##-- file opened 2017-02-07T21:00:11.206Z --## @12:57:47.06 -> showStatus @12:57:48.66 -> Cmd.loadCartridge @12:57:49.53 ArS.reconfigure ArSconfig @12:57:49.63 LyS1.reconfigure LyS1config @12:57:49.83 LyS2.reconfigure LyS2config @12:57:49.94 AirS.reconfigure AirSconfig @12:57:50.08 ArS.home.jog 0 @12:57:50.12 LyS1.home.jog 0 @12:57:50.18 LyS2.home.jog 0 @12:57:50.23 PV.reconfigure PVconfig @12:57:50.31 AirS.home.jog 0 @12:57:50.41 TV.setRawPosition! -10 @12:57:50.43 PV.home.jog 0 @12:57:50.56 TV.seek :home @12:57:51.24 PV.setRawPosition! -50 @12:57:51.29 PV.reconfigure HomingPV @12:57:51.35 PV.seek :home @12:57:51.49 ArS.setRawPosition! -50 @12:57:51.52 ArS.reconfigure HomeMagSyringe @12:57:51.60 ArS.seek :home @12:57:51.82 LyS1.setRawPosition! -50 @12:57:51.86 LyS1.reconfigure HomeSyringe @12:57:51.91 LyS1.seek :home @12:57:52.11 LyS2.setRawPosition! -50 @12:57:52.16 LyS2.reconfigure HomeSyringe @12:57:52.22 LyS2.seek :home @12:57:52.33 PV.reconfigure PVconfig @12:57:52.44 ArS.reconfigure ArSconfig @12:57:52.53 AirS.setRawPosition! -50 @12:57:52.57 AirS.reconfigure HomeMagSyringe @12:57:52.65 AirS.seek :home @12:57:52.76 LyS1.reconfigure LyS1config @12:57:52.87 LyS2.reconfigure LyS2config @12:57:53.03 AirS.reconfigure AirSconfig @12:57:53.16 TV.seek :clear @12:57:54.61 SC.setRawPosition! -83 @12:57:54.66 SC.seek :home @12:57:55.17 Selecting Cartridge slot 2 @12:57:55.56 SC.seek 2 @12:57:56.19 LyS2.seek :cartridge @12:57:56.23 PV.seek :cartridge @12:58:07.89 -> Cmd.startFiltering @12:58:08.23 Duration of filtering limited to 15:00 @12:58:08.42 Priming bypass loop with 30ml @12:58:08.44 TV.seek :bypass @12:58:09.91 TV.seek :free @12:58:11.36 TV.coast @12:58:11.39 Exhaust.open @12:58:12.85 Intake.open @12:58:14.42 Waiting 4 - 300s for filter pressure to stabilize +/-0.5psi @12:58:20.16 SP.setPosition! 0.00ml @12:58:20.27 SP.reconfigure SPprime @12:58:20.33 SP.seek 30.00ml,3:00 @12:58:45.31 Pressurizing cartridge to 23psi @12:58:45.32 PB.open @12:58:46.78 delay 2 seconds @12:58:48.81 Exhaust.close @12:58:50.33 Intake.close @12:58:51.83 TV.seek :cartridge @12:58:53.42 TV.seek :free @12:58:55.00 TV.coast @12:58:55.02 Intake.open @12:58:56.49 delay 2 seconds @12:58:58.52 PB.close @12:59:00.03 SP.setPosition! 0.00ml @12:59:00.12 SP.reconfigure SPcharge @12:59:00.20 SP.seek 10.00ml,1:20 @12:59:10.72 Sampling 1000.0ml @12:59:10.74 Exhaust.open @12:59:12.20 SP.setPosition! 0.00ml @12:59:12.30 SP.reconfigure SPsample @12:59:12.37 SP.seek 1000.00ml,1:23:50 @13:13:08.28 SP.coast @13:13:08.33 Intake.close @13:13:08.40 Exhaust.close @13:13:09.93 TV.seek :bypass @13:13:11.39 TV.seek :free @13:13:12.86 TV.coast @13:13:12.91 Cmd::Paused in FILTERING -- CartridgeTimelimit Expired during Sample Pump move after sampling 167.3ml @13:13:14.50 -> Cmd.startProcessing @13:13:14.84 PV.reconfigure PVreagentconfig @13:13:14.88 PV.seek :reagent @13:13:15.84 Sample loop closed. Ready to Deliver Reagents @13:13:15.87 ArS.seek :sealed @13:13:19.61 ArS.seek :evac @13:13:33.75 delay 20 seconds @13:13:53.80 ArS.seek :clear @13:14:11.15 RNAlater soak for 10:00 @13:14:11.19 delay 10:00 @13:24:11.26 ArS.seek :tVent @13:24:13.42 delay 1 second @13:24:14.45 ArS.seek :evac @13:24:30.21 delay 10 seconds @13:24:40.24 ArS.seek :tVent @13:24:56.00 delay 1 second @13:24:57.02 ArS.seek :evac @13:25:12.83 delay 10 seconds @13:25:22.90 Sample preserved and evacuated @13:25:24.03 -> Cmd.stop @13:25:24.46 ArS.seek :clear @13:25:41.96 PV.reconfigure PVconfig @13:25:42.01 LyS2.seek :free @13:25:42.06 PV.seek :clear ##-- file closed 2017-02-07T22:00:55.480Z --##