##-- file opened 2019-05-09T23:37:07.528Z @16:37:08.50 -> showStatus @16:37:10.11 -> Cmd.loadCartridge @16:37:10.30 Gate.power :main,:ON,limit to 5000mA @16:37:10.32 Gate.power :analytic1,:ON,limit to 5000mA @16:37:10.35 Gate.power :analytic2,:ON,limit to 5000mA @16:37:10.39 Gate.power :analytic3,:ON,limit to 5000mA @16:37:10.48 Powering core bus @16:37:12.84 Archive.configure :default @16:37:13.01 Air.configure :default @16:37:13.18 Lysis1.configure :default @16:37:13.35 Lysis2.configure :default @16:37:13.51 Plunge.configure :default @16:37:13.70 SamplePump.configure :default @16:37:13.88 ExtraPump.configure :default @16:37:14.07 Toroid.configure :default @16:37:14.27 Carousel.configure :default @16:37:14.46 Pressure.configure :default @16:37:14.55 All elf controllers running firmware version 4.56 @16:37:14.59 Gate.power :motor,:ON,limit to 5000mA @16:37:14.78 Archive.reconfigure :default @16:37:15.19 Archive.home.jog 0 @16:37:15.48 Lysis2.reconfigure :default @16:37:15.57 Lysis1.reconfigure :default @16:37:15.61 Toroid.reconfigure :default @16:37:15.68 Plunge.reconfigure :default @16:37:15.73 Air.reconfigure :default @16:37:16.03 Lysis2.home.jog 0 @16:37:16.06 Lysis1.home.jog 0 @16:37:16.10 Toroid.home.jog 0 @16:37:16.17 Plunge.home.jog 0 @16:37:16.20 Air.home.jog 0 @16:37:16.67 Archive.reconfigure :homing @16:37:17.00 Archive.jog 1365 @16:37:17.22 Toroid.reconfigure :homing @16:37:17.28 Plunge.reconfigure :homing @16:37:17.32 Lysis1.reconfigure :homing @16:37:17.39 Lysis2.reconfigure :homing @16:37:17.45 Air.reconfigure :homing @16:37:17.70 Plunge.jog 746 @16:37:17.77 Toroid.jog 609 @16:37:18.44 Lysis2.jog 907 @16:37:18.53 Air.jog 1926 @16:37:18.58 Lysis1.jog 1352 @16:37:18.81 Plunge.setRawPosition! 50 @16:37:18.84 Archive.setRawPosition! 50 @16:37:18.95 Plunge.seek :home @16:37:19.01 Archive.seek :home @16:37:19.42 Plunge.reconfigure :default @16:37:19.53 Archive.reconfigure :default @16:37:19.65 Lysis2.setRawPosition! 50 @16:37:19.72 Lysis2.seek :home @16:37:19.86 Lysis1.setRawPosition! 50 @16:37:19.95 Lysis1.seek :home @16:37:20.12 Toroid.setRawPosition! 0 @16:37:20.16 Lysis2.reconfigure :default @16:37:20.19 Air.setRawPosition! 50 @16:37:20.36 Toroid.seek :home @16:37:20.44 Air.seek :home @16:37:20.71 Toroid.reconfigure :default @16:37:20.75 Lysis1.reconfigure :default @16:37:20.96 Air.reconfigure :default @16:37:21.38 Toroid.seek :clear @16:37:23.04 Carousel.reconfigure :default @16:37:23.13 Carousel.home.jog 0 @16:37:23.68 Carousel.seek 55 @16:37:23.93 Selecting Cartridge 18 @16:37:24.23 Carousel.seek 18 @16:37:32.16 Lysis2.seek :locked @16:37:32.36 Plunge.seek :locked @16:37:32.56 Air.seek :locked @16:37:42.79 -> Cmd.startFiltering @16:37:43.15 Duration of filtering limited to 2:05:00 @16:37:43.63 Priming sample loop w/100ml, bypass w/10ml @16:37:43.65 SamplePump.setPosition! 0ml @16:37:43.74 Bypass.open @16:37:45.27 Intake.open @16:37:46.05 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @16:37:49.08 Vacuum tare is 39% of full scale @16:37:49.27 Pressure.reconfigure :default @16:37:49.36 Pressure.hold @16:37:49.64 SamplePump.reconfigure :prime @16:37:49.76 SamplePump.seek 10ml,1:21 @16:38:01.00 Pressure.coast @16:38:01.09 SamplePump.setPosition! 0ml @16:38:01.17 Exhaust.open @16:38:02.63 Bypass.close @16:38:04.26 Pressure.reconfigure :default @16:38:04.35 Pressure.hold @16:38:04.71 SamplePump.reconfigure :prime @16:38:04.80 SamplePump.seek 100ml,8:51 @16:39:53.16 Pressure.coast @16:39:53.25 Bypass.open @16:39:54.01 Intake.close @16:39:54.80 Toroid.reconfigure :hold @16:39:54.89 Toroid.seek :crack @16:39:55.86 Toroid.reconfigure :default @16:39:55.93 Toroid.seek :clear @16:39:57.68 Toroid.reconfigure :hold @16:39:57.78 Toroid.seek :cartridge @16:39:59.62 Toroid.reconfigure :default @16:39:59.72 Toroid.seek :clear @16:40:01.82 Pressurizing cartridge to 26psi above 13.6psia @16:40:01.84 SamplePump.setPosition! 0ml @16:40:01.92 Intake.open @16:40:02.64 Bypass.close @16:40:03.37 Exhaust.close @16:40:04.24 Pressure.reconfigure :default @16:40:04.32 Pressure.hold @16:40:04.61 SamplePump.reconfigure :charge @16:40:04.72 SamplePump.seek 2.3ml,42 seconds @16:40:12.35 Pressure.coast @16:40:12.50 Intake.close @16:40:13.21 Pressurized cartridge with 0.258ml to 26.0psi @16:40:13.23 Isolated @38.8psia (25.2psi) @16:40:13.25 Checking for cartridge leaks from 38.8psia @16:40:13.34 Waiting up to 20 seconds for cartridge pressure to stabilize +/-0.75psi @16:40:18.75 Cartridge pressure fell 6% to 36.6psia @16:40:18.87 Sampling 1000.0ml @16:40:18.88 SamplePump.setPosition! 0ml @16:40:18.98 Exhaust.open @16:40:19.70 Intake.open @16:40:21.13 Pressure.reconfigure :default @16:40:21.24 Pressure.hold @16:40:21.59 SamplePump.reconfigure :sample @16:40:21.69 SamplePump.seek 1000ml,1:23:53 @16:40:23.65 Cartridge 18 sampling 1/1000ml at 0.55ml/s with 16.1psi vacuum @16:41:23.66 Cartridge 18 sampling 34/1000ml at 0.55ml/s with 16.8psi vacuum @16:42:23.67 Cartridge 18 sampling 67/1000ml at 0.55ml/s with 17.1psi vacuum @16:43:23.66 Cartridge 18 sampling 100/1000ml at 0.55ml/s with 17.6psi vacuum @16:44:23.66 Cartridge 18 sampling 133/1000ml at 0.55ml/s with 16.8psi vacuum @16:45:23.67 Cartridge 18 sampling 166/1000ml at 0.55ml/s with 16.9psi vacuum @16:46:23.67 Cartridge 18 sampling 199/1000ml at 0.55ml/s with 17.0psi vacuum @16:47:23.67 Cartridge 18 sampling 232/1000ml at 0.55ml/s with 17.6psi vacuum @16:48:23.66 Cartridge 18 sampling 265/1000ml at 0.55ml/s with 18.4psi vacuum @16:49:23.66 Cartridge 18 sampling 298/1000ml at 0.55ml/s with 16.0psi vacuum @16:50:23.67 Cartridge 18 sampling 331/1000ml at 0.55ml/s with 14.9psi vacuum @16:51:23.69 Cartridge 18 sampling 364/1000ml at 0.55ml/s with 14.6psi vacuum @16:52:23.66 Cartridge 18 sampling 397/1000ml at 0.55ml/s with 15.2psi vacuum @16:53:23.67 Cartridge 18 sampling 430/1000ml at 0.55ml/s with 13.6psi vacuum @16:54:23.66 Cartridge 18 sampling 463/1000ml at 0.55ml/s with 16.1psi vacuum @16:55:23.65 Cartridge 18 sampling 496/1000ml at 0.55ml/s with 15.9psi vacuum @16:56:23.66 Cartridge 18 sampling 529/1000ml at 0.55ml/s with 16.4psi vacuum @16:57:23.66 Cartridge 18 sampling 563/1000ml at 0.55ml/s with 18.1psi vacuum @16:58:23.67 Cartridge 18 sampling 596/1000ml at 0.55ml/s with 13.3psi vacuum @16:59:22.27 SamplePump.coast @16:59:22.36 Intake.close @16:59:22.44 Exhaust.close @16:59:22.69 Toroid.reconfigure :hold @16:59:22.78 Toroid.seek :bypass @16:59:23.65 Cartridge 18 sampling 628/1000ml at 0.00ml/s with 0.0psi vacuum @16:59:24.45 Toroid.reconfigure :default @16:59:24.54 Toroid.seek :clear @16:59:26.20 Pressure.coast @16:59:26.58 Cartridge::Sampler::LowPressure in FILTERING -- Serious Leak or Stall -- 0.55ml/s made only 16.8psi vacuum @16:59:26.60 Retry #1 of 2 @16:59:26.63 Selecting Cartridge 17 @16:59:27.05 Air.seek :clear @16:59:30.86 Lysis2.seek :clear @16:59:31.08 Plunge.seek :clear @16:59:32.80 Carousel.seek 17 @16:59:33.41 Lysis2.seek :locked @16:59:33.61 Plunge.seek :locked @16:59:33.84 Air.seek :locked @16:59:37.53 Duration of filtering limited to 2:05:00 @16:59:37.99 Priming sample loop w/100ml, bypass w/10ml @16:59:38.01 SamplePump.setPosition! 0ml @16:59:38.09 Bypass.open @16:59:39.62 Intake.open @16:59:40.42 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @16:59:43.42 Vacuum tare is 39% of full scale @16:59:43.62 Pressure.reconfigure :default @16:59:43.71 Pressure.hold @16:59:44.00 SamplePump.reconfigure :prime @16:59:44.09 SamplePump.seek 10ml,1:21 @16:59:55.32 Pressure.coast @16:59:55.39 SamplePump.setPosition! 0ml @16:59:55.47 Exhaust.open @16:59:56.91 Bypass.close @16:59:58.51 Pressure.reconfigure :default @16:59:58.60 Pressure.hold @16:59:58.93 SamplePump.reconfigure :prime @16:59:59.03 SamplePump.seek 100ml,8:51 @17:01:47.27 Pressure.coast @17:01:47.36 Bypass.open @17:01:48.09 Intake.close @17:01:48.82 Toroid.reconfigure :hold @17:01:48.91 Toroid.seek :crack @17:01:49.87 Toroid.reconfigure :default @17:01:49.96 Toroid.seek :clear @17:01:51.74 Toroid.reconfigure :hold @17:01:51.82 Toroid.seek :cartridge @17:01:53.67 Toroid.reconfigure :default @17:01:53.77 Toroid.seek :clear @17:01:56.43 Pressurizing cartridge to 26psi above 13.7psia @17:01:56.46 SamplePump.setPosition! 0ml @17:01:56.54 Intake.open @17:01:57.27 Bypass.close @17:01:57.97 Exhaust.close @17:01:58.87 Pressure.reconfigure :default @17:01:58.96 Pressure.hold @17:01:59.23 SamplePump.reconfigure :charge @17:01:59.33 SamplePump.seek 2.3ml,42 seconds @17:02:05.64 Pressure.coast @17:02:05.81 Intake.close @17:02:06.50 Pressurized cartridge with 0.175ml to 26.1psi @17:02:06.53 Isolated @39.1psia (25.4psi) @17:02:06.55 Checking for cartridge leaks from 39.1psia @17:02:06.60 Waiting up to 20 seconds for cartridge pressure to stabilize +/-0.75psi @17:02:11.97 Cartridge pressure fell 7% to 36.4psia @17:02:12.08 Sampling 1000.0ml @17:02:12.10 SamplePump.setPosition! 0ml @17:02:12.19 Exhaust.open @17:02:12.92 Intake.open @17:02:13.80 Pressure.reconfigure :default @17:02:13.89 Pressure.hold @17:02:14.24 SamplePump.reconfigure :sample @17:02:14.34 SamplePump.seek 1000ml,1:23:53 @17:02:16.86 Cartridge 17 sampling 1/1000ml at 0.55ml/s with 18.4psi vacuum @17:03:16.87 Cartridge 17 sampling 34/1000ml at 0.55ml/s with 16.5psi vacuum @17:04:16.88 Cartridge 17 sampling 67/1000ml at 0.55ml/s with 15.8psi vacuum @17:05:16.88 Cartridge 17 sampling 100/1000ml at 0.55ml/s with 15.0psi vacuum @17:06:16.87 Cartridge 17 sampling 133/1000ml at 0.55ml/s with 17.7psi vacuum @17:07:16.89 Cartridge 17 sampling 166/1000ml at 0.55ml/s with 17.0psi vacuum @17:08:16.87 Cartridge 17 sampling 199/1000ml at 0.55ml/s with 17.8psi vacuum @17:09:16.88 Cartridge 17 sampling 232/1000ml at 0.55ml/s with 18.1psi vacuum @17:10:16.87 Cartridge 17 sampling 266/1000ml at 0.55ml/s with 16.2psi vacuum @17:11:16.87 Cartridge 17 sampling 299/1000ml at 0.55ml/s with 15.3psi vacuum @17:12:16.97 Cartridge 17 sampling 332/1000ml at 0.55ml/s with 15.7psi vacuum @17:13:16.88 Cartridge 17 sampling 365/1000ml at 0.55ml/s with 17.2psi vacuum @17:14:16.87 Cartridge 17 sampling 398/1000ml at 0.55ml/s with 17.0psi vacuum @17:15:16.87 Cartridge 17 sampling 431/1000ml at 0.55ml/s with 18.7psi vacuum @17:16:16.88 Cartridge 17 sampling 464/1000ml at 0.55ml/s with 15.2psi vacuum @17:17:16.88 Cartridge 17 sampling 497/1000ml at 0.55ml/s with 15.3psi vacuum @17:18:16.88 Cartridge 17 sampling 530/1000ml at 0.55ml/s with 15.5psi vacuum @17:19:16.88 Cartridge 17 sampling 563/1000ml at 0.55ml/s with 12.9psi vacuum @17:20:16.86 Cartridge 17 sampling 596/1000ml at 0.55ml/s with 15.6psi vacuum @17:21:16.87 Cartridge 17 sampling 629/1000ml at 0.55ml/s with 16.2psi vacuum @17:22:16.89 Cartridge 17 sampling 662/1000ml at 0.55ml/s with 16.4psi vacuum @17:23:16.87 Cartridge 17 sampling 695/1000ml at 0.55ml/s with 18.3psi vacuum @17:24:16.88 Cartridge 17 sampling 728/1000ml at 0.55ml/s with 12.9psi vacuum @17:25:16.87 Cartridge 17 sampling 762/1000ml at 0.55ml/s with 14.4psi vacuum @17:26:16.88 Cartridge 17 sampling 795/1000ml at 0.55ml/s with 12.9psi vacuum @17:27:16.88 Cartridge 17 sampling 828/1000ml at 0.55ml/s with 16.7psi vacuum @17:28:16.87 Cartridge 17 sampling 861/1000ml at 0.55ml/s with 14.8psi vacuum @17:29:16.92 Cartridge 17 sampling 894/1000ml at 0.55ml/s with 16.8psi vacuum @17:30:16.88 Cartridge 17 sampling 927/1000ml at 0.55ml/s with 14.5psi vacuum @17:31:16.87 Cartridge 17 sampling 960/1000ml at 0.55ml/s with 13.4psi vacuum @17:32:16.87 Cartridge 17 sampling 993/1000ml at 0.55ml/s with 12.6psi vacuum @17:32:29.39 Pressure.coast @17:32:29.59 Intake.close @17:32:29.67 Exhaust.close @17:32:29.90 Toroid.reconfigure :hold @17:32:29.98 Toroid.seek :bypass @17:32:31.65 Toroid.reconfigure :default @17:32:31.74 Toroid.seek :clear @17:32:33.40 Sampled 1000.0ml @17:32:34.83 -> Cmd.startProcessing @17:32:35.25 Plunge.seek :reagent @17:32:36.19 Sample loop closed. Ready to Deliver Reagents @17:32:36.21 Archive.seek :sealed @17:32:39.93 Archive.seek :evac @17:32:53.96 delay 20 seconds @17:33:14.01 Archive.seek :clear @17:33:31.18 RNAlater soak for 10:00 @17:43:31.22 Archive.seek :tVent @17:43:32.90 delay 1 second @17:43:33.94 Archive.seek :evac @17:43:49.94 delay 10 seconds @17:43:59.97 Sample preserved and evacuated @17:44:01.09 -> Cmd.stop @17:44:01.31 Plunge.seek :locked @17:44:02.41 Archive.seek :clear @17:44:03.18 Air.seek :clear @17:44:03.47 Lysis2.seek :clear @17:44:20.20 Archive.coast @17:44:20.33 Air.coast @17:44:20.47 Lysis1.coast @17:44:20.54 Lysis2.coast @17:44:20.62 Plunge.coast @17:44:20.71 SamplePump.coast @17:44:20.78 Toroid.coast @17:44:20.87 Carousel.coast @17:44:21.10 Gate.power :motor,:OFF @17:44:21.12 Gate.power :core,:OFF @17:44:21.15 Gate.power :analytic1,:OFF @17:44:21.19 Gate.power :analytic2,:OFF @17:44:21.22 Gate.power :analytic3,:OFF @17:44:21.25 Gate.power :main,:OFF @17:44:21.28 Safely stopped and ready to power off ##-- file closed 2019-05-10T00:50:57.608Z