# Calibration file for PRR-600 Spectroradiometers Serial number 19606 with MCP's 7185[10m] and 7186[30m]. # This is the configuration used on ep1 at 19970513 # NOTE: The Lu412 and LU443 diodes were swapped inside of the instrument for this calibration # # Model PRR-600 # File created 01 Jun 1999 by Brian Schlining # # Format of this file was chosen to be consistent with Biospherical cal file # # First line has one entry for each address tag, specifying number of # channels for that address tag # # There follows one line of calibration data for each channel as follows: # bank chan type name a b c cmin cmax units # # bank: Bank number, i.e., the address tag for a given bank of channels # chan: Channel number # type: Type of channel, as follows: 0 = unused, 1 = down irrad, 2 = analog, # 3 = up radiance, 4 = up irrad, 5 = quadratic, 6 = Old Satlantic cals # 7 = New Satlantic cals (b is multiplier) or MCP # Once a count is converted to a voltage, via fixed algorithm, # the voltage is converted to given units as follows: # Type 0: not converted or reported # Types 1 - 4: value = (volts - c) / b (a is unused) # Type 5: value = a + (b * volts) + (c * volts^2) # Type 6: value = a * (volts - c) / b # Type 7: value = a * b * (volts - c) # name: Name of channel # a: Calibration "a" value, unused for types 1-4 # b: Calibration "b" value # c: Calibration "c" value, unused for type 6 # cmin: unused # cmax: unused # units: Units that value decodes into # 10 meter instrument, Serial 19606, Calibration date 29 Apr 1999 2 1 1 Ed412 0.0 -0.022488 0.000159 0 10 uwatts/cm2/nm 2 2 1 Ed443 0.0 -0.023146 0.000022 0 10 uwatts/cm2/nm 2 3 1 Ed490 0.0 -0.021964 0.000019 0 10 uwatts/cm2/nm 2 4 1 Ed510 0.0 -0.023653 0.000022 0 10 uwatts/cm2/nm 2 5 1 Ed555 0.0 -0.024395 0.000127 0 10 uwatts/cm2/nm 2 6 1 Ed670 0.0 -0.024439 0.000218 0 10 uwatts/cm2/nm 2 7 1 PAR 0.0 -10.184055 -0.000389 0 10 uEinsteins/cm2/sec 2 8 1 Gnd 0.0 1.0 0.000019 0 10 volts 2 9 2 Temp 0.0 0.1452 -0.0209 0 10 degC 2 10 5 Depth 0.2055 52.7973 26.3784 0 10 dbars # 10m MCP-200, Serial 7185, Calibration date 10Apr1996 # 2 11 7 MCP 1.0 0.074 0.0005 0 10 uwatts/cm2/nm 2 11 7 MCP 1.0 -90.802 0.0005 0 10 uwatts/cm2/nm 2 12 2 Fluor 0.0 1.0 0.0 0 10 volts 2 13 2 Gnd 0.0 1.0 0.000 0 10 volts 2 14 0 Gnd 0.0 1.0 0.000 0 10 volts # 30m MCP-200, Serial 7186, Calibration date 18sep97 # 2 15 7 MCP 1.0 0.086 -0.0003 0 10 uwatts/cm2/nm 2 15 7 MCP 1.0 -82.349 0.0005 0 10 uwatts/cm2/nm 2 16 2 Gnd 0.0 1.0 0.000 0 10 volts # 10 meter instrument, Serial 19606, Calibration date 29 Apr 1999 3 1 3 Lu443 0.0 -1.367544 0.000416 0 10 uwatts/cm2/nm/str 3 2 3 Lu412 0.0 -0.624659 0.000170 0 10 uwatts/cm2/nm/str 3 3 3 Lu490 0.0 -0.740213 0.000372 0 10 uwatts/cm2/nm/str 3 4 3 Lu510 0.0 -1.202967 0.000372 0 10 uwatts/cm2/nm/str 3 5 3 Lu555 0.0 -1.471696 0.000563 0 10 uwatts/cm2/nm/str 3 6 3 Lu670 0.0 -1.480455 0.000182 0 10 uwatts/cm2/nm/str 3 7 3 Lu683 0.0 -2.866699 0.000443 0 10 uwatts/cm2/nm/str 3 8 1 Gnd 0.0 1.0 0.0 0 10 volts