1 ATLAS TEMPERATURE CALIBRATIONS ------------------------ Date: 5-Feb-98 Counts/Resist/Temp Conv: Observers:___________ R = Calibration Program: calsh5 T = Temperature Range:__________________ ------------------------------------------------------- Comments regarding calibration: (procedure changes,new standard, software changes, etc) ------------------------------------------------------ A B C Max Std Sensor *E-02 *E-03 *E-05 Resid Error Comments S 4703 .2325171 .0422258 1.3859388 .0075 .0068 S 4704 .2305042 .0500392 1.3825719 .0074 .0065 S 4705 .2297237 .0498275 1.3692506 .0072 .0064 S 4706 .2304239 .0503879 1.3699156 .0074 .0064 S 4707 .2305167 .0507664 1.3749072 .0074 .0064 S 4708 .2310483 .0475715 1.3713599 .0073 .0065 S 4709 .2301181 .0534687 1.3752219 .0072 .0064 S 4710 .2304185 .0535371 1.3795786 .0072 .0062 S 4711 .2314208 .0483504 1.3904055 .0077 .0067 S 4712 .2324919 .0442161 1.3946342 .0078 .0068 ------------------------------------------------------ Self-Calibrating Board Summary: Sensor 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 4703 ****************************************************** 4704 ****************************************************** 4705 ****************************************************** 4706 -45.37************************************************ 4707 -45.40************************************************ 4708 ****************************************************** 4709 ****************************************************** 4710 ****************************** -6.84 13.85 20.00 21.99 4711 ****************************************************** 4712 ******************************************************