2017-09-24T06:41:21.640Z,1506235281.640 [Supervisor](FAULT): Ignoring configuration overrides from Data/persisted.cfg 2017-09-24T06:41:27.739Z,1506235287.739 [SBIT](IMPORTANT): git: 2017-04-25-53-gcaea116 2017-09-24T06:41:27.744Z,1506235287.744 [CBIT](FAULT): LAST RESTART WAS UNINTENTIONAL. 2017-09-24T06:41:30.584Z,1506235290.584 [DropWeight](CRITICAL): DROP WEIGHT MISSING. 2017-09-24T06:41:31.103Z,1506235291.103 [BuoyancyServo](FAULT): Buoyancy failed to initialize 2017-09-24T06:41:31.317Z,1506235291.317 [CommandLine](FAULT): Scheduling is paused 2017-09-24T06:41:31.321Z,1506235291.321 [CBIT](CRITICAL): Hardware Fault in component: DropWeight 2017-09-24T06:42:39.410Z,1506235359.410 [SBIT](IMPORTANT): Beginning Startup BIT 2017-09-24T06:42:39.415Z,1506235359.415 [CBIT](IMPORTANT): Beginning ground fault scan 2017-09-24T06:42:50.081Z,1506235370.081 [CBIT](IMPORTANT): Ground fault detected mA: CHAN A0 (Batt): -0.009317 CHAN A1 (24V): 0.122136 CHAN A2 (12V): 0.000655 CHAN A3 (5V): -0.000144 CHAN B0 (3.3V): 0.000384 CHAN B1 (3.15aV): 0.000296 CHAN B2 (3.15bV): 0.000339 CHAN B3 (GND): -0.000412 OPEN: 0.004747 Full Scale Calc: 4.765 mA, -1.589 mA 2017-09-24T06:43:28.760Z,1506235408.760 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T06:43:33.056Z,1506235413.056 [SBIT](IMPORTANT): SBIT PASSED 2017-09-24T06:43:33.352Z,1506235413.352 [MissionManager](IMPORTANT): Started mission Startup 2017-09-24T06:45:31.027Z,1506235531.027 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T06:45:34.060Z,1506235534.060 [MissionManager](IMPORTANT): Started mission Default 2017-09-24T06:47:34.100Z,1506235654.100 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time. 2017-09-24T06:47:35.435Z,1506235655.435 [Rowe_600LCM](FAULT): LCB fault: Software Overcurrent. 2017-09-24T06:50:35.215Z,1506235835.215 [Rowe_600LCM](FAULT): Did not receive valid device response within the specified allowable sample time.