##-- file opened 2018-01-29T06:44:01.527Z --## @22:41:02.80 -> showStatus @22:41:04.40 -> Cmd.loadCartridge @22:41:04.44 Powering core bus @22:41:07.13 ArS.configure ArSconfig @22:41:07.23 LyS1.configure LyS1config @22:41:07.35 LyS2.configure LyS2config @22:41:07.45 AirS.configure AirSconfig @22:41:07.57 TV.configure TVconfig @22:41:07.69 SP.configure SPconfig @22:41:07.81 Sea.configure SPconfig @22:41:07.95 SC.configure SCconfig @22:41:08.07 PV.configure PVconfig @22:41:08.13 All elf controllers running firmware version 4.41 @22:41:08.14 Gate.power :main,:ON,limit to 5000mA @22:41:08.16 Gate.power :motor,:ON,limit to 5000mA @22:41:08.24 Intake.close @22:41:08.29 PB.close @22:41:08.33 Exhaust.close @22:41:10.06 TV.reconfigure TVconfig @22:41:10.12 AirS.reconfigure AirSconfig @22:41:10.15 LyS1.reconfigure LyS1config @22:41:10.18 PV.reconfigure PVconfig @22:41:10.23 ArS.reconfigure ArSconfig @22:41:10.26 LyS2.reconfigure LyS2config @22:41:10.44 TV.home.jog 0 @22:41:10.47 AirS.home.jog 0 @22:41:10.49 PV.home.jog 0 @22:41:10.71 LyS1.home.jog 0 @22:41:10.79 ArS.home.jog 0 @22:41:10.85 LyS2.home.jog 0 @22:41:11.29 TV.reconfigure HomeTV @22:41:11.32 AirS.reconfigure HomeMagSyringe @22:41:11.40 PV.reconfigure HomingPV @22:41:11.57 TV.jog -499 @22:41:11.59 PV.jog -114 @22:41:11.62 AirS.jog -127 @22:41:11.79 LyS1.reconfigure HomeSyringe @22:41:11.82 LyS2.reconfigure HomeSyringe @22:41:11.85 ArS.reconfigure HomeMagSyringe @22:41:11.97 LyS1.jog -112 @22:41:11.99 LyS2.jog -123 @22:41:12.07 ArS.jog -131 @22:41:12.18 PV.setRawPosition! -50 @22:41:12.20 AirS.setRawPosition! -50 @22:41:12.26 PV.seek :home @22:41:12.30 AirS.seek :home @22:41:12.44 LyS1.setRawPosition! -50 @22:41:12.50 LyS1.seek :home @22:41:12.60 LyS2.setRawPosition! -50 @22:41:12.63 PV.reconfigure PVconfig @22:41:12.65 ArS.setRawPosition! -50 @22:41:12.74 LyS2.seek :home @22:41:12.80 ArS.seek :home @22:41:12.93 LyS1.reconfigure LyS1config @22:41:12.95 AirS.reconfigure AirSconfig @22:41:13.11 LyS2.reconfigure LyS2config @22:41:13.18 ArS.reconfigure ArSconfig @22:41:13.33 TV.setRawPosition! 0 @22:41:13.37 TV.seek :home @22:41:13.46 TV.reconfigure TVconfig @22:41:13.57 TV.seek :clear @22:41:15.19 SC.reconfigure HomeSC @22:41:15.25 SC.home.jog 0 @22:41:15.47 Selecting Cartridge slot 36 @22:41:16.01 SC.reconfigure SCconfig @22:41:16.06 SC.seek 36 @22:41:16.44 LyS2.seek :cartridge @22:41:16.48 PV.seek :cartridge @22:41:36.75 -> Cmd.startFiltering @22:41:36.94 Duration of filtering limited to 1:05:00 @22:41:37.13 Priming sample loop w/100ml, bypass w/10ml @22:41:37.15 TV.seek :bypass @22:41:38.76 TV.seek :free @22:41:40.42 TV.coast @22:41:40.46 PB.open @22:41:40.48 Exhaust.close @22:41:41.22 Intake.open @22:41:42.03 Sea @23.1psia @22:41:42.04 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @22:41:47.57 Vacuum tare is 23% of full scale @22:41:47.64 Sea @23.0psia @22:41:47.66 SP.setPosition! 0ml @22:41:47.71 SP.reconfigure SPprime @22:41:47.78 SP.seek 10ml,1:21 @22:41:58.36 PB.close @22:41:58.38 Exhaust.open @22:41:59.27 Sea @23.5psia @22:41:59.28 SP.setPosition! 0ml @22:41:59.34 SP.seek 100ml,8:51 @22:44:02.77 Pressurizing cartridge to 26psi @22:44:02.78 Intake.close @22:44:02.82 Exhaust.close @22:44:03.64 PB.open @22:44:04.32 delay 2 seconds @22:44:06.39 TV.seek :crack @22:44:07.18 TV.seek :free @22:44:07.99 TV.coast @22:44:08.03 Intake.open @22:44:08.80 delay 2 seconds @22:44:11.10 PB.close @22:44:11.87 Sea @-0.6psia @22:44:11.88 SP.setPosition! 0ml @22:44:11.93 SP.reconfigure SPcharge @22:44:12.00 SP.seek 5ml,3:46 @22:44:17.86 Cartridge pressurized to 26.1psi @22:44:18.09 delay 3 seconds @22:44:21.16 Cartridge at 23.3psi 3 seconds later @22:44:21.29 TV.seek :cartridge @22:44:23.11 TV.seek :free @22:44:24.92 TV.coast @22:44:24.97 Sampling 1000.0ml @22:44:24.98 Exhaust.open @22:44:25.81 Sea @1.4psia @22:44:25.83 SP.setPosition! 0ml @22:44:25.89 SP.reconfigure SPsample @22:44:25.96 SP.seek 1000ml,1:23:53 @22:44:26.93 Cartridge 36 sampling 0/1000ml at 0.40ml/s with 19.7psi vacuum -7.6m deep (3.4psia) @22:45:26.93 Cartridge 36 sampling 25/1000ml at 0.37ml/s with 22.6psi vacuum -9.0m deep (1.4psia) @22:46:26.93 Cartridge 36 sampling 48/1000ml at 0.39ml/s with 24.8psi vacuum -7.5m deep (3.6psia) @22:47:26.93 Cartridge 36 sampling 72/1000ml at 0.39ml/s with 22.5psi vacuum -8.8m deep (1.6psia) @22:48:26.93 Cartridge 36 sampling 95/1000ml at 0.36ml/s with 22.1psi vacuum -7.8m deep (3.2psia) @22:49:26.93 Cartridge 36 sampling 118/1000ml at 0.39ml/s with 22.0psi vacuum -8.9m deep (1.5psia) @22:50:26.93 Cartridge 36 sampling 140/1000ml at 0.38ml/s with 21.7psi vacuum -8.3m deep (2.4psia) @22:51:26.93 Cartridge 36 sampling 162/1000ml at 0.35ml/s with 20.4psi vacuum -8.3m deep (2.4psia) @22:52:26.93 Cartridge 36 sampling 184/1000ml at 0.35ml/s with 20.2psi vacuum -8.8m deep (1.8psia) @22:53:26.93 Cartridge 36 sampling 205/1000ml at 0.34ml/s with 23.5psi vacuum -7.6m deep (3.5psia) @22:54:26.93 Cartridge 36 sampling 226/1000ml at 0.34ml/s with 25.2psi vacuum -9.3m deep (0.9psia) @22:55:26.93 Cartridge 36 sampling 246/1000ml at 0.33ml/s with 20.0psi vacuum -8.3m deep (2.4psia) @22:56:26.93 Cartridge 36 sampling 266/1000ml at 0.31ml/s with 22.6psi vacuum -9.0m deep (1.5psia) @22:57:26.93 Cartridge 36 sampling 285/1000ml at 0.33ml/s with 20.3psi vacuum -8.2m deep (2.6psia) @22:58:26.93 Cartridge 36 sampling 304/1000ml at 0.29ml/s with 21.7psi vacuum -9.5m deep (0.6psia) @22:59:26.93 Cartridge 36 sampling 323/1000ml at 0.31ml/s with 20.1psi vacuum -7.9m deep (3.0psia) @23:00:26.93 Cartridge 36 sampling 341/1000ml at 0.27ml/s with 22.2psi vacuum -9.1m deep (1.2psia) @23:01:26.93 Cartridge 36 sampling 359/1000ml at 0.31ml/s with 19.9psi vacuum -8.7m deep (1.8psia) @23:02:26.93 Cartridge 36 sampling 377/1000ml at 0.29ml/s with 18.8psi vacuum -8.6m deep (2.0psia) @23:03:26.93 Cartridge 36 sampling 394/1000ml at 0.26ml/s with 23.6psi vacuum -9.7m deep (0.4psia) @23:04:26.93 Cartridge 36 sampling 411/1000ml at 0.26ml/s with 23.0psi vacuum -8.2m deep (2.5psia) @23:05:26.93 Cartridge 36 sampling 427/1000ml at 0.25ml/s with 21.7psi vacuum -9.8m deep (0.3psia) @23:06:26.93 Cartridge 36 sampling 443/1000ml at 0.27ml/s with 24.6psi vacuum -8.2m deep (2.6psia) @23:07:26.93 Cartridge 36 sampling 459/1000ml at 0.25ml/s with 20.2psi vacuum -9.4m deep (0.8psia) @23:08:26.93 Cartridge 36 sampling 474/1000ml at 0.27ml/s with 22.6psi vacuum -8.4m deep (2.3psia) @23:09:26.93 Cartridge 36 sampling 489/1000ml at 0.26ml/s with 22.2psi vacuum -9.4m deep (0.8psia) @23:10:26.93 Cartridge 36 sampling 504/1000ml at 0.26ml/s with 22.2psi vacuum -8.4m deep (2.4psia) @23:11:26.93 Cartridge 36 sampling 518/1000ml at 0.25ml/s with 21.6psi vacuum -9.4m deep (0.8psia) @23:12:26.93 Cartridge 36 sampling 532/1000ml at 0.22ml/s with 22.0psi vacuum -8.8m deep (1.7psia) @23:13:26.93 Cartridge 36 sampling 546/1000ml at 0.21ml/s with 21.1psi vacuum -9.3m deep (0.9psia) @23:14:26.93 Cartridge 36 sampling 560/1000ml at 0.21ml/s with 22.2psi vacuum -8.8m deep (1.7psia) @23:15:26.93 Cartridge 36 sampling 573/1000ml at 0.22ml/s with 21.2psi vacuum -9.1m deep (1.2psia) @23:16:26.93 Cartridge 36 sampling 586/1000ml at 0.23ml/s with 23.4psi vacuum -8.9m deep (1.5psia) @23:17:26.93 Cartridge 36 sampling 598/1000ml at 0.21ml/s with 23.4psi vacuum -9.0m deep (1.4psia) @23:18:26.93 Cartridge 36 sampling 611/1000ml at 0.21ml/s with 22.3psi vacuum -9.9m deep (0.1psia) @23:19:26.93 Cartridge 36 sampling 624/1000ml at 0.20ml/s with 21.5psi vacuum -8.3m deep (2.4psia) @23:20:26.97 Cartridge 36 sampling 636/1000ml at 0.21ml/s with 23.4psi vacuum -10.1m deep (-0.2psia) @23:20:54.29 Flow averaged 0.29ml/s over 36:22 @23:20:54.32 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @23:20:54.94 Relieved excess vacuum in 7.9 seconds @23:20:54.96 SP.seek 1000ml,30:21 @23:20:55.43 Flow estimate reduced to 0.24ml/s @23:20:55.45 Waiting up to 11 seconds for vacuum to reduce from 26.1 to 18.0psi @23:20:56.07 Relieved excess vacuum in 1 second @23:20:56.09 SP.seek 1000ml,30:20 @23:21:26.93 Cartridge 36 sampling 649/1000ml at 0.21ml/s with 24.2psi vacuum -8.2m deep (2.6psia) @23:21:49.97 Flow averaged 0.22ml/s over 52 seconds @23:21:49.99 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @23:21:50.62 Relieved excess vacuum in 3.4 seconds @23:21:50.64 SP.seek 1000ml,29:23 @23:21:51.11 Flow estimate reduced to 0.18ml/s @23:21:51.12 Intake.close @23:21:51.16 Exhaust.close @23:21:51.97 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @23:21:52.05 Sampled 653.7ml @23:21:52.07 TV.seek :bypass @23:21:53.67 TV.seek :free @23:21:55.34 TV.coast @23:21:56.28 -> Cmd.startProcessing @23:21:56.48 PV.seek :reagent @23:21:57.39 Sample loop closed. Ready to Deliver Reagents @23:21:57.40 ArS.seek :sealed @23:22:01.05 ArS.seek :evac @23:22:15.02 delay 20 seconds @23:22:35.05 ArS.seek :clear @23:22:52.18 RNAlater soak for 10:00 @23:22:52.19 delay 10:00 @23:32:52.22 ArS.seek :tVent @23:32:53.87 delay 1 second @23:32:54.89 ArS.seek :evac @23:33:10.85 delay 10 seconds @23:33:20.88 ArS.seek :tVent @23:33:36.83 delay 1 second @23:33:37.85 ArS.seek :evac @23:33:53.81 delay 10 seconds @23:34:03.84 Sample preserved and evacuated @23:34:05.14 -> Cmd.stop @23:34:05.50 ArS.seek :clear @23:34:22.77 LyS2.seek :free @23:34:22.79 PV.seek :clear @23:34:24.62 Gate.power :motor,:OFF @23:34:24.64 Gate.power :main,:OFF @23:34:24.66 Gate.power :core,:OFF @23:34:24.68 Safely stopped and ready to power off ##-- file closed 2018-01-29T07:49:18.185Z --## ##-- file opened 2018-01-29T07:49:18.203Z --## @23:46:13.13 -> showStatus @23:46:15.13 -> Cmd.loadCartridge @23:46:15.17 Powering core bus @23:46:17.86 ArS.configure ArSconfig @23:46:17.96 LyS1.configure LyS1config @23:46:18.07 LyS2.configure LyS2config @23:46:18.18 AirS.configure AirSconfig @23:46:18.29 TV.configure TVconfig @23:46:18.41 SP.configure SPconfig @23:46:18.53 Sea.configure SPconfig @23:46:18.67 SC.configure SCconfig @23:46:18.79 PV.configure PVconfig @23:46:18.84 All elf controllers running firmware version 4.41 @23:46:18.86 Gate.power :main,:ON,limit to 5000mA @23:46:18.88 Gate.power :motor,:ON,limit to 5000mA @23:46:18.96 Intake.close @23:46:18.99 Exhaust.close @23:46:19.04 PB.close @23:46:19.50 PV.reconfigure PVconfig @23:46:19.56 TV.reconfigure TVconfig @23:46:19.59 LyS2.reconfigure LyS2config @23:46:19.63 ArS.reconfigure ArSconfig @23:46:19.66 AirS.reconfigure AirSconfig @23:46:19.73 LyS1.reconfigure LyS1config @23:46:19.90 PV.home.jog 0 @23:46:19.94 TV.home.jog 0 @23:46:19.98 ArS.home.jog 0 @23:46:20.01 AirS.home.jog 0 @23:46:20.25 LyS2.home.jog 0 @23:46:20.30 LyS1.home.jog 0 @23:46:20.70 TV.reconfigure HomeTV @23:46:20.77 PV.reconfigure HomingPV @23:46:20.83 ArS.reconfigure HomeMagSyringe @23:46:20.98 TV.jog -504 @23:46:21.02 PV.jog -117 @23:46:21.05 ArS.jog -130 @23:46:21.23 LyS2.reconfigure HomeSyringe @23:46:21.25 LyS1.reconfigure HomeSyringe @23:46:21.28 AirS.reconfigure HomeMagSyringe @23:46:21.39 LyS1.jog -113 @23:46:21.45 AirS.jog -127 @23:46:21.48 LyS2.jog -122 @23:46:21.65 PV.setRawPosition! -50 @23:46:21.67 ArS.setRawPosition! -50 @23:46:21.73 PV.seek :home @23:46:21.81 ArS.seek :home @23:46:21.99 AirS.setRawPosition! -50 @23:46:22.01 LyS2.setRawPosition! -50 @23:46:22.03 LyS1.setRawPosition! -50 @23:46:22.13 AirS.seek :home @23:46:22.18 LyS2.seek :home @23:46:22.21 LyS1.seek :home @23:46:22.37 PV.reconfigure PVconfig @23:46:22.39 ArS.reconfigure ArSconfig @23:46:22.51 LyS2.reconfigure LyS2config @23:46:22.60 AirS.reconfigure AirSconfig @23:46:22.63 LyS1.reconfigure LyS1config @23:46:22.79 TV.setRawPosition! 0 @23:46:22.83 TV.seek :home @23:46:22.92 TV.reconfigure TVconfig @23:46:23.03 TV.seek :clear @23:46:24.65 SC.reconfigure HomeSC @23:46:24.72 SC.home.jog 0 @23:46:24.96 Selecting Cartridge slot 35 @23:46:25.51 SC.reconfigure SCconfig @23:46:25.57 SC.seek 35 @23:46:25.95 LyS2.seek :cartridge @23:46:25.98 PV.seek :cartridge @23:46:47.88 -> Cmd.startFiltering @23:46:48.07 Duration of filtering limited to 1:05:00 @23:46:48.26 Priming sample loop w/100ml, bypass w/10ml @23:46:48.28 TV.seek :bypass @23:46:49.89 TV.seek :free @23:46:51.55 TV.coast @23:46:51.59 PB.open @23:46:51.61 Exhaust.close @23:46:52.30 Intake.open @23:46:53.09 Sea @25.4psia @23:46:53.11 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @23:46:58.63 Vacuum tare is 23% of full scale @23:46:58.70 Sea @25.3psia @23:46:58.72 SP.setPosition! 0ml @23:46:58.77 SP.reconfigure SPprime @23:46:58.84 SP.seek 10ml,1:21 @23:47:09.41 PB.close @23:47:09.43 Exhaust.open @23:47:10.27 Sea @25.4psia @23:47:10.28 SP.setPosition! 0ml @23:47:10.34 SP.seek 100ml,8:51 @23:49:13.56 Pressurizing cartridge to 26psi @23:49:13.57 Intake.close @23:49:13.60 Exhaust.close @23:49:14.37 PB.open @23:49:15.06 delay 2 seconds @23:49:17.13 TV.seek :crack @23:49:17.92 TV.seek :free @23:49:18.73 TV.coast @23:49:18.77 Intake.open @23:49:19.51 delay 2 seconds @23:49:21.53 PB.close @23:49:22.57 Sea @26.3psia @23:49:22.58 SP.setPosition! 0ml @23:49:22.63 SP.reconfigure SPcharge @23:49:22.70 SP.seek 5ml,3:46 @23:49:27.55 Cartridge pressurized to 26.6psi @23:49:27.78 delay 3 seconds @23:49:30.85 Cartridge at 23.4psi 3 seconds later @23:49:30.98 TV.seek :cartridge @23:49:32.79 TV.seek :free @23:49:34.60 TV.coast @23:49:34.65 Sampling 1000.0ml @23:49:34.66 Exhaust.open @23:49:35.47 Sea @-1.9psia @23:49:35.49 SP.setPosition! 0ml @23:49:35.54 SP.reconfigure SPsample @23:49:35.61 SP.seek 1000ml,1:23:53 @23:49:36.58 Cartridge 35 sampling 0/1000ml at 0.41ml/s with 23.7psi vacuum -6.8m deep (4.6psia) @23:50:36.59 Cartridge 35 sampling 24/1000ml at 0.41ml/s with 22.9psi vacuum -9.0m deep (1.4psia) @23:51:36.59 Cartridge 35 sampling 48/1000ml at 0.40ml/s with 22.7psi vacuum -7.0m deep (4.3psia) @23:52:36.59 Cartridge 35 sampling 72/1000ml at 0.39ml/s with 20.0psi vacuum -8.7m deep (1.8psia) @23:53:36.59 Cartridge 35 sampling 95/1000ml at 0.36ml/s with 23.0psi vacuum -7.4m deep (3.8psia) @23:54:36.59 Cartridge 35 sampling 118/1000ml at 0.39ml/s with 22.7psi vacuum -8.4m deep (2.3psia) @23:55:36.59 Cartridge 35 sampling 141/1000ml at 0.38ml/s with 21.3psi vacuum -8.7m deep (1.8psia) @23:56:36.59 Cartridge 35 sampling 163/1000ml at 0.38ml/s with 20.7psi vacuum -7.8m deep (3.1psia) @23:57:36.59 Cartridge 35 sampling 185/1000ml at 0.37ml/s with 21.2psi vacuum -8.0m deep (2.8psia) @23:58:36.59 Cartridge 35 sampling 207/1000ml at 0.37ml/s with 22.6psi vacuum -8.4m deep (2.2psia) @23:59:36.59 Cartridge 35 sampling 228/1000ml at 0.34ml/s with 22.9psi vacuum -7.8m deep (3.2psia) @00:00:36.59PST29-Jan-18 Cartridge 35 sampling 249/1000ml at 0.36ml/s with 20.4psi vacuum -8.2m deep (2.6psia) @00:01:36.59 Cartridge 35 sampling 270/1000ml at 0.33ml/s with 23.7psi vacuum -8.4m deep (2.3psia) @00:02:36.59 Cartridge 35 sampling 291/1000ml at 0.33ml/s with 24.9psi vacuum -7.8m deep (3.1psia) @00:03:36.59 Cartridge 35 sampling 311/1000ml at 0.35ml/s with 22.3psi vacuum -8.9m deep (1.5psia) @00:04:36.59 Cartridge 35 sampling 331/1000ml at 0.33ml/s with 21.1psi vacuum -7.5m deep (3.6psia) @00:05:36.59 Cartridge 35 sampling 350/1000ml at 0.34ml/s with 21.1psi vacuum -8.5m deep (2.1psia) @00:06:36.59 Cartridge 35 sampling 370/1000ml at 0.33ml/s with 21.9psi vacuum -8.3m deep (2.5psia) @00:07:36.59 Cartridge 35 sampling 389/1000ml at 0.33ml/s with 23.9psi vacuum -8.7m deep (1.8psia) @00:08:36.59 Cartridge 35 sampling 407/1000ml at 0.29ml/s with 23.3psi vacuum -8.0m deep (2.9psia) @00:09:36.59 Cartridge 35 sampling 426/1000ml at 0.29ml/s with 22.2psi vacuum -9.1m deep (1.2psia) @00:10:36.59 Cartridge 35 sampling 444/1000ml at 0.32ml/s with 21.7psi vacuum -7.7m deep (3.4psia) @00:11:36.59 Cartridge 35 sampling 462/1000ml at 0.27ml/s with 22.7psi vacuum -9.4m deep (0.8psia) @00:12:36.59 Cartridge 35 sampling 479/1000ml at 0.30ml/s with 23.6psi vacuum -8.0m deep (2.9psia) @00:13:36.59 Cartridge 35 sampling 496/1000ml at 0.28ml/s with 20.2psi vacuum -9.2m deep (1.1psia) @00:14:36.59 Cartridge 35 sampling 513/1000ml at 0.27ml/s with 19.8psi vacuum -7.7m deep (3.3psia) @00:15:36.59 Cartridge 35 sampling 530/1000ml at 0.26ml/s with 19.5psi vacuum -9.3m deep (1.0psia) @00:16:36.59 Cartridge 35 sampling 546/1000ml at 0.27ml/s with 22.1psi vacuum -8.5m deep (2.1psia) @00:17:36.59 Cartridge 35 sampling 562/1000ml at 0.25ml/s with 23.6psi vacuum -8.2m deep (2.5psia) @00:18:36.59 Cartridge 35 sampling 578/1000ml at 0.28ml/s with 21.7psi vacuum -8.8m deep (1.7psia) @00:19:36.59 Cartridge 35 sampling 593/1000ml at 0.25ml/s with 21.0psi vacuum -7.8m deep (3.2psia) @00:20:36.59 Cartridge 35 sampling 609/1000ml at 0.24ml/s with 19.6psi vacuum -9.3m deep (1.0psia) @00:21:36.59 Cartridge 35 sampling 623/1000ml at 0.26ml/s with 21.5psi vacuum -8.4m deep (2.3psia) @00:22:36.59 Cartridge 35 sampling 638/1000ml at 0.23ml/s with 22.0psi vacuum -8.9m deep (1.5psia) @00:23:36.59 Cartridge 35 sampling 652/1000ml at 0.22ml/s with 20.9psi vacuum -8.5m deep (2.1psia) @00:24:36.59 Cartridge 35 sampling 666/1000ml at 0.22ml/s with 21.1psi vacuum -9.3m deep (1.0psia) @00:25:36.59 Cartridge 35 sampling 680/1000ml at 0.21ml/s with 24.1psi vacuum -8.0m deep (2.9psia) @00:26:36.59 Cartridge 35 sampling 694/1000ml at 0.20ml/s with 22.2psi vacuum -9.1m deep (1.3psia) @00:27:36.59 Cartridge 35 sampling 707/1000ml at 0.24ml/s with 22.4psi vacuum -8.6m deep (2.0psia) @00:28:36.59 Cartridge 35 sampling 720/1000ml at 0.21ml/s with 22.1psi vacuum -8.0m deep (2.8psia) @00:29:36.59 Cartridge 35 sampling 733/1000ml at 0.23ml/s with 22.1psi vacuum -9.5m deep (0.7psia) @00:30:36.59 Cartridge 35 sampling 746/1000ml at 0.21ml/s with 21.3psi vacuum -8.0m deep (2.9psia) @00:31:36.87 Cartridge 35 sampling 759/1000ml at 0.21ml/s with 23.8psi vacuum -9.3m deep (1.0psia) @00:32:36.59 Cartridge 35 sampling 772/1000ml at 0.20ml/s with 24.0psi vacuum -7.9m deep (3.1psia) @00:33:36.59 Cartridge 35 sampling 784/1000ml at 0.20ml/s with 22.8psi vacuum -9.0m deep (1.4psia) @00:34:36.59 Cartridge 35 sampling 797/1000ml at 0.21ml/s with 23.6psi vacuum -8.4m deep (2.2psia) @00:35:36.59 Cartridge 35 sampling 809/1000ml at 0.21ml/s with 24.1psi vacuum -9.3m deep (0.9psia) @00:35:55.81 Flow averaged 0.29ml/s over 46:12 @00:35:55.84 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @00:35:56.46 Relieved excess vacuum in 9.8 seconds @00:35:56.48 SP.seek 1000ml,16:04 @00:36:36.59 Cartridge 35 sampling 822/1000ml at 0.21ml/s with 25.6psi vacuum -8.5m deep (2.2psia) @00:37:30.70 Flow averaged 0.22ml/s over 1:31 @00:37:30.73 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @00:37:31.35 Relieved excess vacuum in 4.6 seconds @00:37:31.37 SP.seek 1000ml,14:25 @00:37:35.94 Flow estimate reduced to 0.18ml/s @00:37:35.95 Intake.close @00:37:35.99 Exhaust.close @00:37:36.58 Cartridge 35 sampling 834/1000ml at 0.00ml/s with 0.9psi vacuum 7.3m deep (25.5psia) @00:37:36.80 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @00:37:36.89 Sampled 834.2ml @00:37:36.90 TV.seek :bypass @00:37:38.52 TV.seek :free @00:37:40.18 TV.coast @00:37:41.32 -> Cmd.startProcessing @00:37:41.51 PV.seek :reagent @00:37:42.44 Sample loop closed. Ready to Deliver Reagents @00:37:42.45 ArS.seek :sealed @00:37:46.09 ArS.seek :evac @00:38:00.05 delay 20 seconds @00:38:20.09 ArS.seek :clear @00:38:37.25 RNAlater soak for 10:00 @00:38:37.26 delay 10:00 @00:48:37.30 ArS.seek :tVent @00:48:38.95 delay 1 second @00:48:39.98 ArS.seek :evac @00:48:55.92 delay 10 seconds @00:49:05.96 ArS.seek :tVent @00:49:21.90 delay 1 second @00:49:22.92 ArS.seek :evac @00:49:38.87 delay 10 seconds @00:49:48.90 Sample preserved and evacuated @00:49:49.81 -> Cmd.stop @00:49:50.17 ArS.seek :clear @00:50:07.42 LyS2.seek :free @00:50:07.44 PV.seek :clear @00:50:09.26 Gate.power :motor,:OFF @00:50:09.28 Gate.power :main,:OFF @00:50:09.30 Gate.power :core,:OFF @00:50:09.33 Safely stopped and ready to power off ##-- file closed 2018-01-29T09:04:29.063Z --## ##-- file opened 2018-01-29T09:04:29.065Z --## @01:01:17.05 -> showStatus @01:01:19.04 -> Cmd.loadCartridge @01:01:19.10 Powering core bus @01:01:21.79 ArS.configure ArSconfig @01:01:21.88 LyS1.configure LyS1config @01:01:22.00 LyS2.configure LyS2config @01:01:22.11 AirS.configure AirSconfig @01:01:22.23 TV.configure TVconfig @01:01:22.34 SP.configure SPconfig @01:01:22.46 Sea.configure SPconfig @01:01:22.60 SC.configure SCconfig @01:01:22.71 PV.configure PVconfig @01:01:22.77 All elf controllers running firmware version 4.41 @01:01:22.78 Gate.power :main,:ON,limit to 5000mA @01:01:22.81 Gate.power :motor,:ON,limit to 5000mA @01:01:22.88 Intake.close @01:01:22.91 Exhaust.close @01:01:22.94 PB.close @01:01:23.47 TV.reconfigure TVconfig @01:01:23.49 AirS.reconfigure AirSconfig @01:01:23.53 LyS1.reconfigure LyS1config @01:01:23.57 PV.reconfigure PVconfig @01:01:23.59 ArS.reconfigure ArSconfig @01:01:23.69 LyS2.reconfigure LyS2config @01:01:23.80 TV.home.jog 0 @01:01:23.88 AirS.home.jog 0 @01:01:23.94 PV.home.jog 0 @01:01:24.22 LyS2.home.jog 0 @01:01:24.25 LyS1.home.jog 0 @01:01:24.28 ArS.home.jog 0 @01:01:24.71 TV.reconfigure HomeTV @01:01:24.72 AirS.reconfigure HomeMagSyringe @01:01:24.79 PV.reconfigure HomingPV @01:01:25.00 PV.jog -115 @01:01:25.02 TV.jog -497 @01:01:25.05 AirS.jog -127 @01:01:25.22 LyS1.reconfigure HomeSyringe @01:01:25.25 ArS.reconfigure HomeMagSyringe @01:01:25.31 LyS2.reconfigure HomeSyringe @01:01:25.38 LyS1.jog -113 @01:01:25.46 ArS.jog -128 @01:01:25.52 LyS2.jog -123 @01:01:25.63 PV.setRawPosition! -50 @01:01:25.65 AirS.setRawPosition! -50 @01:01:25.71 PV.seek :home @01:01:25.78 AirS.seek :home @01:01:25.96 LyS2.setRawPosition! -50 @01:01:25.98 LyS1.setRawPosition! -50 @01:01:26.01 ArS.setRawPosition! -50 @01:01:26.09 LyS2.seek :home @01:01:26.15 LyS1.seek :home @01:01:26.19 ArS.seek :home @01:01:26.37 PV.reconfigure PVconfig @01:01:26.38 AirS.reconfigure AirSconfig @01:01:26.51 LyS1.reconfigure LyS1config @01:01:26.61 ArS.reconfigure ArSconfig @01:01:26.62 LyS2.reconfigure LyS2config @01:01:26.79 TV.setRawPosition! 0 @01:01:26.84 TV.seek :home @01:01:26.92 TV.reconfigure TVconfig @01:01:27.04 TV.seek :clear @01:01:28.66 SC.reconfigure HomeSC @01:01:28.72 SC.home.jog 0 @01:01:28.95 Selecting Cartridge slot 34 @01:01:29.50 SC.reconfigure SCconfig @01:01:29.56 SC.seek 34 @01:01:29.94 LyS2.seek :cartridge @01:01:29.98 PV.seek :cartridge @01:01:51.79 -> Cmd.startFiltering @01:01:51.98 Duration of filtering limited to 1:05:00 @01:01:52.17 Priming sample loop w/100ml, bypass w/10ml @01:01:52.19 TV.seek :bypass @01:01:53.81 TV.seek :free @01:01:55.46 TV.coast @01:01:55.50 PB.open @01:01:55.53 Exhaust.close @01:01:56.22 Intake.open @01:01:57.05 Sea @26.4psia @01:01:57.07 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @01:02:02.60 Vacuum tare is 23% of full scale @01:02:02.67 Sea @26.2psia @01:02:02.69 SP.setPosition! 0ml @01:02:02.74 SP.reconfigure SPprime @01:02:02.80 SP.seek 10ml,1:21 @01:02:13.37 PB.close @01:02:13.39 Exhaust.open @01:02:14.23 Sea @25.7psia @01:02:14.25 SP.setPosition! 0ml @01:02:14.31 SP.seek 100ml,8:51 @01:04:17.48 Pressurizing cartridge to 26psi @01:04:17.49 Intake.close @01:04:17.51 Exhaust.close @01:04:18.32 PB.open @01:04:19.01 delay 2 seconds @01:04:21.09 TV.seek :crack @01:04:21.88 TV.seek :free @01:04:22.68 TV.coast @01:04:22.73 Intake.open @01:04:23.78 delay 2 seconds @01:04:25.81 PB.close @01:04:26.57 Sea @24.6psia @01:04:26.59 SP.setPosition! 0ml @01:04:26.64 SP.reconfigure SPcharge @01:04:26.70 SP.seek 5ml,3:46 @01:04:31.16 Cartridge pressurized to 26.7psi @01:04:31.39 delay 3 seconds @01:04:34.46 Cartridge at 23.3psi 3 seconds later @01:04:34.59 TV.seek :cartridge @01:04:36.40 TV.seek :free @01:04:38.20 TV.coast @01:04:38.25 Sampling 1000.0ml @01:04:38.26 Exhaust.open @01:04:39.06 Sea @-4.8psia @01:04:39.09 SP.setPosition! 0ml @01:04:39.14 SP.reconfigure SPsample @01:04:39.20 SP.seek 1000ml,1:23:53 @01:04:40.18 Cartridge 34 sampling 0/1000ml at 0.39ml/s with 23.1psi vacuum -8.7m deep (1.8psia) @01:05:40.19 Cartridge 34 sampling 25/1000ml at 0.41ml/s with 24.0psi vacuum -7.1m deep (4.2psia) @01:06:40.18 Cartridge 34 sampling 49/1000ml at 0.40ml/s with 23.0psi vacuum -8.7m deep (1.9psia) @01:07:40.19 Cartridge 34 sampling 73/1000ml at 0.41ml/s with 21.0psi vacuum -7.4m deep (3.7psia) @01:08:40.18 Cartridge 34 sampling 96/1000ml at 0.40ml/s with 23.8psi vacuum -8.2m deep (2.6psia) @01:09:40.19 Cartridge 34 sampling 119/1000ml at 0.39ml/s with 23.3psi vacuum -8.5m deep (2.1psia) @01:10:40.22 Cartridge 34 sampling 142/1000ml at 0.36ml/s with 18.4psi vacuum -7.2m deep (4.0psia) @01:11:40.19 Cartridge 34 sampling 165/1000ml at 0.38ml/s with 25.2psi vacuum -8.8m deep (1.7psia) @01:12:40.18 Cartridge 34 sampling 187/1000ml at 0.37ml/s with 21.5psi vacuum -7.2m deep (4.1psia) @01:13:40.18 Cartridge 34 sampling 209/1000ml at 0.36ml/s with 19.9psi vacuum -8.8m deep (1.6psia) @01:14:40.19 Cartridge 34 sampling 231/1000ml at 0.35ml/s with 19.8psi vacuum -8.2m deep (2.6psia) @01:15:40.19 Cartridge 34 sampling 252/1000ml at 0.36ml/s with 21.6psi vacuum -8.3m deep (2.4psia) @01:16:40.19 Cartridge 34 sampling 273/1000ml at 0.34ml/s with 24.2psi vacuum -7.8m deep (3.2psia) @01:17:40.18 Cartridge 34 sampling 294/1000ml at 0.35ml/s with 21.2psi vacuum -8.4m deep (2.3psia) @01:18:40.19 Cartridge 34 sampling 315/1000ml at 0.33ml/s with 19.6psi vacuum -7.8m deep (3.2psia) @01:19:40.19 Cartridge 34 sampling 335/1000ml at 0.32ml/s with 18.1psi vacuum -21.3m deep (-16.8psia) @01:20:40.19 Cartridge 34 sampling 355/1000ml at 0.34ml/s with 21.2psi vacuum -8.2m deep (2.6psia) @01:21:40.18 Cartridge 34 sampling 375/1000ml at 0.31ml/s with 23.3psi vacuum -8.0m deep (2.8psia) @01:22:40.19 Cartridge 34 sampling 394/1000ml at 0.32ml/s with 22.1psi vacuum -8.7m deep (1.8psia) @01:23:40.19 Cartridge 34 sampling 413/1000ml at 0.30ml/s with 22.5psi vacuum -7.6m deep (3.5psia) @01:24:40.18 Cartridge 34 sampling 432/1000ml at 0.32ml/s with 21.2psi vacuum -8.5m deep (2.1psia) @01:25:40.19 Cartridge 34 sampling 451/1000ml at 0.30ml/s with 17.9psi vacuum -7.8m deep (3.1psia) @01:26:40.19 Cartridge 34 sampling 469/1000ml at 0.30ml/s with 19.8psi vacuum -9.2m deep (1.1psia) @01:27:40.19 Cartridge 34 sampling 487/1000ml at 0.32ml/s with 21.1psi vacuum -8.5m deep (2.2psia) @01:28:40.19 Cartridge 34 sampling 505/1000ml at 0.28ml/s with 18.9psi vacuum -8.1m deep (2.7psia) @01:29:40.18 Cartridge 34 sampling 523/1000ml at 0.28ml/s with 20.0psi vacuum -8.9m deep (1.5psia) @01:30:40.19 Cartridge 34 sampling 540/1000ml at 0.30ml/s with 22.3psi vacuum -8.0m deep (2.9psia) @01:31:40.18 Cartridge 34 sampling 557/1000ml at 0.28ml/s with 20.0psi vacuum -9.1m deep (1.2psia) @01:32:40.19 Cartridge 34 sampling 574/1000ml at 0.28ml/s with 18.9psi vacuum -8.0m deep (2.8psia) @01:33:40.19 Cartridge 34 sampling 590/1000ml at 0.27ml/s with 25.7psi vacuum -8.9m deep (1.5psia) @01:34:40.18 Cartridge 34 sampling 606/1000ml at 0.27ml/s with 25.7psi vacuum -8.0m deep (2.9psia) @01:35:40.19 Cartridge 34 sampling 622/1000ml at 0.24ml/s with 21.8psi vacuum -9.0m deep (1.4psia) @01:36:40.19 Cartridge 34 sampling 638/1000ml at 0.27ml/s with 24.2psi vacuum -8.7m deep (1.9psia) @01:37:40.19 Cartridge 34 sampling 654/1000ml at 0.23ml/s with 22.4psi vacuum -8.0m deep (2.9psia) @01:38:40.18 Cartridge 34 sampling 669/1000ml at 0.27ml/s with 22.4psi vacuum -9.0m deep (1.5psia) @01:39:40.19 Cartridge 34 sampling 684/1000ml at 0.26ml/s with 23.2psi vacuum -7.9m deep (3.0psia) @01:40:40.19 Cartridge 34 sampling 699/1000ml at 0.26ml/s with 19.8psi vacuum -9.3m deep (1.0psia) @01:41:40.19 Cartridge 34 sampling 713/1000ml at 0.26ml/s with 21.4psi vacuum -8.1m deep (2.7psia) @01:42:40.18 Cartridge 34 sampling 728/1000ml at 0.25ml/s with 22.1psi vacuum -8.7m deep (1.9psia) @01:43:40.19 Cartridge 34 sampling 742/1000ml at 0.22ml/s with 24.5psi vacuum -8.6m deep (1.9psia) @01:44:40.19 Cartridge 34 sampling 756/1000ml at 0.22ml/s with 24.5psi vacuum -8.2m deep (2.6psia) @01:45:40.18 Cartridge 34 sampling 769/1000ml at 0.25ml/s with 22.9psi vacuum -8.8m deep (1.6psia) @01:46:40.25 Cartridge 34 sampling 783/1000ml at 0.21ml/s with 23.1psi vacuum -8.2m deep (2.5psia) @01:47:40.19 Cartridge 34 sampling 796/1000ml at 0.24ml/s with 20.8psi vacuum -9.1m deep (1.3psia) @01:48:40.19 Cartridge 34 sampling 809/1000ml at 0.24ml/s with 23.1psi vacuum -7.9m deep (3.1psia) @01:49:40.19 Cartridge 34 sampling 822/1000ml at 0.21ml/s with 23.3psi vacuum -9.3m deep (0.9psia) @01:50:40.19 Cartridge 34 sampling 835/1000ml at 0.21ml/s with 24.0psi vacuum -7.8m deep (3.1psia) @01:51:40.19 Cartridge 34 sampling 848/1000ml at 0.22ml/s with 22.2psi vacuum -9.1m deep (1.2psia) @01:52:40.19 Cartridge 34 sampling 860/1000ml at 0.20ml/s with 24.2psi vacuum -8.1m deep (2.7psia) @01:53:40.19 Cartridge 34 sampling 873/1000ml at 0.21ml/s with 23.8psi vacuum -8.8m deep (1.8psia) @01:54:40.19 Cartridge 34 sampling 886/1000ml at 0.21ml/s with 25.6psi vacuum -8.8m deep (1.6psia) @01:55:40.19 Cartridge 34 sampling 898/1000ml at 0.21ml/s with 25.4psi vacuum -8.8m deep (1.6psia) @01:56:40.19 Cartridge 34 sampling 911/1000ml at 0.21ml/s with 26.4psi vacuum -8.6m deep (2.0psia) @01:56:44.83 Flow averaged 0.29ml/s over 52:02 @01:56:44.85 Waiting up to 11 seconds for vacuum to reduce from 26.2 to 18.0psi @01:56:45.48 Relieved excess vacuum in 5.3 seconds @01:56:45.51 SP.seek 1000ml,7:52 @01:57:40.18 Cartridge 34 sampling 923/1000ml at 0.21ml/s with 26.5psi vacuum -8.8m deep (1.7psia) @01:57:56.89 Flow averaged 0.23ml/s over 1:05 @01:57:56.91 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @01:57:57.53 Relieved excess vacuum in 7.3 seconds @01:57:57.56 SP.seek 1000ml,6:37 @01:58:40.18 Cartridge 34 sampling 936/1000ml at 0.20ml/s with 21.8psi vacuum -8.7m deep (1.9psia) @01:58:43.02 Flow averaged 0.22ml/s over 43 seconds @01:58:43.04 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @01:58:43.66 Relieved excess vacuum in 3.5 seconds @01:58:43.69 SP.seek 1000ml,5:49 @01:59:20.17 Flow averaged 0.23ml/s over 34 seconds @01:59:20.19 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @01:59:20.81 Relieved excess vacuum in 4 seconds @01:59:20.84 SP.seek 1000ml,5:10 @01:59:40.18 Cartridge 34 sampling 948/1000ml at 0.21ml/s with 23.5psi vacuum -8.8m deep (1.7psia) @01:59:40.48 Flow averaged 0.21ml/s over 20 seconds @01:59:40.50 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @01:59:41.12 Relieved excess vacuum in .9 seconds @01:59:41.15 SP.seek 1000ml,4:50 @02:00:08.48 Flow averaged 0.25ml/s over 24 seconds @02:00:08.50 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @02:00:09.12 Relieved excess vacuum in 4.9 seconds @02:00:09.15 SP.seek 1000ml,4:21 @02:00:10.63 Flow estimate reduced to 0.20ml/s @02:00:10.65 Intake.close @02:00:10.68 Exhaust.close @02:00:11.46 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @02:00:11.55 Sampled 954.3ml @02:00:11.57 TV.seek :bypass @02:00:13.19 TV.seek :free @02:00:14.85 TV.coast @02:00:16.08 -> Cmd.startProcessing @02:00:16.28 PV.seek :reagent @02:00:17.19 Sample loop closed. Ready to Deliver Reagents @02:00:17.21 ArS.seek :sealed @02:00:20.85 ArS.seek :evac @02:00:34.79 delay 20 seconds @02:00:54.83 ArS.seek :clear @02:01:11.94 RNAlater soak for 10:00 @02:01:11.95 delay 10:00 @02:11:11.99 ArS.seek :tVent @02:11:13.63 delay 1 second @02:11:14.66 ArS.seek :evac @02:11:30.60 delay 10 seconds @02:11:40.64 ArS.seek :tVent @02:11:56.57 delay 1 second @02:11:57.60 ArS.seek :evac @02:12:13.53 delay 10 seconds @02:12:23.57 Sample preserved and evacuated @02:12:24.58 -> Cmd.stop @02:12:24.95 ArS.seek :clear @02:12:42.18 LyS2.seek :free @02:12:42.20 PV.seek :clear @02:12:44.02 Gate.power :motor,:OFF @02:12:44.05 Gate.power :main,:OFF @02:12:44.07 Gate.power :core,:OFF @02:12:44.09 Safely stopped and ready to power off ##-- file closed 2018-01-29T10:35:47.453Z --## ##-- file opened 2018-01-29T10:35:47.454Z --## @02:32:27.00 -> showStatus @02:32:29.00 -> Cmd.loadCartridge @02:32:29.05 Powering core bus @02:32:31.74 ArS.configure ArSconfig @02:32:31.83 LyS1.configure LyS1config @02:32:31.95 LyS2.configure LyS2config @02:32:32.05 AirS.configure AirSconfig @02:32:32.17 TV.configure TVconfig @02:32:32.29 SP.configure SPconfig @02:32:32.40 Sea.configure SPconfig @02:32:32.54 SC.configure SCconfig @02:32:32.65 PV.configure PVconfig @02:32:32.71 All elf controllers running firmware version 4.41 @02:32:32.73 Gate.power :main,:ON,limit to 5000mA @02:32:32.75 Gate.power :motor,:ON,limit to 5000mA @02:32:32.84 Intake.close @02:32:32.87 Exhaust.close @02:32:32.91 PB.close @02:32:33.37 PV.reconfigure PVconfig @02:32:33.42 TV.reconfigure TVconfig @02:32:33.45 LyS2.reconfigure LyS2config @02:32:33.49 ArS.reconfigure ArSconfig @02:32:33.53 AirS.reconfigure AirSconfig @02:32:33.57 LyS1.reconfigure LyS1config @02:32:33.77 TV.home.jog 0 @02:32:33.80 PV.home.jog 0 @02:32:33.82 LyS2.home.jog 0 @02:32:33.85 LyS1.home.jog 0 @02:32:34.10 ArS.home.jog 0 @02:32:34.17 AirS.home.jog 0 @02:32:34.62 TV.reconfigure HomeTV @02:32:34.69 PV.reconfigure HomingPV @02:32:34.73 LyS2.reconfigure HomeSyringe @02:32:34.92 LyS2.jog -122 @02:32:34.94 TV.jog -499 @02:32:34.98 PV.jog -118 @02:32:35.15 LyS1.reconfigure HomeSyringe @02:32:35.18 AirS.reconfigure HomeMagSyringe @02:32:35.22 ArS.reconfigure HomeMagSyringe @02:32:35.34 LyS1.jog -113 @02:32:35.39 AirS.jog -127 @02:32:35.42 ArS.jog -130 @02:32:35.58 LyS2.setRawPosition! -50 @02:32:35.59 PV.setRawPosition! -50 @02:32:35.69 LyS2.seek :home @02:32:35.72 PV.seek :home @02:32:35.93 LyS1.setRawPosition! -50 @02:32:35.95 AirS.setRawPosition! -50 @02:32:35.98 ArS.setRawPosition! -50 @02:32:36.08 LyS1.seek :home @02:32:36.12 AirS.seek :home @02:32:36.15 ArS.seek :home @02:32:36.35 LyS2.reconfigure LyS2config @02:32:36.36 PV.reconfigure PVconfig @02:32:36.52 LyS1.reconfigure LyS1config @02:32:36.60 AirS.reconfigure AirSconfig @02:32:36.62 ArS.reconfigure ArSconfig @02:32:36.73 TV.setRawPosition! 0 @02:32:36.78 TV.seek :home @02:32:36.86 TV.reconfigure TVconfig @02:32:36.98 TV.seek :clear @02:32:38.60 SC.reconfigure HomeSC @02:32:38.66 SC.home.jog 0 @02:32:38.87 Selecting Cartridge slot 33 @02:32:39.43 SC.reconfigure SCconfig @02:32:39.48 SC.seek 33 @02:32:39.86 LyS2.seek :cartridge @02:32:39.89 PV.seek :cartridge @02:33:01.75 -> Cmd.startFiltering @02:33:01.94 Duration of filtering limited to 1:05:00 @02:33:02.14 Priming sample loop w/100ml, bypass w/10ml @02:33:02.16 TV.seek :bypass @02:33:03.78 TV.seek :free @02:33:05.43 TV.coast @02:33:05.48 PB.open @02:33:05.50 Exhaust.close @02:33:06.19 Intake.open @02:33:06.97 Sea @20.1psia @02:33:06.98 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @02:33:12.51 Vacuum tare is 23% of full scale @02:33:12.58 Sea @19.9psia @02:33:12.60 SP.setPosition! 0ml @02:33:12.65 SP.reconfigure SPprime @02:33:12.71 SP.seek 10ml,1:21 @02:33:23.29 PB.close @02:33:23.31 Exhaust.open @02:33:24.19 Sea @19.7psia @02:33:24.21 SP.setPosition! 0ml @02:33:24.27 SP.seek 100ml,8:51 @02:35:27.62 Pressurizing cartridge to 26psi @02:35:27.63 Intake.close @02:35:27.66 Exhaust.close @02:35:28.47 PB.open @02:35:29.13 delay 2 seconds @02:35:31.21 TV.seek :crack @02:35:32.00 TV.seek :free @02:35:32.81 TV.coast @02:35:32.85 Intake.open @02:35:33.89 delay 2 seconds @02:35:35.92 PB.close @02:35:36.62 Sea @19.2psia @02:35:36.64 SP.setPosition! 0ml @02:35:36.69 SP.reconfigure SPcharge @02:35:36.75 SP.seek 5ml,3:46 @02:35:41.95 Cartridge pressurized to 26.2psi @02:35:42.18 Pressure peaked at 26.3psi @02:35:42.19 delay 3 seconds @02:35:45.26 Cartridge at 23.8psi 3 seconds later @02:35:45.39 TV.seek :cartridge @02:35:47.21 TV.seek :free @02:35:49.01 TV.coast @02:35:49.06 Sampling 1000.0ml @02:35:49.07 Exhaust.open @02:35:49.88 Sea @-6.3psia @02:35:49.90 SP.setPosition! 0ml @02:35:49.96 SP.reconfigure SPsample @02:35:50.02 SP.seek 1000ml,1:23:53 @02:35:50.99 Cartridge 33 sampling 0/1000ml at 0.42ml/s with 19.5psi vacuum -11.8m deep (-2.7psia) @02:36:51.00 Cartridge 33 sampling 25/1000ml at 0.40ml/s with 22.9psi vacuum -10.7m deep (-1.1psia) @02:37:51.00 Cartridge 33 sampling 50/1000ml at 0.41ml/s with 22.5psi vacuum -11.4m deep (-2.1psia) @02:38:51.00 Cartridge 33 sampling 74/1000ml at 0.38ml/s with 18.3psi vacuum -12.0m deep (-3.1psia) @02:39:51.00 Cartridge 33 sampling 98/1000ml at 0.39ml/s with 20.7psi vacuum -11.0m deep (-1.6psia) @02:40:51.00 Cartridge 33 sampling 121/1000ml at 0.37ml/s with 22.5psi vacuum -11.6m deep (-2.4psia) @02:41:51.00 Cartridge 33 sampling 144/1000ml at 0.38ml/s with 20.2psi vacuum -10.5m deep (-0.9psia) @02:42:51.00 Cartridge 33 sampling 167/1000ml at 0.35ml/s with 19.0psi vacuum -12.3m deep (-3.5psia) @02:43:51.00 Cartridge 33 sampling 189/1000ml at 0.38ml/s with 22.8psi vacuum -10.7m deep (-1.1psia) @02:44:51.00 Cartridge 33 sampling 211/1000ml at 0.38ml/s with 21.4psi vacuum -12.2m deep (-3.3psia) @02:45:51.00 Cartridge 33 sampling 233/1000ml at 0.35ml/s with 19.9psi vacuum -11.3m deep (-2.1psia) @02:46:51.00 Cartridge 33 sampling 254/1000ml at 0.36ml/s with 20.9psi vacuum -12.3m deep (-3.5psia) @02:47:51.00 Cartridge 33 sampling 274/1000ml at 0.35ml/s with 20.8psi vacuum -11.0m deep (-1.5psia) @02:48:51.00 Cartridge 33 sampling 295/1000ml at 0.33ml/s with 19.8psi vacuum -12.5m deep (-3.8psia) @02:49:51.00 Cartridge 33 sampling 315/1000ml at 0.34ml/s with 24.8psi vacuum -11.1m deep (-1.7psia) @02:50:51.00 Cartridge 33 sampling 334/1000ml at 0.30ml/s with 22.4psi vacuum -12.4m deep (-3.6psia) @02:51:50.99 Cartridge 33 sampling 354/1000ml at 0.32ml/s with 19.7psi vacuum -11.7m deep (-2.6psia) @02:52:51.00 Cartridge 33 sampling 373/1000ml at 0.32ml/s with 18.5psi vacuum -11.9m deep (-2.9psia) @02:53:51.00 Cartridge 33 sampling 391/1000ml at 0.30ml/s with 23.5psi vacuum -12.1m deep (-3.2psia) @02:54:51.00 Cartridge 33 sampling 410/1000ml at 0.31ml/s with 22.9psi vacuum -11.1m deep (-1.7psia) @02:55:51.00 Cartridge 33 sampling 428/1000ml at 0.28ml/s with 21.7psi vacuum -12.7m deep (-4.1psia) @02:56:51.00 Cartridge 33 sampling 445/1000ml at 0.28ml/s with 17.4psi vacuum -11.3m deep (-2.0psia) @02:57:51.00 Cartridge 33 sampling 463/1000ml at 0.30ml/s with 21.3psi vacuum -12.6m deep (-4.0psia) @02:58:51.00 Cartridge 33 sampling 479/1000ml at 0.27ml/s with 25.0psi vacuum -11.0m deep (-1.6psia) @02:59:51.00 Cartridge 33 sampling 496/1000ml at 0.27ml/s with 21.6psi vacuum -12.4m deep (-3.6psia) @03:00:51.00 Cartridge 33 sampling 512/1000ml at 0.27ml/s with 19.3psi vacuum -11.4m deep (-2.2psia) @03:01:51.00 Cartridge 33 sampling 528/1000ml at 0.28ml/s with 21.3psi vacuum -12.5m deep (-3.7psia) @03:02:51.00 Cartridge 33 sampling 544/1000ml at 0.23ml/s with 20.5psi vacuum -11.5m deep (-2.3psia) @03:03:51.00 Cartridge 33 sampling 560/1000ml at 0.28ml/s with 22.7psi vacuum -12.2m deep (-3.4psia) @03:04:51.00 Cartridge 33 sampling 575/1000ml at 0.24ml/s with 22.2psi vacuum -12.4m deep (-3.6psia) @03:05:51.00 Cartridge 33 sampling 589/1000ml at 0.22ml/s with 24.1psi vacuum -11.7m deep (-2.6psia) @03:06:51.00 Cartridge 33 sampling 604/1000ml at 0.25ml/s with 24.5psi vacuum -12.7m deep (-4.1psia) @03:07:51.00 Cartridge 33 sampling 618/1000ml at 0.22ml/s with 22.6psi vacuum -11.9m deep (-2.9psia) @03:08:51.00 Cartridge 33 sampling 632/1000ml at 0.23ml/s with 19.5psi vacuum -12.9m deep (-4.4psia) @03:09:51.00 Cartridge 33 sampling 646/1000ml at 0.23ml/s with 22.8psi vacuum -12.0m deep (-3.0psia) @03:10:51.00 Cartridge 33 sampling 659/1000ml at 0.23ml/s with 21.4psi vacuum -12.9m deep (-4.3psia) @03:11:51.00 Cartridge 33 sampling 672/1000ml at 0.21ml/s with 21.6psi vacuum -11.9m deep (-2.9psia) @03:12:51.00 Cartridge 33 sampling 686/1000ml at 0.21ml/s with 23.9psi vacuum -12.5m deep (-3.8psia) @03:13:51.00 Cartridge 33 sampling 698/1000ml at 0.22ml/s with 22.9psi vacuum -12.3m deep (-3.4psia) @03:14:51.00 Cartridge 33 sampling 711/1000ml at 0.21ml/s with 23.5psi vacuum -25.9m deep (-23.5psia) @03:15:51.00 Cartridge 33 sampling 724/1000ml at 0.21ml/s with 22.1psi vacuum -13.1m deep (-4.6psia) @03:16:51.28 Cartridge 33 sampling 736/1000ml at 0.21ml/s with 25.4psi vacuum -11.8m deep (-2.7psia) @03:17:51.00 Cartridge 33 sampling 749/1000ml at 0.21ml/s with 23.3psi vacuum -12.8m deep (-4.3psia) @03:18:41.84 Flow averaged 0.30ml/s over 42:52 @03:18:41.87 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @03:18:42.48 Relieved excess vacuum in 1.4 seconds @03:18:42.51 SP.seek 1000ml,20:33 @03:18:51.00 Cartridge 33 sampling 761/1000ml at 0.21ml/s with 22.6psi vacuum -11.6m deep (-2.5psia) @03:19:20.40 Flow averaged 0.28ml/s over 29 seconds @03:19:20.42 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @03:19:21.04 Relieved excess vacuum in 10 seconds @03:19:21.07 SP.seek 1000ml,19:53 @03:19:51.00 Cartridge 33 sampling 774/1000ml at 0.21ml/s with 24.4psi vacuum -12.8m deep (-4.1psia) @03:19:59.11 Flow averaged 0.27ml/s over 30 seconds @03:19:59.14 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @03:19:59.76 Relieved excess vacuum in 8.7 seconds @03:19:59.79 SP.seek 1000ml,19:13 @03:20:24.18 Flow averaged 0.22ml/s over 24 seconds @03:20:24.20 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @03:20:24.82 Relieved excess vacuum in 2 seconds @03:20:24.85 SP.seek 1000ml,18:48 @03:20:51.00 Cartridge 33 sampling 786/1000ml at 0.21ml/s with 24.8psi vacuum -11.8m deep (-2.7psia) @03:21:04.64 Flow averaged 0.23ml/s over 37 seconds @03:21:04.66 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @03:21:05.28 Relieved excess vacuum in 4.2 seconds @03:21:05.31 SP.seek 1000ml,18:06 @03:21:12.97 Flow estimate reduced to 0.18ml/s @03:21:12.98 Intake.close @03:21:13.01 Exhaust.close @03:21:13.83 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @03:21:13.91 Sampled 790.5ml @03:21:13.93 TV.seek :bypass @03:21:15.55 TV.seek :free @03:21:17.21 TV.coast @03:21:18.16 -> Cmd.startProcessing @03:21:18.38 PV.seek :reagent @03:21:19.29 Sample loop closed. Ready to Deliver Reagents @03:21:19.31 ArS.seek :sealed @03:21:22.96 ArS.seek :evac @03:21:36.91 delay 20 seconds @03:21:56.95 ArS.seek :clear @03:22:14.08 RNAlater soak for 10:00 @03:22:14.09 delay 10:00 @03:32:14.13 ArS.seek :tVent @03:32:15.77 delay 1 second @03:32:16.80 ArS.seek :evac @03:32:32.73 delay 10 seconds @03:32:42.77 ArS.seek :tVent @03:32:58.71 delay 1 second @03:32:59.74 ArS.seek :evac @03:33:15.68 delay 10 seconds @03:33:25.72 Sample preserved and evacuated @03:33:26.65 -> Cmd.stop @03:33:27.02 ArS.seek :clear @03:33:44.26 PV.seek :clear @03:33:44.29 LyS2.seek :free @03:33:46.13 Gate.power :motor,:OFF @03:33:46.16 Gate.power :main,:OFF @03:33:46.18 Gate.power :core,:OFF @03:33:46.20 Safely stopped and ready to power off ##-- file closed 2018-01-29T11:48:03.541Z --## ##-- file opened 2018-01-29T11:48:03.543Z --## @03:44:36.41 -> showStatus @03:44:38.41 -> Cmd.loadCartridge @03:44:38.45 Powering core bus @03:44:41.14 ArS.configure ArSconfig @03:44:41.24 LyS1.configure LyS1config @03:44:41.36 LyS2.configure LyS2config @03:44:41.46 AirS.configure AirSconfig @03:44:41.58 TV.configure TVconfig @03:44:41.70 SP.configure SPconfig @03:44:41.82 Sea.configure SPconfig @03:44:41.96 SC.configure SCconfig @03:44:42.08 PV.configure PVconfig @03:44:42.13 All elf controllers running firmware version 4.41 @03:44:42.15 Gate.power :main,:ON,limit to 5000mA @03:44:42.17 Gate.power :motor,:ON,limit to 5000mA @03:44:42.25 Intake.close @03:44:42.28 Exhaust.close @03:44:42.31 PB.close @03:44:42.84 TV.reconfigure TVconfig @03:44:42.92 AirS.reconfigure AirSconfig @03:44:42.95 LyS1.reconfigure LyS1config @03:44:42.98 ArS.reconfigure ArSconfig @03:44:43.02 LyS2.reconfigure LyS2config @03:44:43.06 PV.reconfigure PVconfig @03:44:43.23 TV.home.jog 0 @03:44:43.28 LyS1.home.jog 0 @03:44:43.50 AirS.home.jog 0 @03:44:43.56 ArS.home.jog 0 @03:44:43.58 PV.home.jog 0 @03:44:43.61 LyS2.home.jog 0 @03:44:44.10 TV.reconfigure HomeTV @03:44:44.13 AirS.reconfigure HomeMagSyringe @03:44:44.21 LyS1.reconfigure HomeSyringe @03:44:44.26 PV.reconfigure HomingPV @03:44:44.39 AirS.jog -127 @03:44:44.45 TV.jog -503 @03:44:44.49 LyS1.jog -114 @03:44:44.53 PV.jog -114 @03:44:44.70 LyS2.reconfigure HomeSyringe @03:44:44.72 ArS.reconfigure HomeMagSyringe @03:44:44.85 LyS2.jog -123 @03:44:44.92 ArS.jog -129 @03:44:45.04 PV.setRawPosition! -50 @03:44:45.06 AirS.setRawPosition! -50 @03:44:45.08 LyS1.setRawPosition! -50 @03:44:45.17 AirS.seek :home @03:44:45.23 PV.seek :home @03:44:45.25 LyS1.seek :home @03:44:45.42 ArS.setRawPosition! -50 @03:44:45.44 LyS2.setRawPosition! -50 @03:44:45.50 ArS.seek :home @03:44:45.55 LyS2.seek :home @03:44:45.73 PV.reconfigure PVconfig @03:44:45.74 AirS.reconfigure AirSconfig @03:44:45.77 LyS1.reconfigure LyS1config @03:44:45.94 LyS2.reconfigure LyS2config @03:44:45.96 ArS.reconfigure ArSconfig @03:44:46.27 TV.setRawPosition! 0 @03:44:46.32 TV.seek :home @03:44:46.40 TV.reconfigure TVconfig @03:44:46.52 TV.seek :clear @03:44:48.14 SC.reconfigure HomeSC @03:44:48.20 SC.home.jog 0 @03:44:48.43 Selecting Cartridge slot 32 @03:44:48.98 SC.reconfigure SCconfig @03:44:49.03 SC.seek 32 @03:44:49.42 LyS2.seek :cartridge @03:44:49.45 PV.seek :cartridge @03:45:10.76 -> Cmd.startFiltering @03:45:10.95 Duration of filtering limited to 1:05:00 @03:45:11.14 Priming sample loop w/100ml, bypass w/10ml @03:45:11.16 TV.seek :bypass @03:45:12.77 TV.seek :free @03:45:14.43 TV.coast @03:45:14.47 Exhaust.close @03:45:14.50 PB.open @03:45:15.22 Intake.open @03:45:16.05 Sea @20.7psia @03:45:16.07 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @03:45:21.59 Vacuum tare is 23% of full scale @03:45:21.67 Sea @20.9psia @03:45:21.68 SP.setPosition! 0ml @03:45:21.73 SP.reconfigure SPprime @03:45:21.80 SP.seek 10ml,1:21 @03:45:32.37 PB.close @03:45:32.39 Exhaust.open @03:45:33.27 Sea @21.2psia @03:45:33.28 SP.setPosition! 0ml @03:45:33.34 SP.seek 100ml,8:51 @03:47:36.79 Pressurizing cartridge to 26psi @03:47:36.80 Intake.close @03:47:36.84 Exhaust.close @03:47:37.63 PB.open @03:47:38.31 delay 2 seconds @03:47:40.38 TV.seek :crack @03:47:41.17 TV.seek :free @03:47:41.98 TV.coast @03:47:42.02 Intake.open @03:47:43.04 delay 2 seconds @03:47:45.06 PB.close @03:47:45.81 Sea @21.1psia @03:47:45.82 SP.setPosition! 0ml @03:47:45.87 SP.reconfigure SPcharge @03:47:45.94 SP.seek 5ml,3:46 @03:47:51.21 Cartridge pressurized to 26.4psi @03:47:51.44 delay 3 seconds @03:47:54.51 Cartridge at 23.7psi 3 seconds later @03:47:54.64 TV.seek :cartridge @03:47:56.45 TV.seek :free @03:47:58.26 TV.coast @03:47:58.31 Sampling 1000.0ml @03:47:58.32 Exhaust.open @03:47:59.14 Sea @-7.9psia @03:47:59.16 SP.setPosition! 0ml @03:47:59.21 SP.reconfigure SPsample @03:47:59.28 SP.seek 1000ml,1:23:53 @03:48:00.25 Cartridge 32 sampling 0/1000ml at 0.38ml/s with 19.5psi vacuum -10.7m deep (-1.1psia) @03:49:00.26 Cartridge 32 sampling 24/1000ml at 0.39ml/s with 23.6psi vacuum -11.9m deep (-2.9psia) @03:50:00.26 Cartridge 32 sampling 48/1000ml at 0.40ml/s with 22.6psi vacuum -10.8m deep (-1.2psia) @03:51:00.26 Cartridge 32 sampling 71/1000ml at 0.39ml/s with 20.6psi vacuum -11.5m deep (-2.2psia) @03:52:00.26 Cartridge 32 sampling 94/1000ml at 0.39ml/s with 21.8psi vacuum -11.4m deep (-2.1psia) @03:53:00.26 Cartridge 32 sampling 116/1000ml at 0.37ml/s with 23.2psi vacuum -11.3m deep (-1.9psia) @03:54:00.26 Cartridge 32 sampling 139/1000ml at 0.36ml/s with 23.0psi vacuum -11.8m deep (-2.7psia) @03:55:00.27 Cartridge 32 sampling 161/1000ml at 0.33ml/s with 21.3psi vacuum -10.9m deep (-1.3psia) @03:56:00.26 Cartridge 32 sampling 182/1000ml at 0.36ml/s with 22.3psi vacuum -11.8m deep (-2.7psia) @03:57:00.26 Cartridge 32 sampling 203/1000ml at 0.36ml/s with 21.9psi vacuum -11.7m deep (-2.5psia) @03:58:00.26 Cartridge 32 sampling 224/1000ml at 0.33ml/s with 24.1psi vacuum -10.9m deep (-1.4psia) @03:59:00.26 Cartridge 32 sampling 244/1000ml at 0.32ml/s with 21.5psi vacuum -12.3m deep (-3.4psia) @04:00:00.26 Cartridge 32 sampling 265/1000ml at 0.33ml/s with 17.5psi vacuum -11.3m deep (-2.1psia) @04:01:00.26 Cartridge 32 sampling 284/1000ml at 0.31ml/s with 18.0psi vacuum -12.1m deep (-3.2psia) @04:02:00.26 Cartridge 32 sampling 304/1000ml at 0.29ml/s with 20.9psi vacuum -11.3m deep (-2.0psia) @04:03:00.26 Cartridge 32 sampling 323/1000ml at 0.29ml/s with 22.7psi vacuum -12.4m deep (-3.6psia) @04:04:00.26 Cartridge 32 sampling 342/1000ml at 0.32ml/s with 24.7psi vacuum -11.3m deep (-2.0psia) @04:05:00.26 Cartridge 32 sampling 360/1000ml at 0.30ml/s with 19.6psi vacuum -12.5m deep (-3.8psia) @04:06:00.26 Cartridge 32 sampling 378/1000ml at 0.29ml/s with 23.3psi vacuum -11.1m deep (-1.7psia) @04:07:00.26 Cartridge 32 sampling 396/1000ml at 0.31ml/s with 22.0psi vacuum -12.6m deep (-4.0psia) @04:08:00.26 Cartridge 32 sampling 414/1000ml at 0.27ml/s with 21.6psi vacuum -11.2m deep (-1.8psia) @04:09:00.26 Cartridge 32 sampling 431/1000ml at 0.28ml/s with 25.6psi vacuum -12.4m deep (-3.6psia) @04:10:00.26 Cartridge 32 sampling 448/1000ml at 0.28ml/s with 21.8psi vacuum -11.1m deep (-1.7psia) @04:11:00.26 Cartridge 32 sampling 464/1000ml at 0.29ml/s with 21.4psi vacuum -12.6m deep (-3.9psia) @04:12:00.26 Cartridge 32 sampling 481/1000ml at 0.28ml/s with 22.0psi vacuum -10.8m deep (-1.3psia) @04:13:00.26 Cartridge 32 sampling 497/1000ml at 0.28ml/s with 21.5psi vacuum -12.9m deep (-4.4psia) @04:14:00.32 Cartridge 32 sampling 512/1000ml at 0.23ml/s with 20.8psi vacuum -10.8m deep (-1.3psia) @04:15:00.26 Cartridge 32 sampling 528/1000ml at 0.27ml/s with 20.1psi vacuum -12.9m deep (-4.4psia) @04:16:00.26 Cartridge 32 sampling 543/1000ml at 0.24ml/s with 22.7psi vacuum -11.1m deep (-1.7psia) @04:17:00.26 Cartridge 32 sampling 558/1000ml at 0.22ml/s with 21.6psi vacuum -12.7m deep (-4.1psia) @04:18:00.26 Cartridge 32 sampling 572/1000ml at 0.23ml/s with 20.3psi vacuum -11.4m deep (-2.1psia) @04:19:00.26 Cartridge 32 sampling 586/1000ml at 0.23ml/s with 18.6psi vacuum -12.8m deep (-4.2psia) @04:20:00.26 Cartridge 32 sampling 600/1000ml at 0.20ml/s with 20.8psi vacuum -11.7m deep (-2.6psia) @04:21:00.26 Cartridge 32 sampling 614/1000ml at 0.21ml/s with 21.2psi vacuum -12.5m deep (-3.8psia) @04:22:00.26 Cartridge 32 sampling 628/1000ml at 0.24ml/s with 22.7psi vacuum -11.8m deep (-2.8psia) @04:23:00.26 Cartridge 32 sampling 641/1000ml at 0.23ml/s with 21.4psi vacuum -11.9m deep (-2.9psia) @04:24:00.26 Cartridge 32 sampling 654/1000ml at 0.22ml/s with 22.5psi vacuum -11.7m deep (-2.6psia) @04:25:00.26 Cartridge 32 sampling 667/1000ml at 0.23ml/s with 22.8psi vacuum -12.7m deep (-4.0psia) @04:26:00.26 Cartridge 32 sampling 680/1000ml at 0.23ml/s with 22.1psi vacuum -11.3m deep (-2.0psia) @04:27:00.26 Cartridge 32 sampling 692/1000ml at 0.22ml/s with 23.1psi vacuum -12.5m deep (-3.7psia) @04:28:00.26 Cartridge 32 sampling 705/1000ml at 0.21ml/s with 25.3psi vacuum -11.7m deep (-2.7psia) @04:29:00.26 Cartridge 32 sampling 717/1000ml at 0.21ml/s with 21.6psi vacuum -12.4m deep (-3.6psia) @04:30:00.55 Cartridge 32 sampling 730/1000ml at 0.21ml/s with 24.0psi vacuum -12.1m deep (-3.2psia) @04:30:09.08 Flow averaged 0.29ml/s over 42:02 @04:30:09.10 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @04:30:09.72 Relieved excess vacuum in 9.1 seconds @04:30:09.74 SP.seek 1000ml,22:52 @04:30:43.11 Flow averaged 0.21ml/s over 34 seconds @04:30:43.14 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @04:30:43.76 Relieved excess vacuum in .9 seconds @04:30:43.78 SP.seek 1000ml,22:17 @04:31:00.26 Cartridge 32 sampling 742/1000ml at 0.21ml/s with 26.0psi vacuum -12.3m deep (-3.5psia) @04:31:29.32 Flow averaged 0.26ml/s over 37 seconds @04:31:29.35 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @04:31:29.97 Relieved excess vacuum in 9.6 seconds @04:31:29.99 SP.seek 1000ml,21:29 @04:31:49.68 Flow averaged 0.32ml/s over 14 seconds @04:31:49.71 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @04:31:50.33 Relieved excess vacuum in 7.3 seconds @04:31:50.35 SP.seek 1000ml,21:08 @04:32:00.26 Cartridge 32 sampling 755/1000ml at 0.21ml/s with 24.5psi vacuum -12.0m deep (-3.0psia) @04:32:05.69 Flow averaged 0.32ml/s over 10 seconds @04:32:05.72 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @04:32:06.34 Relieved excess vacuum in 6.1 seconds @04:32:06.36 SP.seek 1000ml,20:52 @04:32:20.13 Flow averaged 0.22ml/s over 14 seconds @04:32:20.16 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @04:32:20.78 Relieved excess vacuum in 1.4 seconds @04:32:20.80 SP.seek 1000ml,20:38 @04:32:29.93 Flow estimate reduced to 0.18ml/s @04:32:29.94 Intake.close @04:32:29.98 Exhaust.close @04:32:30.82 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @04:32:30.91 Sampled 760.5ml @04:32:30.92 TV.seek :bypass @04:32:32.54 TV.seek :free @04:32:34.20 TV.coast @04:32:35.25 -> Cmd.startProcessing @04:32:35.46 PV.seek :reagent @04:32:36.38 Sample loop closed. Ready to Deliver Reagents @04:32:36.39 ArS.seek :sealed @04:32:40.04 ArS.seek :evac @04:32:54.01 delay 20 seconds @04:33:14.05 ArS.seek :clear @04:33:31.18 RNAlater soak for 10:00 @04:33:31.20 delay 10:00 @04:43:31.24 ArS.seek :tVent @04:43:32.88 delay 1 second @04:43:33.91 ArS.seek :evac @04:43:49.86 delay 10 seconds @04:43:59.90 ArS.seek :tVent @04:44:15.84 delay 1 second @04:44:16.87 ArS.seek :evac @04:44:32.82 delay 10 seconds @04:44:42.85 Sample preserved and evacuated @04:44:43.74 -> Cmd.stop @04:44:44.12 ArS.seek :clear @04:45:01.37 LyS2.seek :free @04:45:01.40 PV.seek :clear @04:45:03.21 Gate.power :motor,:OFF @04:45:03.23 Gate.power :main,:OFF @04:45:03.25 Gate.power :core,:OFF @04:45:03.28 Safely stopped and ready to power off ##-- file closed 2018-01-29T12:59:33.173Z --## ##-- file opened 2018-01-29T12:59:33.174Z --## @04:55:59.43 -> showStatus @04:56:01.43 -> Cmd.loadCartridge @04:56:01.48 Powering core bus @04:56:04.17 ArS.configure ArSconfig @04:56:04.26 LyS1.configure LyS1config @04:56:04.38 LyS2.configure LyS2config @04:56:04.49 AirS.configure AirSconfig @04:56:04.60 TV.configure TVconfig @04:56:04.73 SP.configure SPconfig @04:56:04.84 Sea.configure SPconfig @04:56:04.98 SC.configure SCconfig @04:56:05.09 PV.configure PVconfig @04:56:05.15 All elf controllers running firmware version 4.41 @04:56:05.16 Gate.power :main,:ON,limit to 5000mA @04:56:05.18 Gate.power :motor,:ON,limit to 5000mA @04:56:05.26 Intake.close @04:56:05.30 Exhaust.close @04:56:05.34 PB.close @04:56:05.85 TV.reconfigure TVconfig @04:56:05.90 AirS.reconfigure AirSconfig @04:56:05.94 PV.reconfigure PVconfig @04:56:05.98 LyS1.reconfigure LyS1config @04:56:06.01 LyS2.reconfigure LyS2config @04:56:06.07 ArS.reconfigure ArSconfig @04:56:06.21 TV.home.jog 0 @04:56:06.26 AirS.home.jog 0 @04:56:06.52 PV.home.jog 0 @04:56:06.57 LyS1.home.jog 0 @04:56:06.59 LyS2.home.jog 0 @04:56:06.65 ArS.home.jog 0 @04:56:07.08 TV.reconfigure HomeTV @04:56:07.17 AirS.reconfigure HomeMagSyringe @04:56:07.21 PV.reconfigure HomingPV @04:56:07.35 TV.jog -498 @04:56:07.38 AirS.jog -127 @04:56:07.41 PV.jog -114 @04:56:07.59 LyS1.reconfigure HomeSyringe @04:56:07.62 ArS.reconfigure HomeMagSyringe @04:56:07.65 LyS2.reconfigure HomeSyringe @04:56:07.80 ArS.jog -131 @04:56:07.88 LyS1.jog -112 @04:56:07.91 LyS2.jog -121 @04:56:08.06 PV.setRawPosition! -50 @04:56:08.08 AirS.setRawPosition! -50 @04:56:08.14 PV.seek :home @04:56:08.18 AirS.seek :home @04:56:08.37 ArS.setRawPosition! -50 @04:56:08.39 LyS1.setRawPosition! -50 @04:56:08.49 ArS.seek :home @04:56:08.53 LyS1.seek :home @04:56:08.67 AirS.reconfigure AirSconfig @04:56:08.70 LyS2.setRawPosition! -50 @04:56:08.73 PV.reconfigure PVconfig @04:56:08.86 LyS2.seek :home @04:56:08.94 ArS.reconfigure ArSconfig @04:56:08.96 LyS1.reconfigure LyS1config @04:56:09.14 LyS2.reconfigure LyS2config @04:56:09.22 TV.setRawPosition! 0 @04:56:09.26 TV.seek :home @04:56:09.34 TV.reconfigure TVconfig @04:56:09.46 TV.seek :clear @04:56:11.07 SC.reconfigure HomeSC @04:56:11.14 SC.home.jog 0 @04:56:11.37 Selecting Cartridge slot 31 @04:56:11.91 SC.reconfigure SCconfig @04:56:11.97 SC.seek 31 @04:56:12.35 LyS2.seek :cartridge @04:56:12.38 PV.seek :cartridge @04:56:34.18 -> Cmd.startFiltering @04:56:34.38 Duration of filtering limited to 1:05:00 @04:56:34.56 Priming sample loop w/100ml, bypass w/10ml @04:56:34.58 TV.seek :bypass @04:56:36.19 TV.seek :free @04:56:37.85 TV.coast @04:56:37.90 PB.open @04:56:37.92 Exhaust.close @04:56:38.61 Intake.open @04:56:39.42 Sea @20.4psia @04:56:39.43 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @04:56:44.97 Vacuum tare is 23% of full scale @04:56:45.04 Sea @20.3psia @04:56:45.05 SP.setPosition! 0ml @04:56:45.11 SP.reconfigure SPprime @04:56:45.17 SP.seek 10ml,1:21 @04:56:55.74 PB.close @04:56:55.76 Exhaust.open @04:56:56.65 Sea @19.8psia @04:56:56.66 SP.setPosition! 0ml @04:56:56.72 SP.seek 100ml,8:51 @04:59:00.20 Pressurizing cartridge to 26psi @04:59:00.21 Intake.close @04:59:00.25 Exhaust.close @04:59:01.05 PB.open @04:59:01.73 delay 2 seconds @04:59:03.80 TV.seek :crack @04:59:04.59 TV.seek :free @04:59:05.40 TV.coast @04:59:05.67 Intake.open @04:59:06.45 delay 2 seconds @04:59:08.47 PB.close @04:59:09.21 Sea @19.6psia @04:59:09.22 SP.setPosition! 0ml @04:59:09.28 SP.reconfigure SPcharge @04:59:09.34 SP.seek 5ml,3:46 @04:59:14.57 Cartridge pressurized to 26.4psi @04:59:14.79 Pressure peaked at 26.5psi @04:59:14.81 delay 3 seconds @04:59:17.88 Cartridge at 23.9psi 3 seconds later @04:59:18.01 TV.seek :cartridge @04:59:19.83 TV.seek :free @04:59:21.63 TV.coast @04:59:21.68 Sampling 1000.0ml Exhaust.open @04:59:22.51 Sea @-9.1psia @04:59:22.53 SP.setPosition! 0ml @04:59:22.59 SP.reconfigure SPsample @04:59:22.65 SP.seek 1000ml,1:23:53 @04:59:23.63 Cartridge 31 sampling 0/1000ml at 0.37ml/s with 21.6psi vacuum -11.3m deep (-2.0psia) @05:00:23.63 Cartridge 31 sampling 24/1000ml at 0.41ml/s with 24.0psi vacuum -11.4m deep (-2.1psia) @05:01:23.63 Cartridge 31 sampling 48/1000ml at 0.39ml/s with 24.5psi vacuum -11.0m deep (-1.5psia) @05:02:23.63 Cartridge 31 sampling 71/1000ml at 0.39ml/s with 22.9psi vacuum -11.0m deep (-1.6psia) @05:03:23.63 Cartridge 31 sampling 93/1000ml at 0.37ml/s with 24.4psi vacuum -11.4m deep (-2.1psia) @05:04:23.63 Cartridge 31 sampling 116/1000ml at 0.38ml/s with 24.6psi vacuum -11.1m deep (-1.7psia) @05:05:23.63 Cartridge 31 sampling 138/1000ml at 0.36ml/s with 24.9psi vacuum -11.6m deep (-2.5psia) @05:06:23.63 Cartridge 31 sampling 160/1000ml at 0.37ml/s with 24.4psi vacuum -10.7m deep (-1.1psia) @05:07:23.63 Cartridge 31 sampling 182/1000ml at 0.35ml/s with 25.3psi vacuum -11.9m deep (-2.9psia) @05:08:23.63 Cartridge 31 sampling 203/1000ml at 0.37ml/s with 23.4psi vacuum -10.7m deep (-1.1psia) @05:09:23.63 Cartridge 31 sampling 224/1000ml at 0.35ml/s with 21.5psi vacuum -11.6m deep (-2.4psia) @05:10:23.63 Cartridge 31 sampling 244/1000ml at 0.31ml/s with 21.3psi vacuum -11.4m deep (-2.2psia) @05:11:23.63 Cartridge 31 sampling 264/1000ml at 0.35ml/s with 21.2psi vacuum -11.0m deep (-1.6psia) @05:12:23.63 Cartridge 31 sampling 284/1000ml at 0.32ml/s with 24.1psi vacuum -12.0m deep (-3.0psia) @05:13:23.63 Cartridge 31 sampling 304/1000ml at 0.32ml/s with 24.7psi vacuum -10.9m deep (-1.4psia) @05:14:23.63 Cartridge 31 sampling 323/1000ml at 0.33ml/s with 21.4psi vacuum -11.6m deep (-2.5psia) @05:15:23.63 Cartridge 31 sampling 341/1000ml at 0.29ml/s with 22.7psi vacuum -11.4m deep (-2.2psia) @05:16:23.63 Cartridge 31 sampling 360/1000ml at 0.29ml/s with 23.0psi vacuum -11.6m deep (-2.5psia) @05:17:23.63 Cartridge 31 sampling 378/1000ml at 0.27ml/s with 24.0psi vacuum -11.9m deep (-2.8psia) @05:18:23.63 Cartridge 31 sampling 395/1000ml at 0.31ml/s with 20.0psi vacuum -11.2m deep (-1.8psia) @05:19:23.63 Cartridge 31 sampling 413/1000ml at 0.30ml/s with 21.5psi vacuum -12.1m deep (-3.2psia) @05:20:23.63 Cartridge 31 sampling 430/1000ml at 0.30ml/s with 21.6psi vacuum -11.5m deep (-2.3psia) @05:21:23.63 Cartridge 31 sampling 446/1000ml at 0.29ml/s with 21.9psi vacuum -11.7m deep (-2.7psia) @05:22:23.63 Cartridge 31 sampling 462/1000ml at 0.24ml/s with 21.0psi vacuum -11.7m deep (-2.7psia) @05:23:23.63 Cartridge 31 sampling 478/1000ml at 0.27ml/s with 22.8psi vacuum -11.3m deep (-1.9psia) @05:24:23.63 Cartridge 31 sampling 494/1000ml at 0.25ml/s with 24.4psi vacuum -12.3m deep (-3.6psia) @05:25:23.63 Cartridge 31 sampling 509/1000ml at 0.22ml/s with 20.8psi vacuum -11.6m deep (-2.4psia) @05:26:23.63 Cartridge 31 sampling 524/1000ml at 0.24ml/s with 22.1psi vacuum -12.2m deep (-3.4psia) @05:27:23.63 Cartridge 31 sampling 538/1000ml at 0.22ml/s with 21.4psi vacuum -11.8m deep (-2.7psia) @05:28:23.63 Cartridge 31 sampling 553/1000ml at 0.23ml/s with 22.4psi vacuum -11.9m deep (-2.9psia) @05:29:23.63 Cartridge 31 sampling 567/1000ml at 0.21ml/s with 20.7psi vacuum -12.0m deep (-3.0psia) @05:30:23.63 Cartridge 31 sampling 580/1000ml at 0.23ml/s with 22.6psi vacuum -11.9m deep (-2.9psia) @05:31:23.63 Cartridge 31 sampling 593/1000ml at 0.20ml/s with 21.4psi vacuum -12.3m deep (-3.5psia) @05:32:23.63 Cartridge 31 sampling 607/1000ml at 0.21ml/s with 20.8psi vacuum -11.8m deep (-2.8psia) @05:33:23.63 Cartridge 31 sampling 619/1000ml at 0.20ml/s with 24.0psi vacuum -12.9m deep (-4.4psia) @05:34:23.63 Cartridge 31 sampling 632/1000ml at 0.21ml/s with 21.9psi vacuum -11.7m deep (-2.6psia) @05:35:23.63 Cartridge 31 sampling 645/1000ml at 0.21ml/s with 22.3psi vacuum -12.0m deep (-3.0psia) @05:36:23.63 Cartridge 31 sampling 657/1000ml at 0.20ml/s with 23.2psi vacuum -12.4m deep (-3.6psia) @05:37:23.63 Cartridge 31 sampling 670/1000ml at 0.20ml/s with 23.0psi vacuum -11.4m deep (-2.1psia) @05:37:59.99 Flow averaged 0.29ml/s over 38:32 @05:38:00.01 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @05:38:00.63 Relieved excess vacuum in 6.9 seconds @05:38:00.65 SP.seek 1000ml,27:24 @05:38:23.16 Flow averaged 0.37ml/s over 14 seconds @05:38:23.48 Waiting up to 11 seconds for vacuum to reduce from 26.2 to 18.0psi @05:38:23.62 Cartridge 31 sampling 682/1000ml at 0.00ml/s with 0.1psi vacuum 3.5m deep (19.9psia) @05:38:24.10 Relieved excess vacuum in 10.4 seconds @05:38:24.12 SP.seek 1000ml,27:00 @05:39:09.90 Flow averaged 0.22ml/s over 44 seconds @05:39:09.92 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @05:39:10.54 Relieved excess vacuum in 3.3 seconds @05:39:10.56 SP.seek 1000ml,26:12 @05:39:18.14 Flow estimate reduced to 0.18ml/s @05:39:18.16 Intake.close @05:39:18.19 Exhaust.close @05:39:19.03 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @05:39:19.12 Sampled 693.5ml @05:39:19.14 TV.seek :bypass @05:39:20.74 TV.seek :free @05:39:22.40 TV.coast @05:39:23.49 -> Cmd.startProcessing @05:39:23.71 PV.seek :reagent @05:39:24.62 Sample loop closed. Ready to Deliver Reagents @05:39:24.64 ArS.seek :sealed @05:39:28.27 ArS.seek :evac @05:39:42.22 delay 20 seconds @05:40:02.25 ArS.seek :clear @05:40:19.35 RNAlater soak for 10:00 @05:40:19.37 delay 10:00 @05:50:19.40 ArS.seek :tVent @05:50:21.04 delay 1 second @05:50:22.07 ArS.seek :evac @05:50:38.01 delay 10 seconds @05:50:48.05 ArS.seek :tVent @05:51:03.99 delay 1 second @05:51:05.02 ArS.seek :evac @05:51:20.96 delay 10 seconds @05:51:31.00 Sample preserved and evacuated @05:51:31.98 -> Cmd.stop @05:51:32.35 ArS.seek :clear @05:51:49.59 PV.seek :clear @05:51:49.61 LyS2.seek :free @05:51:51.46 Gate.power :motor,:OFF @05:51:51.48 Gate.power :main,:OFF @05:51:51.50 Gate.power :core,:OFF @05:51:51.52 Safely stopped and ready to power off ##-- file closed 2018-01-29T14:14:41.198Z --## ##-- file opened 2018-01-29T14:14:41.199Z --## @06:11:00.52 -> showStatus @06:11:02.52 -> Cmd.loadCartridge @06:11:02.56 Powering core bus @06:11:05.25 ArS.configure ArSconfig @06:11:05.35 LyS1.configure LyS1config @06:11:05.46 LyS2.configure LyS2config @06:11:05.57 AirS.configure AirSconfig @06:11:05.68 TV.configure TVconfig @06:11:05.80 SP.configure SPconfig @06:11:05.92 Sea.configure SPconfig @06:11:06.05 SC.configure SCconfig @06:11:06.18 PV.configure PVconfig @06:11:06.24 All elf controllers running firmware version 4.41 @06:11:06.25 Gate.power :main,:ON,limit to 5000mA @06:11:06.27 Gate.power :motor,:ON,limit to 5000mA @06:11:06.35 Intake.close @06:11:06.39 Exhaust.close @06:11:06.42 PB.close @06:11:06.99 TV.reconfigure TVconfig @06:11:07.02 AirS.reconfigure AirSconfig @06:11:07.05 LyS1.reconfigure LyS1config @06:11:07.09 PV.reconfigure PVconfig @06:11:07.12 LyS2.reconfigure LyS2config @06:11:07.16 ArS.reconfigure ArSconfig @06:11:07.34 AirS.home.jog 0 @06:11:07.37 PV.home.jog 0 @06:11:07.62 TV.home.jog 0 @06:11:07.65 LyS1.home.jog 0 @06:11:07.68 ArS.home.jog 0 @06:11:07.71 LyS2.home.jog 0 @06:11:08.16 TV.reconfigure HomeTV @06:11:08.18 AirS.reconfigure HomeMagSyringe @06:11:08.27 PV.reconfigure HomingPV @06:11:08.42 TV.jog -499 @06:11:08.45 AirS.jog -127 @06:11:08.48 PV.jog -115 @06:11:08.65 LyS1.reconfigure HomeSyringe @06:11:08.69 ArS.reconfigure HomeMagSyringe @06:11:08.72 LyS2.reconfigure HomeSyringe @06:11:08.90 ArS.jog -126 @06:11:08.96 LyS2.jog -123 @06:11:08.99 LyS1.jog -114 @06:11:09.12 PV.setRawPosition! -50 @06:11:09.14 AirS.setRawPosition! -50 @06:11:09.20 PV.seek :home @06:11:09.24 AirS.seek :home @06:11:09.41 ArS.setRawPosition! -50 @06:11:09.46 ArS.seek :home @06:11:09.57 PV.reconfigure PVconfig @06:11:09.60 AirS.reconfigure AirSconfig @06:11:09.63 LyS2.setRawPosition! -50 @06:11:09.66 LyS1.setRawPosition! -50 @06:11:09.80 LyS1.seek :home @06:11:09.83 LyS2.seek :home @06:11:09.95 ArS.reconfigure ArSconfig @06:11:10.14 LyS1.reconfigure LyS1config @06:11:10.21 LyS2.reconfigure LyS2config @06:11:10.29 TV.setRawPosition! 0 @06:11:10.33 TV.seek :home @06:11:10.42 TV.reconfigure TVconfig @06:11:10.53 TV.seek :clear @06:11:12.15 SC.reconfigure HomeSC @06:11:12.21 SC.home.jog 0 @06:11:12.43 Selecting Cartridge slot 30 @06:11:12.98 SC.reconfigure SCconfig @06:11:13.04 SC.seek 30 @06:11:13.41 LyS2.seek :cartridge @06:11:13.45 PV.seek :cartridge @06:11:35.26 -> Cmd.startFiltering @06:11:35.45 Duration of filtering limited to 1:05:00 @06:11:35.64 Priming sample loop w/100ml, bypass w/10ml @06:11:35.65 TV.seek :bypass @06:11:37.26 TV.seek :free @06:11:38.92 TV.coast @06:11:38.96 PB.open @06:11:38.98 Exhaust.close @06:11:39.67 Intake.open @06:11:40.46 Sea @24.3psia @06:11:40.47 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @06:11:46.00 Vacuum tare is 23% of full scale @06:11:46.07 Sea @24.1psia @06:11:46.09 SP.setPosition! 0ml @06:11:46.14 SP.reconfigure SPprime @06:11:46.21 SP.seek 10ml,1:21 @06:11:56.78 PB.close @06:11:56.80 Exhaust.open @06:11:57.65 Sea @23.7psia @06:11:57.67 SP.setPosition! 0ml @06:11:57.72 SP.seek 100ml,8:51 @06:14:01.10 Pressurizing cartridge to 26psi @06:14:01.11 Intake.close @06:14:01.15 Exhaust.close @06:14:01.92 PB.open @06:14:02.63 delay 2 seconds @06:14:04.70 TV.seek :crack @06:14:05.50 TV.seek :free @06:14:06.29 TV.coast @06:14:06.34 Intake.open @06:14:07.36 delay 2 seconds @06:14:09.38 PB.close @06:14:10.13 Sea @24.1psia @06:14:10.14 SP.setPosition! 0ml @06:14:10.19 SP.reconfigure SPcharge @06:14:10.26 SP.seek 5ml,3:46 @06:14:15.20 Cartridge pressurized to 26.3psi @06:14:15.43 delay 3 seconds @06:14:18.50 Cartridge at 23.5psi 3 seconds later @06:14:18.63 TV.seek :cartridge @06:14:20.44 TV.seek :free @06:14:22.24 TV.coast @06:14:22.29 Sampling 1000.0ml @06:14:22.30 Exhaust.open @06:14:23.14 Sea @-1.5psia @06:14:23.16 SP.setPosition! 0ml @06:14:23.21 SP.reconfigure SPsample @06:14:23.28 SP.seek 1000ml,1:23:53 @06:14:24.25 Cartridge 30 sampling 0/1000ml at 0.37ml/s with 23.5psi vacuum -8.8m deep (1.7psia) @06:15:24.26 Cartridge 30 sampling 23/1000ml at 0.37ml/s with 23.7psi vacuum -8.3m deep (2.4psia) @06:16:24.26 Cartridge 30 sampling 46/1000ml at 0.36ml/s with 24.2psi vacuum -8.6m deep (1.9psia) @06:17:24.26 Cartridge 30 sampling 68/1000ml at 0.34ml/s with 22.3psi vacuum -8.4m deep (2.3psia) @06:18:24.26 Cartridge 30 sampling 89/1000ml at 0.34ml/s with 22.9psi vacuum -9.1m deep (1.2psia) @06:19:24.26 Cartridge 30 sampling 111/1000ml at 0.36ml/s with 20.9psi vacuum -8.3m deep (2.4psia) @06:20:24.26 Cartridge 30 sampling 132/1000ml at 0.35ml/s with 23.6psi vacuum -8.6m deep (2.0psia) @06:21:24.26 Cartridge 30 sampling 152/1000ml at 0.32ml/s with 23.4psi vacuum -8.8m deep (1.6psia) @06:22:24.26 Cartridge 30 sampling 172/1000ml at 0.35ml/s with 22.5psi vacuum -8.2m deep (2.6psia) @06:23:24.26 Cartridge 30 sampling 192/1000ml at 0.32ml/s with 23.8psi vacuum -8.8m deep (1.7psia) @06:24:24.26 Cartridge 30 sampling 212/1000ml at 0.32ml/s with 19.9psi vacuum -9.6m deep (0.5psia) @06:25:24.26 Cartridge 30 sampling 231/1000ml at 0.30ml/s with 20.1psi vacuum -8.2m deep (2.6psia) @06:26:24.26 Cartridge 30 sampling 250/1000ml at 0.31ml/s with 21.7psi vacuum -9.3m deep (0.9psia) @06:27:24.26 Cartridge 30 sampling 268/1000ml at 0.32ml/s with 19.9psi vacuum -8.8m deep (1.7psia) @06:28:24.26 Cartridge 30 sampling 286/1000ml at 0.31ml/s with 25.3psi vacuum -8.6m deep (2.0psia) @06:29:24.26 Cartridge 30 sampling 304/1000ml at 0.28ml/s with 21.9psi vacuum -8.8m deep (1.7psia) @06:30:24.26 Cartridge 30 sampling 321/1000ml at 0.27ml/s with 21.7psi vacuum -9.3m deep (1.0psia) @06:31:24.26 Cartridge 30 sampling 338/1000ml at 0.27ml/s with 21.9psi vacuum -9.0m deep (1.4psia) @06:32:24.26 Cartridge 30 sampling 355/1000ml at 0.26ml/s with 20.0psi vacuum -9.3m deep (0.9psia) @06:33:24.26 Cartridge 30 sampling 372/1000ml at 0.27ml/s with 21.4psi vacuum -9.5m deep (0.6psia) @06:34:24.26 Cartridge 30 sampling 388/1000ml at 0.25ml/s with 20.6psi vacuum -8.6m deep (2.0psia) @06:35:24.26 Cartridge 30 sampling 404/1000ml at 0.26ml/s with 23.1psi vacuum -10.1m deep (-0.2psia) @06:36:24.26 Cartridge 30 sampling 419/1000ml at 0.24ml/s with 20.9psi vacuum -9.4m deep (0.8psia) @06:37:24.26 Cartridge 30 sampling 434/1000ml at 0.24ml/s with 22.0psi vacuum -9.4m deep (0.8psia) @06:38:24.26 Cartridge 30 sampling 449/1000ml at 0.23ml/s with 20.6psi vacuum -9.1m deep (1.2psia) @06:39:24.26 Cartridge 30 sampling 464/1000ml at 0.24ml/s with 19.2psi vacuum -9.7m deep (0.4psia) @06:40:24.26 Cartridge 30 sampling 478/1000ml at 0.25ml/s with 22.0psi vacuum -8.9m deep (1.6psia) @06:41:24.26 Cartridge 30 sampling 492/1000ml at 0.22ml/s with 20.7psi vacuum -10.1m deep (-0.2psia) @06:42:24.26 Cartridge 30 sampling 505/1000ml at 0.22ml/s with 25.1psi vacuum -8.7m deep (1.8psia) @06:43:24.26 Cartridge 30 sampling 519/1000ml at 0.20ml/s with 22.5psi vacuum -9.6m deep (0.5psia) @06:44:24.26 Cartridge 30 sampling 532/1000ml at 0.23ml/s with 23.1psi vacuum -9.2m deep (1.1psia) @06:45:24.26 Cartridge 30 sampling 545/1000ml at 0.21ml/s with 22.0psi vacuum -9.1m deep (1.3psia) @06:46:24.26 Cartridge 30 sampling 558/1000ml at 0.22ml/s with 22.2psi vacuum -9.7m deep (0.3psia) @06:47:24.26 Cartridge 30 sampling 571/1000ml at 0.21ml/s with 24.2psi vacuum -9.2m deep (1.0psia) @06:48:24.26 Cartridge 30 sampling 583/1000ml at 0.21ml/s with 21.8psi vacuum -9.4m deep (0.7psia) @06:49:24.26 Cartridge 30 sampling 596/1000ml at 0.21ml/s with 25.2psi vacuum -9.2m deep (1.1psia) @06:50:24.26 Cartridge 30 sampling 608/1000ml at 0.21ml/s with 25.7psi vacuum -9.2m deep (1.1psia) @06:51:22.96 Flow averaged 0.28ml/s over 36:55 @06:51:22.99 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @06:51:23.60 Relieved excess vacuum in 6.2 seconds @06:51:23.63 SP.seek 1000ml,32:08 @06:51:24.25 Cartridge 30 sampling 621/1000ml at 0.20ml/s with 25.2psi vacuum -9.5m deep (0.6psia) @06:51:26.69 Flow estimate reduced to 0.22ml/s @06:51:26.71 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @06:51:27.33 Relieved excess vacuum in 3.1 seconds @06:51:27.66 SP.seek 1000ml,32:04 @06:52:01.20 Flow averaged 0.21ml/s over 34 seconds @06:52:01.23 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @06:52:01.85 Relieved excess vacuum in 1.1 seconds @06:52:01.87 SP.seek 1000ml,31:29 @06:52:04.93 Flow estimate reduced to 0.17ml/s @06:52:04.94 Intake.close @06:52:04.98 Exhaust.close @06:52:05.77 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @06:52:05.86 Sampled 629.0ml @06:52:05.87 TV.seek :bypass @06:52:07.49 TV.seek :free @06:52:09.15 TV.coast @06:52:10.23 -> Cmd.startProcessing @06:52:10.43 PV.seek :reagent @06:52:11.34 Sample loop closed. Ready to Deliver Reagents @06:52:11.35 ArS.seek :sealed @06:52:15.00 ArS.seek :evac @06:52:28.96 delay 20 seconds @06:52:48.98 ArS.seek :clear @06:53:06.11 RNAlater soak for 10:00 @06:53:06.12 delay 10:00 @07:03:06.16 ArS.seek :tVent @07:03:07.82 delay 1 second @07:03:08.84 ArS.seek :evac @07:03:24.79 delay 10 seconds @07:03:34.81 ArS.seek :tVent @07:03:50.77 delay 1 second @07:03:51.79 ArS.seek :evac @07:04:07.74 delay 10 seconds @07:04:17.77 Sample preserved and evacuated @07:04:18.73 -> Cmd.stop @07:04:19.09 ArS.seek :clear @07:04:36.35 PV.seek :clear @07:04:36.38 LyS2.seek :free @07:04:38.21 Gate.power :motor,:OFF @07:04:38.23 Gate.power :main,:OFF @07:04:38.25 Gate.power :core,:OFF @07:04:38.27 Safely stopped and ready to power off ##-- file closed 2018-01-29T15:20:25.913Z --## ##-- file opened 2018-01-29T15:20:25.914Z --## @07:16:39.15 -> showStatus @07:16:41.14 -> Cmd.loadCartridge @07:16:41.19 Powering core bus @07:16:43.88 ArS.configure ArSconfig @07:16:43.98 LyS1.configure LyS1config @07:16:44.09 LyS2.configure LyS2config @07:16:44.20 AirS.configure AirSconfig @07:16:44.32 TV.configure TVconfig @07:16:44.43 SP.configure SPconfig @07:16:44.55 Sea.configure SPconfig @07:16:44.69 SC.configure SCconfig @07:16:44.80 PV.configure PVconfig @07:16:44.86 All elf controllers running firmware version 4.41 @07:16:44.88 Gate.power :main,:ON,limit to 5000mA @07:16:44.90 Gate.power :motor,:ON,limit to 5000mA @07:16:44.99 Exhaust.close @07:16:45.01 Intake.close @07:16:45.04 PB.close @07:16:45.59 TV.reconfigure TVconfig @07:16:45.61 AirS.reconfigure AirSconfig @07:16:45.64 LyS1.reconfigure LyS1config @07:16:45.68 PV.reconfigure PVconfig @07:16:45.74 ArS.reconfigure ArSconfig @07:16:45.80 LyS2.reconfigure LyS2config @07:16:45.94 TV.home.jog 0 @07:16:46.24 LyS1.home.jog 0 @07:16:46.27 AirS.home.jog 0 @07:16:46.30 PV.home.jog 0 @07:16:46.33 ArS.home.jog 0 @07:16:46.37 LyS2.home.jog 0 @07:16:46.81 TV.reconfigure HomeTV @07:16:46.87 AirS.reconfigure HomeMagSyringe @07:16:46.93 LyS1.reconfigure HomeSyringe @07:16:46.99 PV.reconfigure HomingPV @07:16:47.15 TV.jog -499 @07:16:47.18 PV.jog -116 @07:16:47.20 AirS.jog -126 @07:16:47.23 LyS1.jog -113 @07:16:47.43 ArS.reconfigure HomeMagSyringe @07:16:47.46 LyS2.reconfigure HomeSyringe @07:16:47.54 ArS.jog -127 @07:16:47.57 LyS2.jog -120 @07:16:47.70 AirS.setRawPosition! -50 @07:16:47.72 LyS1.setRawPosition! -50 @07:16:47.82 AirS.seek :home @07:16:47.88 LyS1.seek :home @07:16:48.02 PV.setRawPosition! -50 @07:16:48.04 LyS2.setRawPosition! -50 @07:16:48.06 ArS.setRawPosition! -50 @07:16:48.16 PV.seek :home @07:16:48.20 LyS2.seek :home @07:16:48.29 ArS.seek :home @07:16:48.41 LyS1.reconfigure LyS1config @07:16:48.43 AirS.reconfigure AirSconfig @07:16:48.59 PV.reconfigure PVconfig @07:16:48.60 LyS2.reconfigure LyS2config @07:16:48.71 ArS.reconfigure ArSconfig @07:16:48.97 TV.setRawPosition! 0 @07:16:49.02 TV.seek :home @07:16:49.10 TV.reconfigure TVconfig @07:16:49.22 TV.seek :clear @07:16:50.84 SC.reconfigure HomeSC @07:16:50.90 SC.home.jog 0 @07:16:51.13 Selecting Cartridge slot 29 @07:16:51.67 SC.reconfigure SCconfig @07:16:51.73 SC.seek 29 @07:16:52.11 LyS2.seek :cartridge @07:16:52.15 PV.seek :cartridge @07:17:13.49 -> Cmd.startFiltering @07:17:13.68 Duration of filtering limited to 1:05:00 @07:17:13.88 Priming sample loop w/100ml, bypass w/10ml @07:17:13.90 TV.seek :bypass @07:17:15.51 TV.seek :free @07:17:17.16 TV.coast @07:17:17.21 PB.open @07:17:17.22 Exhaust.close @07:17:17.96 Intake.open @07:17:18.82 Sea @24.1psia @07:17:18.83 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @07:17:24.36 Vacuum tare is 23% of full scale @07:17:24.43 Sea @23.9psia @07:17:24.45 SP.setPosition! 0ml @07:17:24.50 SP.reconfigure SPprime @07:17:24.56 SP.seek 10ml,1:21 @07:17:35.13 PB.close @07:17:35.16 Exhaust.open @07:17:36.00 Sea @23.5psia @07:17:36.02 SP.setPosition! 0ml @07:17:36.07 SP.seek 100ml,8:51 @07:19:39.42 Pressurizing cartridge to 26psi @07:19:39.43 Intake.close @07:19:39.46 Exhaust.close @07:19:40.25 PB.open @07:19:40.95 delay 2 seconds @07:19:43.03 TV.seek :crack @07:19:43.82 TV.seek :free @07:19:44.63 TV.coast @07:19:44.67 Intake.open @07:19:45.46 delay 2 seconds @07:19:47.49 PB.close @07:19:48.26 Sea @23.3psia @07:19:48.28 SP.setPosition! 0ml @07:19:48.33 SP.reconfigure SPcharge @07:19:48.40 SP.seek 5ml,3:46 @07:19:53.60 Cartridge pressurized to 26.3psi @07:19:53.83 Pressure peaked at 26.4psi @07:19:53.84 delay 3 seconds @07:19:56.91 Cartridge at 23.4psi 3 seconds later @07:19:57.04 TV.seek :cartridge @07:19:58.86 TV.seek :free @07:20:00.66 TV.coast @07:20:00.71 Sampling 1000.0ml @07:20:00.72 Exhaust.open @07:20:01.53 Sea @-5.3psia @07:20:01.55 SP.setPosition! 0ml @07:20:01.60 SP.reconfigure SPsample @07:20:01.66 SP.seek 1000ml,1:23:53 @07:20:02.64 Cartridge 29 sampling 0/1000ml at 0.38ml/s with 19.1psi vacuum -9.0m deep (1.4psia) @07:21:02.65 Cartridge 29 sampling 24/1000ml at 0.39ml/s with 25.0psi vacuum -8.1m deep (2.7psia) @07:22:02.65 Cartridge 29 sampling 48/1000ml at 0.38ml/s with 20.8psi vacuum -9.4m deep (0.9psia) @07:23:02.65 Cartridge 29 sampling 71/1000ml at 0.40ml/s with 21.5psi vacuum -8.2m deep (2.6psia) @07:24:02.65 Cartridge 29 sampling 94/1000ml at 0.37ml/s with 24.3psi vacuum -9.3m deep (1.0psia) @07:25:02.65 Cartridge 29 sampling 116/1000ml at 0.37ml/s with 22.2psi vacuum -9.0m deep (1.4psia) @07:26:02.65 Cartridge 29 sampling 138/1000ml at 0.37ml/s with 25.2psi vacuum -8.6m deep (1.9psia) @07:27:02.65 Cartridge 29 sampling 160/1000ml at 0.37ml/s with 20.7psi vacuum -8.8m deep (1.6psia) @07:28:02.65 Cartridge 29 sampling 182/1000ml at 0.35ml/s with 22.9psi vacuum -9.3m deep (1.0psia) @07:29:02.65 Cartridge 29 sampling 203/1000ml at 0.35ml/s with 21.3psi vacuum -8.3m deep (2.4psia) @07:30:02.65 Cartridge 29 sampling 224/1000ml at 0.35ml/s with 20.9psi vacuum -10.1m deep (-0.2psia) @07:31:02.65 Cartridge 29 sampling 244/1000ml at 0.34ml/s with 21.7psi vacuum -8.5m deep (2.2psia) @07:32:02.65 Cartridge 29 sampling 264/1000ml at 0.34ml/s with 23.3psi vacuum -9.4m deep (0.8psia) @07:33:02.65 Cartridge 29 sampling 284/1000ml at 0.34ml/s with 21.5psi vacuum -9.2m deep (1.0psia) @07:34:02.65 Cartridge 29 sampling 303/1000ml at 0.33ml/s with 21.1psi vacuum -8.8m deep (1.7psia) @07:35:02.65 Cartridge 29 sampling 322/1000ml at 0.29ml/s with 18.9psi vacuum -9.6m deep (0.5psia) @07:36:02.65 Cartridge 29 sampling 341/1000ml at 0.32ml/s with 21.4psi vacuum -8.6m deep (2.0psia) @07:37:02.65 Cartridge 29 sampling 359/1000ml at 0.32ml/s with 21.3psi vacuum -9.3m deep (0.9psia) @07:38:02.65 Cartridge 29 sampling 377/1000ml at 0.28ml/s with 18.0psi vacuum -8.6m deep (2.0psia) @07:39:02.65 Cartridge 29 sampling 394/1000ml at 0.30ml/s with 23.6psi vacuum -10.0m deep (-0.1psia) @07:40:02.65 Cartridge 29 sampling 411/1000ml at 0.30ml/s with 23.8psi vacuum -8.3m deep (2.4psia) @07:41:02.65 Cartridge 29 sampling 428/1000ml at 0.28ml/s with 21.9psi vacuum -9.6m deep (0.5psia) @07:42:02.65 Cartridge 29 sampling 444/1000ml at 0.25ml/s with 21.2psi vacuum -9.1m deep (1.3psia) @07:43:02.65 Cartridge 29 sampling 460/1000ml at 0.25ml/s with 20.4psi vacuum -9.2m deep (1.0psia) @07:44:02.65 Cartridge 29 sampling 476/1000ml at 0.24ml/s with 21.0psi vacuum -10.3m deep (-0.6psia) @07:45:02.65 Cartridge 29 sampling 491/1000ml at 0.23ml/s with 22.0psi vacuum -8.5m deep (2.1psia) @07:46:02.65 Cartridge 29 sampling 506/1000ml at 0.25ml/s with 22.3psi vacuum -10.4m deep (-0.7psia) @07:47:02.64 Cartridge 29 sampling 521/1000ml at 0.23ml/s with 21.1psi vacuum -8.6m deep (2.0psia) @07:48:02.65 Cartridge 29 sampling 535/1000ml at 0.24ml/s with 19.1psi vacuum -10.1m deep (-0.2psia) @07:49:02.65 Cartridge 29 sampling 549/1000ml at 0.24ml/s with 21.4psi vacuum -9.0m deep (1.4psia) @07:50:02.64 Cartridge 29 sampling 562/1000ml at 0.21ml/s with 21.1psi vacuum -9.7m deep (0.4psia) @07:51:02.65 Cartridge 29 sampling 576/1000ml at 0.23ml/s with 22.4psi vacuum -8.8m deep (1.7psia) @07:52:02.65 Cartridge 29 sampling 589/1000ml at 0.22ml/s with 22.9psi vacuum -10.2m deep (-0.4psia) @07:53:02.65 Cartridge 29 sampling 602/1000ml at 0.21ml/s with 20.1psi vacuum -9.1m deep (1.2psia) @07:54:02.65 Cartridge 29 sampling 614/1000ml at 0.21ml/s with 24.1psi vacuum -9.5m deep (0.6psia) @07:55:02.65 Cartridge 29 sampling 627/1000ml at 0.21ml/s with 25.3psi vacuum -10.1m deep (-0.2psia) @07:56:02.65 Cartridge 29 sampling 640/1000ml at 0.20ml/s with 23.6psi vacuum -9.0m deep (1.4psia) @07:57:02.65 Cartridge 29 sampling 652/1000ml at 0.21ml/s with 24.1psi vacuum -10.0m deep (-0.0psia) @07:57:27.36 Flow averaged 0.29ml/s over 37:22 @07:57:27.38 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @07:57:28.00 Relieved excess vacuum in 5.3 seconds @07:57:28.03 SP.seek 1000ml,29:04 @07:58:02.64 Cartridge 29 sampling 665/1000ml at 0.21ml/s with 27.0psi vacuum -9.2m deep (1.1psia) @07:58:05.81 Flow averaged 0.23ml/s over 35 seconds @07:58:05.83 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @07:58:06.77 Relieved excess vacuum in 4.1 seconds @07:58:06.80 SP.seek 1000ml,28:24 @07:58:41.77 Flow averaged 0.22ml/s over 34 seconds @07:58:41.79 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @07:58:42.41 Relieved excess vacuum in 2.5 seconds @07:58:42.44 SP.seek 1000ml,27:47 @07:59:02.65 Cartridge 29 sampling 677/1000ml at 0.20ml/s with 21.8psi vacuum -9.5m deep (0.6psia) @07:59:37.17 Flow averaged 0.23ml/s over 51 seconds @07:59:37.19 Waiting up to 11 seconds for vacuum to reduce from 26.2 to 18.0psi @07:59:37.81 Relieved excess vacuum in 5.1 seconds @07:59:37.84 SP.seek 1000ml,26:50 @07:59:45.46 Flow estimate reduced to 0.18ml/s @07:59:45.47 Intake.close @07:59:45.51 Exhaust.close @07:59:46.31 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @07:59:46.40 Sampled 685.8ml @07:59:46.42 TV.seek :bypass @07:59:48.04 TV.seek :free @07:59:49.70 TV.coast @07:59:50.82 -> Cmd.startProcessing @07:59:51.05 PV.seek :reagent @07:59:51.96 Sample loop closed. Ready to Deliver Reagents @07:59:51.97 ArS.seek :sealed @07:59:55.62 ArS.seek :evac @08:00:09.57 delay 20 seconds @08:00:29.61 ArS.seek :clear @08:00:46.73 RNAlater soak for 10:00 @08:00:46.74 delay 10:00 @08:10:46.78 ArS.seek :tVent @08:10:48.42 delay 1 second @08:10:49.45 ArS.seek :evac @08:11:05.39 delay 10 seconds @08:11:15.43 ArS.seek :tVent @08:11:31.37 delay 1 second @08:11:32.40 ArS.seek :evac @08:11:48.34 delay 10 seconds @08:11:58.38 Sample preserved and evacuated @08:11:59.31 -> Cmd.stop @08:11:59.68 ArS.seek :clear @08:12:16.93 PV.seek :clear @08:12:16.96 LyS2.seek :free @08:12:18.79 Gate.power :motor,:OFF @08:12:18.82 Gate.power :main,:OFF @08:12:18.84 Gate.power :core,:OFF @08:12:18.86 Safely stopped and ready to power off ##-- file closed 2018-01-29T16:27:22.317Z --## ##-- file opened 2018-01-29T16:27:22.319Z --## @08:23:29.37 -> showStatus @08:23:31.37 -> Cmd.loadCartridge @08:23:31.41 Powering core bus @08:23:34.10 ArS.configure ArSconfig @08:23:34.20 LyS1.configure LyS1config @08:23:34.32 LyS2.configure LyS2config @08:23:34.41 AirS.configure AirSconfig @08:23:34.53 TV.configure TVconfig @08:23:34.65 SP.configure SPconfig @08:23:34.77 Sea.configure SPconfig @08:23:34.91 SC.configure SCconfig @08:23:35.03 PV.configure PVconfig @08:23:35.09 All elf controllers running firmware version 4.41 @08:23:35.10 Gate.power :main,:ON,limit to 5000mA @08:23:35.13 Gate.power :motor,:ON,limit to 5000mA @08:23:35.20 Intake.close @08:23:35.24 Exhaust.close @08:23:35.27 PB.close @08:23:35.75 TV.reconfigure TVconfig @08:23:35.78 AirS.reconfigure AirSconfig @08:23:35.82 LyS1.reconfigure LyS1config @08:23:35.85 PV.reconfigure PVconfig @08:23:35.89 ArS.reconfigure ArSconfig @08:23:35.98 LyS2.reconfigure LyS2config @08:23:36.12 TV.home.jog 0 @08:23:36.15 LyS1.home.jog 0 @08:23:36.19 AirS.home.jog 0 @08:23:36.22 PV.home.jog 0 @08:23:36.46 ArS.home.jog 0 @08:23:36.58 LyS2.home.jog 0 @08:23:37.05 TV.reconfigure HomeTV @08:23:37.08 AirS.reconfigure HomeMagSyringe @08:23:37.12 LyS1.reconfigure HomeSyringe @08:23:37.18 PV.reconfigure HomingPV @08:23:37.35 TV.jog -502 @08:23:37.40 LyS1.jog -113 @08:23:37.43 PV.jog -116 @08:23:37.46 AirS.jog -127 @08:23:37.64 ArS.reconfigure HomeMagSyringe @08:23:37.66 LyS2.reconfigure HomeSyringe @08:23:37.77 ArS.jog -129 @08:23:37.83 LyS2.jog -119 @08:23:37.99 PV.setRawPosition! -50 @08:23:38.01 AirS.setRawPosition! -50 @08:23:38.03 LyS1.setRawPosition! -50 @08:23:38.12 AirS.seek :home @08:23:38.16 PV.seek :home @08:23:38.19 LyS1.seek :home @08:23:38.39 LyS2.setRawPosition! -50 @08:23:38.41 ArS.setRawPosition! -50 @08:23:38.48 LyS2.seek :home @08:23:38.53 ArS.seek :home @08:23:38.68 AirS.reconfigure AirSconfig @08:23:38.71 LyS1.reconfigure LyS1config @08:23:38.74 PV.reconfigure PVconfig @08:23:38.90 ArS.reconfigure ArSconfig @08:23:38.93 LyS2.reconfigure LyS2config @08:23:39.19 TV.setRawPosition! 0 @08:23:39.23 TV.seek :home @08:23:39.32 TV.reconfigure TVconfig @08:23:39.43 TV.seek :clear @08:23:41.05 SC.reconfigure HomeSC @08:23:41.11 SC.home.jog 0 @08:23:41.35 Selecting Cartridge slot 28 @08:23:41.89 SC.reconfigure SCconfig @08:23:41.95 SC.seek 28 @08:23:42.33 LyS2.seek :cartridge @08:23:42.37 PV.seek :cartridge @08:24:04.12 -> Cmd.startFiltering @08:24:04.31 Duration of filtering limited to 1:05:00 @08:24:04.50 Priming sample loop w/100ml, bypass w/10ml @08:24:04.52 TV.seek :bypass @08:24:06.14 TV.seek :free @08:24:07.80 TV.coast @08:24:07.84 PB.open @08:24:07.86 Exhaust.close @08:24:08.59 Intake.open @08:24:09.44 Sea @23.6psia @08:24:09.45 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @08:24:14.98 Vacuum tare is 23% of full scale @08:24:15.05 Sea @23.2psia @08:24:15.07 SP.setPosition! 0ml @08:24:15.12 SP.reconfigure SPprime @08:24:15.19 SP.seek 10ml,1:21 @08:24:25.77 PB.close @08:24:25.79 Exhaust.open @08:24:26.69 Sea @22.7psia @08:24:26.70 SP.setPosition! 0ml @08:24:26.76 SP.seek 100ml,8:51 @08:26:29.90 Pressurizing cartridge to 26psi @08:26:29.91 Intake.close @08:26:29.95 Exhaust.close @08:26:30.77 PB.open @08:26:31.49 delay 2 seconds @08:26:33.56 TV.seek :crack @08:26:34.35 TV.seek :free @08:26:35.16 TV.coast @08:26:35.20 Intake.open @08:26:36.27 delay 2 seconds @08:26:38.29 PB.close @08:26:39.08 Sea @23.0psia @08:26:39.09 SP.setPosition! 0ml @08:26:39.14 SP.reconfigure SPcharge @08:26:39.21 SP.seek 5ml,3:46 @08:26:44.34 Cartridge pressurized to 26.4psi @08:26:44.56 Pressure peaked at 26.4psi @08:26:44.57 delay 3 seconds @08:26:47.65 Cartridge at 23.4psi 3 seconds later @08:26:47.78 TV.seek :cartridge @08:26:49.58 TV.seek :free @08:26:51.38 TV.coast @08:26:51.44 Sampling 1000.0ml @08:26:51.45 Exhaust.open @08:26:52.29 Sea @-5.1psia @08:26:52.31 SP.setPosition! 0ml @08:26:52.37 SP.reconfigure SPsample @08:26:52.43 SP.seek 1000ml,1:23:53 @08:26:53.40 Cartridge 28 sampling 0/1000ml at 0.40ml/s with 18.9psi vacuum -8.7m deep (1.9psia) @08:27:53.41 Cartridge 28 sampling 25/1000ml at 0.42ml/s with 21.3psi vacuum -8.2m deep (2.5psia) @08:28:53.41 Cartridge 28 sampling 49/1000ml at 0.40ml/s with 23.5psi vacuum -9.1m deep (1.3psia) @08:29:53.41 Cartridge 28 sampling 73/1000ml at 0.38ml/s with 21.7psi vacuum -7.9m deep (3.1psia) @08:30:53.41 Cartridge 28 sampling 96/1000ml at 0.36ml/s with 22.3psi vacuum -9.4m deep (0.8psia) @08:31:53.41 Cartridge 28 sampling 119/1000ml at 0.38ml/s with 21.7psi vacuum -8.3m deep (2.4psia) @08:32:53.41 Cartridge 28 sampling 141/1000ml at 0.39ml/s with 21.6psi vacuum -9.3m deep (0.9psia) @08:33:53.41 Cartridge 28 sampling 164/1000ml at 0.36ml/s with 20.1psi vacuum -8.5m deep (2.2psia) @08:34:53.41 Cartridge 28 sampling 185/1000ml at 0.36ml/s with 21.7psi vacuum -9.2m deep (1.1psia) @08:35:53.41 Cartridge 28 sampling 207/1000ml at 0.35ml/s with 23.5psi vacuum -8.7m deep (1.8psia) @08:36:53.41 Cartridge 28 sampling 228/1000ml at 0.34ml/s with 18.0psi vacuum -9.2m deep (1.1psia) @08:37:53.41 Cartridge 28 sampling 248/1000ml at 0.34ml/s with 21.9psi vacuum -8.3m deep (2.5psia) @08:38:53.41 Cartridge 28 sampling 268/1000ml at 0.33ml/s with 22.6psi vacuum -9.2m deep (1.1psia) @08:39:53.41 Cartridge 28 sampling 288/1000ml at 0.33ml/s with 22.3psi vacuum -9.1m deep (1.2psia) @08:40:53.41 Cartridge 28 sampling 307/1000ml at 0.32ml/s with 17.3psi vacuum -8.3m deep (2.5psia) @08:41:53.41 Cartridge 28 sampling 326/1000ml at 0.31ml/s with 23.3psi vacuum -10.0m deep (-0.1psia) @08:42:53.41 Cartridge 28 sampling 345/1000ml at 0.31ml/s with 21.8psi vacuum -8.8m deep (1.7psia) @08:43:53.41 Cartridge 28 sampling 363/1000ml at 0.30ml/s with 21.2psi vacuum -9.2m deep (1.1psia) @08:44:53.41 Cartridge 28 sampling 381/1000ml at 0.29ml/s with 21.7psi vacuum -9.3m deep (1.0psia) @08:45:53.41 Cartridge 28 sampling 398/1000ml at 0.29ml/s with 18.2psi vacuum -9.0m deep (1.4psia) @08:46:53.41 Cartridge 28 sampling 415/1000ml at 0.27ml/s with 19.2psi vacuum -8.8m deep (1.6psia) @08:47:53.41 Cartridge 28 sampling 432/1000ml at 0.26ml/s with 21.9psi vacuum -9.3m deep (1.0psia) @08:48:53.41 Cartridge 28 sampling 448/1000ml at 0.29ml/s with 19.9psi vacuum -8.8m deep (1.7psia) @08:49:53.41 Cartridge 28 sampling 464/1000ml at 0.28ml/s with 22.9psi vacuum -10.0m deep (-0.1psia) @08:50:53.41 Cartridge 28 sampling 480/1000ml at 0.28ml/s with 23.5psi vacuum -8.4m deep (2.3psia) @08:51:53.41 Cartridge 28 sampling 495/1000ml at 0.27ml/s with 22.5psi vacuum -9.9m deep (0.1psia) @08:52:53.47 Cartridge 28 sampling 510/1000ml at 0.24ml/s with 20.7psi vacuum -9.0m deep (1.3psia) @08:53:53.41 Cartridge 28 sampling 525/1000ml at 0.25ml/s with 24.0psi vacuum -9.9m deep (-0.0psia) @08:54:53.41 Cartridge 28 sampling 539/1000ml at 0.23ml/s with 22.5psi vacuum -9.0m deep (1.4psia) @08:55:53.41 Cartridge 28 sampling 553/1000ml at 0.25ml/s with 22.6psi vacuum -9.5m deep (0.7psia) @08:56:53.41 Cartridge 28 sampling 567/1000ml at 0.21ml/s with 22.2psi vacuum -17.3m deep (-10.8psia) @08:57:53.41 Cartridge 28 sampling 580/1000ml at 0.20ml/s with 21.9psi vacuum -9.0m deep (1.4psia) @08:58:53.41 Cartridge 28 sampling 593/1000ml at 0.21ml/s with 21.9psi vacuum -10.1m deep (-0.2psia) @08:59:53.41 Cartridge 28 sampling 606/1000ml at 0.21ml/s with 23.5psi vacuum -8.9m deep (1.5psia) @09:00:53.41 Cartridge 28 sampling 619/1000ml at 0.21ml/s with 22.5psi vacuum -9.6m deep (0.5psia) @09:01:53.41 Cartridge 28 sampling 632/1000ml at 0.21ml/s with 24.8psi vacuum -9.7m deep (0.4psia) @09:02:53.41 Cartridge 28 sampling 644/1000ml at 0.21ml/s with 24.2psi vacuum -9.4m deep (0.9psia) @09:03:53.41 Cartridge 28 sampling 657/1000ml at 0.21ml/s with 26.2psi vacuum -9.2m deep (1.1psia) @09:04:11.59 Flow averaged 0.30ml/s over 37:12 @09:04:11.62 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @09:04:12.24 Relieved excess vacuum in 8.8 seconds @09:04:12.26 SP.seek 1000ml,28:48 @09:04:53.41 Cartridge 28 sampling 669/1000ml at 0.21ml/s with 23.7psi vacuum -9.8m deep (0.2psia) @09:05:14.55 Flow averaged 0.21ml/s over 1:02 @09:05:14.58 Waiting up to 11 seconds for vacuum to reduce from 26.2 to 18.0psi @09:05:15.26 Relieved excess vacuum in 1.8 seconds @09:05:15.28 SP.seek 1000ml,27:43 @09:05:19.85 Flow estimate reduced to 0.17ml/s @09:05:19.86 Intake.close @09:05:19.90 Exhaust.close @09:05:20.69 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @09:05:20.78 Sampled 674.7ml @09:05:20.79 TV.seek :bypass @09:05:22.41 TV.seek :free @09:05:24.07 TV.coast @09:05:25.16 -> Cmd.startProcessing @09:05:25.38 PV.seek :reagent @09:05:26.30 Sample loop closed. Ready to Deliver Reagents @09:05:26.31 ArS.seek :sealed @09:05:29.96 ArS.seek :evac @09:05:43.93 delay 20 seconds @09:06:03.96 ArS.seek :clear @09:06:21.10 RNAlater soak for 10:00 @09:06:21.11 delay 10:00 @09:16:21.14 ArS.seek :tVent @09:16:22.80 delay 1 second @09:16:23.82 ArS.seek :evac @09:16:39.78 delay 10 seconds @09:16:49.81 ArS.seek :tVent @09:17:05.77 delay 1 second @09:17:06.79 ArS.seek :evac @09:17:22.76 delay 10 seconds @09:17:32.79 Sample preserved and evacuated @09:17:33.65 -> Cmd.stop @09:17:34.02 ArS.seek :clear @09:17:51.28 PV.seek :clear @09:17:51.31 LyS2.seek :free @09:17:53.15 Gate.power :motor,:OFF @09:17:53.17 Gate.power :main,:OFF @09:17:53.19 Gate.power :core,:OFF @09:17:53.21 Safely stopped and ready to power off ##-- file closed 2018-01-29T17:42:18.329Z --## ##-- file opened 2018-01-29T17:42:18.330Z --## @09:38:18.45 -> showStatus @09:38:20.46 -> Cmd.loadCartridge @09:38:20.51 Powering core bus @09:38:23.19 ArS.configure ArSconfig @09:38:23.29 LyS1.configure LyS1config @09:38:23.41 LyS2.configure LyS2config @09:38:23.53 AirS.configure AirSconfig @09:38:23.64 TV.configure TVconfig @09:38:23.76 SP.configure SPconfig @09:38:23.87 Sea.configure SPconfig @09:38:24.01 SC.configure SCconfig @09:38:24.13 PV.configure PVconfig @09:38:24.18 All elf controllers running firmware version 4.41 @09:38:24.20 Gate.power :main,:ON,limit to 5000mA @09:38:24.22 Gate.power :motor,:ON,limit to 5000mA @09:38:24.30 Intake.close @09:38:24.33 Exhaust.close @09:38:24.35 PB.close @09:38:24.88 AirS.reconfigure AirSconfig @09:38:24.93 LyS2.reconfigure LyS2config @09:38:24.96 ArS.reconfigure ArSconfig @09:38:24.99 TV.reconfigure TVconfig @09:38:25.03 PV.reconfigure PVconfig @09:38:25.08 LyS1.reconfigure LyS1config @09:38:25.26 AirS.home.jog 0 @09:38:25.29 ArS.home.jog 0 @09:38:25.32 PV.home.jog 0 @09:38:25.34 LyS2.home.jog 0 @09:38:25.37 TV.home.jog 0 @09:38:25.39 LyS1.home.jog 0 @09:38:26.25 PV.reconfigure HomingPV @09:38:26.29 TV.reconfigure HomeTV @09:38:26.32 LyS2.reconfigure HomeSyringe @09:38:26.36 LyS1.reconfigure HomeSyringe @09:38:26.39 ArS.reconfigure HomeMagSyringe @09:38:26.43 AirS.reconfigure HomeMagSyringe @09:38:26.62 TV.jog -503 @09:38:26.66 PV.jog -115 @09:38:26.70 LyS2.jog -122 @09:38:26.72 LyS1.jog -113 @09:38:26.75 AirS.jog -126 @09:38:26.79 ArS.jog -130 @09:38:27.23 PV.setRawPosition! -50 @09:38:27.30 PV.seek :home @09:38:27.40 AirS.setRawPosition! -50 @09:38:27.42 LyS2.setRawPosition! -50 @09:38:27.44 ArS.setRawPosition! -50 @09:38:27.47 LyS1.setRawPosition! -50 @09:38:27.57 AirS.seek :home @09:38:27.61 LyS2.seek :home @09:38:27.68 LyS1.seek :home @09:38:27.72 ArS.seek :home @09:38:27.91 PV.reconfigure PVconfig @09:38:28.04 LyS2.reconfigure LyS2config @09:38:28.14 AirS.reconfigure AirSconfig @09:38:28.16 LyS1.reconfigure LyS1config @09:38:28.19 ArS.reconfigure ArSconfig @09:38:28.54 TV.setRawPosition! 0 @09:38:28.59 TV.seek :home @09:38:28.67 TV.reconfigure TVconfig @09:38:28.79 TV.seek :clear @09:38:30.40 SC.reconfigure HomeSC @09:38:30.46 SC.home.jog 0 @09:38:30.68 Selecting Cartridge slot 27 @09:38:31.21 SC.reconfigure SCconfig @09:38:31.27 SC.seek 27 @09:38:31.65 LyS2.seek :cartridge @09:38:31.68 PV.seek :cartridge @09:38:53.20 -> Cmd.startFiltering @09:38:53.40 Duration of filtering limited to 1:05:00 @09:38:53.59 Priming sample loop w/100ml, bypass w/10ml @09:38:53.61 TV.seek :bypass @09:38:55.22 TV.seek :free @09:38:56.88 TV.coast @09:38:56.92 PB.open @09:38:56.94 Exhaust.close @09:38:57.68 Intake.open @09:38:58.45 Sea @17.8psia @09:38:58.47 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @09:39:03.99 Vacuum tare is 23% of full scale @09:39:04.07 Sea @17.8psia @09:39:04.08 SP.setPosition! 0ml @09:39:04.14 SP.reconfigure SPprime @09:39:04.20 SP.seek 10ml,1:21 @09:39:14.77 PB.close @09:39:14.79 Exhaust.open @09:39:15.64 Sea @18.3psia @09:39:15.65 SP.setPosition! 0ml @09:39:15.71 SP.seek 100ml,8:51 @09:41:19.04 Pressurizing cartridge to 26psi @09:41:19.05 Intake.close @09:41:19.09 Exhaust.close @09:41:19.91 PB.open @09:41:20.59 delay 2 seconds @09:41:22.67 TV.seek :crack @09:41:23.46 TV.seek :free @09:41:24.26 TV.coast @09:41:24.30 Intake.open @09:41:25.03 delay 2 seconds @09:41:27.32 PB.close @09:41:28.08 Sea @17.7psia @09:41:28.10 SP.setPosition! 0ml @09:41:28.15 SP.reconfigure SPcharge @09:41:28.21 SP.seek 5ml,3:46 @09:41:38.81 Cartridge pressurized to 26.2psi @09:41:39.04 delay 3 seconds @09:41:42.11 Cartridge at 24.5psi 3 seconds later @09:41:42.24 TV.seek :cartridge @09:41:44.06 TV.seek :free @09:41:45.86 TV.coast @09:41:45.91 Sampling 1000.0ml @09:41:45.92 Exhaust.open @09:41:46.75 Sea @-6.7psia @09:41:46.77 SP.setPosition! 0ml @09:41:46.83 SP.reconfigure SPsample @09:41:46.89 SP.seek 1000ml,1:23:53 @09:41:47.87 Cartridge 27 sampling 0/1000ml at 0.41ml/s with 21.2psi vacuum -12.7m deep (-4.1psia) @09:42:47.87 Cartridge 27 sampling 24/1000ml at 0.40ml/s with 22.8psi vacuum -11.8m deep (-2.7psia) @09:43:47.87 Cartridge 27 sampling 46/1000ml at 0.38ml/s with 24.2psi vacuum -12.3m deep (-3.5psia) @09:44:47.87 Cartridge 27 sampling 69/1000ml at 0.38ml/s with 19.9psi vacuum -13.1m deep (-4.7psia) @09:45:47.87 Cartridge 27 sampling 91/1000ml at 0.38ml/s with 23.1psi vacuum -11.4m deep (-2.1psia) @09:46:47.87 Cartridge 27 sampling 113/1000ml at 0.36ml/s with 23.0psi vacuum -13.4m deep (-5.1psia) @09:47:47.87 Cartridge 27 sampling 134/1000ml at 0.37ml/s with 22.8psi vacuum -11.8m deep (-2.7psia) @09:48:47.86 Cartridge 27 sampling 155/1000ml at 0.33ml/s with 23.4psi vacuum -13.2m deep (-4.8psia) @09:49:47.87 Cartridge 27 sampling 176/1000ml at 0.33ml/s with 23.6psi vacuum -12.1m deep (-3.1psia) @09:50:47.87 Cartridge 27 sampling 196/1000ml at 0.32ml/s with 24.1psi vacuum -12.8m deep (-4.2psia) @09:51:47.87 Cartridge 27 sampling 216/1000ml at 0.34ml/s with 20.3psi vacuum -12.6m deep (-4.0psia) @09:52:47.87 Cartridge 27 sampling 235/1000ml at 0.32ml/s with 24.0psi vacuum -11.9m deep (-2.9psia) @09:53:47.87 Cartridge 27 sampling 254/1000ml at 0.31ml/s with 23.0psi vacuum -13.0m deep (-4.6psia) @09:54:47.87 Cartridge 27 sampling 273/1000ml at 0.31ml/s with 23.3psi vacuum -12.5m deep (-3.8psia) @09:55:47.87 Cartridge 27 sampling 292/1000ml at 0.33ml/s with 23.3psi vacuum -12.6m deep (-3.9psia) @09:56:47.87 Cartridge 27 sampling 310/1000ml at 0.29ml/s with 18.4psi vacuum -12.9m deep (-4.4psia) @09:57:47.87 Cartridge 27 sampling 328/1000ml at 0.27ml/s with 24.0psi vacuum -12.4m deep (-3.6psia) @09:58:47.86 Cartridge 27 sampling 345/1000ml at 0.28ml/s with 19.9psi vacuum -13.7m deep (-5.6psia) @09:59:47.87 Cartridge 27 sampling 362/1000ml at 0.31ml/s with 23.2psi vacuum -12.0m deep (-3.1psia) @10:00:47.87 Cartridge 27 sampling 379/1000ml at 0.25ml/s with 22.8psi vacuum -13.6m deep (-5.5psia) @10:01:47.87 Cartridge 27 sampling 395/1000ml at 0.26ml/s with 19.6psi vacuum -12.5m deep (-3.7psia) @10:02:47.87 Cartridge 27 sampling 412/1000ml at 0.29ml/s with 22.1psi vacuum -13.2m deep (-4.8psia) @10:03:47.87 Cartridge 27 sampling 427/1000ml at 0.24ml/s with 22.2psi vacuum -12.6m deep (-4.0psia) @10:04:47.87 Cartridge 27 sampling 443/1000ml at 0.26ml/s with 19.8psi vacuum -13.3m deep (-5.0psia) @10:05:47.87 Cartridge 27 sampling 458/1000ml at 0.27ml/s with 24.5psi vacuum -12.2m deep (-3.4psia) @10:06:47.87 Cartridge 27 sampling 473/1000ml at 0.23ml/s with 20.0psi vacuum -14.0m deep (-5.9psia) @10:07:47.87 Cartridge 27 sampling 488/1000ml at 0.24ml/s with 25.1psi vacuum -12.1m deep (-3.2psia) @10:08:47.86 Cartridge 27 sampling 502/1000ml at 0.25ml/s with 22.5psi vacuum -13.5m deep (-5.3psia) @10:09:47.87 Cartridge 27 sampling 516/1000ml at 0.24ml/s with 21.1psi vacuum -12.6m deep (-3.9psia) @10:10:47.87 Cartridge 27 sampling 530/1000ml at 0.24ml/s with 22.0psi vacuum -13.4m deep (-5.1psia) @10:11:47.87 Cartridge 27 sampling 543/1000ml at 0.21ml/s with 21.1psi vacuum -13.2m deep (-4.8psia) @10:12:47.87 Cartridge 27 sampling 557/1000ml at 0.23ml/s with 21.1psi vacuum -13.1m deep (-4.6psia) @10:13:47.87 Cartridge 27 sampling 570/1000ml at 0.20ml/s with 22.2psi vacuum -13.3m deep (-4.9psia) @10:14:47.87 Cartridge 27 sampling 583/1000ml at 0.21ml/s with 24.4psi vacuum -12.8m deep (-4.2psia) @10:15:47.87 Cartridge 27 sampling 595/1000ml at 0.21ml/s with 22.0psi vacuum -13.7m deep (-5.5psia) @10:16:47.87 Cartridge 27 sampling 608/1000ml at 0.20ml/s with 23.4psi vacuum -12.3m deep (-3.5psia) @10:17:47.87 Cartridge 27 sampling 621/1000ml at 0.21ml/s with 25.4psi vacuum -14.1m deep (-6.1psia) @10:18:47.86 Cartridge 27 sampling 633/1000ml at 0.21ml/s with 24.4psi vacuum -12.5m deep (-3.7psia) @10:18:55.78 Flow averaged 0.29ml/s over 37:02 @10:18:55.80 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @10:18:56.42 Relieved excess vacuum in 8.5 seconds @10:18:56.44 SP.seek 1000ml,30:57 @10:18:56.92 Flow estimate reduced to 0.23ml/s @10:18:56.94 Waiting up to 11 seconds for vacuum to reduce from 26.1 to 18.0psi @10:18:57.57 Relieved excess vacuum in 1.1 seconds @10:18:57.59 SP.seek 1000ml,30:56 @10:19:48.17 Cartridge 27 sampling 646/1000ml at 0.21ml/s with 26.2psi vacuum -13.4m deep (-5.1psia) @10:20:06.08 Flow averaged 0.24ml/s over 1:01 @10:20:06.10 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @10:20:06.72 Relieved excess vacuum in 8.5 seconds @10:20:06.74 SP.seek 1000ml,29:43 @10:20:07.21 Flow estimate reduced to 0.19ml/s @10:20:07.23 Intake.close @10:20:07.26 Exhaust.close @10:20:08.08 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @10:20:08.17 Sampled 649.7ml @10:20:08.19 TV.seek :bypass @10:20:09.79 TV.seek :free @10:20:11.45 TV.coast @10:20:12.64 -> Cmd.startProcessing @10:20:12.84 PV.seek :reagent @10:20:13.76 Sample loop closed. Ready to Deliver Reagents @10:20:13.78 ArS.seek :sealed @10:20:17.42 ArS.seek :evac @10:20:31.39 delay 20 seconds @10:20:51.42 ArS.seek :clear @10:21:08.54 RNAlater soak for 10:00 @10:21:08.56 delay 10:00 @10:31:08.59 ArS.seek :tVent @10:31:10.23 delay 1 second @10:31:11.26 ArS.seek :evac @10:31:27.20 delay 10 seconds @10:31:37.24 ArS.seek :tVent @10:31:53.18 delay 1 second @10:31:54.21 ArS.seek :evac @10:32:10.15 delay 10 seconds @10:32:20.18 Sample preserved and evacuated @10:32:21.13 -> Cmd.stop @10:32:21.50 ArS.seek :clear @10:32:38.74 PV.seek :clear @10:32:38.77 LyS2.seek :free @10:32:40.62 Gate.power :motor,:OFF @10:32:40.64 Gate.power :main,:OFF @10:32:40.66 Gate.power :core,:OFF @10:32:40.68 Safely stopped and ready to power off ##-- file closed 2018-01-29T18:48:38.381Z --## ##-- file opened 2018-01-29T18:48:38.383Z --## @10:44:32.37 -> showStatus @10:44:34.37 -> Cmd.loadCartridge @10:44:34.41 Powering core bus @10:44:37.10 ArS.configure ArSconfig @10:44:37.20 LyS1.configure LyS1config @10:44:37.32 LyS2.configure LyS2config @10:44:37.42 AirS.configure AirSconfig @10:44:37.54 TV.configure TVconfig @10:44:37.66 SP.configure SPconfig @10:44:37.78 Sea.configure SPconfig @10:44:37.92 SC.configure SCconfig @10:44:38.03 PV.configure PVconfig @10:44:38.09 All elf controllers running firmware version 4.41 @10:44:38.10 Gate.power :main,:ON,limit to 5000mA @10:44:38.12 Gate.power :motor,:ON,limit to 5000mA @10:44:38.20 Intake.close @10:44:38.24 Exhaust.close @10:44:38.27 PB.close @10:44:38.78 PV.reconfigure PVconfig @10:44:38.81 TV.reconfigure TVconfig @10:44:38.84 LyS2.reconfigure LyS2config @10:44:38.88 ArS.reconfigure ArSconfig @10:44:38.91 AirS.reconfigure AirSconfig @10:44:38.96 LyS1.reconfigure LyS1config @10:44:39.13 PV.home.jog 0 @10:44:39.16 TV.home.jog 0 @10:44:39.45 ArS.home.jog 0 @10:44:39.48 LyS2.home.jog 0 @10:44:39.50 LyS1.home.jog 0 @10:44:39.54 AirS.home.jog 0 @10:44:39.95 TV.reconfigure HomeTV @10:44:40.08 PV.reconfigure HomingPV @10:44:40.21 TV.jog -502 @10:44:40.25 PV.jog -118 @10:44:40.40 LyS2.reconfigure HomeSyringe @10:44:40.44 LyS1.reconfigure HomeSyringe @10:44:40.47 AirS.reconfigure HomeMagSyringe @10:44:40.51 ArS.reconfigure HomeMagSyringe @10:44:40.64 LyS1.jog -113 @10:44:40.70 LyS2.jog -125 @10:44:40.73 ArS.jog -128 @10:44:40.79 AirS.jog -128 @10:44:41.01 PV.setRawPosition! -50 @10:44:41.05 PV.seek :home @10:44:41.22 LyS1.setRawPosition! -50 @10:44:41.26 LyS1.seek :home @10:44:41.39 AirS.setRawPosition! -50 @10:44:41.41 ArS.setRawPosition! -50 @10:44:41.44 PV.reconfigure PVconfig @10:44:41.46 LyS2.setRawPosition! -50 @10:44:41.56 AirS.seek :home @10:44:41.64 LyS2.seek :home @10:44:41.70 ArS.seek :home @10:44:41.82 LyS1.reconfigure LyS1config @10:44:41.95 AirS.reconfigure AirSconfig @10:44:42.05 TV.setRawPosition! 0 @10:44:42.08 ArS.reconfigure ArSconfig @10:44:42.11 LyS2.reconfigure LyS2config @10:44:42.17 TV.seek :home @10:44:42.31 TV.reconfigure TVconfig @10:44:42.43 TV.seek :clear @10:44:44.04 SC.reconfigure HomeSC @10:44:44.11 SC.home.jog 0 @10:44:44.34 Selecting Cartridge slot 26 @10:44:44.89 SC.reconfigure SCconfig @10:44:44.95 SC.seek 26 @10:44:45.33 LyS2.seek :cartridge @10:44:45.36 PV.seek :cartridge @10:45:07.12 -> Cmd.startFiltering @10:45:07.31 Duration of filtering limited to 1:05:00 @10:45:07.50 Priming sample loop w/100ml, bypass w/10ml @10:45:07.51 TV.seek :bypass @10:45:09.13 TV.seek :free @10:45:10.79 TV.coast @10:45:10.83 PB.open @10:45:10.85 Exhaust.close @10:45:11.54 Intake.open @10:45:12.34 Sea @18.5psia @10:45:12.36 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @10:45:17.88 Vacuum tare is 23% of full scale @10:45:17.95 Sea @18.4psia @10:45:17.97 SP.setPosition! 0ml @10:45:18.02 SP.reconfigure SPprime @10:45:18.09 SP.seek 10ml,1:21 @10:45:28.66 PB.close @10:45:28.68 Exhaust.open @10:45:29.56 Sea @18.9psia @10:45:29.57 SP.setPosition! 0ml @10:45:29.63 SP.seek 100ml,8:51 @10:47:32.74 Pressurizing cartridge to 26psi @10:47:32.75 Intake.close @10:47:32.79 Exhaust.close @10:47:33.61 PB.open @10:47:34.30 delay 2 seconds @10:47:36.37 TV.seek :crack @10:47:37.16 TV.seek :free @10:47:38.23 TV.coast @10:47:38.28 Intake.open @10:47:39.01 delay 2 seconds @10:47:41.03 PB.close @10:47:41.81 Sea @19.6psia @10:47:41.82 SP.setPosition! 0ml @10:47:41.88 SP.reconfigure SPcharge @10:47:41.94 SP.seek 5ml,3:46 @10:47:48.56 Cartridge pressurized to 26.3psi @10:47:48.79 delay 3 seconds @10:47:51.86 Cartridge at 22.5psi 3 seconds later @10:47:51.99 TV.seek :cartridge @10:47:53.80 TV.seek :free @10:47:55.61 TV.coast @10:47:55.65 Sampling 1000.0ml @10:47:55.66 Exhaust.open @10:47:56.51 Sea @-1.9psia @10:47:56.53 SP.setPosition! 0ml @10:47:56.58 SP.reconfigure SPsample @10:47:56.65 SP.seek 1000ml,1:23:53 @10:47:57.63 Cartridge 26 sampling 0/1000ml at 0.40ml/s with 21.1psi vacuum -11.1m deep (-1.7psia) @10:48:57.63 Cartridge 26 sampling 25/1000ml at 0.42ml/s with 23.8psi vacuum -12.2m deep (-3.3psia) @10:49:57.63 Cartridge 26 sampling 48/1000ml at 0.39ml/s with 19.8psi vacuum -11.8m deep (-2.8psia) @10:50:57.63 Cartridge 26 sampling 72/1000ml at 0.39ml/s with 20.7psi vacuum -11.8m deep (-2.8psia) @10:51:57.63 Cartridge 26 sampling 95/1000ml at 0.37ml/s with 18.7psi vacuum -11.8m deep (-2.8psia) @10:52:57.63 Cartridge 26 sampling 118/1000ml at 0.38ml/s with 20.3psi vacuum -11.9m deep (-2.9psia) @10:53:57.63 Cartridge 26 sampling 140/1000ml at 0.37ml/s with 19.2psi vacuum -12.2m deep (-3.3psia) @10:54:57.63 Cartridge 26 sampling 162/1000ml at 0.35ml/s with 24.7psi vacuum -11.7m deep (-2.6psia) @10:55:57.63 Cartridge 26 sampling 183/1000ml at 0.36ml/s with 24.0psi vacuum -12.0m deep (-3.0psia) @10:56:57.63 Cartridge 26 sampling 205/1000ml at 0.35ml/s with 21.9psi vacuum -12.4m deep (-3.7psia) @10:57:57.63 Cartridge 26 sampling 225/1000ml at 0.35ml/s with 21.0psi vacuum -12.1m deep (-3.2psia) @10:58:57.63 Cartridge 26 sampling 246/1000ml at 0.33ml/s with 19.9psi vacuum -12.1m deep (-3.2psia) @10:59:57.63 Cartridge 26 sampling 266/1000ml at 0.34ml/s with 21.2psi vacuum -11.9m deep (-2.9psia) @11:00:57.63 Cartridge 26 sampling 285/1000ml at 0.33ml/s with 20.7psi vacuum -12.4m deep (-3.6psia) @11:01:57.63 Cartridge 26 sampling 305/1000ml at 0.33ml/s with 24.2psi vacuum -12.2m deep (-3.3psia) @11:02:57.63 Cartridge 26 sampling 323/1000ml at 0.32ml/s with 21.0psi vacuum -12.3m deep (-3.5psia) @11:03:57.63 Cartridge 26 sampling 342/1000ml at 0.29ml/s with 23.0psi vacuum -13.1m deep (-4.7psia) @11:04:57.63 Cartridge 26 sampling 360/1000ml at 0.30ml/s with 17.4psi vacuum -11.4m deep (-2.1psia) @11:05:57.63 Cartridge 26 sampling 378/1000ml at 0.28ml/s with 20.3psi vacuum -12.8m deep (-4.2psia) @11:06:57.63 Cartridge 26 sampling 395/1000ml at 0.26ml/s with 22.2psi vacuum -12.4m deep (-3.7psia) @11:07:57.63 Cartridge 26 sampling 412/1000ml at 0.30ml/s with 22.1psi vacuum -26.5m deep (-24.5psia) @11:08:57.63 Cartridge 26 sampling 429/1000ml at 0.28ml/s with 24.0psi vacuum -12.0m deep (-3.0psia) @11:09:57.63 Cartridge 26 sampling 445/1000ml at 0.26ml/s with 21.2psi vacuum -13.2m deep (-4.8psia) @11:10:57.63 Cartridge 26 sampling 461/1000ml at 0.25ml/s with 21.3psi vacuum -11.8m deep (-2.8psia) @11:11:57.63 Cartridge 26 sampling 476/1000ml at 0.26ml/s with 24.9psi vacuum -13.0m deep (-4.5psia) @11:12:57.63 Cartridge 26 sampling 492/1000ml at 0.27ml/s with 22.3psi vacuum -12.5m deep (-3.8psia) @11:13:57.63 Cartridge 26 sampling 507/1000ml at 0.22ml/s with 21.0psi vacuum -12.8m deep (-4.2psia) @11:14:57.63 Cartridge 26 sampling 521/1000ml at 0.25ml/s with 22.1psi vacuum -12.9m deep (-4.4psia) @11:15:57.63 Cartridge 26 sampling 536/1000ml at 0.24ml/s with 21.1psi vacuum -12.5m deep (-3.7psia) @11:16:57.63 Cartridge 26 sampling 550/1000ml at 0.21ml/s with 20.3psi vacuum -13.2m deep (-4.9psia) @11:17:57.63 Cartridge 26 sampling 563/1000ml at 0.21ml/s with 19.9psi vacuum -12.3m deep (-3.5psia) @11:18:57.63 Cartridge 26 sampling 577/1000ml at 0.23ml/s with 19.8psi vacuum -13.4m deep (-5.1psia) @11:19:57.63 Cartridge 26 sampling 590/1000ml at 0.22ml/s with 20.5psi vacuum -12.1m deep (-3.3psia) @11:20:57.63 Cartridge 26 sampling 603/1000ml at 0.20ml/s with 22.3psi vacuum -13.1m deep (-4.6psia) @11:21:57.63 Cartridge 26 sampling 616/1000ml at 0.22ml/s with 23.2psi vacuum -12.7m deep (-4.0psia) @11:22:57.63 Cartridge 26 sampling 629/1000ml at 0.22ml/s with 23.0psi vacuum -12.7m deep (-4.1psia) @11:23:57.63 Cartridge 26 sampling 641/1000ml at 0.21ml/s with 23.1psi vacuum -12.5m deep (-3.8psia) @11:24:57.63 Cartridge 26 sampling 654/1000ml at 0.21ml/s with 25.0psi vacuum -12.3m deep (-3.5psia) @11:25:57.63 Cartridge 26 sampling 666/1000ml at 0.21ml/s with 24.7psi vacuum -12.6m deep (-4.0psia) @11:26:52.86 Flow averaged 0.29ml/s over 38:52 @11:26:52.89 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @11:26:53.51 Relieved excess vacuum in 5.8 seconds @11:26:53.53 SP.seek 1000ml,27:21 @11:26:57.68 Cartridge 26 sampling 679/1000ml at 0.21ml/s with 22.8psi vacuum -13.2m deep (-4.7psia) @11:27:56.11 Flow averaged 0.24ml/s over 55 seconds @11:27:56.14 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @11:27:56.76 Relieved excess vacuum in 9 seconds @11:27:56.78 SP.seek 1000ml,26:16 @11:27:57.63 Cartridge 26 sampling 691/1000ml at 0.21ml/s with 25.3psi vacuum -12.4m deep (-3.6psia) @11:28:13.48 Flow averaged 0.27ml/s over 14 seconds @11:28:13.51 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @11:28:14.13 Relieved excess vacuum in 4.3 seconds @11:28:14.15 SP.seek 1000ml,25:58 @11:28:52.08 Flow averaged 0.24ml/s over 34 seconds @11:28:52.11 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @11:28:52.73 Relieved excess vacuum in 5.5 seconds @11:28:52.75 SP.seek 1000ml,25:18 @11:28:57.64 Cartridge 26 sampling 704/1000ml at 0.20ml/s with 22.9psi vacuum -13.5m deep (-5.2psia) @11:29:18.63 Flow averaged 0.22ml/s over 25 seconds @11:29:18.66 Waiting up to 12 seconds for vacuum to reduce from 26.6 to 18.0psi @11:29:19.28 Relieved excess vacuum in 1.6 seconds @11:29:19.30 SP.seek 1000ml,24:51 @11:29:20.77 Flow estimate reduced to 0.17ml/s @11:29:20.78 Intake.close @11:29:20.82 Exhaust.close @11:29:21.62 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @11:29:21.71 Sampled 708.3ml @11:29:21.72 TV.seek :bypass @11:29:23.33 TV.seek :free @11:29:24.99 TV.coast @11:29:25.88 -> Cmd.startProcessing @11:29:26.08 PV.seek :reagent @11:29:26.99 Sample loop closed. Ready to Deliver Reagents @11:29:27.00 ArS.seek :sealed @11:29:30.64 ArS.seek :evac @11:29:44.60 delay 20 seconds @11:30:04.64 ArS.seek :clear @11:30:21.76 RNAlater soak for 10:00 @11:30:21.78 delay 10:00 @11:40:21.81 ArS.seek :tVent @11:40:23.45 delay 1 second @11:40:24.48 ArS.seek :evac @11:40:40.42 delay 10 seconds @11:40:50.46 ArS.seek :tVent @11:41:06.40 delay 1 second @11:41:07.43 ArS.seek :evac @11:41:23.38 delay 10 seconds @11:41:33.41 Sample preserved and evacuated @11:41:34.38 -> Cmd.stop @11:41:34.74 ArS.seek :clear @11:41:52.01 PV.seek :clear @11:41:52.04 LyS2.seek :free @11:41:53.87 Gate.power :motor,:OFF @11:41:53.89 Gate.power :main,:OFF @11:41:53.91 Gate.power :core,:OFF @11:41:53.93 Safely stopped and ready to power off ##-- file closed 2018-01-29T19:57:06.410Z --## ##-- file opened 2018-01-29T19:57:06.413Z --## @11:52:54.06 -> showStatus @11:52:56.06 -> Cmd.loadCartridge @11:52:56.11 Powering core bus @11:52:58.80 ArS.configure ArSconfig @11:52:58.90 LyS1.configure LyS1config @11:52:59.02 LyS2.configure LyS2config @11:52:59.12 AirS.configure AirSconfig @11:52:59.24 TV.configure TVconfig @11:52:59.35 SP.configure SPconfig @11:52:59.47 Sea.configure SPconfig @11:52:59.61 SC.configure SCconfig @11:52:59.72 PV.configure PVconfig @11:52:59.78 All elf controllers running firmware version 4.41 @11:52:59.80 Gate.power :main,:ON,limit to 5000mA @11:52:59.82 Gate.power :motor,:ON,limit to 5000mA @11:52:59.91 Intake.close @11:52:59.94 Exhaust.close @11:52:59.98 PB.close @11:53:00.46 TV.reconfigure TVconfig @11:53:00.51 AirS.reconfigure AirSconfig @11:53:00.54 LyS2.reconfigure LyS2config @11:53:00.58 ArS.reconfigure ArSconfig @11:53:00.66 PV.reconfigure PVconfig @11:53:00.68 LyS1.reconfigure LyS1config @11:53:00.84 AirS.home.jog 0 @11:53:01.12 TV.home.jog 0 @11:53:01.15 LyS2.home.jog 0 @11:53:01.19 PV.home.jog 0 @11:53:01.21 LyS1.home.jog 0 @11:53:01.23 ArS.home.jog 0 @11:53:01.69 TV.reconfigure HomeTV @11:53:01.75 AirS.reconfigure HomeMagSyringe @11:53:01.79 LyS2.reconfigure HomeSyringe @11:53:01.85 PV.reconfigure HomingPV @11:53:02.02 TV.jog -498 @11:53:02.05 LyS2.jog -125 @11:53:02.09 AirS.jog -127 @11:53:02.12 PV.jog -114 @11:53:02.30 ArS.reconfigure HomeMagSyringe @11:53:02.32 LyS1.reconfigure HomeSyringe @11:53:02.40 ArS.jog -131 @11:53:02.43 LyS1.jog -111 @11:53:02.57 LyS2.setRawPosition! -50 @11:53:02.61 LyS2.seek :home @11:53:02.69 PV.setRawPosition! -50 @11:53:02.70 AirS.setRawPosition! -50 @11:53:02.81 PV.seek :home @11:53:02.90 AirS.seek :home @11:53:03.02 LyS2.reconfigure LyS2config @11:53:03.04 LyS1.setRawPosition! -50 @11:53:03.07 ArS.setRawPosition! -50 @11:53:03.16 LyS1.seek :home @11:53:03.26 ArS.seek :home @11:53:03.34 PV.reconfigure PVconfig @11:53:03.36 AirS.reconfigure AirSconfig @11:53:03.48 LyS1.reconfigure LyS1config @11:53:03.56 ArS.reconfigure ArSconfig @11:53:03.84 TV.setRawPosition! 0 @11:53:03.89 TV.seek :home @11:53:03.98 TV.reconfigure TVconfig @11:53:04.09 TV.seek :clear @11:53:05.71 SC.reconfigure HomeSC @11:53:05.77 SC.home.jog 0 @11:53:05.99 Selecting Cartridge slot 25 @11:53:06.54 SC.reconfigure SCconfig @11:53:06.59 SC.seek 25 @11:53:06.97 LyS2.seek :cartridge @11:53:07.01 PV.seek :cartridge @11:53:28.81 -> Cmd.startFiltering @11:53:29.01 Duration of filtering limited to 1:05:00 @11:53:29.21 Priming sample loop w/100ml, bypass w/10ml @11:53:29.23 TV.seek :bypass @11:53:30.84 TV.seek :free @11:53:32.50 TV.coast @11:53:32.54 PB.open @11:53:32.56 Exhaust.close @11:53:33.29 Intake.open @11:53:34.11 Sea @19.1psia @11:53:34.12 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @11:53:39.65 Vacuum tare is 23% of full scale @11:53:39.72 Sea @19.1psia @11:53:39.74 SP.setPosition! 0ml @11:53:39.79 SP.reconfigure SPprime @11:53:39.85 SP.seek 10ml,1:21 @11:53:50.43 PB.close @11:53:50.45 Exhaust.open @11:53:51.29 Sea @18.7psia @11:53:51.31 SP.setPosition! 0ml @11:53:51.37 SP.seek 100ml,8:51 @11:55:54.59 Pressurizing cartridge to 26psi @11:55:54.60 Intake.close @11:55:54.63 Exhaust.close @11:55:55.44 PB.open @11:55:56.12 delay 2 seconds @11:55:58.20 TV.seek :crack @11:55:58.99 TV.seek :free @11:55:59.80 TV.coast @11:55:59.84 Intake.open @11:56:00.87 delay 2 seconds @11:56:02.90 PB.close @11:56:03.65 Sea @18.6psia @11:56:03.66 SP.setPosition! 0ml @11:56:03.71 SP.reconfigure SPcharge @11:56:03.78 SP.seek 5ml,3:46 @11:56:10.33 Cartridge pressurized to 26.2psi @11:56:10.56 delay 3 seconds @11:56:13.63 Cartridge at 23.8psi 3 seconds later @11:56:13.76 TV.seek :cartridge @11:56:15.58 TV.seek :free @11:56:17.38 TV.coast @11:56:17.43 Sampling 1000.0ml @11:56:17.45 Exhaust.open @11:56:18.28 Sea @-10.0psia @11:56:18.30 SP.setPosition! 0ml @11:56:18.35 SP.reconfigure SPsample @11:56:18.42 SP.seek 1000ml,1:23:53 @11:56:19.39 Cartridge 25 sampling 0/1000ml at 0.39ml/s with 20.3psi vacuum -12.5m deep (-3.8psia) @11:57:19.40 Cartridge 25 sampling 24/1000ml at 0.37ml/s with 23.6psi vacuum -11.5m deep (-2.3psia) @11:58:19.40 Cartridge 25 sampling 46/1000ml at 0.38ml/s with 20.8psi vacuum -12.4m deep (-3.6psia) @11:59:19.40 Cartridge 25 sampling 69/1000ml at 0.38ml/s with 24.3psi vacuum -11.4m deep (-2.1psia) @12:00:19.40 Cartridge 25 sampling 91/1000ml at 0.36ml/s with 24.4psi vacuum -12.6m deep (-4.0psia) @12:01:19.40 Cartridge 25 sampling 113/1000ml at 0.37ml/s with 24.5psi vacuum -11.6m deep (-2.5psia) @12:02:19.40 Cartridge 25 sampling 135/1000ml at 0.36ml/s with 23.2psi vacuum -12.1m deep (-3.2psia) @12:03:19.40 Cartridge 25 sampling 156/1000ml at 0.36ml/s with 19.9psi vacuum -12.9m deep (-4.3psia) @12:04:19.40 Cartridge 25 sampling 177/1000ml at 0.33ml/s with 22.5psi vacuum -11.7m deep (-2.6psia) @12:05:19.40 Cartridge 25 sampling 197/1000ml at 0.34ml/s with 25.4psi vacuum -12.5m deep (-3.8psia) @12:06:19.40 Cartridge 25 sampling 217/1000ml at 0.33ml/s with 18.2psi vacuum -12.8m deep (-4.3psia) @12:07:19.40 Cartridge 25 sampling 237/1000ml at 0.33ml/s with 23.3psi vacuum -11.1m deep (-1.7psia) @12:08:19.40 Cartridge 25 sampling 257/1000ml at 0.33ml/s with 21.4psi vacuum -13.3m deep (-4.9psia) @12:09:19.40 Cartridge 25 sampling 276/1000ml at 0.30ml/s with 21.3psi vacuum -11.7m deep (-2.6psia) @12:10:19.40 Cartridge 25 sampling 295/1000ml at 0.31ml/s with 23.7psi vacuum -13.0m deep (-4.5psia) @12:11:19.40 Cartridge 25 sampling 314/1000ml at 0.33ml/s with 24.0psi vacuum -11.6m deep (-2.5psia) @12:12:19.40 Cartridge 25 sampling 332/1000ml at 0.31ml/s with 21.1psi vacuum -13.2m deep (-4.8psia) @12:13:19.40 Cartridge 25 sampling 350/1000ml at 0.29ml/s with 20.0psi vacuum -11.9m deep (-2.9psia) @12:14:19.40 Cartridge 25 sampling 368/1000ml at 0.26ml/s with 21.7psi vacuum -12.9m deep (-4.4psia) @12:15:19.40 Cartridge 25 sampling 385/1000ml at 0.28ml/s with 21.3psi vacuum -12.1m deep (-3.2psia) @12:16:19.40 Cartridge 25 sampling 402/1000ml at 0.27ml/s with 25.9psi vacuum -12.3m deep (-3.5psia) @12:17:19.40 Cartridge 25 sampling 419/1000ml at 0.30ml/s with 23.4psi vacuum -12.4m deep (-3.6psia) @12:18:19.40 Cartridge 25 sampling 435/1000ml at 0.29ml/s with 22.6psi vacuum -13.0m deep (-4.5psia) @12:19:19.40 Cartridge 25 sampling 451/1000ml at 0.27ml/s with 18.6psi vacuum -12.6m deep (-4.0psia) @12:20:19.40 Cartridge 25 sampling 467/1000ml at 0.25ml/s with 19.9psi vacuum -12.3m deep (-3.5psia) @12:21:19.40 Cartridge 25 sampling 483/1000ml at 0.24ml/s with 20.8psi vacuum -13.4m deep (-5.0psia) @12:22:19.40 Cartridge 25 sampling 498/1000ml at 0.25ml/s with 22.0psi vacuum -12.0m deep (-3.0psia) @12:23:19.40 Cartridge 25 sampling 513/1000ml at 0.24ml/s with 21.4psi vacuum -13.6m deep (-5.4psia) @12:24:19.40 Cartridge 25 sampling 527/1000ml at 0.25ml/s with 20.9psi vacuum -12.2m deep (-3.3psia) @12:25:19.40 Cartridge 25 sampling 541/1000ml at 0.25ml/s with 22.9psi vacuum -13.3m deep (-5.0psia) @12:26:19.40 Cartridge 25 sampling 555/1000ml at 0.22ml/s with 21.3psi vacuum -12.4m deep (-3.6psia) @12:27:19.40 Cartridge 25 sampling 569/1000ml at 0.21ml/s with 21.1psi vacuum -13.2m deep (-4.8psia) @12:28:19.40 Cartridge 25 sampling 582/1000ml at 0.22ml/s with 21.5psi vacuum -12.3m deep (-3.5psia) @12:29:19.40 Cartridge 25 sampling 596/1000ml at 0.21ml/s with 20.9psi vacuum -12.7m deep (-4.0psia) @12:30:19.40 Cartridge 25 sampling 609/1000ml at 0.23ml/s with 23.1psi vacuum -13.0m deep (-4.5psia) @12:31:19.40 Cartridge 25 sampling 622/1000ml at 0.21ml/s with 23.5psi vacuum -27.8m deep (-26.3psia) @12:32:19.40 Cartridge 25 sampling 634/1000ml at 0.20ml/s with 23.1psi vacuum -12.5m deep (-3.8psia) @12:33:19.40 Cartridge 25 sampling 647/1000ml at 0.21ml/s with 25.6psi vacuum -12.9m deep (-4.3psia) @12:34:19.40 Cartridge 25 sampling 659/1000ml at 0.21ml/s with 24.0psi vacuum -13.3m deep (-5.0psia) @12:35:19.40 Cartridge 25 sampling 672/1000ml at 0.21ml/s with 26.1psi vacuum -12.3m deep (-3.4psia) @12:36:08.19 Flow averaged 0.29ml/s over 39:42 @12:36:08.21 Waiting up to 12 seconds for vacuum to reduce from 26.5 to 18.0psi @12:36:08.83 Relieved excess vacuum in 9.3 seconds @12:36:08.86 SP.seek 1000ml,27:00 @12:36:19.40 Cartridge 25 sampling 684/1000ml at 0.20ml/s with 23.4psi vacuum -13.6m deep (-5.4psia) @12:36:48.31 Flow averaged 0.27ml/s over 31 seconds @12:36:48.34 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @12:36:48.95 Relieved excess vacuum in 9.5 seconds @12:36:48.98 SP.seek 1000ml,26:18 @12:37:19.40 Cartridge 25 sampling 697/1000ml at 0.21ml/s with 26.6psi vacuum -12.3m deep (-3.6psia) @12:37:27.13 Flow averaged 0.26ml/s over 31 seconds @12:37:27.16 Waiting up to 11 seconds for vacuum to reduce from 26.3 to 18.0psi @12:37:27.77 Relieved excess vacuum in 8.4 seconds @12:37:27.80 SP.seek 1000ml,25:38 @12:37:59.90 Flow averaged 0.29ml/s over 24 seconds @12:37:59.93 Waiting up to 12 seconds for vacuum to reduce from 26.4 to 18.0psi @12:38:00.54 Relieved excess vacuum in 9.7 seconds @12:38:00.57 SP.seek 1000ml,25:05 @12:38:11.29 Flow estimate reduced to 0.23ml/s @12:38:11.31 Waiting up to 11 seconds for vacuum to reduce from 26.4 to 18.0psi @12:38:11.92 Relieved excess vacuum in 8.3 seconds @12:38:11.95 SP.seek 1000ml,24:54 @12:38:18.00 Flow estimate reduced to 0.19ml/s @12:38:18.01 Intake.close @12:38:18.05 Exhaust.close @12:38:18.83 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @12:38:18.92 Sampled 708.8ml @12:38:18.94 TV.seek :bypass @12:38:20.54 TV.seek :free @12:38:22.20 TV.coast @12:38:23.12 -> Cmd.startProcessing @12:38:23.37 PV.seek :reagent @12:38:24.28 Sample loop closed. Ready to Deliver Reagents @12:38:24.29 ArS.seek :sealed @12:38:27.93 ArS.seek :evac @12:38:41.88 delay 20 seconds @12:39:01.92 ArS.seek :clear @12:39:19.04 RNAlater soak for 10:00 @12:39:19.05 delay 10:00 @12:49:19.08 ArS.seek :tVent @12:49:20.72 delay 1 second @12:49:21.75 ArS.seek :evac @12:49:37.69 delay 10 seconds @12:49:47.73 ArS.seek :tVent @12:50:03.67 delay 1 second @12:50:04.70 ArS.seek :evac @12:50:20.64 delay 10 seconds @12:50:30.68 Sample preserved and evacuated @12:50:31.63 -> Cmd.stop @12:50:31.99 ArS.seek :clear @12:50:49.24 PV.seek :clear @12:50:49.27 LyS2.seek :free @12:50:51.10 Gate.power :motor,:OFF @12:50:51.13 Gate.power :main,:OFF @12:50:51.15 Gate.power :core,:OFF @12:50:51.17 Safely stopped and ready to power off ##-- file closed 2018-01-29T22:46:08.257Z --##