OASIS/NOAA Equatorial Pacific Energy use Acquire Sample Consump. Consump Sensor Number Current Time Interval Hrs /day /year Deployed (ma) (sec) (min) /day mAh@12V Ah@12V ------ -------- ------- ------- ------- ---- ------- ------- Battery Pack 1 - 10-15VDC OASIS 1 25 25% duty 24 120 43.8 NO3 2 internal WetStar 2 45 10 15 24 24 8.8 PRR 2 250 10 15 12 66.7 24.3 MCP-200 2 45 10 15 12 12 4.4 Satlantic 2 4 10 15 12 1 0.4 Lens covers 3 150 10 15 24 120 43.8 AC-9 1 800 25 15 24 533 194.7 pCO2 1 1000 200 180 24 444 162.2 pCO2 pump 1 40 60 15 24 64 23.4 March pump * 1 500@8V 30 15 24 314 114.5 ------- 620.3 Battery Pack 2 - 7-11 VDC Argos PTT 1 750 ma send @ 1/55 duty, 8 hrs/day 31.9 + 150 ua quiescent, 24 hrs/day Battery packs: Pack 1: 52 strings of 10 D cells @ 12 Ah/cell = 624 Ah @ 9 to 15 VDC Pack 2: 4 strings of 7 D cells @ 10 Ah/cell = 40 Ah @ 7 to 10.5 VDC * Note - March pump operates at 8VDC, we generate via DC-DC converter, assume 85% efficiency