2017-09-11T23:32:32.900Z,1505172752.900 [Supervisor](IMPORTANT): Reading configuration overrides from Data/persisted.cfg 2017-09-11T23:32:39.784Z,1505172759.784 [SBIT](IMPORTANT): git: 2017-08-02-81-g2dedf71 2017-09-11T23:32:42.016Z,1505172762.016 [BuoyancyServo](FAULT): Buoyancy failed to initialize 2017-09-11T23:33:50.788Z,1505172830.788 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:14:48 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:33:51.489Z,1505172831.489 [SBIT](IMPORTANT): Beginning Startup BIT 2017-09-11T23:33:51.502Z,1505172831.502 [CBIT](IMPORTANT): Beginning ground fault scan 2017-09-11T23:34:01.863Z,1505172841.863 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): 4.657929 CHAN A1 (24V): 0.027287 CHAN A2 (12V): -0.002819 CHAN A3 (5V): -0.000495 CHAN B0 (3.3V): 0.000187 CHAN B1 (3.15aV): 0.000199 CHAN B2 (3.15bV): 0.000602 CHAN B3 (GND): -0.000253 OPEN: -0.000127 Full Scale Calc: 4.765 mA, -1.589 mA 2017-09-11T23:34:45.389Z,1505172885.389 [SBIT](IMPORTANT): SBIT PASSED 2017-09-11T23:34:45.791Z,1505172885.791 [MissionManager](IMPORTANT): Started mission Startup 2017-09-11T23:35:04.934Z,1505172904.934 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:16:02 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:36:12.688Z,1505172972.688 [MissionManager](IMPORTANT): Started mission Default 2017-09-11T23:36:18.803Z,1505172978.803 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:17:16 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:37:32.595Z,1505173052.595 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:18:30 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:37:56.187Z,1505173076.187 [NAL9602](FAULT): MT Queue status failed to be acquired within timeout. Will not retry this session. 2017-09-11T23:38:46.608Z,1505173126.608 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:19:43 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:40:00.578Z,1505173200.578 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:20:57 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:41:14.272Z,1505173274.272 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:22:11 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:42:30.437Z,1505173350.437 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:23:25 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:42:30.575Z,1505173350.575 [CBIT](CRITICAL): Communications Fault in component: DAT 2017-09-11T23:42:30.831Z,1505173350.831 [CommandLine](FAULT): Scheduling is paused 2017-09-11T23:43:27.069Z,1505173407.069 [Default:CheckIn:E](IMPORTANT): Default mission has been running for 7.232821 min 2017-09-11T23:44:13.994Z,1505173453.994 [NAL9602](FAULT): received: +CSQ:0 OK5, 2, 0, 0, 0 OK 2017-09-11T23:48:41.759Z,1505173721.759 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:29:39 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:49:57.211Z,1505173797.211 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:30:54 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:51:11.076Z,1505173871.076 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:32:08 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:52:24.767Z,1505173944.767 [DAT](FAULT): failed to initialize; deviceResponse_ loaded: Teledyne Benthos ATM-900 Series MF Frequency Band Directional Acoustic Transponder version 8.3.1 Jan 3 2000 02:33:22 Warning battery low CONNECT, available: 02400 bits/sec 1 of 4 user:1>œQ@ 2017-09-11T23:52:50.540Z,1505173970.540 [CommandLine](IMPORTANT): got command quit