# Calibration file for Ground Fault Board for OASIS3 Mooring # O3 GndFault Board #3 # File created 3/2008 (rschramm) # from calibration file GF_CAL.XLS with data dated 6/5/2001 # # There is one line for each value to put in the data file, as follows: # raw_offset cal_offset cal_divisor units ident # # The raw data is converted to calibrated data as follows: # output = (raw - cal_offset)/cal_divisor # and the raw data begins at "raw_offset" bytes in the raw data stream # 0 480.64 0.8985 uA Power + leakage 2 494.25 0.8850 uA Power common leakage