 Sea 16.1m deep (38.5psia) @19:58:53.94 SamplePump.in :prime @19:58:54.02 SamplePump.seek 100ml,5:16 @20:00:42.81 Pressure.stop @20:00:42.89 Bypass.open @20:00:43.55 Intake.close @20:00:44.33 Toroid.in :hold @20:00:44.40 Toroid.seek :crack @20:00:46.13 Toroid.seek :cartridge @20:00:47.11 Toroid.in :default @20:00:47.17 Toroid.seek :clear @20:00:49.27 Exhaust.close @20:00:49.30 Bypass.close @20:00:50.03 Verifying cartridge holds at least 0.65..0.85 of 38.4psia @20:00:50.05 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @20:00:54.70 Sampling 2000.0ml @20:00:54.71 SamplePump.setPosition! 0ml @20:00:54.78 Exhaust.open @20:00:55.47 Intake.open @20:00:56.33 Pressure.in :default @20:00:56.40 Pressure.hold @20:00:56.52 Sea 16.1m deep (38.5psia) @20:00:56.54 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @20:00:56.70 SamplePump.in :sample @20:00:56.78 SamplePump.seek 2000ml,2:47:06 @20:00:59.37 Cartridge 4 filtering 1/2000ml at 0.55ml/s with 25.2psi vacuum 16.5m deep (39.1psia) @20:01:59.38 Cartridge 4 filtering 33/2000ml at 0.52ml/s with 25.9psi vacuum 16.0m deep (38.4psia) @20:02:59.38 Cartridge 4 filtering 64/2000ml at 0.49ml/s with 21.4psi vacuum 15.6m deep (37.7psia) @20:03:59.43 Cartridge 4 filtering 94/2000ml at 0.49ml/s with 19.2psi vacuum 18.9m deep (42.6psia) @20:04:59.38 Cartridge 4 filtering 124/2000ml at 0.48ml/s with 25.9psi vacuum 15.9m deep (38.2psia) @20:05:59.38 Cartridge 4 filtering 154/2000ml at 0.48ml/s with 22.7psi vacuum 18.1m deep (41.5psia) @20:06:59.38 Cartridge 4 filtering 182/2000ml at 0.49ml/s with 25.5psi vacuum 17.0m deep (39.9psia) @20:07:59.38 Cartridge 4 filtering 210/2000ml at 0.48ml/s with 23.0psi vacuum 17.6m deep (40.7psia) @20:08:59.38 Cartridge 4 filtering 238/2000ml at 0.43ml/s with 25.9psi vacuum 11.1m deep (31.1psia) @20:09:59.38 Cartridge 4 filtering 265/2000ml at 0.44ml/s with 21.8psi vacuum 19.9m deep (44.1psia) @20:10:59.38 Cartridge 4 filtering 291/2000ml at 0.44ml/s with 27.5psi vacuum 15.6m deep (37.8psia) @20:11:59.38 Cartridge 4 filtering 317/2000ml at 0.43ml/s with 27.1psi vacuum 13.9m deep (35.3psia) @20:12:59.38 Cartridge 4 filtering 342/2000ml at 0.40ml/s with 25.4psi vacuum 10.6m deep (30.4psia) @20:13:59.38 Cartridge 4 filtering 367/2000ml at 0.40ml/s with 20.3psi vacuum 20.0m deep (44.3psia) @20:14:59.75 Cartridge 4 filtering 391/2000ml at 0.39ml/s with 16.3psi vacuum 22.9m deep (48.6psia) @20:15:59.38 Cartridge 4 filtering 415/2000ml at 0.38ml/s with 24.4psi vacuum 16.9m deep (39.7psia) @20:16:59.39 Cartridge 4 filtering 438/2000ml at 0.39ml/s with 17.5psi vacuum 23.3m deep (49.1psia) @20:17:59.38 Cartridge 4 filtering 461/2000ml at 0.38ml/s with 26.6psi vacuum 16.3m deep (38.8psia) @20:18:59.38 Cartridge 4 filtering 483/2000ml at 0.37ml/s with 26.3psi vacuum 14.4m deep (36.0psia) @20:19:59.38 Cartridge 4 filtering 506/2000ml at 0.38ml/s with 23.4psi vacuum 19.2m deep (43.1psia) @20:20:59.38 Cartridge 4 filtering 527/2000ml at 0.35ml/s with 18.3psi vacuum 16.7m deep (39.4psia) @20:21:59.38 Cartridge 4 filtering 549/2000ml at 0.35ml/s with 25.9psi vacuum 16.6m deep (39.2psia) @20:22:59.38 Cartridge 4 filtering 570/2000ml at 0.35ml/s with 26.4psi vacuum 16.5m deep (39.0psia) @20:23:59.38 Cartridge 4 filtering 591/2000ml at 0.33ml/s with 24.8psi vacuum 15.8m deep (38.0psia) @20:24:59.38 Cartridge 4 filtering 611/2000ml at 0.33ml/s with 15.9psi vacuum 21.4m deep (46.4psia) @20:25:59.37 Cartridge 4 filtering 631/2000ml at 0.35ml/s with 24.7psi vacuum 15.8m deep (38.0psia) @20:26:59.38 Cartridge 4 filtering 651/2000ml at 0.35ml/s with 25.4psi vacuum 18.7m deep (42.3psia) @20:27:59.43 Cartridge 4 filtering 671/2000ml at 0.34ml/s with 19.7psi vacuum 21.7m deep (46.7psia) @20:28:59.38 Cartridge 4 filtering 690/2000ml at 0.31ml/s with 25.5psi vacuum 16.6m deep (39.3psia) @20:29:59.38 Cartridge 4 filtering 709/2000ml at 0.30ml/s with 24.6psi vacuum 16.3m deep (38.8psia) @20:30:59.38 Cartridge 4 filtering 728/2000ml at 0.30ml/s with 22.8psi vacuum 12.4m deep (33.0psia) @20:31:59.38 Cartridge 4 filtering 746/2000ml at 0.29ml/s with 23.4psi vacuum 11.9m deep (32.3psia) @20:32:59.38 Cartridge 4 filtering 764/2000ml at 0.30ml/s with 25.3psi vacuum 17.4m deep (40.5psia) @20:33:59.38 Cartridge 4 filtering 782/2000ml at 0.29ml/s with 21.3psi vacuum 17.6m deep (40.8psia) @20:34:59.38 Cartridge 4 filtering 800/2000ml at 0.28ml/s with 26.4psi vacuum 14.9m deep (36.7psia) @20:35:59.38 Cartridge 4 filtering 817/2000ml at 0.30ml/s with 28.0psi vacuum 15.2m deep (37.2psia) @20:36:59.38 Cartridge 4 filtering 835/2000ml at 0.27ml/s with 24.0psi vacuum 16.7m deep (39.4psia) @20:37:59.38 Cartridge 4 filtering 851/2000ml at 0.27ml/s with 20.3psi vacuum 19.2m deep (43.1psia) @20:38:59.38 Cartridge 4 filtering 868/2000ml at 0.26ml/s with 24.1psi vacuum 16.6m deep (39.2psia) @20:39:59.38 Cartridge 4 filtering 885/2000ml at 0.30ml/s with 24.9psi vacuum 18.7m deep (42.4psia) @20:40:59.38 Cartridge 4 filtering 901/2000ml at 0.26ml/s with 24.0psi vacuum 16.4m deep (38.9psia) @20:41:59.38 Cartridge 4 filtering 917/2000ml at 0.29ml/s with 24.8psi vacuum 16.5m deep (39.1psia) @20:42:59.43 Cartridge 4 filtering 933/2000ml at 0.25ml/s with 25.6psi vacuum 16.2m deep (38.7psia) @20:43:59.38 Cartridge 4 filtering 949/2000ml at 0.28ml/s with 26.4psi vacuum 17.6m deep (40.8psia) @20:44:59.38 Cartridge 4 filtering 964/2000ml at 0.26ml/s with 21.5psi vacuum 19.9m deep (44.2psia) @20:45:59.38 Cartridge 4 filtering 980/2000ml at 0.28ml/s with 23.6psi vacuum 19.2m deep (43.1psia) @20:46:59.38 Cartridge 4 filtering 995/2000ml at 0.24ml/s with 24.6psi vacuum 17.1m deep (40.0psia) @20:47:59.38 Cartridge 4 filtering 1010/2000ml at 0.27ml/s with 25.5psi vacuum 16.4m deep (38.9psia) @20:48:59.38 Cartridge 4 filtering 1025/2000ml at 0.27ml/s with 25.9psi vacuum 16.1m deep (38.4psia) @20:49:59.38 Cartridge 4 filtering 1040/2000ml at 0.24ml/s with 20.4psi vacuum 18.7m deep (42.4psia) @20:50:59.45 Cartridge 4 filtering 1054/2000ml at 0.24ml/s with 24.7psi vacuum 18.0m deep (41.3psia) @20:51:59.38 Cartridge 4 filtering 1068/2000ml at 0.25ml/s with 25.3psi vacuum 17.0m deep (39.7psia) @20:52:59.38 Cartridge 4 filtering 1083/2000ml at 0.23ml/s with 26.9psi vacuum 16.2m deep (38.7psia) @20:53:59.38 Cartridge 4 filtering 1097/2000ml at 0.23ml/s with 20.7psi vacuum 19.2m deep (43.1psia) @20:54:59.38 Cartridge 4 filtering 1111/2000ml at 0.22ml/s with 20.1psi vacuum 18.5m deep (42.0psia) @20:55:59.38 Cartridge 4 filtering 1124/2000ml at 0.21ml/s with 26.3psi vacuum 14.7m deep (36.4psia) @20:56:59.38 Cartridge 4 filtering 1138/2000ml at 0.22ml/s with 26.3psi vacuum 15.6m deep (37.8psia) @20:57:59.38 Cartridge 4 filtering 1152/2000ml at 0.21ml/s with 23.5psi vacuum 16.6m deep (39.2psia) @20:58:59.37 Cartridge 4 filtering 1165/2000ml at 0.22ml/s with 24.1psi vacuum 15.1m deep (37.0psia) @20:59:59.38 Cartridge 4 filtering 1178/2000ml at 0.21ml/s with 26.7psi vacuum 14.8m deep (36.5psia) @21:00:59.38 Cartridge 4 filtering 1191/2000ml at 0.22ml/s with 26.7psi vacuum 16.5m deep (39.1psia) @21:01:59.38 Cartridge 4 filtering 1204/2000ml at 0.23ml/s with 25.7psi vacuum 17.5m deep (40.5psia) @21:02:59.38 Cartridge 4 filtering 1217/2000ml at 0.20ml/s with 26.5psi vacuum 14.9m deep (36.8psia) @21:03:59.38 Cartridge 4 filtering 1230/2000ml at 0.24ml/s with 24.3psi vacuum 18.4m deep (41.9psia) @21:04:59.39 Cartridge 4 filtering 1243/2000ml at 0.23ml/s with 26.6psi vacuum 16.1m deep (38.4psia) @21:05:59.38 Cartridge 4 filtering 1255/2000ml at 0.20ml/s with 24.5psi vacuum 14.4m deep (35.9psia) @21:06:59.42 Cartridge 4 filtering 1268/2000ml at 0.20ml/s with 23.9psi vacuum 14.8m deep (36.6psia) @21:07:59.38 Cartridge 4 filtering 1280/2000ml at 0.24ml/s with 25.7psi vacuum 18.1m deep (41.4psia) @21:08:59.38 Cartridge 4 filtering 1293/2000ml at 0.23ml/s with 19.3psi vacuum 21.9m deep (47.1psia) @21:09:59.38 Cartridge 4 filtering 1305/2000ml at 0.20ml/s with 26.0psi vacuum 14.1m deep (35.6psia) @21:10:59.38 Cartridge 4 filtering 1318/2000ml at 0.20ml/s with 27.3psi vacuum 16.0m deep (38.4psia) @21:11:59.38 Cartridge 4 filtering 1330/2000ml at 0.20ml/s with 26.1psi vacuum 16.3m deep (38.8psia) @21:12:00.82 Flow averaged 0.31ml/s over 1:11:05 @21:12:00.87 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @21:12:01.45 Relieved excess vacuum in .6 seconds @21:12:01.48 SamplePump.seek 2000ml,56:18 @21:12:59.37 Cartridge 4 filtering 1342/2000ml at 0.20ml/s with 25.8psi vacuum 12.8m deep (33.5psia) @21:13:59.38 Cartridge 4 filtering 1355/2000ml at 0.23ml/s with 26.5psi vacuum 18.5m deep (42.0psia) @21:14:37.56 Flow averaged 0.21ml/s over 2:37 @21:14:37.60 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @21:14:38.19 Relieved excess vacuum in .6 seconds @21:14:38.22 SamplePump.seek 2000ml,53:37 @21:14:59.37 Cartridge 4 filtering 1367/2000ml at 0.20ml/s with 25.2psi vacuum 17.1m deep (39.9psia) @21:15:59.38 Cartridge 4 filtering 1379/2000ml at 0.20ml/s with 25.3psi vacuum 12.1m deep (32.6psia) @21:16:18.26 Flow averaged 0.21ml/s over 1:41 @21:16:18.30 Waiting up to 12 seconds for vacuum to reduce from 27.6 to 18.0psi @21:16:18.89 Relieved excess vacuum in .6 seconds @21:16:18.92 SamplePump.seek 2000ml,51:54 @21:16:59.74 Cartridge 4 filtering 1391/2000ml at 0.23ml/s with 27.3psi vacuum 18.2m deep (41.5psia) @21:17:34.55 Flow averaged 0.21ml/s over 1:16 @21:17:34.59 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @21:17:35.19 Relieved excess vacuum in .6 seconds @21:17:35.22 SamplePump.seek 2000ml,50:36 @21:17:59.37 Cartridge 4 filtering 1404/2000ml at 0.20ml/s with 25.3psi vacuum 17.0m deep (39.8psia) @21:18:42.42 Flow averaged 0.21ml/s over 1:08 @21:18:42.47 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @21:18:43.05 Relieved excess vacuum in .6 seconds @21:18:43.08 SamplePump.seek 2000ml,49:27 @21:18:59.37 Cartridge 4 filtering 1416/2000ml at 0.20ml/s with 26.3psi vacuum 16.8m deep (39.6psia) @21:19:36.25 Flow averaged 0.21ml/s over 54 seconds @21:19:36.29 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @21:19:36.88 Relieved excess vacuum in .6 seconds @21:19:36.91 SamplePump.seek 2000ml,48:32 @21:19:59.39 Cartridge 4 filtering 1428/2000ml at 0.21ml/s with 21.4psi vacuum 19.9m deep (44.1psia) @21:20:29.21 Flow averaged 0.21ml/s over 53 seconds @21:20:29.25 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @21:20:29.84 Relieved excess vacuum in .6 seconds @21:20:29.87 SamplePump.seek 2000ml,47:39 @21:20:59.37 Cartridge 4 filtering 1440/2000ml at 0.23ml/s with 23.2psi vacuum 19.9m deep (44.1psia) @21:21:10.96 Flow averaged 0.20ml/s over 42 seconds @21:21:11.00 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @21:21:11.60 Relieved excess vacuum in .6 seconds @21:21:11.63 SamplePump.seek 2000ml,46:56 @21:21:49.59 Flow averaged 0.20ml/s over 38 seconds @21:21:49.64 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @21:21:50.27 Relieved excess vacuum in .7 seconds @21:21:50.30 SamplePump.seek 2000ml,46:18 @21:21:59.37 Cartridge 4 filtering 1452/2000ml at 0.20ml/s with 26.7psi vacuum 17.3m deep (40.2psia) @21:22:43.18 Flow averaged 0.20ml/s over 53 seconds @21:22:43.23 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @21:22:43.82 Relieved excess vacuum in .6 seconds @21:22:43.85 SamplePump.seek 2000ml,45:24 @21:22:59.37 Cartridge 4 filtering 1464/2000ml at 0.21ml/s with 17.6psi vacuum 20.1m deep (44.3psia) @21:23:05.24 Flow averaged 0.20ml/s over 22 seconds @21:23:05.29 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @21:23:05.87 Relieved excess vacuum in .6 seconds @21:23:05.90 SamplePump.seek 2000ml,45:02 @21:23:34.55 Flow averaged 0.20ml/s over 29 seconds @21:23:34.59 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @21:23:35.17 Relieved excess vacuum in .6 seconds @21:23:35.21 SamplePump.seek 2000ml,44:33 @21:23:52.00 Flow averaged 0.20ml/s over 17 seconds @21:23:52.06 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @21:23:53.02 Relieved excess vacuum in 1 second @21:23:53.05 SamplePump.seek 2000ml,44:16 @21:23:59.38 Cartridge 4 filtering 1476/2000ml at 0.20ml/s with 27.9psi vacuum 15.6m deep (37.8psia) @21:24:17.53 Flow averaged 0.20ml/s over 25 seconds @21:24:17.57 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @21:24:18.16 Relieved excess vacuum in .6 seconds @21:24:18.19 SamplePump.seek 2000ml,43:51 @21:24:42.37 Flow averaged 0.20ml/s over 25 seconds @21:24:42.41 Waiting up to 8 seconds for vacuum to reduce from 26.2 to 18.0psi @21:24:42.99 Relieved excess vacuum in .6 seconds @21:24:43.02 SamplePump.seek 2000ml,43:26 @21:24:59.37 Cartridge 4 filtering 1488/2000ml at 0.20ml/s with 26.5psi vacuum 15.8m deep (38.1psia) @21:25:05.83 Flow averaged 0.20ml/s over 23 seconds @21:25:05.87 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @21:25:06.46 Relieved excess vacuum in .6 seconds @21:25:06.49 SamplePump.seek 2000ml,43:03 @21:25:29.56 Flow averaged 0.20ml/s over 24 seconds @21:25:29.61 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @21:25:30.19 Relieved excess vacuum in .6 seconds @21:25:30.22 SamplePump.seek 2000ml,42:40 @21:25:51.13 Flow averaged 0.20ml/s over 21 seconds @21:25:51.17 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @21:25:51.75 Relieved excess vacuum in .6 seconds @21:25:51.79 SamplePump.seek 2000ml,42:19 @21:25:59.38 Cartridge 4 filtering 1500/2000ml at 0.21ml/s with 29.4psi vacuum 16.1m deep (38.5psia) @21:26:08.61 Flow averaged 0.20ml/s over 17 seconds @21:26:08.65 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @21:26:09.23 Relieved excess vacuum in .6 seconds @21:26:09.26 SamplePump.seek 2000ml,42:02 @21:26:25.08 Flow averaged 0.20ml/s over 16 seconds @21:26:25.12 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @21:26:25.70 Relieved excess vacuum in .6 seconds @21:26:25.73 SamplePump.seek 2000ml,41:46 @21:26:51.58 Flow averaged 0.20ml/s over 26 seconds @21:26:51.62 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @21:26:52.21 Relieved excess vacuum in .6 seconds @21:26:52.24 SamplePump.seek 2000ml,41:19 @21:26:59.37 Cartridge 4 filtering 1511/2000ml at 0.22ml/s with 27.4psi vacuum 18.4m deep (41.9psia) @21:27:11.89 Flow averaged 0.20ml/s over 20 seconds @21:27:11.93 Waiting up to 12 seconds for vacuum to reduce from 27.5 to 18.0psi @21:27:12.52 Relieved excess vacuum in .6 seconds @21:27:12.55 SamplePump.seek 2000ml,40:59 @21:27:21.63 Flow averaged 0.20ml/s over 10 seconds @21:27:21.66 Intake.close @21:27:21.73 Exhaust.close @21:27:21.94 Toroid.in :hold @21:27:22.02 Toroid.seek :bypass @21:27:23.68 Toroid.in :default @21:27:23.76 Toroid.seek :clear @21:27:25.38 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @21:27:25.40 Pressure.stop @21:27:25.60 Sampled 1515.8ml @21:27:27.69 -> Cmd.startProcessing @21:27:28.14 Plunge.seek :reagent @21:27:29.04 Sample loop closed. Ready to Deliver Reagents @21:27:29.06 Archive.seek :sealed @21:27:32.71 Archive.seek :evac @21:27:46.71 delay 1:00 @21:28:46.74 Archive.seek :clear @21:29:03.91 Sample preserved. Puck Full. @21:29:05.07 -> Cmd.stop @21:29:05.16 Carousel.in :default @21:29:05.28 Carousel.home.seek 4 @21:29:05.60 Plunge.seek :locked @21:29:06.63 Air.in :unlocking @21:29:06.76 Air.seek :clear @21:29:06.81 Lysis1.in :unlocking @21:29:06.99 Lysis1.seek :clear @21:29:08.24 Gate.power :motor,:OFF @21:29:08.26 Gate.power :core,:OFF @21:29:08.28 Gate.power :analytic1,:OFF @21:29:08.31 Gate.power :analytic2,:OFF @21:29:08.34 Gate.power :analytic3,:OFF @21:29:08.36 Gate.power :main,:OFF @21:29:08.37 Safely stopped and ready to power off ##-- file closed 2023-08-13T21:37:21.570Z ##-- file opened 2023-08-13T21:37:21.573Z @21:37:21.87 -> showStatus @21:37:23.89 -> Cmd.loadCartridge -1 @21:37:23.95 Gate.power :main,:ON,limit to 5000mA @21:37:23.97 Gate.power :analytic1,:ON,limit to 5000mA @21:37:24.00 Gate.power :analytic2,:ON,limit to 5000mA @21:37:24.02 Gate.power :analytic3,:ON,limit to 5000mA @21:37:24.07 Powering core bus @21:37:26.78 Archive.configure :default @21:37:26.87 Air.configure :default @21:37:26.94 Lysis1.configure :default @21:37:27.01 Lysis2.configure :default @21:37:27.10 Plunge.configure :default @21:37:27.19 SamplePump.configure :default @21:37:27.28 Toroid.configure :default @21:37:27.37 Carousel.configure :default @21:37:27.46 Pressure.configure :default @21:37:27.55 ExtraPump.configure :default @21:37:27.62 All elf controllers running firmware version 4.83 @21:37:27.65 Gate.power :motor,:ON,limit to 5000mA @21:37:27.86 Archive.home.jog 0 @21:37:28.31 Toroid.home.jog 0 @21:37:28.35 Lysis2.home.jog 0 @21:37:28.39 Plunge.home.jog 0 @21:37:28.43 Air.home.jog 0 @21:37:28.47 Carousel.home.jog 0 @21:37:28.50 Lysis1.home.jog 0 @21:37:28.93 Archive.in :homing @21:37:29.19 Archive.jog 1355 @21:37:29.23 Plunge.in :homing @21:37:29.25 Lysis2.in :homing @21:37:29.28 Air.in :homing @21:37:29.33 Toroid.in :homing @21:37:29.52 Lysis2.jog 1366 @21:37:29.57 Plunge.jog 769 @21:37:29.59 Toroid.jog 597 @21:37:29.66 Air.jog 170 @21:37:29.82 Lysis1.in :homing @21:37:29.89 Lysis1.jog 1363 @21:37:30.18 Air.setRawPosition! 50 @21:37:30.23 Air.seek :home @21:37:30.51 Air.in :default @21:37:30.60 Plunge.setRawPosition! 50 @21:37:30.62 Archive.setRawPosition! 50 @21:37:30.76 Plunge.seek :home @21:37:30.80 Archive.seek :home @21:37:30.93 Lysis2.setRawPosition! 50 @21:37:30.99 Lysis2.seek :home @21:37:31.09 Lysis1.setRawPosition! 50 @21:37:31.16 Plunge.in :default @21:37:31.20 Lysis1.seek :home @21:37:31.23 Archive.in :default @21:37:31.40 Lysis2.in :default @21:37:31.53 Lysis1.in :default @21:37:31.74 Toroid.setRawPosition! 0 @21:37:31.80 Toroid.seek :home @21:37:31.88 Toroid.in :default @21:37:31.96 Toroid.seek :clear @21:37:33.58 Carousel.in :default @21:37:33.71 Carousel.home.seek 4 @21:37:33.97 Selecting Cartridge 3 @21:37:34.19 Carousel.seek 3 @21:37:35.04 Lysis1.in :fast @21:37:35.11 Lysis1.seek :locked @21:37:37.35 Plunge.seek :locked @21:37:37.49 Air.in :fast @21:37:37.56 Air.seek :locked @21:37:39.10 Carousel.reconfigure :locked @21:37:39.75 Mounted archive Cartridge @21:37:55.80 -> Cmd.startFiltering @21:37:56.06 Preparing to filter cartridge 3 @21:37:56.34 Priming sample loop w/100ml, bypass w/10ml @21:37:56.35 SamplePump.setPosition! 0ml @21:37:56.40 Bypass.open @21:37:57.84 Intake.open @21:37:58.59 Sea 16.2m deep (38.6psia) @21:37:58.61 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @21:38:01.20 Vacuum tare is 51% of full scale @21:38:01.35 Intake.close @21:38:01.40 Bypass.close @21:38:02.11 Verifying toroid holds at least 0.6..0.85 of 38.6psia @21:38:02.13 Waiting up to 40 seconds for toroid pressure to stabilize +/-1.50psi @21:38:06.71 Bypass.open @21:38:07.45 Intake.open @21:38:08.90 Pressure.in :default @21:38:08.96 Pressure.hold @21:38:09.16 SamplePump.in :prime @21:38:09.24 SamplePump.seek 10ml,59 seconds @21:38:20.10 Pressure.stop @21:38:20.15 SamplePump.setPosition! 0ml @21:38:20.21 Exhaust.open @21:38:21.72 Bypass.close @21:38:23.23 Pressure.in :default @21:38:23.30 Pressure.hold @21:38:23.43 Sea 16.1m deep (38.5psia) @21:38:23.58 SamplePump.in :prime @21:38:24.01 SamplePump.seek 100ml,5:16 @21:40:12.41 Pressure.stop @21:40:12.48 Bypass.open @21:40:13.21 Intake.close @21:40:13.98 Toroid.in :hold @21:40:14.05 Toroid.seek :crack @21:40:15.78 Toroid.seek :cartridge @21:40:16.75 Toroid.in :default @21:40:16.82 Toroid.seek :clear @21:40:18.87 Exhaust.close @21:40:18.90 Bypass.close @21:40:19.62 Verifying cartridge holds at least 0.65..0.85 of 38.5psia @21:40:19.64 Waiting up to 40 seconds for cartridge pressure to stabilize +/-1.50psi @21:40:24.28 Sampling 2000.0ml @21:40:24.30 SamplePump.setPosition! 0ml @21:40:24.36 Exhaust.open @21:40:25.06 Intake.open @21:40:25.95 Pressure.in :default @21:40:26.02 Pressure.hold @21:40:26.14 Sea 16.2m deep (38.6psia) @21:40:26.15 Cannot pump 0.85ml/s -- Limiting to 0.83ml/s @21:40:26.31 SamplePump.in :sample @21:40:26.39 SamplePump.seek 2000ml,2:47:06 @21:40:28.98 Cartridge 3 filtering 1/2000ml at 0.56ml/s with 24.6psi vacuum 16.0m deep (38.4psia) @21:41:28.99 Cartridge 3 filtering 33/2000ml at 0.53ml/s with 24.9psi vacuum 16.6m deep (39.3psia) @21:42:28.99 Cartridge 3 filtering 64/2000ml at 0.52ml/s with 23.7psi vacuum 18.0m deep (41.3psia) @21:43:28.99 Cartridge 3 filtering 95/2000ml at 0.52ml/s with 26.6psi vacuum 16.5m deep (39.0psia) @21:44:28.99 Cartridge 3 filtering 125/2000ml at 0.49ml/s with 24.6psi vacuum 17.3m deep (40.2psia) @21:45:28.99 Cartridge 3 filtering 155/2000ml at 0.48ml/s with 17.5psi vacuum 19.9m deep (44.1psia) @21:46:28.99 Cartridge 3 filtering 184/2000ml at 0.48ml/s with 26.4psi vacuum 12.5m deep (33.2psia) @21:47:28.99 Cartridge 3 filtering 212/2000ml at 0.48ml/s with 27.5psi vacuum 16.0m deep (38.4psia) @21:48:28.99 Cartridge 3 filtering 239/2000ml at 0.45ml/s with 26.4psi vacuum 13.0m deep (33.9psia) @21:49:28.99 Cartridge 3 filtering 267/2000ml at 0.43ml/s with 25.7psi vacuum 13.7m deep (35.0psia) @21:50:28.99 Cartridge 3 filtering 293/2000ml at 0.44ml/s with 21.4psi vacuum 16.9m deep (39.7psia) @21:51:28.99 Cartridge 3 filtering 319/2000ml at 0.44ml/s with 21.5psi vacuum 17.3m deep (40.3psia) @21:52:28.98 Cartridge 3 filtering 344/2000ml at 0.43ml/s with 27.2psi vacuum 11.0m deep (31.0psia) @21:53:29.35 Cartridge 3 filtering 369/2000ml at 0.39ml/s with 25.0psi vacuum 16.4m deep (39.0psia) @21:54:28.99 Cartridge 3 filtering 394/2000ml at 0.38ml/s with 21.2psi vacuum 13.7m deep (35.0psia) @21:55:28.99 Cartridge 3 filtering 418/2000ml at 0.39ml/s with 26.1psi vacuum 12.9m deep (33.7psia) @21:56:29.00 Cartridge 3 filtering 441/2000ml at 0.37ml/s with 24.9psi vacuum 10.7m deep (30.6psia) @21:57:28.99 Cartridge 3 filtering 464/2000ml at 0.37ml/s with 22.0psi vacuum 12.3m deep (32.9psia) @21:58:28.99 Cartridge 3 filtering 487/2000ml at 0.36ml/s with 23.6psi vacuum 15.3m deep (37.3psia) @21:59:28.99 Cartridge 3 filtering 510/2000ml at 0.39ml/s with 23.1psi vacuum 18.8m deep (42.5psia) @22:00:28.99 Cartridge 3 filtering 532/2000ml at 0.37ml/s with 26.8psi vacuum 16.6m deep (39.2psia) @22:01:28.99 Cartridge 3 filtering 553/2000ml at 0.35ml/s with 20.1psi vacuum 20.8m deep (45.4psia) @22:02:29.00 Cartridge 3 filtering 575/2000ml at 0.34ml/s with 26.7psi vacuum 14.7m deep (36.4psia) @22:03:28.99 Cartridge 3 filtering 596/2000ml at 0.34ml/s with 20.4psi vacuum 20.6m deep (45.1psia) @22:04:28.99 Cartridge 3 filtering 617/2000ml at 0.36ml/s with 24.2psi vacuum 16.8m deep (39.6psia) @22:05:28.99 Cartridge 3 filtering 637/2000ml at 0.36ml/s with 24.5psi vacuum 19.1m deep (42.9psia) @22:06:28.99 Cartridge 3 filtering 657/2000ml at 0.32ml/s with 25.5psi vacuum 15.5m deep (37.7psia) @22:07:28.99 Cartridge 3 filtering 677/2000ml at 0.34ml/s with 27.4psi vacuum 14.5m deep (36.1psia) @22:08:28.99 Cartridge 3 filtering 697/2000ml at 0.31ml/s with 24.5psi vacuum 16.7m deep (39.3psia) @22:09:29.00 Cartridge 3 filtering 716/2000ml at 0.30ml/s with 24.8psi vacuum 13.6m deep (34.8psia) @22:10:28.99 Cartridge 3 filtering 736/2000ml at 0.31ml/s with 26.4psi vacuum 15.7m deep (37.8psia) @22:11:28.99 Cartridge 3 filtering 754/2000ml at 0.30ml/s with 23.9psi vacuum 14.3m deep (35.8psia) @22:12:29.04 Cartridge 3 filtering 773/2000ml at 0.30ml/s with 23.3psi vacuum 11.5m deep (31.6psia) @22:13:29.00 Cartridge 3 filtering 792/2000ml at 0.30ml/s with 26.3psi vacuum 16.4m deep (38.9psia) @22:14:28.99 Cartridge 3 filtering 810/2000ml at 0.31ml/s with 27.4psi vacuum 15.3m deep (37.2psia) @22:15:28.99 Cartridge 3 filtering 828/2000ml at 0.29ml/s with 25.4psi vacuum 16.2m deep (38.7psia) @22:16:28.99 Cartridge 3 filtering 845/2000ml at 0.28ml/s with 27.2psi vacuum 14.5m deep (36.2psia) @22:17:28.99 Cartridge 3 filtering 863/2000ml at 0.29ml/s with 26.6psi vacuum 15.7m deep (37.9psia) @22:18:28.99 Cartridge 3 filtering 880/2000ml at 0.30ml/s with 27.0psi vacuum 16.9m deep (39.7psia) @22:19:28.99 Cartridge 3 filtering 897/2000ml at 0.27ml/s with 22.5psi vacuum 15.1m deep (37.1psia) @22:20:28.99 Cartridge 3 filtering 914/2000ml at 0.30ml/s with 28.2psi vacuum 16.4m deep (39.0psia) @22:21:28.99 Cartridge 3 filtering 931/2000ml at 0.30ml/s with 24.9psi vacuum 16.5m deep (39.1psia) @22:22:28.99 Cartridge 3 filtering 947/2000ml at 0.27ml/s with 27.8psi vacuum 15.2m deep (37.1psia) @22:23:28.99 Cartridge 3 filtering 964/2000ml at 0.26ml/s with 27.0psi vacuum 13.7m deep (34.9psia) @22:24:28.99 Cartridge 3 filtering 980/2000ml at 0.26ml/s with 24.9psi vacuum 17.1m deep (39.9psia) @22:25:28.99 Cartridge 3 filtering 996/2000ml at 0.28ml/s with 26.5psi vacuum 17.6m deep (40.7psia) @22:26:29.00 Cartridge 3 filtering 1012/2000ml at 0.25ml/s with 17.3psi vacuum 20.1m deep (44.3psia) @22:27:28.99 Cartridge 3 filtering 1027/2000ml at 0.24ml/s with 24.8psi vacuum 15.9m deep (38.2psia) @22:28:28.98 Cartridge 3 filtering 1043/2000ml at 0.24ml/s with 24.0psi vacuum 16.4m deep (38.9psia) @22:29:29.36 Cartridge 3 filtering 1058/2000ml at 0.27ml/s with 18.4psi vacuum 21.4m deep (46.3psia) @22:30:28.99 Cartridge 3 filtering 1073/2000ml at 0.26ml/s with 28.1psi vacuum 15.4m deep (37.4psia) @22:31:29.00 Cartridge 3 filtering 1088/2000ml at 0.27ml/s with 16.8psi vacuum 22.3m deep (47.7psia) @22:32:29.00 Cartridge 3 filtering 1103/2000ml at 0.26ml/s with 27.3psi vacuum 16.7m deep (39.4psia) @22:33:28.99 Cartridge 3 filtering 1118/2000ml at 0.23ml/s with 24.1psi vacuum 17.0m deep (39.9psia) @22:34:28.99 Cartridge 3 filtering 1133/2000ml at 0.27ml/s with 25.4psi vacuum 18.4m deep (41.9psia) @22:35:28.99 Cartridge 3 filtering 1147/2000ml at 0.23ml/s with 22.5psi vacuum 11.6m deep (31.9psia) @22:36:29.00 Cartridge 3 filtering 1161/2000ml at 0.23ml/s with 24.9psi vacuum 13.1m deep (34.0psia) @22:37:28.99 Cartridge 3 filtering 1176/2000ml at 0.26ml/s with 25.6psi vacuum 16.7m deep (39.4psia) @22:38:28.99 Cartridge 3 filtering 1190/2000ml at 0.23ml/s with 24.2psi vacuum 16.4m deep (38.9psia) @22:39:28.98 Cartridge 3 filtering 1204/2000ml at 0.23ml/s with 20.9psi vacuum 18.9m deep (42.6psia) @22:40:28.99 Cartridge 3 filtering 1217/2000ml at 0.24ml/s with 17.7psi vacuum 22.1m deep (47.4psia) @22:41:28.98 Cartridge 3 filtering 1231/2000ml at 0.22ml/s with 23.7psi vacuum 16.7m deep (39.4psia) @22:42:28.99 Cartridge 3 filtering 1245/2000ml at 0.22ml/s with 25.9psi vacuum 15.8m deep (38.0psia) @22:43:28.99 Cartridge 3 filtering 1258/2000ml at 0.23ml/s with 14.7psi vacuum 21.7m deep (46.8psia) @22:44:28.99 Cartridge 3 filtering 1271/2000ml at 0.22ml/s with 26.5psi vacuum 16.8m deep (39.5psia) @22:45:28.99 Cartridge 3 filtering 1285/2000ml at 0.22ml/s with 15.2psi vacuum 19.0m deep (42.8psia) @22:46:28.99 Cartridge 3 filtering 1298/2000ml at 0.21ml/s with 23.7psi vacuum 14.2m deep (35.7psia) @22:47:28.99 Cartridge 3 filtering 1311/2000ml at 0.20ml/s with 23.4psi vacuum 17.3m deep (40.2psia) @22:48:29.00 Cartridge 3 filtering 1324/2000ml at 0.20ml/s with 24.6psi vacuum 16.1m deep (38.5psia) @22:49:28.99 Cartridge 3 filtering 1337/2000ml at 0.23ml/s with 24.4psi vacuum 19.1m deep (42.9psia) @22:50:28.99 Cartridge 3 filtering 1350/2000ml at 0.20ml/s with 26.8psi vacuum 14.9m deep (36.8psia) @22:51:28.99 Cartridge 3 filtering 1362/2000ml at 0.20ml/s with 23.6psi vacuum 12.2m deep (32.7psia) @22:52:28.99 Cartridge 3 filtering 1375/2000ml at 0.21ml/s with 22.7psi vacuum 11.5m deep (31.8psia) @22:53:28.99 Cartridge 3 filtering 1388/2000ml at 0.20ml/s with 27.2psi vacuum 15.9m deep (38.2psia) @22:54:28.99 Cartridge 3 filtering 1400/2000ml at 0.20ml/s with 26.3psi vacuum 15.5m deep (37.6psia) @22:55:28.99 Cartridge 3 filtering 1413/2000ml at 0.22ml/s with 15.9psi vacuum 22.8m deep (48.4psia) @22:56:28.99 Cartridge 3 filtering 1425/2000ml at 0.20ml/s with 27.4psi vacuum 15.0m deep (36.9psia) @22:57:28.99 Cartridge 3 filtering 1438/2000ml at 0.20ml/s with 27.4psi vacuum 15.7m deep (37.9psia) @22:58:28.99 Cartridge 3 filtering 1450/2000ml at 0.20ml/s with 23.6psi vacuum 11.5m deep (31.7psia) @22:59:29.00 Cartridge 3 filtering 1463/2000ml at 0.20ml/s with 25.2psi vacuum 17.3m deep (40.3psia) @23:00:28.99 Cartridge 3 filtering 1475/2000ml at 0.20ml/s with 26.4psi vacuum 16.9m deep (39.7psia) @23:01:26.52 Flow averaged 0.31ml/s over 1:21:01 @23:01:26.56 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @23:01:27.15 Relieved excess vacuum in .6 seconds @23:01:27.18 SamplePump.seek 2000ml,43:15 @23:01:28.98 Cartridge 3 filtering 1487/2000ml at 0.20ml/s with 25.8psi vacuum 17.0m deep (39.8psia) @23:02:29.36 Cartridge 3 filtering 1500/2000ml at 0.20ml/s with 26.3psi vacuum 16.4m deep (38.9psia) @23:03:29.00 Cartridge 3 filtering 1512/2000ml at 0.20ml/s with 27.9psi vacuum 15.7m deep (37.9psia) @23:04:12.45 Flow averaged 0.21ml/s over 2:46 @23:04:12.49 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @23:04:13.07 Relieved excess vacuum in .6 seconds @23:04:13.10 SamplePump.seek 2000ml,40:25 @23:04:28.98 Cartridge 3 filtering 1524/2000ml at 0.20ml/s with 24.8psi vacuum 17.3m deep (40.2psia) @23:05:28.99 Cartridge 3 filtering 1536/2000ml at 0.20ml/s with 26.3psi vacuum 16.1m deep (38.6psia) @23:06:28.99 Cartridge 3 filtering 1549/2000ml at 0.21ml/s with 18.2psi vacuum 21.1m deep (45.9psia) @23:06:43.28 Flow averaged 0.21ml/s over 2:31 @23:06:43.32 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @23:06:43.91 Relieved excess vacuum in .6 seconds @23:06:43.94 SamplePump.seek 2000ml,37:50 @23:07:28.98 Cartridge 3 filtering 1561/2000ml at 0.20ml/s with 26.8psi vacuum 17.4m deep (40.4psia) @23:08:24.52 Flow averaged 0.21ml/s over 1:41 @23:08:24.56 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @23:08:25.15 Relieved excess vacuum in .6 seconds @23:08:25.18 SamplePump.seek 2000ml,36:07 @23:08:28.98 Cartridge 3 filtering 1573/2000ml at 0.20ml/s with 24.8psi vacuum 17.5m deep (40.6psia) @23:09:28.99 Cartridge 3 filtering 1586/2000ml at 0.20ml/s with 26.1psi vacuum 17.0m deep (39.8psia) @23:10:11.96 Flow averaged 0.21ml/s over 1:47 @23:10:12.01 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @23:10:12.59 Relieved excess vacuum in .6 seconds @23:10:12.62 SamplePump.seek 2000ml,34:17 @23:10:28.98 Cartridge 3 filtering 1598/2000ml at 0.20ml/s with 26.0psi vacuum 16.8m deep (39.5psia) @23:11:24.27 Flow averaged 0.21ml/s over 1:12 @23:11:24.32 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @23:11:24.91 Relieved excess vacuum in .6 seconds @23:11:24.94 SamplePump.seek 2000ml,33:03 @23:11:28.98 Cartridge 3 filtering 1610/2000ml at 0.20ml/s with 26.3psi vacuum 16.0m deep (38.3psia) @23:12:19.93 Flow averaged 0.20ml/s over 55 seconds @23:12:19.97 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @23:12:20.56 Relieved excess vacuum in .6 seconds @23:12:20.58 SamplePump.seek 2000ml,32:07 @23:12:28.98 Cartridge 3 filtering 1622/2000ml at 0.20ml/s with 26.7psi vacuum 15.9m deep (38.2psia) @23:13:05.39 Flow averaged 0.20ml/s over 45 seconds @23:13:05.42 Waiting up to 8 seconds for vacuum to reduce from 26.0 to 18.0psi @23:13:06.01 Relieved excess vacuum in .6 seconds @23:13:06.04 SamplePump.seek 2000ml,31:21 @23:13:28.99 Cartridge 3 filtering 1634/2000ml at 0.21ml/s with 21.5psi vacuum 19.0m deep (42.8psia) @23:13:53.26 Flow averaged 0.20ml/s over 48 seconds @23:13:53.30 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @23:13:53.89 Relieved excess vacuum in .6 seconds @23:13:53.92 SamplePump.seek 2000ml,30:33 @23:14:28.98 Cartridge 3 filtering 1646/2000ml at 0.20ml/s with 26.8psi vacuum 15.9m deep (38.2psia) @23:14:51.63 Flow averaged 0.20ml/s over 58 seconds @23:14:51.69 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @23:14:52.27 Relieved excess vacuum in .6 seconds @23:14:52.30 SamplePump.seek 2000ml,29:34 @23:15:24.57 Flow averaged 0.20ml/s over 33 seconds @23:15:24.61 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @23:15:25.20 Relieved excess vacuum in .6 seconds @23:15:25.23 SamplePump.seek 2000ml,29:01 @23:15:28.98 Cartridge 3 filtering 1658/2000ml at 0.20ml/s with 25.9psi vacuum 17.1m deep (39.9psia) @23:16:09.46 Flow averaged 0.21ml/s over 45 seconds @23:16:09.51 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @23:16:10.10 Relieved excess vacuum in .6 seconds @23:16:10.13 SamplePump.seek 2000ml,28:16 @23:16:28.98 Cartridge 3 filtering 1671/2000ml at 0.20ml/s with 26.7psi vacuum 16.3m deep (38.8psia) @23:16:56.00 Flow averaged 0.20ml/s over 46 seconds @23:16:56.04 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @23:16:56.63 Relieved excess vacuum in .6 seconds @23:16:56.66 SamplePump.seek 2000ml,27:29 @23:17:28.99 Cartridge 3 filtering 1683/2000ml at 0.20ml/s with 26.6psi vacuum 17.0m deep (39.8psia) @23:17:32.43 Flow averaged 0.20ml/s over 36 seconds @23:17:32.48 Waiting up to 9 seconds for vacuum to reduce from 26.5 to 18.0psi @23:17:33.06 Relieved excess vacuum in .6 seconds @23:17:33.09 SamplePump.seek 2000ml,26:52 @23:17:56.45 Flow averaged 0.20ml/s over 24 seconds @23:17:56.49 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @23:17:57.08 Relieved excess vacuum in .6 seconds @23:17:57.11 SamplePump.seek 2000ml,26:29 @23:18:18.43 Flow averaged 0.20ml/s over 22 seconds @23:18:18.48 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @23:18:19.06 Relieved excess vacuum in .6 seconds @23:18:19.09 SamplePump.seek 2000ml,26:07 @23:18:28.98 Cartridge 3 filtering 1695/2000ml at 0.20ml/s with 26.5psi vacuum 16.5m deep (39.1psia) @23:18:48.98 Flow averaged 0.20ml/s over 30 seconds @23:18:49.02 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @23:18:49.60 Relieved excess vacuum in .6 seconds @23:18:49.63 SamplePump.seek 2000ml,25:36 @23:19:27.45 Flow averaged 0.20ml/s over 38 seconds @23:19:27.49 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @23:19:28.08 Relieved excess vacuum in .6 seconds @23:19:28.11 SamplePump.seek 2000ml,24:58 @23:19:28.98 Cartridge 3 filtering 1706/2000ml at 0.20ml/s with 26.9psi vacuum 16.5m deep (39.1psia) @23:19:40.93 Flow averaged 0.20ml/s over 13 seconds @23:19:40.97 Waiting up to 10 seconds for vacuum to reduce from 26.7 to 18.0psi @23:19:41.93 Relieved excess vacuum in 1 second @23:19:41.96 SamplePump.seek 2000ml,24:45 @23:20:11.84 Flow averaged 0.20ml/s over 30 seconds @23:20:11.88 Waiting up to 8 seconds for vacuum to reduce from 26.1 to 18.0psi @23:20:12.48 Relieved excess vacuum in .6 seconds @23:20:12.51 SamplePump.seek 2000ml,24:15 @23:20:28.42 Flow averaged 0.20ml/s over 16 seconds @23:20:28.46 Waiting up to 9 seconds for vacuum to reduce from 26.3 to 18.0psi @23:20:28.99 Cartridge 3 filtering 1718/2000ml at 0.00ml/s with -0.2psi vacuum 16.4m deep (39.0psia) @23:20:29.08 Relieved excess vacuum in .7 seconds @23:20:29.11 SamplePump.seek 2000ml,23:59 @23:20:46.97 Flow averaged 0.20ml/s over 18 seconds @23:20:47.02 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @23:20:47.60 Relieved excess vacuum in .6 seconds @23:20:47.63 SamplePump.seek 2000ml,23:41 @23:21:06.42 Flow averaged 0.20ml/s over 19 seconds @23:21:06.47 Waiting up to 10 seconds for vacuum to reduce from 26.8 to 18.0psi @23:21:07.05 Relieved excess vacuum in .6 seconds @23:21:07.08 SamplePump.seek 2000ml,23:22 @23:21:28.99 Cartridge 3 filtering 1730/2000ml at 0.20ml/s with 26.4psi vacuum 17.1m deep (39.9psia) @23:21:29.82 Flow averaged 0.20ml/s over 23 seconds @23:21:29.86 Waiting up to 9 seconds for vacuum to reduce from 26.2 to 18.0psi @23:21:30.46 Relieved excess vacuum in .6 seconds @23:21:30.48 SamplePump.seek 2000ml,22:59 @23:21:47.52 Flow averaged 0.20ml/s over 18 seconds @23:21:47.57 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @23:21:48.15 Relieved excess vacuum in .6 seconds @23:21:48.18 SamplePump.seek 2000ml,22:41 @23:22:10.52 Flow averaged 0.20ml/s over 23 seconds @23:22:10.57 Waiting up to 10 seconds for vacuum to reduce from 26.6 to 18.0psi @23:22:11.15 Relieved excess vacuum in .6 seconds @23:22:11.18 SamplePump.seek 2000ml,22:19 @23:22:25.00 Flow averaged 0.20ml/s over 14 seconds @23:22:25.03 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @23:22:25.62 Relieved excess vacuum in .6 seconds @23:22:25.65 SamplePump.seek 2000ml,22:05 @23:22:28.98 Cartridge 3 filtering 1742/2000ml at 0.20ml/s with 25.9psi vacuum 17.1m deep (40.0psia) @23:22:38.61 Flow averaged 0.20ml/s over 13 seconds @23:22:38.65 Waiting up to 9 seconds for vacuum to reduce from 26.6 to 18.0psi @23:22:39.23 Relieved excess vacuum in .6 seconds @23:22:39.26 SamplePump.seek 2000ml,21:52 @23:22:48.50 Flow averaged 0.20ml/s over 10 seconds @23:22:48.52 Intake.close @23:22:48.60 Exhaust.close @23:22:48.80 Toroid.in :hold @23:22:48.87 Toroid.seek :bypass @23:22:50.53 Toroid.in :default @23:22:50.61 Toroid.seek :clear @23:22:52.59 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @23:22:52.61 Pressure.stop @23:22:52.82 Sampled 1745.4ml @23:22:54.76 -> Cmd.startProcessing @23:22:55.25 Plunge.seek :reagent @23:22:56.15 Sample loop closed. Ready to Deliver Reagents @23:22:56.17 Archive.seek :sealed @23:22:59.83 Archive.seek :evac @23:23:13.84 delay 1:00 @23:24:13.87 Archive.seek :clear @23:24:31.05 Sample preserved. Puck Full. @23:24:32.13 -> Cmd.stop @23:24:32.23 Carousel.in :default @23:24:32.34 Carousel.home.seek 3 @23:24:32.66 Plunge.seek :locked @23:24:33.74 Air.in :unlocking @23:24:33.88 Lysis1.in :unlocking @23:24:33.92 Air.seek :clear @23:24:34.06 Lysis1.seek :clear @23:24:35.33 Gate.power :motor,:OFF @23:24:35.35 Gate.power :core,:OFF @23:24:35.37 Gate.power :analytic1,:OFF @23:24:35.39 Gate.power :analytic2,:OFF @23:24:35.42 Gate.power :analytic3,:OFF @23:24:35.45 Gate.power :main,:OFF @23:24:35.47 Safely stopped and ready to power off