//////////////////////////////////////////////////////////////// // // PURPOSE: This contains ControlModule parameters for lrauv-daphne. // // NOTES: All values (except "strings") must be followed by // a unit abbreviation (or one of the unit-like // abbreviations: n/a, bool, enum, count). // //////////////////////////////////////////////////////////////// VerticalControl.buoyancyNeutral = 350.0 cc; // Amount of oil stored in the bladder when the vehicle is neutral VerticalControl.buoyancyPumpDepth = 90.0 m; // Depth must be <= this value in order to safely pump VerticalControl.massDefault = -3 mm; // Position of mass at pitch=0 at neutral buoyancy VerticalControl.massPositionLimitFwd = 17 mm; // max offset forward of center VerticalControl.massPositionLimitAft = -35 mm; // max offset aft of center // Modified settings for use when Turbulence sensor is installed: // VerticalControl.massPositionLimitFwd = 30 mm; // max offset forward of center // VerticalControl.massPositionLimitAft = -30 mm; // max offset aft of center // VerticalControl.maxDiveRate = 0.300 m/s; // Maximum dive rate at pitchLimit and 1 m/s